displaying 1000 best results Help
Search results for: DYNAMIC IMPEDANCE MEASUREMENTS
-
Linear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass heat-treated for 3 hours at 693 K, measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of partially crystallized 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance of 58(2Bi2O3-V2O5)-42SrB4O7 glass heat-treated for 10 hours at 693 K, measured with impedance spectroscopy method at low temperature region
Open Research DataThe linear electrcial properties of partially crystallized 58(2Bi2O3-V2O5)-42SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K measured with impedance spectroscopy method at 273 K
Open Research DataThe linear electrcial properties as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K was measured by impedance spectroscopy method.
-
EXHAUST TEMPERATURE MEASUREMENTS OF THE MARINE TURBOCHARGED DIESEL ENGINES IN OPERATION
PublicationThe article presents the selected metrology issues concerning the exhaust temperature of the turbocharged marine engines during operation. The special concern has been paid on existing disturbances as well as thermodynamical interpretation of the recorded measurement signal. A diagnostic informativeness of the standard exhaust temperature’s measurements has worked out while the engine runs in steady states has been also considered...
-
Linear impedance of 35P2O5-30Fe2O3-35Nb2O5
Open Research DataThe electrical properties of phosphate-iron glasses containing niobium were investigated. Glass samples of the composition of 35P2O5-30Fe2O3-35Nb2O5 (in %mol) were prepared by the conventional melt quenching technique. Appropriate amounts of reagents ((NH4)2HPO4 (≥99.9%, POCH), Fe2O3 (≥99.9%, POCH), Nb2O5 (≥99.9%, PLUKA AG) and TiO2 (≥99.9%, anatase...
-
Measurements of High-Speed Data Transmission Radio Link for Special Applications
PublicationIn the article measurements of high-speed data transmission radio link for special applications were presented. Build measurement stand, measurement scenario and obtained results were briefly described. All conducted research work took place in real maritime environment.
-
Testing HIADAC high impedance analyzer in Trento University laboratory on "unknown" object using 2-wire probe
Open Research DataThe dataset presents impedance spectrum of "black-box" object with interesting phase characteristics. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 Hz – 100 kHz) was selected in order to test the whole measureement...
-
Experimental determination of dynamic properties of cylindrical steel tank model filled with liquid
PublicationIn technical branches, such as chemical or petroleum industries, cylindrical steel tanks are essential structures used for storage of liquid products. Any failure might have disastrous consequences, therefore their safety and reliability is essential. The aim of the present paper is to show the results of the experimental study which has been conducted on a scaled model of a real tank used in Poland. The investigation was carried...
-
High-Precision FIR-Model-Based Dynamic Weighing System
PublicationConveyor belt-type checkweighers are increasingly popular components of modern production lines. They are used to assess the weight of the produced items in motion, i.e., without stopping them on the weighing platform. The main challenge one faces when designing a dynamic weighing system is providing high measurement accuracy, especially at high conveyor belt speeds. The approach proposed in this paper can be characterized as a...
-
Electrochemical cell impedance spectra at Eoc+100mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc+200mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-100mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
Electrochemical cell impedance spectra at Eoc-200mV
Open Research DataThe dataset presents impedance spectrum of electrochemical cell filled with 3% NaCl solution presented in the figure below. This cell was used measured using Atlas-Sollich 0531 impedance analyser with built-in potentiostat. When changing the DC polarisation of the cell the non-linear phenomena could be observed. The impedance spectrum frequency range...
-
A Low-Cost System for Far-Field Non-Anechoic Measurements of Antenna Performance Figures
PublicationPrototype measurements are the key step in the development of antenna structures. Typically, their far-field characteristics are validated in expensive, dedicated facilities such as open range sites, or anechoic chambers. Despite being necessary for obtaining high-precision data (e.g., for device qualification), the use of costly infrastructure might not be fully justified when the main goal of measurements includes demonstration...
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 2
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Linear impedance as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat-treated at 813 K measured with impedance spectroscopy method at high temperature region
Open Research DataThe linear electrcial properties as a function of A.C. voltage of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat treated at 813 K was measured by impedance spectroscopy method.
-
Effect of starch fillers on the dynamic mechanical properties of rubber biocomposite materials
PublicationIn the paper the results of dynamic mechanical study of the biocomposites containing one of two types of (potato or corn) strach used as fillers in different amount were discussed. The composites were obtained from rubbery mixture containing natural rubber (NR) as a main component. Thermomechanical analyses (by DMA) showed that the used quantity of strach fillers only slightly influence on the glass transition temperature of vulcanizates.
-
Nonlinear impedance as a function of A.C. voltage for fully crystallized 35Bi2VO5.5-65SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties as a function of A.C. voltage for fully crystallized 35Bi2VO5.5-65SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance of 40Bi2VO5.5-60SrB4O7 annealed glass at 473 K for 3 h measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of 40Bi2VO5.5-60SrB4O7 glass annealed at 473 K for 3h was measured by impedance spectroscopy method.
