Filters
total: 550
Search results for: SECOND SPECTRUM
-
Laboratory Stand for Wideband Analysis Radiocommunication Signals
PublicationA laboratory stand for wideband analysis radiocommunication signals is presented in the paper. The stand is designed for signals acquisition in wide spectrum and research a field of digital signal processing. Procedures used for simultaneous acquiring many frequency channels in selected wide band are described. The method of detection of direct sequence spread spectrum signals (DS SS) which power spectral density is lower than...
-
Laboratory stand for wideband analysis radiocommunication signals
PublicationA laboratory stand for wideband analysis radiocommunication signals is presented in the paper. The stand is designed for signals acquisition in wide spectrum and research a field of digital signal processing. Procedures used for simultaneous acquiring many frequency channels in selected wide band are described. The method of detection of direct sequence spread spectrum signals (DS SS) which power spectral density is lower than...
-
The influence of small amount of substances present in tissue on the optical spectrum of immunosuppressive drug
PublicationIn this paper, we describe how commonly present in tissue substances - sodium chloride and glucose - affect the optical spectrum of an immunosuppressive drug (Cyclaid® by Apotex). Prepared samples were investigated using the spectrophotometer in the spectrum range from 250 nm to 1100 nm. The maximum wavelength shift calculated on the basis of measurement results is not bigger than the measurement wavelength step. So, it can be...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 2 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Dynamic analysis of lightweight structure of the Viaduct Millau in France subjected to the wind fluctuations described by Karman’s and Davenport’s spectrum
PublicationThe article presents numerical simulations for wind impact modelling on the Millau Viaduct structure in France performed with two independent spectrum generation methods. The viaduct's construction in affected by strong forces, as it is situated in the Tarn river's valley. Thus, the loading coming from the wind cannot be modelled, the way it is in case of simple structures as static loading, but as a loading in a form of a spectrum...
-
The role of Herzberg-Teller effects on the resonance Raman spectrum of trans-porphycene investigated by time dependent density functional theory.
PublicationThe S1 excited state properties as well as the associated absorption and resonance Raman (RR) spectra of trans-porphycene are investigated by means of time dependent density functional theory calculations. The relative magnitude of the Franck-Condon (FC) contribution and of the Herzberg-Teller (HT) effects is evaluated for both the absorption and RR intensities. The accuracy of the calculated spectra is assessed by employing different...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 200 mV
Open Research DataThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 0 V
Open Research DataThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 600 mV
Open Research DataThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing impedance analyzer with potentiostat using RC model with Si diode at 400 mV
Open Research DataThe dataset presents impedance spectrum non-linear RC model with diode presented in the figure below. This model was used as a test engine of the impedance analyzer with potentiostat described in the referenced paper. When changing the DC polarisation of the model the non-linear phenomena could be observed. Thanks to this, the model can be used as a...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 3 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on "unknown" object using 2-wire probe
Open Research DataThe dataset presents impedance spectrum of "black-box" object with interesting phase characteristics. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Calibration images under different lighting conditions vol. 2
Open Research DataDataset description: Calibration images under different lighting conditions vol. 1
-
Diagnosis of bearing damage in induction motors by instantaneous power analysis
PublicationResearch of the machine with simulated bearing damages has been carried out, where variable load torque, simulating bearing damage, was introduced. The results show that components which can be used for bearings diagnosis appear in the spectrum of the product of current and supply voltage instantaneous values. These components are easier to identify than the components of current spectrum, which have been used so far in diagnostic...
-
Color prediction from first principle quantum chemistry computations: a case of alizarin dissolved in methanol
PublicationThe electronic spectrum of alizarin (AZ) in methanol solution was measured and used as reference data for color prediction. The visible part of the spectrum was modelled by different DFT functionals within the TD-DFT framework. The results of a broad range of functionals applied for theoretical spectrum prediction were compared against experimental data by a direct color comparison. The tristimulus model of color expressed in terms...
