Search results for: calibration
-
Discrimination of Apple Liqueurs (Nalewka) Using a Voltammetric Electronic Tongue, UV-Vis and Raman Spectroscopy
PublicationThe capability of a phthalocyanine-based voltammetric electronic tongue to analyze strong alcoholic beverages has been evaluated and compared with the performance of spectroscopic techniques coupled to chemometrics. Nalewka Polish liqueurs prepared from five apple varieties have been used as a model of strong liqueurs. Principal Component Analysis has demonstrated that the best discrimination between liqueurs prepared from different...
-
Change of exhaust gases concentration for reference SOFC and SOFC with LSCNT layer fueled by biogas mixture at 750 C
Open Research DataThe dataset changes of exhaust gases concentrations (CH4,CO,CO2,H2) over working time for SOFC with La0.27Sr0.54Ce0.09Ni0.1Ti0.9O3-s layer as well as reference SOFEC (unmodified). Concentrations were calculated based on the FTIR measurements and calibration curves presented in different dataset. Longterm measurements of SOFC were performed using in-house...
-
Measurement method for capacitive sensors for microcontrollers based on a phase shifter
PublicationA complete measurement method dedicated to capacitive sensors has been developed. It includes the development of hardware (an analogue interface circuit for microcontrollers with built-in times/counters and analogue comparators) and software (a measurement procedure and a systematic error calibration (correction) algorithm which is based on a calibration dictionary). The interface circuit consists of a low-pass filter and a phase...
-
Co-simulation strategy of transient CFD and heat transfer in building thermal envelope based on calibrated heat transfer coefficients
PublicationThe paper presents a strategy to develop a fully transient numerical model of a heat transfer in building, using a transient CFD model of indoor air and a thermal envelope model, running in a co-simulation. The strategy relies on the utilization of RANS with a high-Re turbulence model and a wall function, which enables to use a coarse computational mesh limiting the computational time. Since wall functions give invalid heat transfer...
-
Accounting for the distributions of input quantities in the procedure for the measurement uncertainty evaluation when calibrating the goniometer
PublicationThe discords concerning the measurement uncertainty evaluation in the Guide to the Expressing of Uncertainty in Measurement (GUM) and its Supplement 1 are considered. To overcome these discords, the authors of the paper propose to use the kurtosis method and the law of the propagation of the expanded uncertainty. Using the example of the goniometer calibration, the features of accounting for the distribution laws of input quantities...
-
Radioisotope measurement of selected parameters of liquid-gas flow using single detector system
PublicationTo determine the parameters of two-phase flows using radioisotopes, usually two detectors are used. Knowing the distance between them, the velocity of the dispersed phase is calculated based on time delay estimation. Such a measurement system requires the use of two gamma-ray sealed sources. But in some situations it is also possible to determine velocity of dispersed phase using only one scintillation probe and one gamma-ray source....
-
Model-based identification of the dominant N2O emission pathway in a full-scale activated sludge system
PublicationActivated sludge models (ASMs), extended with an N2O emission module, are powerful tools to describe the operation of full-scale wastewater treatment plants (WWTPs). Specifically, such models can investigate the most contributive N2O production pathways and guide towards N2O and carbon footprint (CF) mitigation measures. A common practice is to develop and validate models using data from a single WWTP. In this study, a successfully...
-
Urządzenie do wytwarzania gazowych mieszanin wzorcowych z wykorzystaniem procesu barbotażu oraz permeacji
PublicationReference gas mixtures are classified to reference materials and are mainly used for quality monitoring and identification of impurities in atmospheric air. They can be also used for calibration of measuring devices. Nowadays, there is a need to develop a new techniques for the preparation of reference gas mixtures [1, 2]. In this paper the design and the operating principles of instrument based on the use of barbotage and permeation...
-
PHYSICAL MODELLING OF GEOTECHNICAL STRUCTURES IN PORTS AND OFFSHORE
PublicationThe physical modelling of subsoil behaviour and soil-structure interaction is essential for the proper design of offshore structures and port infrastructure. A brief introduction to such modelling of geoengineering problems is presented and some methods and experimental devices are described. The relationships between modelling scales are given. Some examples of penetration testing results in centrifuge and calibration chamber...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #24 - #25.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #24 (upper, rotating), #25 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #28 - #29.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #28 (upper, rotating), #29 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #30 - #31.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #30 (upper, rotating), #31 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #20 - #21.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #20 (upper, rotating), #21 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #22 - #23.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #22 (upper, rotating), #23 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #28 - #29.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #28 (upper, rotating), #29 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Specimen running-in. Prep. to sliding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specimen set #26 - #27.
Open Research DataSpecimen running-in procedure. Preparation to sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. Specimen set #26 (upper, rotating), #27 (lower, non-rotating)CZ_PRZYS.MAT - accelerometerMOM_TAR.MAT...
