Filters
total: 3463
filtered: 2418
displaying 1000 best results Help
Search results for: photonic measurements, interferometer
-
Measuring and Analyzing Audio Levels in Film, Commercials, and Movie Trailers Using Leq(A) Values and the LUFS Loudness Model . Analiza pomiarów dźwięku w filmie oraz w reklamach filmowych z wykorzystaniem modelu głośności
PublicationThe purpose of this paper is to describe the measurement of loudness levels in movies, movie trailers, and commercials displayed before feature films at movie theaters. In the initial section, the paper discusses the issues related to measurement of loudness levels, provides recommendations regarding permissible loudness levels during movie screenings, and mentions the applied units of measurement. The following section of the...
-
Modelling of Diffusing Capacity Measurement Results in Lung Microangiopathy Patients. A novel Diagnostic Suppport
PublicationLung microangiopathy is a little known negative influence of diabetes mellitus on the functioning of the lungs. The aim of this study is to design a supportive method for diagnosing lung microangiopathy. This will be based on routinely performed pulmonary measurements as well as on investigation process modelling and data processing. A model of the diffusion of oxygen from the alveoli to the blood has been described with a set...
-
Estimation of the angular position of a two-wheeled balancing robot using a real IMU with selected filters
PublicationA low-cost measurement system using filtering of measurements for two-wheeled balancing robot stabilisation purposes has been addressed in this paper. In particular, a measurement system based on gyroscope, accelerometer, and encoder has been considered. The measurements have been corrected for deterministic disturbances and then filtered with Kalman, α-β type, and complementary filters. A quantitative assessment of selected filters...
-
Fast Fading Influence on the Deep Learning-Based LOS and NLOS Identificationin Wireless Body Area Networks
PublicationIn the article, the fast fading influence on the proposed DL (Deep Learning) approach for LOS (Line-of-Sight) and NLOS (Non-Line-of-Sight) conditions identification in Wireless Body Area Networks is investigated. The research was conducted on the basis of the off-body communication measurements using the developed mobile measurement stand, in an indoor environment for both static and dynamic scenarios. The measurements involved...
-
Intelligent equalizer solution employing music genre and the room characteristics analysis
PublicationThe paper presents an intelligent equalizer solution based on room acoustic conditions and music genre analysis. A series of acoustic characteristic measurements are performed for checking the concept proposed. White noise (reference signal) and audio excerpts belonging to six music genres are utilized as excitation signals in measurements. This results in registration of frequency responses of rooms and reverberation times. Signals...
-
Suitability of LoRaWAN Technology for the Development of Maritime Applications
PublicationThe LoRaWAN Technology opens new possibilities for gathering and analysis of distributed data. In the paper we concentrate on its maritime usability which was tested by us in the period from June to August 2018. Measurements of the LoRaWAN network coverage in the Bay of Gdansk area were carried out. Various conditions and places were tested. The research was planned in such a way as to gradually increase the range and control the...
-
LDFEM analysis of pore water pressure development in cohesive soil due to FDP auger drilling
PublicationThis paper presents the preliminary modelling of FDP auger drilling in soft soil with emphasis on excess pore water pressure (EPWP) development using CEL formulation and Abaqus software suit. The EPWP generation in single points is investigated and the results of a numerical analysis are compared with the field measurements. It is found that numerical model qualitatively reflects the field measurements. However,...
-
Influence of the Delay in Monitor System on the Motor Coordination of Musicians while Performing
PublicationThis paper provides a description and results of measurements of the maximum acceptable value of delay tolerated by a musician, while playing an instrument, that does not cause de-synchronization and discomfort. First, methodology of measurements comprising audio recording and a fast camera is described. Then, themeasurement procedure for acquiring the maximum value of delay conditioning...
-
Electrohydrodynamic Secondary Flow and Particle Collection Efficiency in a One-sided Spike-plate Type Electrostatic Precipitator
PublicationIn this work, results of electrohydrodynamic secondary flow and particle collection efficiency measurements in an electrostatic precipitator under positive and negative voltage polarity are presented. The electrostatic precipitator had two plate collecting electrodes and a single spike discharge electrode. The spike tips were only on one side of the discharge electrode, therefore called a one-sided spike electrode. The electrohydrodynamic...
-
Usefulness of chest perfusion computed tomography in the diagnosis of diabetic pulmonary microangiopathy
PublicationThis paper presents the usefulness of perfusion computed tomography (pCT) in the diagnosis of diabetic pulmonary microangiopathy. Our previous works have shown that perfusion parameters are useful in the diagnosis of diabetic pulmonary microangiopathy. We are looking for such measurements and perfusion parameters that provide the most accurate diagnosis. Two types of comparison were made based on the results of clinical trials:...