-
Valence and Ionic Lowest-Lying Electronic States of Isobutyl Formate Studied by High-Resolution Vacuum Ultraviolet Photoabsorption, Photoelectron Spectroscopy, and Ab Initio Calculations
PublicationThe highest resolution vacuum ultraviolet photoabsorption spectrum of isobutyl formate, C5H10O2, yet reported is presented over the energy range 4.5−10.7 eV (275.5−118.0 nm) revealing several new spectral features. Valence and Rydberg transitions and their associated vibronic series observed in the photoabsorption spectrum have been assigned in accordance with new ab initio calculations of the vertical excitation energies and oscillator...
-
Wavelet-based denoising method for real phonocardiography signal recorded by mobile devices in noisy environment
PublicationThe main obstacle in development of intelligent autodiagnosis medical systems based on the analysis of phonocardiography (PCG) signals is noise. The noise can be caused by digestive and respiration sounds, movements or even signals from the surrounding environment and it is characterized by wide frequency and intensity spectrum. This spectrum overlaps the heart tones spectrum, which makes the problem of PCG signal filtrating complex....
-
Examination of Spectral Properties of Medicinal Plant Leaves Grown in Different Lighting Conditions Based on Mint Cultivation
PublicationCultivation in controlled environmental conditions can provide good quality medicinal herbs with consistent properties. A sensing system that can determine the contents of medicinal substances in plants using spectral characteristics of leaves would be a valuable tool. Viability of such sensing approach for mint had to be confirmed experimentally, as no data correlating contents of medicinal substances with spectral characteristics...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Electrochemical cell impedance spectra at Eoc+100mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc+200mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on polyvinyl coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of polyvinyl coating (code-name PW_2_2_1) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of nano-nickel based coating sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 2
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 1
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Electrochemical cell impedance spectra at Eoc-100mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on nano-nickel based coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of nano-nickel based coating sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement range of...
-
Electrochemical cell impedance spectra at Eoc
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-200mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
XPS-Ni foam as received, after photocatalysis and after oxidation at 500_C.
Open Research DataThis dataset contains XPS spectra recorded for nickel foam as received from supplier, after photocatalytic process and after oxidation at 500C. Each set contains: survery spectrum, O1, C1s, Ni2p. The detailed equipment and measurement data was described in "readme XPS.txt" file
-
Topological degree for equivariant gradient perturbations of an unbounded self-adjoint operator in Hilbert space
PublicationWe present a version of the equivariant gradient degree defined for equivariant gradient perturbations of an equivariant unbounded self-adjoint operator with purely discrete spectrum in Hilbert space. Two possible applications are discussed.
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 2
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 2. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 1
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name B2_B3) sample 1. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Testing HIADAC high impedance analyzer in cooperation with Road and Bridge Research Institute on epoxy based coating using 2-wire probe sample 3
Open Research DataThe dataset presents impedance spectrum of epoxy based coating (code-name EPCS1) sample 3. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (0.1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Analytical studies of spectrum broadcast structures in quantum Brownian motion
PublicationSpectrum broadcast structures are a new and fresh concept in the quantum-to-classical transition, introduced recently in the context of decoherence and the appearance of objective features in quantum mechanics. These are specific quantum state structures, responsible for the objectivization of the decohered state of a system. Recently, they have been demonstrated by means of the well-known quantum Brownian motion model of the recoilless...
-
Dynamical objectivity in quantum Brownian motion
PublicationClassical objectivity as a property of quantum states —a view proposed to explain the observer-independent character of our world from quantum theory, is an important step in bridging the quantum-classical gap. It was recently derived in terms of spectrum broadcast structures for small objects embedded in noisy photon-like environments. However, two fundamental problems have arisen: a description of objective motion and applicability...
-
Distance measurement by the low coherent interferometer with NND layer (the source wavelegth 1310 nm)
Open Research DataThe obtained data was acquired by the interferometric fiber-optic sensor of distance. The setup was constructed of a broadband light source working at the central wavelength of 1310 nm, an optical spectrum analyzer, and a fiber-optic 2x1 coupler (with the power split 50:50). All elements were connected by standard single-mode optical fibers. The measurement...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 75 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 65 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 90 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 80 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 45 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 35 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 50 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 70 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapasitor with the use of ZnO coated microsphere-based fiber-optic sensor - 30 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 60 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 40 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 85 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Temperature measurement of supercapacitor with the use of ZnO coated microsphere-based fiber-optic sensor - 55 Celsius degrees
Open Research DataApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements of supercapasitor, is presented. Internal temperature of the supercapacitor is investigated in the range between 30°C and 90°C. The supercapacitor temperature was investigated using...
