Search results for: electrodes
-
ECG measurement in the bathtub - drl outside the bathtub on both sides- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
ECG measurement in the bathtub - drl on one side of the bath, the mass of the system on the other- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Reactivation of seizure‐related changes to interictal spike shape and synchrony during postseizure sleep in patients
PublicationOBJECTIVE: Local field potentials (LFPs) arise from synchronous activation of millions of neurons, producing seemingly consistent waveform shapes and relative synchrony across electrodes. Interictal spikes (IISs) are LFPs associated with epilepsy that are commonly used to guide surgical resection. Recently, changes in neuronal firing patterns observed in the minutes preceding seizure onset were found to be reactivated during postseizure...
-
Application of bismuth film electrode for determination of heavy metals by stripping voltammetry
PublicationWhen Wang's research group introduced a new type of a working electrode: bismuth film plated electrode (BiFE), it has started attracting increasing attention in the field of electrochemical stripping analysis. These electrodes are shown to be very attractive alternative to common mercury-based electrodes, which are predominantly used in analysis of trace heavy metals.For the determination of heavy metals (Zn, Cd, Pb, Cu) used square...
-
Application of electrochemical impedance spectroscopy to monitoring discharging process of nickel/metal hydride battery.
PublicationThis paper presents the possibility of applying impedance analysis to cell diagnostics. In order to obtain characteristic curves of both electrodes of a NiMH battery simultaneously, a reference electrode was added into the circuit. The authors analysed the cell under three cases, i.e. when its properties are determined only by the state of the positive electrode, only by the state of the negative electrode, or when both electrodes...
-
Laser patterned platform with PEDOT–graphene composite film for NO2 sensing
PublicationThis work presents a simple and fully electrochemical route used for fabricating of a NO2 gas sensor made of reduced-graphene-oxide-poly(3,4-ethylenedioxythiophene) composite film. The sensing platform was fabricated from alumina substrate and equipped with gold interdigitated electrodes and built-in heater.The temperature distribution on the surface of interdigitated electrodes was investigated by a thermalimaging camera and compared...
-
Effect of underwater wet welding conditions on the diffusible hydrogen content in deposited metal
PublicationIn the study mercury displacement method was used for determination of diffusible hydrogen amount in deposited metal obtained during underwater wet welding with covered electrodes in laboratory conditions according to a two-level full factorial design for three factors. The factors and their levels were chosen among conditions and parameters of welding in accordance with the results of own preliminary studies. A statistical analysis...
-
Investigation of Narrow Electrostatic Precipitator with Wire Multi-Electrode
PublicationDiesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are notenough effective or very expensive. An electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission. Therefore, narrow electrostatic precipitators (ESPs) have become a subject of interest...
-
Weldability of Underwater Wet-Welded HSLA Steel: Effects of Electrode Hydrophobic Coatings
PublicationThe paper presents the effects of waterproof coatings use to cover electrodes on the weldability of high-strength, low-alloy (HSLA) steel in water. With the aim of improving the weldability of S460N HSLA steel in water, modifications of welding filler material were chosen. The surfaces of electrodes were covered by different hydrophobic substances. The aim of the controlled thermal severity (CTS) test was to check the influence...
-
A miniaturized solid-contact potentiometric multisensor platform for determination of ionic profiles in human saliva
PublicationThis paper describes a miniaturized multisensor platform (MP-ISES) consisting of electrodes: a reference one (RE) and ion-selective electrodes (ISEs) for monitoring Na+, K+, Ca2+, Mg2+, Cl−, and SCN− ions and pH in human saliva. Gold electrode surface was modified by deposition of two layers: electrosynthesized PEDOT:PSS forming an intermediate layer, and ion-selective membrane. The developed ISEs were characterized by a wide linear...
-
The Effect of C45 Carbon Black-Phosphomolybdic Acid Nanocomposite on Hydrogenation and Corrosion Resistance of La2Ni9Co Hydrogen Storage Alloy
PublicationIn this paper, we analysed the influence of corrosion processes and the addition of a carbon black-heteropoly phosphomolybdic acid (C45-MPA) nanocomposite on the operating parameters of a hydride electrode obtained on the basis of the intermetallic compound La2Ni9Co. The electrochemical properties of negative electrodes for NiMH batteries were studied using galvanostatic charge/discharge curves, the potentiostatic method, and electrochemical...
