Filters
total: 2103
-
Catalog
displaying 1000 best results Help
Search results for: OPTICAL FIBER SENSOR
-
Optical-Spectrometry-Based Method for Immunosuppressant Medicine Level Detection in Aqueous Solutions
PublicationIn this paper, an investigation into detecting immunosuppressive medicine in aqueous solutions using a spectrometry-based technique is described. Using optical transmissive spectrometry, absorbance measurements in the spectra range from 250 nm to 1000 nm were carried out for different cyclosporine A (CsA) concentrations in aqueous solutions. The experiment was conducted for samples both with and without interferent substances—glucose...
-
All solid state electrodes taste sensor with modified polymer membranes for discrimination of mineral water with different CO2 content
PublicationA potentiometric taste sensor with All Solid State Electrodes containing five all solid state electrodes with appropriate lipophilic compounds (benzyldimethyltetradecylammonium chloride, dodecyltrimethylammonium bromide, palmitic acid, stearic acid, and phytol) embedded in a polymer membrane was applied for discrimination of mineral water samples differed in CO2 content. Samples of still, slightly sparkling, and sparkling Naleczowianka...
-
Investigation of sweet substances of different molecular structure by potentiometric taste sensor with all solid state electrodes
PublicationA five channel potentiometric taste sensor consisting of an array of All Solid State Electrodes (ASSESs) with different lipid-polymer membranes has been developed. The electrodes are constructed of glassy carbon discs with electrochemically deposited poly(3,4-ethylenedioxythiophene) (PEDOT) acting as ion to electron transducer. The outer layer of the electrode is lipid-polymer membrane. Lipid substances immobilized in PVC membranes...
-
Optical and photoelectrochemical characterization of pulsed laser deposited Bi4V2O11, BICUVOX, and BIZNVOX
PublicationThin layers of three compounds from the BIMEVOX family (Bi4V2O11, Bi2V0.9Cu0.1O5.35, and Bi2V0.9Zn0.1O5.35) were prepared via pulsed laser deposition technique on quartz, silicon, and platinum foil and tested as photoanodes for water photooxidation. The film formation, as well as the crystallization upon heating, was characterized using X-ray diffraction and Raman spectroscopy. The optical properties were investigated using spectroscopic...
-
Brownian Motion in Optical Tweezers, a Comparison between MD Simulations and Experimental Data in the Ballistic Regime
PublicationThe four most popular water models in molecular dynamics were studied in large-scale simulations of Brownian motion of colloidal particles in optical tweezers and then compared with experimental measurements in the same time scale. We present the most direct comparison of colloidal polystyrene particle diffusion in molecular dynamics simulations and experimental data on the same time scales in the ballistic regime. The four most...
-
Thermally tuneable optical and electrochemical properties of Au-Cu nanomosaic formed over the host titanium dimples
PublicationAu-Cu nanostructures offer unique optical and catalytic properties unlike the monometallic ones resulting from the specific interaction. Among others, they have the ability to exhibit surface plasmon resonance, electrochemical activity towards the oxygen and hydrogen evolution reaction (OER, HER) as well as improved photoresponse in relation to monometalic but those properties depend highly on the substrate where bimetallic structures...
-
Tuning of the plasmon resonance location in Au nanostructures coated with a ultrathin film of Al2O3 – Optical measurements and FDTD simulations
PublicationThe Au nanostructures have been coated with an ultra-thin films of amorphous aluminium oxide. Optical absorption spectra show the influence of the thickness of Al2O3 on plasmon resonance wavelength. The observed red-shift of the resonance location with the increase of the thickness of the Al2O3 film, can be explained by the change in the dielectric function of this film. It allows control of the optical spectra of the coated particles....
-
Comment on "Quantitative comparison of analysis methods for spectroscopic optical coherence tomography"
PublicationIn a recent paper by Bosschaart et al. [Biomed. Opt. Express 4, 2570 (2013)] various algorithms of time-frequency signal analysis have been tested for their performance in blood analysis with spectroscopic optical coherence tomography sOCT). The measurement of hemoglobin concentration and oxygen saturation based on blood absorption spectra have been considered. Short time Fourier transform (STFT) was found as the best method for...
-
Statistical Data Pre-Processing and Time Series Incorporation for High-Efficacy Calibration of Low-Cost NO2 Sensor Using Machine Learning
PublicationAir pollution stands as a significant modern-day challenge impacting life quality, the environment, and the economy. It comprises various pollutants like gases, particulate matter, biological molecules, and more, stemming from sources such as vehicle emissions, industrial operations, agriculture, and natural events. Nitrogen dioxide (NO2), among these harmful gases, is notably prevalent in densely populated urban regions. Given...