-
The data exchange between smart glasses and healthcare information systems using the HL7 FHIR standard
PublicationIn this study we evaluated system architecture for the use of smart glasses as a viewer of information, as a source of medical data (vital sign measurements: temperature, pulse rate, and respiration rate), and as a filter of healthcare information. All activities were based on patient/device identification procedures using graphical markers or features based on visual appearance. The architecture and particular use cases were implemented...
-
Effect of cobalt addition on the corrosion behaviorof near equiatomic NiTi shape memory alloy in normal saline solution: electrochemical and XPS studies
PublicationThe electrochemical and corrosion (uniform and localized) behavior of a binary Ni52Ti48 shape memory alloy (SMA) and two ternary Ni52Ti48-xCox (x = 1.5 and 4.0 wt.%) SMAs were studied. Measurements were conducted in 0.9% NaCl solution at 37 oC employing various electrochemical methods. These include: linear polarization resistance (LPR), linear sweep voltammetry (LSV), chronoamperometry and dynamic electrochemical impedance spectroscopy...
-
Quantum privacy witness
PublicationWhile it is usually known that the mean value of a single observable is enough to detect entanglement or its distillability, the counterpart of such an approach in the case of quantum privacy has been missing. Here we develop the concept of a privacy witness, i.e., a single observable that may detect the presence of the secure key even in the case of bound entanglement. Then we develop the notion of secret-key estimation based...
-
Flicker Noise in Resistive Gas Sensors—Measurement Setups and Applications for Enhanced Gas Sensing
PublicationWe discuss the implementation challenges of gas sensing systems based on low-frequency noise measurements on chemoresistive sensors. Resistance fluctuations in various gas sensing materials, in a frequency range typically up to a few kHz, can enhance gas sensing by considering its intensity and the slope of power spectral density. The issues of low-frequency noise measurements in resistive gas sensors, specifically in two-dimensional...
-
Pomiary skuteczności hamowania w stacjach kontroli pojazdów
PublicationPrzeprowadzono pomiary skuteczności hamowania w warunkach różnych stacji kontroli pojazdów. Celem przedsięwzięcia było porównanie wyników z uzyskanych pomiarów. Na tej podstawie pozyskano dane umożliwiające opracowanie założeń do koncepcji metodyki badań technicznych pojazdów zabytkowych w stacjach kontroli pojazdów.
-
Protection of bridges against stray current corrosion
PublicationA case study of Siennicki Bridge stray current corrosion hazard is presented. A corrosion risk was caused by incorrectly designed tram line traction which goes over the bridge. No dielectric insulation between running rails and bridge steel construction was used. A variety of protection methods against stray currents are described. Characteristics of the endangered bridge were described. Impressed current cathodic protection system...
-
Application of gpr method in diagnostics of reinforced concrete structures
PublicationThis paper presents an application of the ground penetration method (GPR) for diagnostics of reinforced concrete structures. In situ measurements were conducted for three civil engineering structures: the ground floor structure, the abutment of the railway viaduct and the concrete well. The dual polarized ground penetrating radar with the antenna operating at a center frequency of 2 GHz was used for GPR surveys. Three different...
-
Determination of Mechanical Properties of P91 Steel by Means of Magnetic Barkhausen Emission
PublicationIn this work, an attempt at determination of mechanical properties by means of a method based on magnetic Barkhausen emission measurements was proposed. The specimens made of P91 steel were subjected to creep or plastic flow which were interrupted after a range of selected time periods in order to achieve specimens with an increasing level of strain. Subsequently, measurements of magnetic Barkhausen emission were carried out, and...
-
Polypyrrole based gas sensor for ammonia detection
PublicationThe nature of polypyrrole response to toxic gases does not allow using the sensor in a conventional way. The main aim of this study is to acquire the information about the concentration using different approaches: a linear approximation, a non-linear approximation and a tangent method. In this paper a two-steps procedure for sensor response measurements has been utilized. Polypyrrole films were electrochemically synthesized on...
-
Porous Phantoms Mimicking Tissues – Investigation of Optical Parameter Stability Over Time
PublicationIn terms of optical parameters, optical phantoms can now replace live tissues and be used to validate optical measurement methods. Therefore, whether these parameters would be maintained after storage for 6 months was examined. The absorption and scattering coefficients were obtained from the measured transmittance and reflectance measurements taken 6 months apart and then compared. All of the measurements were conducted using...
