Filters
total: 3372
-
Catalog
- Publications 3167 available results
- Journals 4 available results
- Conferences 5 available results
- People 33 available results
- Inventions 1 available results
- Projects 2 available results
- Laboratories 1 available results
- Research Equipment 8 available results
- e-Learning Courses 133 available results
- Events 9 available results
- Offers 1 available results
- Open Research Data 8 available results
displaying 1000 best results Help
Search results for: static load test
-
Analysis of sloping brace stiffness influence on stability and load bearing capacity of a truss
PublicationThe paper is focused on the numerical study of stability and load bearing capacity of a truss with side elastic braces. The structure is made in reality. The rotational and sliding brace stiffnesses were taken into account. Linear buckling analysis and non-linear static analysis with geometric and material nonlinearity were performed for the beam and shell model of the truss with respect to the angle of sloping braces. As a result...
-
Contribution of dynamic vehicle loads to pavement failure
PublicationPavement surfaces are not ideally even, which causes dynamic loads of vehicle axles. Distribution of dynamic loads of a given axle is similar to normal distribution and can be described by static load and dynamic load coefficient. The dynamic load coefficient depends on road profile, vehicle speed, properties of suspensions and static load of axle. While for a given road section road profile remains constant, vehicle speed and...
-
Static Series and Shunt-series PE Voltage-quality Controllers
PublicationAs presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...
-
A novel sandwich footbridge - Practical application of laminated composites in bridge design and in situ measurements of static response
PublicationA novel sandwich composite footbridge is presented in the paper, as an example of practical application of laminated composites in civil engineering. The in situ static load tests of the footbridge before its acceptation for exploitation are shown and discussed. The results are compared with the corresponding ones from a numerical equivalent single layer model of the sandwich structure created within the framework of finite element...
-
Behaviour of deformed steel columns exposed to impact load during earthquakes: numerical analysis
PublicationIt has been observed during earthquakes that the so called soft-storey failure of an upper floor of a building leads to considerable vertical impact load acting on structural members of the lower storeys. The aim of this paper is to investigate numerically the behaviour of horizontally deformed columns (deformation as the result of earthquake loading) that are additionally subjected to vertical impact load. In the first stage of...
-
Static Shunt PE Voltage-Quality Controllers
PublicationThis chapter focuses on power electronics (PE)-based solutions used in distribution networks for reduction of supply-voltage-quality deterioration, from long interruptions to the harmonics. Various PE devices and their combinations are addressed for particular or a range of voltage disturbances. A particular solution is applied taking into account demands for voltage quality and network configuration. In general, there are three...
-
Stability and load bearing capacity of a truss with elastic braces
PublicationThe present paper is devoted to the numerical and experimental investigations of stability of a truss stiffened by elastic braces. The model of a real roof truss scaled by factor ¼ was investigated. In the research the linear buckling and non-linear static analysis of the truss shell and beam model with geometric and material non-linearity is presented. The initial imperfections were assumed in the form of the first buckling mode....
-
Arch bridges under test loadings
PublicationThis paper illustrates experience in arch bridges test loadings of the research team of Department of Structural Mechanics and Bridge Structures from the Gdansk University of Technology. The presented calculations results constist the analysis of spatial construction schemes made using the finite elements method (FEM) and its comparison to the field studies. Arch bridges with the longest spans, visualisation of the computational...
-
Investigation of stability and limit load of a truss overhead opened bridge
PublicationThe paper presents selected methods of determining stability and limit load of a truss top chord in opened bridges. These methods include linear buckling and non-linear static analysis based on the finite element method and algorithms based on design code procedures. The described methods were tested on an example of a steel footbridge situated in Straszyn. The results of stability analysis are compared. The results of geometrical...
-
Consideration of dynamic loads in the determination of axle load spectra for pavement design
PublicationAxle load spectra constitute a crucial part of the data for pavement design and pavement distress analysis. Typically, axle load spectra represent static load from vehicles and do not include dynamic loads generated by vehicles in motion. While dynamic loads can significantly contribute to faster pavement distress, this fact is mostly omitted in pavement design methods. The paper presents a methodology for consideration of dynamic...