-
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 4-8h.
Open Research DataWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer.Running time: 4-8h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21, #22-#23, #24-#25, #26-#27,...
-
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 0-4h.
Open Research DataWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer.Running time: 0 - 4h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21, #22-#23, #24-#25, #26-#27,...
-
Reverberation chamber in emc tests of naval systems
PublicationPaper covers the techniques of emission and immunity testing to the electromagnetic field in reverberation chamber. The procedure of he chamber calibration and field homogeneity assessment were covered. The naval forces' product as selected as an example for discussing the testing procedure in the chamber. The paper's summary gives the assortment of methodology in radiation emission testing and immunity to the electromagnetic field...
-
Synchro-photogrammetry in the measurement of objects in motion - the case study
PublicationSynchronous photographs and digital photogrammetry methods in a measurement of objects in motion - the experiment. In the following paper, a case study example of a photogrammetric method based on synchronous digital photographs has been presented. This measurement method is an effective solution for tracking of moving objects, dynamic studies and dimensioning of geometry movements. Nowadays, the use of synchronous photography...
-
Multi-Channel Virtual Instrument for Measuring Temperature—A Case Study
PublicationThe article presents the hardware and software configuration of the developed multi-channel temperature measurement system as well as calibration procedures and measurement results verifying the properties of measurement channels. The system has been developed and dedicated primarily for measuring the temperature distribution in a laboratory model simulating underground power lines. With the adopted configuration of the analog...
-
Estimation of object size in the calibrated camera image = Estymacja rozmiaru obiektów w obrazach ze skalibrowanej kamery
PublicationIn the paper, a method of estimation of the physical sizes of the objects tracked by the camera is presented. First, the camera is calibrated, then the proposed algorithm is used to estimate the real width and height of the tracked moving objects. The results of size estimation are then used for classification of the moving objects. Two methods of camera calibration are compared, test results are presented and discussed. The proposed...
-
Wear in siding friction tests. Ring-on-ring contact. Sintered alumina ceramics (98%). Paraffin oil lubrication. Specim. sets #20-#21, #22-#23, #24-#25, #26-#27, #28-#29,#30 - #31. Run time: 0-4h. High frequency burst recording.
Open Research DataWear in sliding friction tests in ring-on-ring contact. Sintered alumina ceramics (98%) in self-mated contact. Lubrication: paraffin oil. Sliding velocity: 0.2 m/s. Mean contact stress: 10 MPa. Test rig: PT-3 Tribometer. High frequency burst recording.Running time: 0 - 4h.Specimen sets:Specim. sets (# [upper, rotating] - #[lower, non-rotating]):#20-#21,...
-
Elemental composition of deposited sediments - Warszawska/Havla tram-route junction (2024 May)
Open Research DataThis data set contains the elemental composition results of deposited sediments collected at the tram-route junction in Gdańsk. Samples collected after fifteen months of operation of tram line.
-
Prototype of electrochemical sensor for measurements of volatile organic compounds in gases
PublicationThe paper presents a laboratory prototype of an electrochemical sensor for measurements of volatile organic compounds (VOCs) in gases, utilizing ionic liquids and commercial screen printed electrodes by DropSens. The following ionic liquids have been tested as the electrolyte and redox reaction environment: 1-butyl, 3-methylimidazolium dicyanoamide ([BMIM][N(CN)2]), 1-octyl, 3-methylimidazolium tetrafluoroborate ([OMIM][BF4]),...
-
Measuring Tilt with an IMU Using the Taylor Algorithm
PublicationThis article addresses the important problem of tilt measurement and stabilization. This is particularly important in the case of drone stabilization and navigation in underwater environments, multibeam sonar mapping, aerial photogrammetry in densely urbanized areas, etc. The tilt measurement process involves the fusion of information from at least two different sensors. Inertial sensors (IMUs) are unique in this context because...
-
Sulfur compounds: Gas chromatography
PublicationSulfur compounds, due to their properties, are responsible for the damage of our environment. For this reason sulfur containing compounds are of constant concern in many fields. Gas chromatography (GC), due to combination of separation capability and sensitive detection is a prime technique for the analysis of thes compounds in various matrices. The chapter rewies general problems of the determination of these compounds by GC and...
-
Transfer learning in imagined speech EEG-based BCIs
PublicationThe Brain–Computer Interfaces (BCI) based on electroencephalograms (EEG) are systems which aim is to provide a communication channel to any person with a computer, initially it was proposed to aid people with disabilities, but actually wider applications have been proposed. These devices allow to send messages or to control devices using the brain signals. There are different neuro-paradigms which evoke brain signals of interest...