-
Pre-oxidation of porous ferritic Fe22Cr alloys for lifespan extension at high-temperature
PublicationPre-oxidation of porous ferritic Fe22Cr alloys was extensively studied in this paper. Weight gain measurements and SEM analysis revealed that pre-oxidation performed at 900◦C for 40 min increased the lifespan of the alloy. A Cr evaporation study did not disclose any significant influence of the pre-oxidation process on the Cr content in the alloy. For a more detailed assessment, TEM imaging and X-ray tomography measurements of...
-
New kagome prototype materials: discovery of KV3Sb5, RbV3Sb5, and CsV3Sb5
PublicationIn this work, we present our discovery and characterization of a new kagome prototype structure, KV3Sb5. We also present the discovery of the isostructural compounds RbV3Sb5 and CsV3Sb5. All materials exhibit a structurally perfect two-dimensional kagome net of vanadium. Density-functional theory calculations indicate that the materials are metallic, with the Fermi level in close proximity to several Dirac points. Powder and single-crystal...
-
Time window based features extraction from temperature modulated gas sensors for prediction of ammonia concentration
PublicationElectronic gas recognition systems, in literature commonly referred as electronic noses, enable the recognition of a type and a concentration of various volatile compounds. Typical electronic gas-analyzing device consists of four main elements, namely, gas delivery subsystem, an array of gas sensors, data acquisition and power supply circuits and data analysis software. The commercially available metal-oxide TGS sensors are widely...
-
Phospholipid-functionalized gold electrode for cellular membrane interface studies - interactions between DMPC bilayer and human cystatin C
PublicationThis work describes the electrochemical studies on the interactions between V57G mutant of human cystatin C (hCC V57G) and membrane bilayer immobilized on the surface of a gold electrode. The electrode was modified with 6-mercaptohexan-1-ol (MCH) and 1,2-dimyristoyl-sn-glycero-3-phosphocholine (DMPC). DMPC was used as a membrane mimetic for monitoring electrochemical changes resulting from the interactions between the functionalized...
-
Long-term comparative evaluation of an acoustic climate in selected schools before and after the acoustic treatment
PublicationThe results of long-term continuous noise measurements in two selected schools are presented in the paper. Noise characteristics were measured continuously there for approximately 16 months. Measurements started eight months prior to the acoustic treatment of the school corridors of both schools. An evaluation of the acoustic climates in both schools, before and after the acoustic treatment, was performed based on comparison of...
-
A Thermographic Measurement Approach to Assess Supercapacitor Electrical Performances
PublicationThis paper describes a proposal for the qualitative assessment of condition of supercapacitors based on the conducted thermographic measurements. The presented measurement stand was accompanied by the concept of methodology of performing tests. Necessary conditions, which were needed to minimize the influence of disturbing factors on the performance of thermal imaging measurements, were also indicated. Mentioned factors resulted...
-
An NO2 sensor based on WO3 thin films for automotive applications in the microwave frequency range
PublicationA microwave system dedicated to the detection of nitrogen dioxide in the harsh environment of the Norway highways is proposed. An optimized transmission line type of sensor coated with a tungsten trioxide thin film that changes its electrical properties under NO2 gas exposure is developed. The sensors' response (S) is given in °/GHz and it is calculated based on wideband measurements. The advantage of wideband measurements in comparison...
-
Assessment of the Steering Precision of a Hydrographic Unmanned Surface Vessel (USV) along Sounding Profiles Using a Low-Cost Multi-Global Navigation Satellite System (GNSS) Receiver Supported Autopilot
Publicationhe performance of bathymetric measurements by traditional methods (using manned vessels) in ultra-shallow waters, i.e., lakes, rivers, and sea beaches with a depth of less than 1 m, is often difficult or, in many cases, impossible due to problems related to safe vessel maneuvering. For this reason, the use of shallow draft hydrographic Unmanned Surface Vessels (USV) appears to provide a promising alternative method for performing...
-
Lokalizacja osób w środowisku promu pasażerskiego z wykorzystaniem ultra szerokopasmowego interfejsu radiowego
PublicationW niniejszym artykule przedstawiono badania efektywności lokalizowania poruszających się osób w środowisku promu pasażerskiego stosując pomiar czasu propagacji ultraszerokopasmowego sygnału radiowego UWB (Ultra-Wide Band) pomiędzy węzłami odniesienia i terminalem ruchomym. Opisano zbudowane stanowisko badawcze oraz uzyskane wyniki pomiarów przeprowadzonych w warunkach rzeczywistych.