-
Load effect impact on the exploitation of concrete machine foundations used in the gas and oil industry
PublicationMachine foundations is a critical topic in the gas and oil industry, which design and exploitation require extensive technical knowledge. Machine foundations are the constructions which are intended for mounting on it a specific type of machine. The foundation has to transfer dynamic and static load from machine to the ground. The primary difference between machine foundations and building foundations is that the machine foundations...
-
Stability and limit load analysis of a cold-formed channel section column
PublicationThe paper presents stability and limit load analysis of a steel column 1440 mm high of a cold-formed channel section, subjected to a combination of compression and bending. Experimental results were compared to the resistance of a code procedure and to the outcome of numerical non-linear analysis. Comparison was made of numerical solutions by means of static (Riks) and dynamic (Explicit and Implicit) methods. Perfectly elastic...
-
STABILITY AND LOAD BEARING CAPACITY OF A BARS WITH BUILT UP CROSS SECTION AND ELASTIC SUPPORTS
PublicationThe present paper is devoted to the numerical analysis and experimental tests of compressed bars with built–up cross section which are commonly used as a top chord of the roof trusses. The significant impact on carrying capacity for that kind of elements in case of out-of-plane buckling is appropriate choice of battens which are used to provide interaction between separate members. Linear buckling analysis results and nonlinear static...
-
Adaptive identification of sparse underwater acoustic channels with a mix of static and time-varying parameters
PublicationWe consider identification of sparse linear systems with a mix of static and time-varying parameters. Such systems are typical in underwater acoustics (UWA), for instance, in applications requiring identi- fication of the acoustic channel, such as UWA communications, navigation and continuous-wave sonar. The recently proposed fast local basis function (fLBF) algorithm provides high performance when identi- fying time-varying systems....
-
Retrievable strain measuring system in screw displacement piles - readings and results interpretation problems
PublicationStatic load tests on foundation piles are generally carried out in order to determine load – displacement characteristic of the pile. For more detailed information, e.g. force distribution along the shaft, load transfer mechanism and characteristics of soil-structure interaction (unit resistance curves t-z, q-z) additional pile instrumentation is required. Most popular techniques focus on direct concrete strain measurements and...
-
Load Testing of GFRP Composite U-Shape Footbridge
PublicationThe paper presents the scope of load tests carried out on an innovative shell composite footbridge. The tested footbridge was manufactured in one production cycle and has no components made from materials other than GFRP laminates and PET foam. The load tests, performed on a 14-m long structure, were the final stage of a research program in the Fobridge project carried out in cooperation with: Gdańsk University of Technology (leader),...
-
Innovative Cold-formed GEB Section under Bending
PublicationThis paper is concerned with the numerical bending capacity study of the innovative cold-formed GEB sections. Both linear buckling analysis and non-linear static analysis incorporating geometric and material nonlinearity were carried out employing a shell structural model. The magnitudes of buckling load and limit load with respect to GEB section depth and thickness were obtained. The opened cold-formed section was tested assuming...
-
BADANIA ODBIOROWE ŁUKOWEJ KŁADKI DLA PIESZYCH 10T NAD DROGĄ S8 W WARSZAWIE
PublicationThe paper presents in situ load testing of the newly build footbridge over S8 expressway in Warsaw. The most characteristic thing for the structure is a shape of arch girders, which correspond with adjacent half-tunnel acoustic baffles. The paper consists of description of the structure, results of the in-situ static and dynamic load testing, results of the numerical simulations, comparative analysis and final conclusions on the...
-
TB11 test for short w-beam road barrier
PublicationFEM (Finite Element Method) is well-suited and widely used tool for simulating a range of phenomena: from these with simple and static behaviour, up to those complicated, highly nonlinear and involving many contacts. In present paper we use one of the advantages of FEM: parametric study could be easily performed and is more economical than series of in-situ tests. If recommended practices is carefully followed, results obtained...
-
Historical crane on the redesigned original trestle bridge as a memorial of Gdansk Shipyard
PublicationThe paper includes selected aspects of the study, whose goal is to hold the historical crane 642-24 in its current location after the modification of trestle bridge static scheme. The scope of the paper includes the assessment of current technical condition of the object, a presentation of FEM analyses, a description of the assumed load cases, results of the static calculations, checking the effort of construction elements, global...