-
Nonlinear impedance as a function of A.C. voltage for fully crystallized 45Bi2VO5.5-55SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties as a function of A.C. voltage for fully crystallized 45Bi2VO5.5-55SrB4O7 glass was measured by impedance spectroscopy method.
-
Simulation Results of Dynamic Capacity Reallocation in Hierarchical Cell Structure of UMTS Network
PublicationIn the paper simulation results of dynamic capacity reallocation between different layers of hierarchical cell structure of UMTS network has been described. This approach for load management seems to be useful for improving the resource utilization perfmorance.
-
Radio Channel Measurements in 868 MHz Off-Body Communications in a Ferry Environment
PublicationIn this paper, a characterization of the 868 MHz off-body radio channel in BANs is presented. Measurements were carried out in a ferry environment using a specific set-up. A method for path loss using radio distance measurements (RDMs) was developed. It allows to automate the measurements process and make it independent from the variable speed of a moving person. Based on the observed path loss as a function of distance, the obtained...
-
Reliability of Pulse Measurements in Videoplethysmography
PublicationReliable, remote pulse rate measurement is potentially very important for medical diagnostics and screening. In this paper the Videoplethysmography was analyzed especially to verify the possible use of signals obtained for the YUV color model in order to estimate the pulse rate, to examine what is the best pulse estimation method for short video sequences and finally, to analyze how potential PPG-signals can be distinguished from...
-
Mobility measurements in oxide semiconductors
PublicationPraca zawiera wyniki badań właściwości elektrycznych, optycznych i strukturalnych cienkich warstw ito i sno2. badania wykazały, że cienkie warstwy tlenków metali wykazują rezystywność charakterystyczną dla półprzewodników. poziom transmisji światła w zakresie widzialnym pozwala zaliczyć badane warstwy do materiałów przezroczystych. badane cienkie warstwy wykonano metodą rozpylania magnetronowego.
-
Measurements of Subnanometer Molecular Layers
PublicationSelected methods of formation and detection of nanometer and subnanometer molecular layers were shown. Additionally, a new method of detection and measurement with subnanometer resolution of layers adsorbed or bonded to the gate dielectric of the ion selective field effect transistor (ISFET) was presented.
-
Measurements of relative frequency instability
PublicationFrequency constancy can be determined by the change in time for the subsequent periods. The article shows that classical the method of digital period measurement is not suitable for the measurement process. Therefore, a method using an integrating circuit is being proposed. Errors in the measurement of the given method have been analyzed.
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 2 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Nonlinear impedance of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat-treated at 613 K measured with impedance spectroscopy method at high temperature region
Open Research DataNonlinear electrcial properties of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat treated at 613 K was measured by impedance spectroscopy method.
-
Modified dynamic time warping method applied to handwritten signature authenticity verification
PublicationA signature verification system based on static features and time-domain functions of signals obtained using a tablet has been presented in the paper. The signature verification method, based mainly on dynamic time warping coupled with some signature image features, has been described. The FRR measures reflecting the method’s efficiency have been evaluated for verification attempts performed directly after obtaining model signatures...
-
DYNAMIC POSITIONING CAPABILITY ASSESSMENT BASED ON OPTIMAL THRUST ALLOCATION
PublicationThe article presents an efficient method of optimal thrust allocation over the actuators in a dynamically positioned ship, according to the DNV-ST-0111 standard, Level 1. The optimisation task is approximated to a convex problem with linear constraints and mathematically formulated as quadratic programming. The case study is being used to illustrate the use of the proposed approach in assessing the DP capability of a rescue ship....
-
Correction of determined coordinates of railway tracks in mobile satellite measurements
PublicationThis article examines one of the basic issues related to the technique of mobile satellite measurements in railway tracks. This problem concerns the correction of the determined coordinates of the track centerline. The need to perform this operation results from the GNSS receivers positioning at a certain height above the level of the existing track axis, leading to longitudinal and lateral shifts of antennas. The key problem here...
-
Generating optimal paths in dynamic environments using RiverFormation Dynamics algorithm
PublicationThe paper presents a comparison of four optimisation algorithms implemented for the purpose of finding the shortest path in static and dynamic environments with obstacles. Two classical graph algorithms –the Dijkstra complete algorithm and A* heuristic algorithm – were compared with metaheuristic River Formation Dynamics swarm algorithm and its newly introduced modified version. Moreover, another swarm algorithm has been compared...
-
Static and dynamic modelling blow- out type trauma of orbital wall
PublicationAuthors of the paper present initial results of finite element analysis of a blow-out type trauma of orbital wall. The research is liked with laboratory tests for the Young’s modulus of bones evaluation. In the finite element analysis the neighbourhood of orbital wall is modelled by triangle thin shell finite elements. In the paper results of nonlinear static and transient dynamic analysis (including damping) are compared. The...
-
Raman Spectra Measurements for Chemical Identifications - Aspect of Uncertainty Sources and Reduction of Their Effects
PublicationRaman spectrometers enable fast and non-contact identification of examined chemicals. These devices measure Raman spectra and compare with the spectra database to identify unknown and often illicit chemicals (e.g. drugs, explosives) usually without any sample preparation. Raman spectra measurements are a challenge due to noise and interferences present outside the laboratories (field applications). The design of a portable Raman...