-
Application of Maximum-Length Sequences to impulse response measurement of hydroacoustic communications systems
PublicationThere is a growing interest in digital transmission of telemetry data on ultrasonic waves. The dependence of signal attenuation on squared frequency, specific to the hy-droacoustic systems, induces problems that do not exist in monochromatic, narrowband radio communications systems. For adapting the transmission parameters to current propagation conditions, a precise knowledge of instantaneous changes of channel performances is...
-
Electromagnetic interference frequencies prediction model of flyback converter for snubber design
PublicationSnubber design for flyback converters usually requires experimental prototype measurements or simulation based on accurate and complex models. In this study simplified circuit modelling of a flyback converter has been described to dimension snubbers in early stage of design process. Simulation based prediction of the transistor and diode ringing frequencies has been validated by measurements in a prototype setup. In that way obtained...
-
Application of auto calibration and linearization algorithms to improve sound quality of computer devices
PublicationAn application of auto calibration and linearization algorithms designed for correcting acoustic characteristics of selected computer devices was presented in the paper. The functionality of the algorithms were presented for two kind of computer devices: ultrabook class computer and portable device of All-In-One type. The algorithms were adjusted for the given type of the device on the basis of series of measurements conducted...
-
Tyre/road noise reduction of poroelastic road surface tested in a laboratory
PublicationA so-called poroelastic road surface (PERS) is being developed in Europe. This contains a large percentage of rubber particles mixed with hard aggregate (stone and sand) and bound with polyurethane. This gives high air void content (around 30 %), high elasticity and smooth texture, all of which should give low noise properties. Inthis experiment anominally 30 mm thick sample of PERS was mounted on a steel drum. Various car tyres...
-
Position Estimation in Mixed Indoor-Outdoor Environment Using Signals of Opportunity and Deep Learning Approach
PublicationTo improve the user's localization estimation in indoor and outdoor environment a novel radiolocalization system using deep learning dedicated to work both in indoor and outdoor environment is proposed. It is based on the radio signatures using radio signals of opportunity from LTE an WiFi networks. The measurements of channel state estimators from LTE network and from WiFi network are taken by using the developed application....
-
Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes
PublicationNon-invasive measurement methods offer great benefits in the field of medical diagnostics with molecular-specific techniques such as Raman spectroscopy which is increasingly being used for quantitative measurements of tissue biochemistry in vivo. However, some important challenges still remain for label-free optical spectroscopy to be incorporated into the clinical laboratory for routine testing. In particular, non-analyte-specific...
-
Reducing the Uncertainty of the Moving Object Location Measurement with the Method of Quasi-Multiple Measurement in GNSS Technology in Symmetrical Arrangement
PublicationThe article presents a solution to the problem of limited accuracy of dynamic measurements performed with GNSS receivers. The proposed measurement method is a response to the needs related to the assessment of the measurement uncertainty of the position of the track axis of the rail transport line. However, the problem of reducing the measurement uncertainty is universal for many different situations where high accuracy of positioning...
-
INVESTIGATION OF JOURNAL SLIDE BEARINGS UNDER THE ANGLE OF THEIR FUNCTIONING
PublicationPaper presents the structure and principle of operation of a stand for measurements of influence of the lubrication method and process on functioning of journal slide bearings in their various technical states. Measurements performed on the stand make it possible to take advantage of the new method of evaluating the influence of physical and chemical properties of lubricating oil on the coefficient of friction in the mixed friction...
-
Problems of Active Dynamic Thermography Measurement Standardization in Medicine
PublicationReliability of thermographic diagnostics in medicine is an important practical problem. In the field of static thermography, a great deal of effort has been made to define the conditions for thermographic measurements, which is now the golden standard for such research. In recent years, there are more and more reports on dynamic tests with external stimulation, such as Active Dynamic Thermography, Thermographic Signal Reconstruction...
-
Dual-wavelength polarimeter application in investigations of the optical activity of a langasite crystal
PublicationA method of high accuracy polarimetry, which includes optical activity measurements systematic errors, was realized with dual-wavelength polarimeter for two wavelengths of 635 and 650 nm. Simultaneous measurements with neighboring wavelengths significantly improved the data processing, by increasing the amount of data to eliminate the systematic errors. For langasite crystal La3Ga5SiO14 we measured temperature dependence of the...
-
Traffic Noise Analysis Applied to Automatic Vehicle Counting and Classification
PublicationProblems related to determining traffic noise characteristics are discussed in the context of automatic dynamic noise analysis based on noise level measurements and traffic prediction models. The obtained analytical results provide the second goal of the study, namely automatic vehicle counting and classification. Several traffic prediction models are presented and compared to the results of in-situ noise level measurements. Synchronized...