-
Spectral reflectance modeling of ZnO layers made with Atomic Layer Deposition for application in optical fiber Fabry-Perot interferometric sensors
PublicationSuitability of zinc oxide (ZnO) layers grown using Atomic Layer Deposition for operation in optical-fiber extrinsic Fabry-Perot sensors is investigated using a numerical model. Reflectance spectra obtained using the developed model indicate that the application of these layers in optical-fiber extrinsic Fabry-Perot sensors is difficult as it may require a source whose spectrum width is about 300 nm. A series of ZnO layers grown...
-
Multispectral impedance quality testing of coil-coating system using principal component analysis
PublicationThe task of quality checking of the coil-coated system was undertaken using impedance spectroscopy. In order to properly characterize the system the new impedance spectrum was calculated as an averaged result of 12 experimental spectra obtained from 12 different places of the sample at the same time of immersion in 3% of NaCl. The experimental spectra were recorded for a 24-h period at 1 h intervals between starting points of each...
-
An optimal form of the finite element mass matrix in the analysis of longitudinal vibrations of rods
PublicationIn this paper, an attempt is made to find the optimal form of the mass matrix of a rod finite element, which allows one to obtain the smallest errors in the longitudinal frequency determination of natural vibrations of any boundary conditions within the whole range of determined frequencies. It is assumed that the mass matrix can be treated as a linear combination of the consistent and diagonal matrices. Based on analytical considerations,...
-
Selection of excitation signals for high-impedance spectroscopy
PublicationA method of fast impedance spectroscopy of technical objects with high impedance (|Zx| > 1 GOhm) is evaluated in this paper. An object is excited with a signal generated by a digital-to-analog converter (DAC) located on the U2531A DAQ module. Response signals proportional to current flowing through and voltage across the measured object are sampled by analog-to-digital converters (ADC) in the DAQ module. The object impedance spectrum...
-
Instantaneous power signal measurements for bearing diagnostics
Open Research DataBearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous current and voltage power supplied to the engines. Bearing damage causes the appearance of deformations, which are in the form of additional harmonic components...
-
Analysis of the instantaneous power signal for bearing diagnostics -bearing damaged
Open Research DataThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of a damaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Analysis of the instantaneous power signal for bearing diagnostics - bearing undamaged
Open Research DataThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of an undamaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Theory and application of Near-infrared spectroscopy
PublicationIn recent years one can observe a significant increase in the requirements on quality control in all industrial sectors. The growing number of involved analyses makes the traditional, time consuming, requiring use of large quantities of reagents, thus expansive methods inconvenient especially for industrial applications. Fortunately, there is a very fast, cheap and not invasive analytical method that is increasingly used in qualitative...
-
Comparative Evaluation of Multicoil Inductive Power Transfer Approaches Based on Z-source Network
PublicationThis paper describes comparative evaluation between wireless power transfer topologies with utilization of Z-source network. Paper describes components calculation method. List of open-loop, close-loop simulations were conducted to compare both topologies. Spectrum of signals is also researched.
-
Effect of waviness and roughness components on transverse profiles of turned surfaces
PublicationThis paper presents the authors method of simultaneous analysis of roughness and waviness irregularity components, with the aim of better defining the key qualities and characteristics.Periodical surface machining traces may be analyzed spectrally, with the irregularity's peaks and troughs being used to define the wave's amplitude.In this work the standard composition for filtering waviness and roughness components of a surface...
-
Detection system for optical coherence tomography: Czerny-Turner spectrometer
PublicationResearch methods based on spectral analysis have powerful impact on development in many field of science. Signal spectrum can be a source of useful and important data. It enables to obtain information about physical and chemical properties of tested materials. This paper has been devoted to describe optical design for high resolution spectrometer, which is significant element of optical coherence tomography (OCT) systems. Designed...