-
ECG measurement in the bathtub - drl on one side of the bathtub, the other side of the bathtub is grounded and the system ground is grounded- men
Open Research DataThe measurement data shows the measurement of the ECG signal in water in the bathtub. The data includes the measurement time, the reference ECG signal from the chest, and the ECG signal measured by electrodes placed in the bathtub without contact with the human body. Using the presented data, it is possible to estimate the optimal arrangement of measuring...
-
Scanning electron microscopy (SEM) images of the boron-doped carbon nanowalls surfaces
Open Research DataThe dataset contains the scanning electron micrographs (SEM), revealing the surface morphology of boron-doped carbon nanowalls electrodes on silicon substrates. The surface is characterized by nano-walled structures. The obtained electrodes were doped with boron at the level of [B]/[C] = 5000ppm in the gas atmosphere during the synthesis.
-
Scanning electron microscopy (SEM) images of the boron-dopied carbon nanowalls surfaces
Open Research DataThe dataset contains the scanning electron micrographs (SEM), revealing the surface morphology of boron-doped carbon nanowalls electrodes on silicon substrates. The surface is characterized by nano-walled structures. The obtained electrodes were doped with boron at the level of [B]/[C] = 1200ppm in the gas atmosphere during the synthesis.
-
Scanning electron microscopy (SEM) images of the boron-doped carbon nanowalls surfaces
Open Research DataThe dataset contains the scanning electron micrographs (SEM), revealing the surface morphology of boron-doped carbon nanowalls electrodes on silicon substrates. The surface is characterized by nano-walled structures. The obtained electrodes were doped with boron at the level of [B]/[C] = 2000ppm in the gas atmosphere during the synthesis.
-
Aquatic biomass containing porous silica as an anode for lithium ion batteries
PublicationA composite electrode was manufactured by pyrolysis of Red Algae (Polysiphonia fucoides) covered by diatoms (Diatomophyceae). Electrodes were tested as a half cell with capacity of 500 mA h g−1 after 80 cycles. XPS analysis shows formation of lithium silicate under reduction of silica in an aprotic electrolyte containing LiPF6 salt.
-
Effectiveness of a dual surface modification of metallic interconnects for application in energy conversion devices
PublicationA dual surface modification of an SOFC metallic interconnect with a Gd2O3 layer and an MnCo2O4 coating was evaluated. The tested samples were oxidized for 7000 h in air at 1073 K. Oxidation products were characterized using XRD, SEM-EDS, and confocal Raman imaging, and ASR was measured. The effect of gadolinium segregation at grain boundaries in Cr2O3 was evaluated using S/TEM-EDS. Area specific-resistance was measured and fuel...
-
Solid State Conductivity of Optimized Polypyrrole Coatings on Iron Obtained from Aqueous Sodium Salicylate Solution Determined by Impedance Spectroscopy
PublicationIn this work the optimization procedure for corrosion resistance, surface analysis and electrical properties of PPy-Fe electrodes have been examined. Polypyrrole (PPy) film was electrochemically synthesized in a one step process from an aqueous solution of sodium salicylate and pyrrole with certain concentrations, different parameters and type of polymerization...
-
Investigation of Narrow Transverse and Longitudinal Electrostatic Precipitators
PublicationDiesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. An electrostatic precipitation was proposed as an alternative method for control of a diesel particulate emission. Therefore, narrow electrostatic precipitators (ESPs) have become a subject of...
-
Tailoring properties of reduced graphene oxide by oxygen plasma treatment
PublicationWe report an easily controllable, eco-friendly method for tailoring the properties of reduced graphene oxide (rGO) by means of oxygen plasma. The effect of oxygen plasma treatment time (1, 5 and 10 minutes) on the surface properties of rGO was evaluated. Physicochemical characterization using microscopic, spectroscopic and thermal techniques was performed. The results revealed that different oxygen-containing groups (e.g. carboxyl,...