-
Inner-shell fragmentation of molecules into neutral fragments in high-Rydberg states induced by soft X-ray excitation with pulsed-field ionization
PublicationIn the present communication, we will show the results of measurements probing the production of neutral high-Rydberg fragments at the K edges of the molecules containing oxygen and nitrogen atoms. The experiments were performed at the Gas Phase beamline of the Elettra synchrotron radiation laboratory (Trieste, Italy), exploiting a combined soft X-ray excitation with pulsed-field ionization and ion time-of-flight (TOF) spectrometry...
-
Transformation of bimetallic Ag–Cu thin films into plasmonically active composite nanostructures
PublicationFormation of plasmonically active silver, copper and composite silver-copper nanostructures were studied in this paper. Metallic nanostructures were fabricated by thermal disintegration, so called dewetting, of the thin films in an argon atmosphere. The formation process of the nanostructures was in-situ observed by a novel method, based on resistance measurements. The influence of the material and thickness of the initial thin...
-
Liniowe i nieliniowe modele wielowymiarowej kalibracji do predykcji stężenia substancji z pomiarów woltamperometrycznych
PublicationPomiary woltamperometryczne znajdują zastosowanie w wielu dziedzinach nauki i techniki, np. w przemyśle farmaceutycznym. Dane uzyskane w wyniku takich pomiarów zawierają informację odnośnie rodzaju i stężenia badanej substancji, jednakże są one często kłopotliwe w bezpośredniej interpretacji. Z tego powodu, istnieje konieczność wykorzystania odpowiednich metod matematycznych, które umożliwiają uzyskanie bezpośredniej i precyzyjnej...
-
Analiza i ocena smarności olejów w ujęciu energetycznym i działania układu tribologicznego = Analysis and evaluation of oil lubricity from the viewpoint of energy apects and of the tribological system action
PublicationBased on measurement results, an interpretation is presented of the tribological system boundary layer action in the form of a four-ball tester friction node. The evaluation was performed of the boundary layer action understood as transfer of energy Ep resulting from loading the tribological system in a determined time t with work Lp, which may lead to breaking the boundary layer. That energy and time are the values unequivocally...
-
A XAS study of a highly diluted Pt electrocatalyst operating in PEM fuel cells
PublicationWe present an X-ray absorption spectroscopy (XAS) study of a low Pt content catalyst layer(Pt loading 0.1 mg c2) operating at the cathode of a proton exchange membrane fuel cell(PEMFC). This catalyst is based on the use of a mesoporous inorganic matrix as a support forthe catalyst Pt nanoparticles. Due to the high Pt dilution, in situ measurements of itsstructural properties by XAS are challenging and suitable experimental strategies...
-
Online urban acoustic noise monitoring system
PublicationConcepts and implementation of the Online Urban Noise Monitoring System are presented. Principles of proposed solution used for dynamic acoustical maps creating are discussed. The architecture of the system and the data acquisition scheme are described. The concept of noise mapping, based on noise source model and propagation simulations, was developed and employed in the system. Dynamic estimation of noise source parameters utilized...
-
Examining Acoustic Emission of Engineered Ultrasound Loudspeakers
PublicationMeasurement results of the sound emitted from an ultrasound custom-made system with high spatial directivity are presented. The proposed system is using modulated ultrasound waves which demodulate in nonlinear medium resulting in audible sound. The system is aimed at enhancing the users’ personal audio space, therefore the measurements are performed using the Head and Torso Simulator which provides the realistic reproduction of...
-
Rolling Resistance And Tire/Road Noise on Rubberized Asphalt Pavement In Poland
PublicationThe paper presents results of tire/road noise and rolling resistance measurements performed on stone-matrix asphalt (SMA) that contains rubberized asphalt developed and produced by the company in Poland. Bituminous binder was modified with polymer and additive of crumb rubber. First observations of asphalt mixture with the new kind of modified bitumen used on the field section are presented. Rolling resistance of passenger car...
-
Research on causes of corrosion in the municipal water supply system
PublicationThis paper presents results of failure analysis study to characterize the corrosion damage that occurred in the water supply system in Krakow. This analysis includes: electrochemical noise, linear polarization and resistometric measurements. Water aggressiveness of four water intakes was defined using Langelier and Ryznar indices. Results from this indices did not reveal the causes of considerable corrosion losses in water systems....
-
The Use of Free Adjustment and Msplit-Estimation for Determination of the Vertical Displacements in Unstable Reference System
PublicationThe problem of the determining of the displacements of engineering objects and their surroundings is the current and important issue in the field of engineering geodesy. Most control measurements are made in relation to reference points (stable points). On the other hand, sometimes it happens that it is not possible perform the measurements with reference to the stable points or identification of stable points is difficult. Therefore,...