-
A comparative analysis of numerically simulated and experimentally measured static responses of a floating dock
PublicationTwo numerical methods, dynamic and static analyses, are proposed to calculate the static responses of a floating dock under different ballast water distributions. Model-scale experimental tests were conducted to compare with these numerical methods. The dynamic analysis includes a 6-degree-of-freedom (6-DOF) model, a hydrostatic force model and a hydrodynamic force model to simulate the dock's freely floating processes. The dock's...
-
Visual perception of vowels from static and dynamic cues
PublicationThe purpose of the study was to analyse human identification of Polish vowels from static and dynamic durationally slowed visual cues. A total of 152 participants identified 6 Polish vowels produced by 4 speakers from static (still images) and dynamic (videos) cues. The results show that 59% of static vowels and 63% of dynamic vowels were successfully identified. There was a strong confusion between vowels within front, central,...
-
Interlaboratory Test to Characterize the Cyclic Behavior of Bituminous Interlayers: An Overview of Testing Equipment and Protocols
PublicationThe performance assessment of multi-layered pavements strongly depends on the mechanical behavior of the interface between bituminous layers. So far, comprehensive studies have been carried out mainly using quasi-static laboratory tests focusing on the interlayer shear strength at failure. However, it is generally recognized that cyclic shear testing will lead to the determination of parameters which are more closely linked to...
-
Measurements of displacement and acceleration of the railway bridge at km 333-254 of the Vilnius - Klaipeda railway line
PublicationThe purpose of this work is to perform a report of static and dynamic test realized on the bridge at km 333-254 of the Vilnius - Klaipeda railway line over the Salantas River in Kūlupėnų.
-
Interlaboratory Test to Characterize the Cyclic Behavior of Bituminous Interlayers: An Overview of Testing Equipment and Protocols
PublicationThe performance assessment of multi-layered pavements strongly depends on the mechanical behavior of the interface between bituminous layers. So far, comprehensive studies have been carried out mainly using quasi-static laboratory tests focusing on the interlayer shear strength at failure. However, it is generally recognized that cyclic shear testing will lead to the determination of parameters which are more closely linked to...
-
ANALYSIS OF BRACE STIFFNESS INFLUENCE ON STABILITY OF THE TRUSS
PublicationThe paper is devoted to the numerical and experimental research of stability of a truss with side elastic supports at the top chord. The structure is a model of a real roof truss scaled by factor ¼. The linear buckling analysis and non-linear static analysis were carried out. The buckling length factor for the compressed top chord was calculated and the limit load for the imperfect truss shell model with respect to brace stiffness...
-
Comparative Analysis of Reactive Power Compensation Devices in a Real Electric Substation
PublicationA constant worldwide growing load stress over a power system compelled the practice of a reactive power injection to ensure an efficient power network. For this purpose, multiple technologies exist in the knowledge market out of which this paper emphasizes the usage of the flexible alternating current transmission system (FACTS) and presents a comparative study of the static var compensator (SVC) with the static synchronous compensator...
-
Numerical investigations of discrete crack propagation in Montevideo splitting test using cohesive elements and real concrete micro-structure
PublicationThe paper is aimed at accurately predicting the discrete fracture process in concrete specimens under complex stress states in two dimensional (2D) simulations. Plain concrete specimens subjected to Montevideo splitting test (MVD) were used for consideration due to non-negligible shear stresses impact in this type of test. In order to reflect the heterogeneous nature of the concrete, the meso-structure of the samples was included...
-
Cable-stayed bridges. Basic static schemes
PublicationThe paper presents an overview of shaping of cable-stayed bridges. Historical background, basic static sketches and overview of selected bridges are included. Selected natural solutions and interesting unrealized projects were presented. Basic ideas and most important principals are discussed. The examples and sketches were given an author's comment. Static diagrams of two pylon structures with three variants of the arrangement...
-
Experimental study of the impact of notches and holes made in the front edge of adherends on the properties of static and fatigue strength of adhesive joints
PublicationThe paper presents the results of experimental studies aimed at determining the effect of holes and notches at the front edge of adherends on the strength of adhesive joints. Single-lap joints made of S235JR steel sheets joined with Araldite 2014-2 epoxy adhesive were tested. Comparative tests of static strength in the shear test as well as high-cycle fatigue strength tests were carried out. Joints with three holes with a diameter...