-
Electrochemical oxidation of landfill leachate using boron-doped diamond anodes: pollution degradation rate, energy efficiency and toxicity assessment
PublicationElectrochemical oxidation (EO), due to high efficiency and small carbon footprint, is regarded as an attractive option for on-site treatment of highly contaminated wastewater. This work shows the effectiveness of EO using three boron-doped diamond electrodes (BDDs) in sustainable management of landfill leachate (LL). The effect of the applied current density (25–100 mA cm−2) and boron doping concentration (B/C ratio: 500 ppm, 10,000...
-
Tailoring diamondised nanocarbon-loaded poly(lactic acid) composites for highly electroactive surfaces: extrusion and characterisation of filaments for improved 3D-printed surfaces
PublicationA new 3D-printable composite has been developed dedicated to electroanalytical applications. Two types of diamondised nanocarbons - detonation nanodiamonds (DNDs) and boron-doped carbon nanowalls (BCNWs) - were added as fillers in poly(lactic acid) (PLA)-based composites to extrude 3D filaments. Carbon black served as a primary filler to reach high composite conductivity at low diamondised nanocarbon concentrations (0.01 to 0.2...
-
From ashes to porous hierarchical nanocarbon electrode: Upcycling secondary waste materials through self-catalytic chemical vapour deposition
PublicationMetal and metal oxide particles are abundant in various ash-based wastes. Utilizing these as catalyst sources for the fabrication of carbon nanomaterials could present a valuable approach to reduce our reliance on non-renewable and costly catalyst sources, thereby facilitating large-scale nanomaterial production. In this context, secondary waste materials (SWMs) are by-products resulting from the (complete or partial) combustion...
-
Behavioral state classification in epileptic brain using intracranial electrophysiology
PublicationOBJECTIVE: Automated behavioral state classification can benefit next generation implantable epilepsy devices. In this study we explored the feasibility of automated awake (AW) and slow wave sleep (SWS) classification using wide bandwidth intracranial EEG (iEEG) in patients undergoing evaluation for epilepsy surgery. APPROACH: Data from seven patients (age [Formula: see text], 4 women) who underwent intracranial depth electrode...
-
SrCe0.9In0.1O3-δ-based reversible symmetrical Protonic Ceramic Cell
PublicationIn-doped SrCe0.9In0.1O3-δ (SCI) perovskite-type oxide is utilized as the solid electrolyte, as well as a component, together with SrFe0.75Mo0.25O3-δ (SFM) compound, in the composite-type electrodes to construct symmetrical Protonic Ceramic Fuel Cells (PCFC). With good mutual stability of SCI and SFM at high temperatures in water vapor-containing reducing and oxidizing conditions, as well as sufficient ionic conductivity with high...
-
Impact of strontium non-stoichiometry of SrxTi0.3Fe0.7O3-δ on structural, electrical, and electrochemical properties for potential oxygen electrode of intermediate temperature solid oxide cells
PublicationThis work presents the results of a comprehensive study on the impact of the A-site non-stoichiometry of SrxTi0.3Fe0.7O3-δ (x = 0.90, 0.95, 1.00, 1.05) ceramics on their physicochemical properties. The materials were fabricated by the conventional solid-state reaction method and their structure was determined by X-ray diffractometry, X-ray photoelectron spectroscopy and electron microscopy. Their sintering and thermal expansion...
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 800 °C and 15% oxygen partial pressure
Open Research DataThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 800 °C and 15% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included....
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 600 °C and 15% oxygen partial pressure
Open Research DataThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 600 °C and 15% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included. Results converted...
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 700 °C and 15% oxygen partial pressure
Open Research DataThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 700 °C and 15% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included....
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 700 °C and 100% oxygen partial pressure
Open Research DataThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 700 °C and 100% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included....
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 700 °C and 20% oxygen partial pressure
Open Research DataThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 700 °C and 20% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included....
