Filters
total: 499
Search results for: DETEKTORY CHROMATOGRAFICZNE
-
Analytical procedures for the determination of surfactants in environmental samples
PublicationBecause of their specific physical and chemical properties (amphiphilicity, solubility in polar and nonpolar liquids, ability to form micelles, adsorption at phase boundaries, low toxicity) surfactants (surface-active compounds) are widely applied in industry and in the household. As their applications are on a very large scale, it has become necessary to acquire a more detailed understanding of their environmental fate.In the...
-
Balance of pesticides mass in gas, liquid and solid phase after their chemical degradation.
PublicationOpisano metodę usuwania pestycydów z wody przy zastosowaniu fotodegradacji (UV) i katalizatora (TiO2). Efektywność procesu usuwania pestycydów była kontrolowana przy zastosowaniu chromatografu gazowego z detektorem wychwytu elektronów. Oznaczano zawartość pestycydów w wodzie, a także zaadsorbowanych na powierzchni stałej, oraz w fazie gazowej. Największa zawartość pestycydów znajdowała się na fazie stałej, następnie w cieczy i...
-
Badanie struktury i właściwości elektrycznych redukowanych szkieł bizmutowo-krzemianowych, bizmutowo-germanianowych i ołowiowo-germanianowych modyfikowanych potasem
PublicationPraca zawiera wyniki badań struktury i właściwości elektrycznych redukowanych szkieł bizmutowo-krzemianowych, bizmutowo-germanianowych i ołowiowo-germanianowych modyfikowanych potasem. Badania przeprowadzono w kontekście przydatności tych szkieł w technice. Redukowane w wodorze szkła ołowiowo-germnanianowe wykazują ciekawe właściwości związane z nadprzewodnictwem. Z badań szkieł bizmutowo-krzemianowych wynika, że te szkła po odpowiedniej...
-
X-ray diffractometry results of the SrTi0.50Fe0.50O3-d powder
Open Research DataThis dataset contains results of X-ray diffractometry mesurement (XRD) of the SrTi0.50Fe0.50O3-d (STF50) powder after ball milling. The phase composition of the investigated STF50 powder was analyzed by XRD at room temperature. The X-ray diffractometry (XRD) technique was used to determine the phase composition of the fabricated powder. Measurements...
-
X-ray diffractometry results of the SrTi0.35Fe0.65O3-d powder
Open Research DataThis dataset contains results of X-ray diffractometry mesurement (XRD) of the SrTi0.35Fe0.65O3-d (STF35) powder after ball milling. The phase composition of the investigated STF35 powder was analyzed by XRD at room temperature. The X-ray diffractometry (XRD) technique was used to determine the phase composition of the fabricated powder. Measurements...
-
X-ray diffractometry results of the SrTi0.30Fe0.70O3-d powder
Open Research DataThis dataset contains results of X-ray diffractometry mesurement (XRD) of the SrTi0.30Fe0.70O3-d (STF70) powder after ball milling. The phase composition of the investigated STF70 powder was analyzed by XRD at room temperature. The X-ray diffractometry (XRD) technique was used to determine the phase composition of the fabricated powder. Measurements...
-
Dependence of biological sensing on temperature based on investigation of SARS-CoV-2
Open Research DataPresented dataset is the result of an investigation of the attachment of SARS-CoV-2 specific IgG in the temepratures relevant in biology. The samples were measured during a period of 15 minutes, at 5°C, 25°C and 55°C. The measurements were performed using the microspher-based fiber-optic sensor, as an interferometer. The broadband optical light source...
-
Thin layer headspace gas chromatography for biological monitoring of persons exposed to volatile organohalogen compounds from water
PublicationCelem pracy było zbadanie możliwości wykorzystania analizy fazy nadpowierzchniowej nad cienką warstwą cieczy z samoczynną generacją ciekłego sorbentu (TLHS)do izolacji i wzbogacania THM w próbkach moczu i krwi ludzkiej. Umożliwiło to następnie wykorzystanie prostej techniki bezpośredniego nastrzyku próbki do kolumny chromatografu gazowego, wyposażonego w detektor wychwytu elektronów (DAI-GC-ECD).Przy pomocy tak opracowanej metody...
-
Confocal microscopy analysis of DNA DSB in telomerase negative cells after exposure to TXT2 and TXT4
Open Research DataThe data sets contain confocal microscopic images showing the γ-H2AX with TRF2 after treatment of NHBE and U2OS cell lines with TXT2 and TXT4 in equitoxic concentrations. Images were acquired with an LSM 800 inverted laser scanning confocal microscope (Carl Zeiss; Dresden, Germany) equipped with an Airyscan detector using a ×63 1.4 NA Plan Apochromat...
-
Zastosowanie chromatografii gazowej w analityce technicznej do charakterystyki ksylenu technicznego na potrzeby rejestracji w systemie REACH
PublicationW pracy przedstawiono metodykę badań ksylenu technicznego w celu jego charakterystyki zgodnie z wymaganiami rejestracyjnych systemu REACH. W badaniach zastosowano technikę chromatografii gazowej z detektorem płomieniowo-jonizacyjnym (GC-FID) oraz w sprzężeniu ze spektrometrią mas (GC-MS) Chromatografia gazowa umożliwia wykonanie dwóch fundamentalnych oznaczeń tego typu mieszaniny – tzn. zbadania czystości mieszaniny oraz identyfikacji...