-
Lamp of adjustable spectrum for photographic usage
PublicationPhotography is a unique rapidly growing interdisciplinary field encompassing aspects of science, art and technology. Expectations of photographers are steadily increasing with the development of technology. One of the areas playing a crucial role in photography is lighting. Consequently, several types of light sources for photographic use have been developed. The ongoing research in this field concentrates on lamps with tunable...
-
Fiber-optic Fabry-Pérot sensors – modeling versus measurements results
PublicationThis paper describes how parameters of investigated substances and the fiber-optic Fabry-Pérot sensing interferometer affect the spectrum of the optical radiation at the output of the sensor. First, the modeling of the operation of the sensing interferometer was conducted. Most important parameters and effects that were taken into account are: dependences of the refractive indices of the core and the cladding, as well the mode...
-
Dependence of biological sensing on temperature based on investigation of SARS-CoV-2
Open Research DataPresented dataset is the result of an investigation of the attachment of SARS-CoV-2 specific IgG in the temepratures relevant in biology. The samples were measured during a period of 15 minutes, at 5°C, 25°C and 55°C. The measurements were performed using the microspher-based fiber-optic sensor, as an interferometer. The broadband optical light source...
-
Unusual Influence of Fluorinated Anions on the Stretching Vibrations of Liquid Water
PublicationInfrared (IR) spectroscopy is a commonly used and invaluable tool in the studies of solvation phenomena in aqueous solutions. Concurrently, ab initio molecular dynamics (AIMD) simulations deliver the solvation shell picture at a molecular detail level and allow for a consistent decomposition of the theoretical IR spectrum into underlying spatial correlations. Here, we demonstrate how the novel spectral decomposition techniques...
-
The electronic excited states of dichloromethane in the 5.8-10.8 eV energy range investigated by experimental and theoretical methods
PublicationWe present a comprehensive experimental high-resolution vacuum ultraviolet (VUV) photoabsorption spectrum of dichloromethane, CH 2 Cl 2 , with absolute cross sections determined for the full 5.8–10.8 eV energy-range. The calculations on the vertical excitation energies and oscillator strengths were performed using the equation-of-motion coupled cluster method, restricted to the single and double excitations level (EOM-CCSD), and...
-
MODELLING OF TOXIC COMPOUNDS EMISSION IN MARINE DIESEL ENGINE DURING TRANSIENT STATES AT VARIABLE PRESSURE OF FUEL INJECTION
PublicationTransient states are an important part of the spectrum of engine loads, especially the traction engines. In the case of marine diesel engines, transient states are of particular importance in reducing the analysis of motion units for special areas and maneuvering in port, the participation of transient states in the load spectrum significantly increases, also, the emission of toxic compounds from this period increases proportionally....
-
Interactions of fish gelatin and chitosan in uncrosslinked and crosslinked with EDC films: FT-IR study
PublicationFilms based on fish gelatin, chitosan and blend of fish gelatin and chitosan before and after cross-linking with EDC have been characterized by FT-IR spectroscopy. The FT-IR spectrum of fish gelatin film showed the characteristic amide I, amide II and amide III bands, and the FT-IR spectrum of chitosan film confirmed that the polymer was only a partially deacetylated product, and included CH3-C=O and NH2 groups, the latter both...
-
Electronic structure and rovibrational predissociation of the 2^1Π state in KLi
PublicationAdiabatic potential energy curves of the 3^1Σ^+, 3^3Σ^+, 2^1Π and 2^3Π states correlating for large internuclear distance with the K(4s) + Li(2p) atomic asymptote were calculated. Very good agreement between the calculated and the experimental curve of the 2^1Π state allowed for a reliable description of the dissociation process through a small (∼20 cm−1 for J = 0) potential energy barrier. The barrier supports several rovibrational...
-
Investigating Feature Spaces for Isolated Word Recognition
PublicationThe study addresses the issues related to the appropriateness of a two-dimensional representation of speech signal for speech recognition tasks based on deep learning techniques. The approach combines Convolutional Neural Networks (CNNs) and time-frequency signal representation converted to the investigated feature spaces. In particular, waveforms and fractal dimension features of the signal were chosen for the time domain, and...