-
Electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for porous SrTi0.30Fe0.70O3-d oxygen electrode measured at 700 °C and 5% oxygen partial pressure
Open Research DataThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 700 °C and 5% of oxygen partial pressure. Spectra of two RCPE elements from equivalent circuit , are also included. Results...
-
Electrohydrodynamic flow patterns and collection efficiency in narrow wire-cylinder type electrostatic precipitator
PublicationRecently, narrow electrostatic precipitators (ESPs) have become a subject of interest because of their possible application for the cleaning of the exhaust gases emitted by diesel engines. Diesel engines emit fine particles, which are harmful to human and animal health. There are several methods for decrease particulate emission from a diesel engines, but up to now, these methods are not enough effective or very expensive. Therefore,...
-
Biobatteries and biofuel cells with biphenylated carbon nanotubes
PublicationSingle-walled carbon nanotubes covalently biphenylated are used for the construction of cathodes in a flow biobattery and in flow biofuel cell. Zinc covered with a hopeite layer is the anode in the biobattery and glassy carbon electrode covered with bioconjugates of single-walled carbon nanotubes with glucose oxidase and catalase is anode of the biofuel cell. The potentials of the electrodes are measured vs. the Ag/AgCl reference...
-
Results of EIS measuremnts and DRT analysis of SrTi0.30Fe0.70O3-d oxygen electrode at 800 °C and 1% oxygen partial pressure by using three R-CPE fiting elements
Open Research DataThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 800 °C and 1% of oxygen partial pressure. EIS and DRT spectra of simmulated three R-CPE elements from equivalent circuit,...
-
Results of EIS measuremnts and DRT analysis of SrTi0.30Fe0.70O3-d oxygen electrode at 800 °C and 1% oxygen partial pressure by using two R-CPE fiting elements
Open Research DataThis dataset contains electrochemical impedance spectroscopy and Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 800 °C and 1% of oxygen partial pressure. EIS and DRT spectra of simmulated two R-CPE elements from equivalent circuit,...
-
Nanostructure of the laser-modified transition metal nanocomposites for water splitting
PublicationAlthough hydrogen is considered by many to be the green fuel of the future, nowadays it is primarily produced through steam reforming, which is a process far from ecological. Therefore, emphasis is being put on the development of electrodes capable of the efficient production of hydrogen and oxygen from water. To make the green alternative possible, the solution should be cost-efficient and well processable, generating less waste...
-
Capacitively coupled ECG measurements - a CMRR circuit improvement
PublicationA typical galvanic-connected electrocardiogram (ECG) measurement system utilizes two signal’s electrodes and a third one in driven-right-leg (DRL) circuit for improving a common-mode rejection ratio(CMRR) of the acquisition system. In capacitive-coupled ECG similar techniques are used, however it is expected, that the utilized DRL subsystem is formed using a capacitive coupling approach, too. An improvement of the acquisition system...
-
Multianalyte Calibration Methods for Potentiometric Integrated Sensors System for Determination of Ions Concentration in a Body Fluids
PublicationIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in a small sample volume. One of the key problems related to the preparation of integrated sensors systems (ISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim of the research...
-
GRAPHENE-BASED SUPERCAPACITORS APPLICATION FOR ENERGY STORAGE
PublicationRecent advances in graphene-based supercapacitor technology for energy storage application were summarized. The comparison of different types of electrode materials in such supercapacitors was performed. The supercapacitors with graphene-based electrodes exhibit outstanding performance: high charge-discharge rate, high power density, high energy density and long cycle-life, what makes them suitable for various applications, e.g....
-
Application of Ionic Liquids in Amperometric Gas Sensors
PublicationThis article presents an analysis of available literature data on metrological parameters of the amperometric gas sensors containing ionic liquids as an electrolyte. Four mechanism types of signal generation in amperometric sensors with ionic liquid are described. Moreover, this article describes the influence of selected physico-chemical properties of the ionic liquids on the metrological parameters of these sensors. Some metrological...