-
Eye tracking within near-to-eye display
PublicationIn this paper we investigate the effectiveness of the gaze interaction within near-to-eye display. The practical aspect of the paper is about combining an eye tracker with smart glasses. Presented research is related with the eGlasses project, which is focused on the development of an open platform in the form of multisensory electronic glasses and related interaction methods. One of the implemented interaction methods is the one...
-
Numerical simulation of asphalt mixtures fracture using continuum models
PublicationThe paper considers numerical models of fracture processes of semi-circular asphalt mixture specimens subjected to three-point bending. Parameter calibration of the asphalt mixture constitutive models requires advanced, complex experimental test procedures. The highly non-homogeneous material is numerically modelled by a quasicontinuum model. The computational parameters are averaged data of the components, i.e. asphalt, aggregate...
-
Adaptive Positioning Systems Based on Multiple Wireless Interfaces for Industrial IoT in Harsh Manufacturing Environments
PublicationAs the industrial sector is becoming ever more flexible in order to improve productivity, legacy interfaces for industrial applications must evolve to enhance efficiency and must adapt to achieve higher elasticity and reliability in harsh manufacturing environments. The localization of machines, sensors and workers inside the industrial premises is one of such interfaces used by many applications. Current localization-based systems...
-
Analysis of magnetic field of Helmholtz's coils
PublicationThe 3-axis fluxgate magnetometer requires conducting a precise calibration in the magnetic field whose value is determined and which is characterized by the high uniformity of the distribution of the field, especially along the axis of the sensors. The generation of the magnetostatic field characterized by the high uniformity, can be achieved by using the Helmholtz's coils. The requirements of the uniformity of distribution of...
-
Techniques of acquiring additional features of the responses of individual gas sensors
PublicationGas sensors usually exhibit lack of selectivity, require fre quent calibration, exhibit drift of the response and a lot of factors, such as humidity or ambient temperature, influen ce their performance. Different approaches can be used to overcome this shortcomings. Building arrays of different sensors and usage of pattern recognition methods to analyze responses of elements...
-
3D Acoustic Field Intensity Probe Design and Measurements
PublicationThe aim of this paper is two-fold. First, some basic notions on acoustic field intensity and its measurement are shortly recalled. Then, the equipment and the measurement procedure used in the sound intensity in the performed research study are described. The second goal is to present details of the design of the engineered 3D intensity probe, as well as the algorithms developed and applied for that purpose. Results of the intensity...
-
Time window based features extraction from temperature modulated gas sensors for prediction of ammonia concentration
PublicationElectronic gas recognition systems, in literature commonly referred as electronic noses, enable the recognition of a type and a concentration of various volatile compounds. Typical electronic gas-analyzing device consists of four main elements, namely, gas delivery subsystem, an array of gas sensors, data acquisition and power supply circuits and data analysis software. The commercially available metal-oxide TGS sensors are widely...
-
Atmospheric opacity estimation based on IWV derived from GNSS observations for VLBI applications
PublicationThermal emission of atmospheric water vapor has a great influence on the calibration of radio astronomical observations at millimeter wavelengths. The phenomenon of an atmospheric water vapor emits noise signal and attenuates astronomical emission. At 22 GHz, integrated water vapor (IWV) obtained from global navigation satellite systems (GNSS) is strictly related to atmospheric opacity (τ0), which is a crucial parameter for data...
-
Measurement of Seafloor Acoustic Backscatter Angular Dependence at 150 kHz Using a Multibeam Echosounder
PublicationAcoustic seafloor measurements with multibeam echosounders (MBESs) are currently often used for submarine habitat mapping, but the MBESs are usually not acoustically calibrated for backscattering strength (BBS) and cannot be used to infer absolute seafloor angular dependence. We present a study outlining the calibration and showing absolute backscattering strength values measured at a frequency of 150 kHz at around 10–20 m water...
-
Calculations of material factors for a set of 20 thermistors
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Analysis of magnetic field of Hemholtz's coils and ferromagnetic objects
PublicationThe 3-axis fluxgate magnetometer requires conducting a precise calibration in the magnetic field whose value is determined and which is characterized by the high uniformity of the distribution of the field, especially along the axis of the sensors. The generation of the magnetostatic field characterized by the high uniformity, can be achieved by using the Helmholtz's coils. The requirements of the uniformity of distribution of...
-
Peculiarities of measurement uncertainty evaluation at calibrating a ring gauge
PublicationExample S13 from EA-4/02 M:2013 “Calibration of a ring gauge with a nominal diameter of 90 mm” is analyzed. The report uses the kurtosis method and the law of propagation of expanded uncertainty developed by the authors to the expanded uncertainty evaluation. It is shown that the introduction of a coaxiality correction for the ring gauge and the measuring axis of the comparator leads to the need to estimate its standard measurement...