-
Narrowband Transmission Quality in Presence of Modified IEEE 802.15.4a Impulse Radio Interference
PublicationThis paper presents results of measurement of narrowband transmission quality in presence of impulse radio UWB interference. IEEE 802.15.4a UWB signal is being used as interferer, also with frame structure modifications which lead to change spectrum of the interference. Equations and coefficients which allow to calculate ratio between power of useful and interference signal are also presented.
-
Impedance spectra of ZnO varistor type 280 model O M ver. 89
Open Research DataThe impedance spectrum of high-voltage ZnO varistor obtained using FRA EIS impedance spectrosocpy measurement method. The 1V sinusoidal excitation was used. The frequency range was chosen from 10 kHz down to 100 uHz. The object under test and the measuring instrument were placed in a Faraday cage due to high impedance of the object. The data was acquired...
-
Frequency response spectra applied to assess efficiency of the training techniques
PublicationThe purpose of the research is to assess the increase of the muscle strength and power. Movement of the human body when the moving one impacts a stationary or moving body is taken under consideration. The waveform produced by an impact is transformed into frequency domain. The acceleration record is transformed as a complex spectrum, by the use of a Discrete Fourier Transformation. In this paper the applications of the discrete...
-
Objectivity in the non-Markovian spin-boson model
PublicationObjectivity constitutes one of the main features of the macroscopic classical world. An important aspect of the quantum-to-classical transition issue is to explain how such a property arises from the microscopic quantum theory. Recently, within the framework of open quantum systems, there has been proposed such a mechanism in terms of the so-called spectrum broadcast structures. These are multipartite quantum states of the system...
-
Multi-mode vibronic interactions in the five lowest electronic states of the fluorobenzene radical cation
PublicationThe multi-mode vibronic interactions between the five lowest electronic states of the fluorobenzene radical cation are investigated theoretically, based on ab initio electronic structure data, and employing the linear vibronic coupling model. Low-energy conical intersections, and strong vibronic couplings are found to prevail within the set of X-A and B-C-D cationic states, while the interactions between these two sets of states...
-
Equitable and semi-equitable coloring of cubic graphs and its application in batch scheduling
PublicationIn the paper we consider the problems of equitable and semi-equitable coloring of vertices of cubic graphs. We show that in contrast to the equitable coloring, which is easy, the problem of semi-equitable coloring is NP- complete within a broad spectrum of graph parameters. This affects the complexity of batch scheduling of unit-length jobs with cubic incompatibility graph on three uniform processors to minimize...
-
Polyethylene glycol-coated solid-phase microextraction fibres for the extraction of polar analytes-A review
PublicationThe article discusses the merits and limitations of commercially available solid-phase microextraction (SPME) fibres and compares them with the new type of extraction coatings, in particular those containing polyethylene glycol as sorbent, as well as the methods of the preparation of the latter. It also analyses their possible application for the extraction of a broad spectrum of analytes, with particular emphasis on the sampling...
-
Detection of the Direct Sequence Spread Spectrum Signals with BPSK Modulation
PublicationThis paper presents a method of the DS CDMA signals with BPSK modulation detection through the examination of the enhanced signal spectrum density. On the base of experiments carried out on the real radio communication signals the impact of a narrowband emission occurring in the examined frequency band on the detection process effectiveness was shown. The results of the experiment aimed at the detection of the satellite navigation...
-
Identification of inherent noise components of semiconductor devices on an example of optocouplers
PublicationIn the paper, a method of estimation of parameters of Gaussian and non-Gaussian components in the noise signal of semiconductor devices in a frequency domain is proposed. The method is based on composing estimators of two spectra, corresponding to noise (Gaussian component) and two-level RTS noise (non-Gaussian component). The proposed method can be applied for precise evaluation of the corner RTS frequency fRTS in the noise...
-
MAGNETOACOUSTIC HEATING AND STREAMING IN A PLASMA WITH FINITE ELECTRICAL CONDUCTIVITY
PublicationNonlinear effects of planar and quasi-planar magnetosound perturbations are discussed. Plasma is assumed to be an ideal gas with a finite electrical conductivity permeated by a magnetic filed orthogonal to the trajectories of gas particles. the excitation of non-wave modes in the filed of intense magnetoacoustic perturbations, i.e., magnetoaciustic heating and streaming, is discussed. The analysis includes a derivation if instantaneous...