-
Monte-Carlo Modeling of Optical Sensors for Postoperative Free Flap Monitoring
PublicationThis work aims to develop a numerical tissue model and implement software to simulate photon propagation using the Monte Carlo method to determine design guidelines for a physical measurement system. C++ was used for the simulation program, and Python as a programming environment to create an interface that allows the user to customize individual simulation elements, allowing for increased accuracy and flexibility when simulating...
-
Monte-Carlo Modeling of Optical Sensors for Postoperative Free Flap Monitoring
PublicationThis work aims to develop a numerical tissue model and implement software to simulate photon propagation using the Monte Carlo method to determine design guidelines for a physical measurement system. C++ was used for the simulation program, and Python as a programming environment to create an interface that allows the user to customize individual simulation elements, allowing for increased accuracy and flexibility when simulating...
-
Application of Potentiometric Taste Sensor with All Solid State Electrodes for Distinguishing of Red Dry Wines from Polish and French Vineyards
PublicationOpracowano nowy potencjometryczny czujnik smaku z sześcioma różnymi elektrodami typu All Solid State Electrode (ASSE). Każda z elektrod zawiera dwie warstwy: polimer przewodzący i membranę lipidowo-polimerową, w której rozpuszczone są poszczególne związki lipidowe. Potencjometryczny sensor smaku charakteryzuje się globalną selektywnością. Zastosowano go w celu odróżnienia próbek wytrawnych czerwonych win pochodzących z różnych...
-
The Influence of Camera and Optical System Parameters on the Uncertainty of Object Location Measurement in Vision Systems
PublicationThe article presents the influence of the camera and its optical system on the uncertainty of object position measurement in vision systems. The aim of the article is to present the methodology for estimating the combined standard uncertainty of measuring the object position with a vision camera treated as a measuring device. The identification of factors affecting the location measurement uncertainty and the determination of their...
-
Optical and chemical characterization of thin TiNx films deposited by DC-magnetron sputtering
PublicationThin titanium nitride (tinx) films were deposited on silicon substrates by means of a reactive dc-magnetron plasma. Layers were synthesized under various conditions of discharge power and nitrogen flows in two operation modes of the magnetron (the so-called "balanced" and "unbalanced" modes). The optical constants of the tinx films were investigated by spectroscopic ellipsometry (se). X-ray photoelectron spectroscopy (xps) was...
-
Soliton trapping and orthogonal Raman scattering in a birefringent photonic crystal fiber
Publication -
Characterization of fatty acids composition in the European beaver (Castor fiber L.).
PublicationW pracy przedstawiono zawartość lipidów , klas lipidów i skład kwasów tłuszczowych lipidów ogólnych uzyskanych z różnych tkanek bobra europejskiego (tkanka okołojelitowa, tkanka okołonerkowa, miesień uda, mięsień kreskowy, podskórna tkanka tłuszczowa, ogon). Wykazano różnice w zawartości lipidów i składzie KT w tkankach samic (n=7) i samców (n=3). Wykazano wysokie zawartości nienasyconych KT w tkankach bobrów w porównaniu z tkankami...
-
Quasi-Static and Dynamic Testing of Carbon Fiber Reinforced Magnesium Composites
Publication -
PROPERTIES OF FIBER REINFORCED CEMENT COMPOSITES WITH CENOSPHERES FROM COAL ASH
Publication -
FTIR Study and Mechanical Properties of Cellulose Fiber-Reinforced Thermoplastic Composites
Publication -
Advances In Atomic Molecular and Optical Physics
Journals -
International Journal of Microwave and Optical Technology
Journals -
JOURNAL OF NONLINEAR OPTICAL PHYSICS & MATERIALS
Journals -
Advanced Sensor for Non-Invasive Breast Cancer and Brain Cancer Diagnosis Using Antenna Array with Metamaterial-Based AMC
PublicationMicrowave imaging techniques can identify abnormal cells in early development stages. This study introduces a microstrip patch antenna coupled with artificial magnetic conductor (AMC) to realize improved sensor for non-invasive (early-stage) breast cancer and brain cancer diagnosis. The frequency selectivity of the proposed antenna has been increased by the presence of AMC by creating an additional resonance at 2.276 GHz associated...
-
Magnetoelectric, spectroscopic, optical and elastic properties of Co-doped BaTiO3 ceramics
Publicationhe BaTiO3 perovskite is widely used in the electronic technology due to its dielectric, piezoelectric and ferroelectric properties and is a well-known base for obtaining a promising multifunctional material. In this paper we report the extensive studies on the Co-doped BaTiO3 ceramics for the wide range cobalt content. Full structural characterization of studied samples in a 20–450 K range was provided. The results of research...