-
Crack Mouth Opening Displacement for EH36 Shipbuilding Steel Measurements
PublicationThe dataset titled EH36 steel for shipbuilding (plate thicnkness 50mm) - CMOD - force record, a0/W = 0.6 contains CMOD (Crack Mouth Opening Displacement) - Force record which is the base for evaluation of fracture toughness of structural steel. Bend specimens witch Bx2B section (B= 50mm), and relative initial crack length a0 / W = 0.60 were used. The test was carried out at ambient temperature in accordance to ISO 12135 standard....
-
Koncepcja systemu wspomagania decyzji nawigatora statku opartego na ewolucyjnym planowaniu manewrów antykolizyjnych
PublicationArtykuł przedstawia koncepcję systemu wspomagania decyzji nawigatora statku opartego na wątkach badań prowadzonych wcześniej przez autora. System będzie rozszerzał funkcjonalność systemów dotychczasowych o możliwość szczegółowego planowania bezpiecznej trajektorii statku na wodach zamkniętych, z dużą liczbą statków obcych i ograniczeniami toru wodnego. Artykuł zawiera dyskusję możliwych podejść do planowania manewrów, optymalizacji...
-
Crack Mouth Opening Displacement for EH36 Shipbuilding Steel Measurements Dataset
PublicationThe dataset titled EH36 steel for shipbuilding (plate thickness 50 mm) – CMOD – force record, a0/W=0.6 contains a CMOD (Crack Mouth Opening Displacement) – Force record which is the base for evaluation of the fracture toughness of structural steel. Bend specimens with a Bx2B section (B = 50 mm), and relative initial crack length a0/W=0.60 were used. The test was carried out at ambient temperature in accordance with the ISO 12135...
-
Determination of trace levels of eleven bisphenol A analogues in human blood serum by high performance liquid chromatography–tandem mass spectrometry
PublicationChemicals showing structural or functional similarity to bisphenol A (BPA), commonly called BPA analogues, have recently drawn scientific attention due to their common industrial and commercial application as a substitute for BPA. In the European Union, the use of BPA has been severely restricted by law due to its endocrine disrupting properties. Unfortunately, it seems that all BPA analogues show comparable biological activity,...
-
FFT analysis of temperature modulated semiconductor gas sensor response for the prediction of ammonia concentration under humidity interference
PublicationThe increasing environmental contamination forces the need to design reliable devices for detecting of the volatile compounds present in the air. For this purpose semiconductor gas sensors, which have been widely used for years, are often utilized. Although they have many advantages such as low price and quite long life time, they still lack of long term stability and selectivity. Namely, environmental conditions have significant...
-
Zastosowanie metod eksploracji danych do analizy odpowiedzi czujników gazu
PublicationZagadnienia poruszane w niniejszej rozprawie dotyczą zastosowania metod eksploracji danych do analizy odpowiedzi czujników gazu, umożliwiających poprawną identyfikację składu mieszaniny gazowej w elektronicznych systemach rozpoznawania gazu. Elektroniczne systemy rozpoznawania gazu to urządzenia wykorzystujące czujniki gazu oraz odpowiednio dobrane metody analizy danych pomiarowych, zdolne do określenia składu mierzonej mieszaniny...
-
Deep compaction control of sandy soils
PublicationVibroflotation, vibratory compaction, micro-blasting or heavy tamping are typical improvement methods for the cohesionless deposits of high thickness. The complex mechanism of deep soil compaction is related to void ratio decrease with grain rearrangements, lateral stress increase, prestressing effect of certain number of load cycles, water pressure dissipation, aging and other effects. Calibration chamber based interpretation...
-
A material model of asphalt mixtures based on Monte Carlo simulations
PublicationThe paper aims to numerically reflect mineral-asphalt mixture structure by a standard FEM software. Laboratory test results are presented due to bending tests of circular notched elements. The result scatter is relatively high. An attempt was made to form a random aggregate distribution in order to obtain various results corresponding to laboratory tests. The material structure calibration, its homogenization and finite element...
-
Elemental composition of deposited sediments at the tram-route junction
Open Research DataThis data set contains the elemental composition results of deposited sediments collected at the tram-route junction in Gdańsk. Sample collection began in July 2022, when the tram lines were completed and before the rails were scrubbed (27/07/2022). The second sample round was carried out following rail scrubbing in October 2022 (7/10/2022). Since February...
-
Viewpoint independent shape-based object classification for video surveillance
PublicationA method for shape based object classification is presented.Unlike object dimension based methods it does not require any system calibration techniques. A number of 3D object models are utilized as a source of training dataset for a specified camera orientation. Usage of the 3D models allows to perform the dataset creation process semiautomatically. The background subtraction method is used for the purpose of detecting moving objects...