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
PublicationIn this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing...
-
Broadening the scope of measurement and analysis of vibrations of an organ pipe employing intensity probe, simulations, and highspeed camera
PublicationThis paper shows an integrated approach to measure, analyze, and model phenomena occurring in an organ pipe driven by pressurized air. The aim of this paper is two-fold, i.e., to measure the pressure signal and the intensity field around the mouth by means of an intensity probe and to visualize and observe the motion of the air jet, which represents the excitation mechanism of the system. This is realized through two techniques,...
-
Ontology as a Tool for the IT Management Standards Support
PublicationIn this paper the authors discuss the initial idea of using ontologies to model requirements of the standards that support IT management processes. The Open Group Architecture Framework (TOGAF) is set as an example. A need for transition from the generic model do the organization-specific one is indicated. The described example serves as a ground for considering the usefulness of such modeling approach in the wider spectrum of...
-
Studies on optical transmittance of boron-doped nanocrystalline diamond films
PublicationThickness is one of the most important parameters in many applications using thin layers. This article describes thickness determination of a boron-doped nanocrystalline diamond (NCD) grown on fused silica glass. A spectroscopic measurement system has been used. A high refractive index (2.3 at 550nm) was achieved for NCD films. The thickness of NCD samples has been determined from the transmission spectrum.
-
Programmable dynamically changing RC model for evaluation of Dynamic EIS methods and instrumentation
PublicationThe paper concerns the RC equivalent circuit of electrochemical cell with the impedance changed during the experiment. The model was constructed using the digital potentiometers controlled by the microcontroller. This solution allows to control the model impedance by the software means. By creating adequate changes of the impedance spectrum as a time function, the different impedance measurement method can be tested to find out...
-
Selected issues on the role of electric lighting in the regeneration programs of urban spaces in Poland
PublicationThis paper reflects on the basic research done in the area of outdoor public lighting in regard to regeneration processes. The general purpose of this scientific paper is to investigate the role that lighting design plays within regeneration frameworks. Referring to a wide spectrum of academic publications, the paper provides an overview of regeneration and outdoor public lighting objectives. Emphasize is put on the obstacles for lighting...
-
Lighting design for urban revitalization. The case of Poland
PublicationThis paper reflects on the basic research done in the area of public lighting in regard to revitalization processes. The general purpose of this scientific paper is to research a role of an implementation of public lighting design within revitalization frameworks. Referring to a wide spectrum of academic publications, the paper provides an overview of revitalization and public lighting objectives. The emphasize is put on a need...
-
Direct spectrum detection based on Bayesian approach
PublicationThe paper investigates the Bayesian framework's performance for a direct detection of spectrum parameters from the compressive measurements. The reconstruction signal stage is eliminated in by the Bayesian Compressive Sensing algorithm, which causes that the computational complexity and processing time are extremely reduced. The computational efficiency of the presented procedure is significantly...
-
Independent dynamics of slow, intermediate, and fast intracranial EEG spectral activities during human memory formation
PublicationA wide spectrum of brain rhythms are engaged throughout the human cortex in cognitive functions. How the rhythms of various low and high frequencies are spatiotemporally coordinated across the human brain during memory processing is inconclusive. They can either be coordinated together across a wide range of the frequency spectrum or induced in specific bands. We used a large dataset of human intracranial electroencephalography...
-
The Use of Wavelet Analysis to Denoising of Electrocardiography Signal
PublicationThe electrocardiography examination, due to its accessibility and simplicity, has an important role in diagnostics of the heart ailments. It enables quick detection of various heart defects, undetectable by other kinds of diagnostic tools, so it is very popular. Nevertheless, the measured signal is exposed to a different disturbances. Among them, the electromagnetic interferences, drift of reference electrode and high frequency...
-
Role of nitrogen in evolution of sp2/sp3 bonding and optical band gap in hydrogenated carbon nitride
PublicationDrastic changes in the bonding are found in amorphous hydrogenated carbon nitride (a-CNx:H) film as a function of nitrogen concentration (or N/C ratio). The total C-sp3 fraction and hardness shows a sharp decrease (at N/C = 0.40) whereas optical band gap and resistivity shows a gradual increase as nitrogen concentration increases from 0.07 to 0.58. Raman spectrum of a-CNx:H film is fitted with both Gaussian (integrated intensity...