-
Trust-Based Model for the Assessment of the Uncertainty of Measurements in Hybrid IoT Networks
PublicationThe aim of this paper is to introduce a NUT model (NUT: network-uncertainty-trust) that aids the decrease of the uncertainty of measurements in autonomous hybrid Internet of Things sensor networks. The problem of uncertainty in such networks is a consequence of various operating conditions and varied quality of measurement nodes, making statistical approach less successful. This paper presents a model for decreasing the uncertainty...
-
Analysis of data fusion algorithms for the vessel with the dynamic positioning system
PublicationThe dynamic positioning (DP) system on the vessel is operated to control the position and heading of the vessel with the use of propellers and thrusters installed on the board. On DP vessels redundant measurement systems of position, heading and the magnitude and direction of environmental forces are required for safety at sea. In this case, a fusion of data is needed from individual measurement devices. The article proposes a...
-
Testing HIADAC high impedance analyzer in Trento University laboratory on Baunier's RC model using 3 wire probe
Open Research DataThe dataset presents impedance spectrum of Baunier's RC model. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The impedance spectrum frequency range (1 mHz – 100 kHz) was selected in order to test the whole measureement range of the analyzer. In...
-
Channel Impulse Response Measurements at mmWave Band in Office and Conference Rooms
PublicationIn this paper, the measurements of the channel impulse response at mmWave band in office and conference rooms are described. The central frequency is 27 GHz with a bandwidth of 400 MHz. The description of the used measurement stand and considered environments are presented. The initial analysis of the power delay profile, mean delay, and RMS delay spread allows preliminary conclusions to be drawn that there is a significant impact...
-
Certified Reference Material - as a necessary tool for the quality control and quality assurance of measurements
PublicationReference materials are necessary to control and ensure the quality of the measurements. The demand for analytical information on the composition of different material objects makes it necessary to produce an even wider range of materials.
-
Nonlinear impedance of Bi2VO5.5 ceramic prepared by traditional melt quenching technique was measured with impedance spectroscopy method at low temperature region
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
Export diversification and economic development: a dynamic spatial data analysis
PublicationThis paper contributes to the empirical literature on the relationship between ‘export variety’ (export diversification) and economic development by relaxing the assumption of cross-country independence and allowing for spatial diffusion of shocks in observed and unobserved factors. Export variety is measured for a balanced panel of 114 countries (1992-2012) using very detailed information on their exports (HS 6-digit product...
-
Dynamic characteristics of the proton exchange membrane fuel cell module
PublicationThe paper describes a fuel cell based system and its performance. The system is based on two fuel cell units, DC/DC converter, DC/AC inverter, microprocessor control unit, load unit, bottled hydrogen supply system and a set of measurement instruments. In the study presented in the paper a dynamic response of the proton exchange membrane (PEM) fuel cell system to unit step change load as well as to periodical load changing cycles...
-
DYNAMIC RESPONSE OF FORUM GDANSK STRUCTURE DUE TO RAIL TRAFFIC
PublicationThe paper presents the study of the impact of vibration induced by the movement of the railway rolling stock on the Forum Gdańsk structure. This object is currently under construction and is located over the railway tracks in the vicinity of the Gdańsk Główny and Gdańsk Śródmieście railway stations. The analysis covers the influence of vibrations on the structure itself and on the people within. The in situ measurements on existing...
-
Nonlinear high temperature impedance of 35P2O5-30Fe2O3-35Nb2O5 glass
Open Research DataThe nonlinear high temperature impedance of iron- phosphate glasses doped with niobium oxide was measured. Glass samples of the composition of 35P2O5-30Fe2O3-35Nb2O5 (in %mol) were prepared by the conventional melt quenching technique. Appropriate amounts of reagents ((NH4)2HPO4 (≥99.9%, POCH), Fe2O3 (≥99.9%, POCH) and Nb2O5 (≥99.9%, PLUKA AG) were...
-
Neural modelling of dynamic systems with time delays based on an adjusted NEAT algorithm
PublicationA problem related to the development of an algorithm designed to find an architecture of artificial neural network used for black-box modelling of dynamic systems with time delays has been addressed in this paper. The proposed algorithm is based on a well-known NeuroEvolution of Augmenting Topologies (NEAT) algorithm. The NEAT algorithm has been adjusted by allowing additional connections within an artificial neural network and...
-
Mesoscopic impedance analysis of solid materials’ surface
Publication -
Instantaneous electrochemical impedance spectroscopy of electrode reactions
Publication -
The time dependence of pit creation impedance spectra
Publication -
Continuous‐Frequency Method of Measurement of Electrode Impedance
Publication -
Change of myocardial impedance during experimental ischemia.
PublicationW pracy omówiono możliwość monitorowania procesu niedotlenienia za pomocą pomiarów immitancyjnych. Przedstawiono skonstruowane stanowisko pomiarowe ze szczególnym uwypukleniem właściwości sondy pomiarowej. Przedstawiono wyniki eksperymentalnego niedotlenienia u świń wywołanego zamknięciem LAD.