-
Effect of pavement roughness and vehicle dynamic loads on decrease of fatigue life of flexible pavements
PublicationDue to the fact that pavement surfaces are not ideally even, dynamic loads of vehicle axles deviate from static loads. Higher dynamic loads contribute to faster pavement distress. The distribution of dynamic loads is similar to normal distribution and can be described by static load and factors DI (dynamic impact) and DLC (dynamic load coefficient). With the deterioration of pavement condition its evenness decreases as well and...
-
Combined environmental testing device for picosatellites
PublicationAs access to space conditions becomes more available, both technically and economically, scientists’ interest in launching finer and more sophisticated experiments grows. To be qualified for launch, such experiments need to be carefully tested prior to the event. The tests should represent actual launch conditions as closely and in a detailed manner. Typical tests for payload include: vibration tests, thermal and vacuum tests,...
-
Stability of a truss under upward wind loading
PublicationThe present paper is devoted to the numerical investigations of stability of a truss under upward wind load. The truss is braced at its the upper cord. A structural variant including lateral braces, or lateral and torsional braces is considered. The research presents the problems of linear buckling and non-linear static analysis of the truss shell and beam model with geometric and material non-linearity are presented. The initial...
-
Modelling of shear zones during quasi-static granular silo flow using material point method (MPM)
PublicationThe paper focuses on confined silo flow of cohesionless sand. The problem considered is a quasi-static flow in a plane strain model silo with parallel walls simulated with the material point method (MPM). The simulation used a non-local hypoplastic constitutive model. Initially, the paper validated the implemented numerical approach with basic element tests and a plane strain compression test. The subsequent MPM calculations for...
-
Impact of power electronic Var compensators installed in certain grid points on the voltage failure
PublicationThe article presents the test results of the various types of static compensators FACTS models in the power system. The basic case, which was analyzed, it was behavior of compensators which are installed in select points of the system during voltage failure. The article presents selected results of studies conducted as part of a work [2].
-
Static Model of Steam/Water Cycle for Thermal and Economic Analysis
PublicationThe thermodynamic efficiency of typical conventional and nuclear power plants is insufficient. A large amount of the generated heat is removed to the environment and regarded as a waste. A solution which is commonly used to increase the efficiency and profitability of the existing and planned power plants refers to cogeneration of heat and power. To prepare sophisticated thermodynamic and economic analyses, a precise static model...
-
REINFORCED CONCRETE SUPPORTING CONSTRUCTION OF THE STADIUM COVER FOR EURO 2012 IN GDAŃSK
PublicationIn the article structural issues that connected with the reinforced concrete supporting construction of the stadium roofing for EURO 2012 in Gdańsk were described. In the first part of the article the concept of stadium foundation were described. In the second the static - strength analysis for two variants fastening together individual foundation elements were made. The two assumed geometrically different concept of foundation...
-
Establishing Relationships between Parameters of the controlled Compaction Soil by Using Various In-Situ Tests
PublicationThe aim of research was evaluating reliable correlations between chosen soil parameters describing state of surface layers of soil. The paper presents site comparative tests based on the light falling weight deflectometer (LFWD), the static plate load tester (VSS), the dynamic probing light tester (DPL) and the bearing ratio tester (CBR in-situ) with relationships between soil state parameters. All featured in-situ...
-
Nonlocalized thermal behavior of rotating micromachined beams under dynamic and thermodynamic loads
PublicationRotating micromachined beams are one of the most practical devices with several applications from power generation to aerospace industries. Moreover, recent advances in micromachining technology have led to huge interests in fabricating miniature turbines, gyroscopes and microsensors thanks to their high quality/reliability performances. To this end, this article is organized to examine the axial dynamic reaction of a rotating...
-
Stan awaryjny wiaduktu kolejowego w Bydgoszczy
PublicationW pracy przedstawiono opis stanu awaryjnego wiaduktu kolejowego. Omówiono wyniki badań in situ oraz teoretycznych analiz statyczno-wytrzymałościowych ponad 100-letniego obiektu. Przedstawiono wnioski i zalecenia dotyczące doraźnego zabezpieczenia obiektu oraz warunki jego dalszej eksploatacji.