-
Influence of orientational disorder on the optical absorption properties in hybrid metal‐halide perovskite CH3NH3PbI3. A combined DFT/TD‐DFT and experimental study.
PublicationAn experimental and theoretical investigation is reported to analyze the relation between the structural and absorption properties of CH3NH3PbI3 in the tetragonal phase. More than 3000 geometry optimizations were performed in order to reveal the structural disorder and to identify structures with the lowest energies. The electronic structure calculations provide an averaged band gap of 1.674 eV, which is in excellent agreement...
-
Identification of hydroacoustic wave sources of ship in motion
PublicationThis paper deals with results of identification tests of acoustic field spectrum of underwater noise generated by ship in motion. The field is connected with acoustic activity of ship mechanisms and devices in operation. Vibration energy generated by the mechanisms and devices is transferred through ship structural elements to surrounding water where it propagates in the form of acoustic waves of a broad band of frequencies. In...
-
Current trends in solid-phase microextraction (SPME) fibre catings
PublicationThis critical review presents information on known and innovative approaches to the manufacture of fibre coatings used in solid-phase microextraction (SPME). The properties, advantages and drawbacks of the different types of commercially available SPME fibre coatings are discussed in detail, as are those of novel types of coatings and the methodologies of their preparation. The applications of fibre coatings in the solid-phase...
-
Problems of Determination of Welding Angular Distortions of T-fillet Joints in Ship Hull Structures
PublicationShip hull structure elements are in majority joined by welding. Welding distortions can cause a lot of problems during the manufacturing process. In the literature it is proposed wide spectrum of suggestions for a correct estimation of welding deformation in particular angular deformation in the fillet welded T joint. In the work verification of selected methods is proposed basing upon of the results of the laboratory measurements....
-
Simulation of influence of the air gap asymmetryon voltage waveforms of a synchronous machine
PublicationResults of simulation of a synchronous generator with the air gap asymmetry characterised by eccentricity are presented in the paper. The Lagrange's energy method has been used in derivation of the model equations. Analysis of influence of the air gap asymmetry on characteristics of self and mutual inductances of windings, as well as analysis of induced voltage waveforms as a function of the air gap asymmetry have been performed....
-
Wideband Signal Generation for Jamming Radio-Controlled Improvised Explosive Devices
PublicationThis paper focuses on modelling operation of a wideband jamming signal generator, considering the effects present in real device which influence the shape of transmitted signal’s spectrum. Introduction is followed by a brief overview of AEGIS project, aim of which is to develop a mobile generator of electromagnetic curtain. Next, simulation model is described which includes the factors...
-
A study of the photoelectron spectra of α-tetrahydrofurfuryl alcohol over the outer valence energy region (9–25 eV)
PublicationPhotoelectron spectra of α-tetrahydrofurfuryl alcohol (THFA) molecules, the threshold spectrum and spectra for constant photoelectron energies, have been measured over the photon energy range 9–25 eV. Analysis of the photoelectron spectra has allowed overlapping photoionization bands to be separated, tentatively assigned and their vertical photoionization energies to be determined. These energies are compared with existing theoretical...
-
Effect of temperature change on refractive index of an egg white and yolk: a preliminary study
PublicationIn this article, the refractive index of an egg white and yolk depending on temperature in range 30 - 47 °C over 1550 nm was determined. The measurement head was constructed as fiber optic Fabry-Perot interferometer with interference between polished fiber end-face and aluminum weighing dish. The measurement setup has been made of an optical spectrum analyzer, a superluminescent diode with a central wevelength of 1550 nm, 2:1 fiber...
-
Evaluation of Response Amplitude Operator of Ship Roll Motions Based on the Experiments in White Noise Waves
PublicationEvaluation of the response amplitude operator (RAO) function for ship wave frequency motions by means of scale model tests in regular waves is a standard procedure conducted by hydrodynamic model testing institutions. The resulting RAO function allows for evaluating sufficiently reliable seakeeping predictions for low to moderate sea states. However, for standard hull forms, correct prediction of roll motion in irregular wave (and...