-
FFT analysis of temperature modulated semiconductor gas sensor response for the prediction of ammonia concentration under humidity interference
PublicationThe increasing environmental contamination forces the need to design reliable devices for detecting of the volatile compounds present in the air. For this purpose semiconductor gas sensors, which have been widely used for years, are often utilized. Although they have many advantages such as low price and quite long life time, they still lack of long term stability and selectivity. Namely, environmental conditions have significant...
-
Spectroscopic Optical Coherence Tomography for Thin Layer and Foil Measurements
PublicationThe main goal of this research was to assess if it is possible to evaluate the thickness of thin layers (both thin films on the surface and thin layers below the surface of the tested object) and foils using optical coherence tomography (OCT) for thickness assessment under the resolution of the standard commercially available OCT measurement system. In the proposed solution, light backscattered from the evaluated thin layer has...
-
Małgorzata Szczerska prof. dr hab. inż.
People -
Data from 76- to 81-GHz mmWave Sensor located at S7 road
Open Research DataThe set consists data recorded employing IWR1642 mmWave sensor from Texas Instruments. The purpose of the experiment was to detect vehicles and their speed in real conditions – at S7 road, near Dworek village (54°14'40.0"N 18°59'59.0"E).
-
Exploration of optical fibres as a carrier for new benzene and toluene matrix-free reference materials
PublicationTo meet high expectations concerning precision and accuracy of reference materials, preparation of matrixfree reference materials using thermal decomposition-gas chromatography-mass spectrometry (TD-GC-MS) was proposed in this study. In the paper, the results obtained in preparation of the new reference materials for benzene and toluene are presented, based on the thermal decomposition technique of compounds chemically bound to...
-
Analog multiplier for a low-power integrated image sensor
PublicationArtykuł przedstawia nowe podejście do projektowania tanich niskomocowych zintegrowanych sensorów optycznych. W odróżnieniu od wcześniej stosowanych rozwiązań opartych na masowym przetwarzaniu równoległym, zaproponowany mnożnik macierzowy charakteryzuje się korzystniejszymi cechami. Proponowane rozwiązanie, chociaż mniej elastyczne w sensie liczby możliwych do zaimplementowania algorytmów wstępnej obróbki obrazu, cechuje się znaczącą...
-
Wave propagation in a sensor/actuator diffusion bond model
Publication -
Localization in wireless sensor networks based on zigbee platform
PublicationW artykule porównano dwie różne metody lokalizacji w sieciach sensorów bezprzewodowych. Jedną z metod jest implementacja sprzętowa algorytmu w układzie nadawczo odbiorczym CC2431. Drugą metodą jest implementacja programowa. Wyniki testów przeprowadzonych na otwartym terenie oraz w pomieszczeniach zamkniętych zostały przedstawione i porównane w pracy.
-
<title>LabWindows: tool and environment for sensor design</title>
Publication -
Analytical characteristics of a new amperometric sulfur dioxide sensor
PublicationZaprojektowano i skonstruowano wyposażony w układ trójelektrodowy amperometryczny czujnik ditlenku siarki. Elektroda pracująca czujnika była napylona bezpośrednio na powierzchnię membrany. Zbadano charakterystyki czujnika z membranami z mikroporowatego Teflonu oraz Nafionu. Porównano parametry statyczne i dynamiczne tych czujników wypełnionych roztworami elektrolitów wewnętrznych, zawierających dodatek dimetylosulfotlenku.
-
Distributed Trust Management Model for Wireless Sensor Networks
Publication -
Analog multiplier for a low-power integrated image sensor
PublicationArtykuł przedstawia nowe podejście do projektowania tanich niskomocowych zintegrowanych sensorów optycznych. W odróżnieniu od wcześniej stosowanych rozwiązań opartych na masowym przetwarzaniu równoległym, zaproponowany mnożnik macierzowy charakteryzuje się korzystniejszymi cechami. Proponowane rozwiązanie, chociaż mniej elastyczne w sensie liczby możliwych do zaimplementowania algorytmów wstępnej obróbki obrazu, cechuje się znaczącą...
-
Pattern matching localization in ZigBee wireless sensor networks.
PublicationLokalizacja typu Pattern matching w sieciach sensorów bezprzewodowych ZigBee.Prezentacja metod implementacji algorytmów lokalizacji. Praktyczne zastosowanie i testowanie lokalizacji sieci ZigBee.
-
White-light interferometric temperature sensor for biomedical diagnostic.
PublicationW artykule opisano opracowany model miniaturowego, światłowodowego czujnika temperatury z interferometrem Fabry-Perot wykorzystującego interferencję światła białego przeznaczonego do zastosowań biomedycznych. Analizowano czujnik wykonany ze światłowodu wielomodowego o skokowym profilu współczynnika załamania oraz ze światłowodu monomodowego. Zasadniczym celem był dobór parametrów mający na celu uzyskania maksymalnej widzialności...