-
Stan awaryjny wiaduktu kolejowego w Bydgoszczy
PublicationW pracy przedstawiono opis stanu awaryjnego wiaduktu kolejowego. Omówiono wyniki badań in situ oraz teoretycznych analiz statyczno-wytrzymałościowych ponad 100-letniego obiektu. Przedstawiono wnioski i zalecenia dotyczące doraźnego zabezpieczenia obiektu oraz warunki jego dalszej eksploatacji.
-
The use of the static thermography in monitoring flap perfusion in breast reconstruction with TRAM flap
PublicationThis paper shows results of the static thermography for intraoperative and postoperative imaging of TRAM flap perfusion. The results were compared with the clinical examination of flap perfusion. The study was conducted on a group of 38 female patients who underwent breast reconstruction.
-
Static and dynamic concrete calculations: Breakable aggregates in DEM model
PublicationThe paper deals with the calculations of a 3-point bending beam under static and dynamic loads. The real microstructure was obtained from laboratory tests using micro-tomography images. The quasi-static results were compared directly with experimental data at both macro and micro levels. Subsequently, higher strain rates were applied to investigate dynamic effects. The study focused on the influence of dynamic loading on the macroscopic...
-
Adaptive Identification of Underwater Acoustic Channel with a Mix of Static and Time-Varying Parameters
PublicationWe consider the problem of identification of communication channels with a mix of static and time-varying parameters. Such scenarios are typical, among others, in underwater acoustics. In this paper, we further develop adaptive algorithms built on the local basis function (LBF) principle resulting in excellent performance when identifying time-varying systems. The main drawback of an LBF algorithm is its high complexity. The subsequently...
-
Characterization of corrosion in reinforced concrete beams using destructive and non-destructive tests
PublicationThe paper presents both non-destructive and destructive experimental tests on steel-reinforced concrete beams subjected to electrochemical corrosion. To examine the condition and behavior of the specimens, destructive tests were carried out, i.e., a three-point bending together with a modulated ultrasonic wave test. In addition, a series of non-destructive experiments were conducted, such as the potential measurement method, low-frequency...
-
The influence of welding heat input on the quality and properties of high strength low-alloy dissimilar steel butt joints
PublicationThe paper presents the results of non-destructive and destructive tests of dissimilar highstrength low-alloy S460ML and S460N steel butt joints. These steels are characterized by similar mechanical properties, but their carbon equivalent CeIIW values are much different. The joints were made using different values of heat input for each welding bead. They were tested by non-destructive methods: visual, penetrant, radiographic and...
-
Effect of long term service at elevated temperatures on mechanical properties of Manaurite XM reformer tubes
PublicationMicrostructure transformations occur in the Manaurite XM cast steel tubes during long-term operation in the reformer furnace were revealed and described. The rela tionship between mechanical properties, an increase of internal diameter of the tube and microstructure degradation is discussed. Static tensile test was performed on two types of samples with different shapes. It has been shown differences in the results of tests...
-
Computational modelling of historic masonry railroad arch bridges
PublicationThe problems encountered during the analyzes of structural response of historic masonry railroad arch bridges are described in this paper. The attention is mainly focused on the stiffness of the masonry arches, their strengths and appropriate estimation of railroad load intensity. Issues related to computational modelling of two, existing, almost 130 years old masonry arch railroad bridges are presented in this context. The main...
-
Pore Water Pressure Development in Soft Soil due to Installation and Loading of Controlled Modulus Columns
PublicationExcess pore water pressure (EPWP) development and decay due to the installation and static loading tests of controlled modulus columns (CMC) in soft soil was measured with piezometers equipped with low air entry (LAE) filters and a piezocone (CPTU) equipped with a high air entry (HAE) filter. The HAE filter allows for detailed detection of EPWP in short time intervals during construction of CMC. The influence zone due to the installation...
-
Dynamic load tests of piles in non-cohesive soils.
PublicationThe results of investigations of various types of piles, the analysis of dynamic tests carried out recently in Poland and the correlations between the results of dynamic and static tests of piles are presented. Przedstawiono wyniki badań nośności różnych rodzajów pali, analizę badań dynamicznych wykonanych w Polsce w ostatnich latach oraz korelacje pomiędzy wynikami badań statycznych i dynamicznych.