-
Protonic Ceramic Fuel Cells as novel electrochemical devices
PublicationProton ceramic conductors are novel materials which are interesting from the application point of view. For example, Protonic Ceramic Fuel Cells (PCFCs) is a type of a solid oxide fuel cell, which uses proton ceramic conductors as an electrolyte. Scientists are looking for the most efficient materials for these devices. In recent years main focus has been put on the search for new proton and mixed proton-electron conductors which...
-
Anodic titania nanotubes decorated with gold nanoparticles produced by laser-induced dewetting of thin metallic films
PublicationHerein, we combine titania layers with gold species in a laser-supported process and report a substantial change of properties of the resulting heterostructures depending on the major processing parameters. Electrodes were fabricated via an anodisation process complemented with calcination to ensure a crystalline phase, and followed by magnetron sputtering of metallic films. The obtained TiO2 nanotubes with deposited thin (5, 10...
-
The computational methods in the development of a novel multianalyte calibration technique for potentiometric integrated sensors systems
PublicationIn recent years, integration and miniaturization of ion-selective electrodes (ISEs) have brought many benefits resulting in the possibility of simultaneous determination of the ions concentration in small volume samples. One of the key problems related to the preparation of potentiometric integrated sensors systems (PISSs) is a calibration procedure due to the necessity to calibrate each particular sensor separately. The main aim...
-
Selection of the lambda parameter for DRT analysis of SrTi0.30Fe0.70O3-d oxygen electrode at 800 °C and 1% oxygen partial pressure
Open Research DataThis dataset contains results of selection of the lambda parameter for Distribution of Relaxation Times analysis results for symmetrical cell with porous SrTi0.30Fe0.70O3-d oxygen electrodes sintered at 800 °C. EIS spectra were measured at 800 °C and 1% of oxygen partial pressure. Used lambdas: 5 x 10^(-3), 1 x 10^(-3), 5 x 10^(-4) and 1 x 10^(-4)....
-
Azo and azoxythiacrown ethers: synthesis and properties
PublicationA series of 16- and 18-membered azo- and azoxythiacrown ethers have been synthesized by reductive macrocyclization of the respective bis(nitrophenoxy)oxaalkanes. The aromatic residues located in the polyether region of the molecule were introduced to macrocyclic skeletons and their affinities toward different groups of metal cations in ion-selective electrodes were described. X-ray structures for one dinitropodand and one azoxybenzothiacrown...
-
Electrochemical glucose sensor based on the glucose oxidase entrapped in chitosan immobilized onto laser-processed Au-Ti electrode
PublicationThe study on novel electrode material composed of structured titanium foil with embedded Au nanoparticles and modified with chitosan with entrapped glucose oxidase is presented. To confirm the successful immobilization of glucose oxidase FT-IR analysis was performed. The response of electrodes were tested towards glucose in the presence of different interference compounds and biological fluids. The prepared material exhibits excellent...
-
Spawalność ferrytyczno-austenitycznej stali odpornej na korozję typu dupleks 2205 w warunkach podwodnych
PublicationPraca dotyczy problemów spawalności stali odpornej na korozję typu dupleks w warunkach spawania mokrego elektrodami otulonymi i lokalną komorą suchą. Całość rozprawy składa się z dwóch części. Część pierwsza to przegląd literatury, w którym omówiono główne problemy wynikające z przeniesienia procesu spawania pod wodę oraz sposoby minimalizowania negatywnego wpływu środowiska. Część druga jest częścią doświadczalną, zawiera tezę...
-
A prototype of electrochemical sensor for measurement of carbonyl compounds in air
PublicationThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde and formaldehyde in air. Sensitivity, limit of quantification and coefficient of selectivity of the sensor have been determined as a function of membrane thickness and electrode type using square wave voltammetry (SWV) technique. The working and counter electrodes were made of platinum and gold. Ionic liquids 1-hexyl, 3-methylimidazolium...
-
Multichannel Human Body Communication
PublicationHuman Body Communication is an attractive alternative for traditional wireless communication (Bluetooth, ZigBee) in case of Body Sensor Networks. Low power, high data rates and data security makes it ideal solution for medical applications. In this paper, signal attenuation for different frequencies, using FR4 electrodes, has been investigated. Performance of single and multichannel transmission with frequency modulation of analog...