-
Electrical properties of polymer humidity sensor based on polyethyleneimine.
PublicationW pracy przedstawiono wyniki badań amperometrycznych właściwości czujników wilgotności na bazie PEI. Pokazano, że przepływ prądu jest wynikiem reakcji elektrodowej na anodzie.
-
Targed tracking with adaptive fusionof multiple sensor measurements.
PublicationW pracy przedstawiono metodę adaptacyjnej selekcji pomiarów z wielu radarów wykorzystywanych w procesie integracji pomiarów dla śledzenia obserwowanego obiektu. W przypadku dużego zróżnicowania dokładności pomiarów pochodzących z różnych radarów, rezultaty integracji pomiarów nie różnią się znacząco od wyników śledzenia opartego na pomiarach z najbardziej dokładnego źródła.
-
A model of the response of the MGS-6 gravity sensor to tilting
PublicationThe reliable interpretation of the measurements made by the Micro-g marine gravimetric system (MGS-6) depends on how the temporary changes of the scale coefficients such as gravimeter scale factor, vertical cross-coupling (VCC) effect, tiltmeter cross and tiltmeter long are compensated for during the signal analysis. The listed coefficients cannot be determined from readings during the measurements or by analysing the final data....
-
Trajectories detection in a distributed multi-sensor tracking system
PublicationW pracy rozważono problem śledzenia obiektów poruszających się za pomocą rozproszonego systemu wieloczujnikowego. Głównym zadaniem systemu śledzenia jest detekcja i estymacja trajektorii obiektów poruszających się w obserwowanej przestrzeni. Trajektoria obiektu to ciąg estymat kinematycznego stanu obiektu, jego pozycji, prędkości, itp. Klasyczne systemy śledzenia oparte są na filtrze Kalmana korzystającym z danych z pojedynczego...
-
Optimal placement of IMU sensor for the detection of children activity
PublicationIn this paper an investigation to determine the optimal placement of IMU sensors for the purpose of children characteristic activity detection is presented. The article compares four different placement of two IMU sensors on human body. Ten healthy volunteers participated within the study. Data were collected firstly from two wireless 9-axial IMU sensors placed at the left and right wrists, then sensors were placed at lower back...
-
Localization of sound sources with dual acoustic vector sensor
PublicationThe aim of the work is to estimate the position of sound sources. The proposed method uses a setup of two acoustic vector sensors (AVS). The intersection of azimuth rays from each AVS should indicate the position of a source. In practice, the result of position estimation using this method is an area rather than a point. This is a result of inaccuracy of the individual sensors, but more importantly, of the influence of a source...
-
Electrochemical sensor for measurement of volatile organic compounds in air
PublicationPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania mrówczanu etylu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako techniki detekcyjne pulsową woltamperometrię różnicową (DPV) oraz woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym była ciecz jonowa (chlorek 1-heksylo,3-metyloimidazolinowy)....
-
A novel sensor for measuring temperature profile during the thermoablation
PublicationAbstract — A novel approach for monitoring a temperature distribution inside a tissue during thermoablation is presented in the paper. A thermal profile is measured using a set of serially connected thermistors each bypassed by a capacitor. This technique allows a two-wire and simultaneous multi- point measurements using a multi-frequency measurement of electrical impedance. It is...
-
The geometry of free-standing titania nanotubes as a critical factor controlling their optical and photoelectrochemical performance
PublicationTitanium dioxide nanotubes are regarded as one of the most important functional materials and due to their unique electronic properties, chemical stability and photocorrosion resistance, they find applications in, for example, highly efficient photocatalysis or perovskite solar cells. Nevertheless, modification of TiO2 nanotubes is required to overcome their main drawback, i.e. large energy bandgap (>3.2 eV) limiting their ability...
-
Use of optical skin phantoms for preclinical evaluation of laser efficiency for skin lesion therapy
PublicationSkin lesions are commonly treated using laser heating. However, the introduction of new devices into clinical practice requires evaluation of their performance. This study presents the application of optical phantoms for assessment of a newly developed 975-nm pulsed diode laser system for dermatological purposes. Such phantoms closely mimic the absorption and scattering of real human skin (although not precisely in relation to...
-
Data from pizoelectric pressure sensor placed inside PWK pump chamber
Open Research DataThe dataset contains raw data acquired from a piezoelectric pressure sensor placed inside PWK pump chamber. Pumping pressure was 10MPa, displacement was set to 100%, oil temperature was 33C. Columns "Czas" stand for a time in seconds and milliseconds, "Napięcie" stands for Voltage in Volts
-
Integrating Optical Spectroscopy and Chemometric Methods
Publication