-
ANALIZA SKUTECZNOŚCI DETEKCJI SYGNAŁÓW GMSK W KANALE Z PROPAGACJĄ WIELODROGOWĄ PRZY UŻYCIU METOD GŁĘBOKIEGO UCZENIA
PublicationOdbiór sygnałów radiowych w środowisku wewnątrzbudynkowym jest istotnym problemem współczesnej radiokomunikacji. W celu zwiększenia skuteczności istniejących metod odbioru radiowego coraz częściej wykorzystuje się narzędzia z obszaru uczenia maszynowego. Niniejszy artykuł prezentuje analizę skuteczności głębokiej sieci neuronowej w odbiorze sygnałów GMSK w kanale z zanikami i propagacją wielodrogową. Prezentowane wyniki porównane...
-
The structure of vanadate glass-ceramics containing BaTiO3.
Open Research DataThe structure of vanadate glass-ceramics doped with BaTiO3 was measured by SEM technique. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on...
-
X-ray diffractometry results of the Sr0.90Ti0.30Fe0.70O3-d material before and after H2-TPR measurement
Open Research DataThis dataset contains results of X-ray diffractometry mesurement (XRD) of the Sr0.90Ti0.30Fe0.70O3-d material. The phase composition of the investigated powders was analyzed by XRD at room temperature. The X-ray diffractometry (XRD) technique was used to determine the phase composition of the fabricated powder and powder after H2-TPR (temperature programmed...
-
X-ray diffractometry results of the Sr0.95Ti0.30Fe0.70O3-d material before and after H2-TPR measurement
Open Research DataThis dataset contains results of X-ray diffractometry mesurement (XRD) of the Sr0.95Ti0.30Fe0.70O3-d material. The phase composition of the investigated powders was analyzed by XRD at room temperature. The X-ray diffractometry (XRD) technique was used to determine the phase composition of the fabricated powder and powder after H2-TPR (temperature programmed...
-
SPTNO ceramics measured by XPS method
Open Research DataSPTNO (Sr-Pr-Ti-Ni-O) ceramic were manufactured by solid state reaction, from oxides compounds. Synthesis conducted in air atmosphere at temperature in a range of 800-900 deg. Chemical composition of prepared materials were measured by XPS (X-Ray photoemision spectroscopy) method. UHV OmicronNanotechnology system with 128 channel Argus hemispherical...
-
Smart city and fire detection using thermal imaging
PublicationIn this paper, we summarize the results obtained from fire experiments. The aim of the work was to develop new methods of fire detection using IR thermal imaging cameras and dedicated image processing. We conducted 4 experiments in different configurations and with the use of different objects. The conducted experiments have shown the great usefulness of infrared cameras for detecting the seeds of a fire. Even cheap low-resolution...
-
Polycyclic aromatic hydrocarbons in smoked fish - a critical review
PublicationDym wędzarniczy zawiera wśród setek składników co najmniej 100 wielopierścieniowych węglowodorów aromatycznych (WWA). Benzo{a}piren (BaP) jest uważany za wskaźnikowy, rakotwórczy WWA w wędzonych rybach. Współczesne procedury analityczne obejmujące ekstrakcję węglowodorów z matrycy, oczyszczenie, rozdzielenie metodą GC lub HPLC przy użyciu, odpowiednio, detektora MS albo FLD, umożliwiają oznaczenie indywidualnych WWA w wędzonych...
-
Measurements of passive components using of an IEEE 1149.4 mixed-signal test bus
PublicationW pracy przedstawiono wyniki badań nad wykorzystaniem magistrali testującej mieszanej sygnałowo IEEE 1149.4 do pomiarów elementów pasywnych zamontowanych na pakietach elektronicznych. Do badań użyto wyposażonych w magistralę układów scalonych typu STA400. Zaprezentowano metody pomiaru rezystancji pojedynczych elementów z wykorzystaniem źródła prądowego oraz źródła VH znajdującego się w analogowych modułach ABM układu STA400. Pokazano...
-
XRD for molybdenum sulfide modified with nickel or platinum nanoparticles
Open Research DataThe presented data showcases the results of XRD analysis conducted on molybdenum sulfide modified with nickel or platinum nanoparticles . The MoS2 was prepared on the TiO2 nanotube substrates via a facile hydrothermal method, followed by the deposition by magnetron sputtering of Ni or Pt nanoparticles on the MoS2 surface. Structural characterization...
-
A non-uniform real-time speech time-scale stretching method
PublicationAn algorithm for non-uniform real-time speech stretching is presented. It provides a combination of typical SOLA algorithm (Synchronous Overlap and Add ) with the vowels, consonants and silence detectors. Based on the information about the content and the estimated value of the rate of speech (ROS), the algorithm adapts the scaling factor value. The ability of real-time speech stretching and the resultant quality of voice were...
-
ANALIZA EFEKTYWNOŚCI METOD GŁĘBOKIEGO UCZENIA W ODBIORZE SYGNAŁÓW GMSK
PublicationSztuczna inteligencja odnajduje coraz szersze zastosowanie we współczesnej radiokomunikacji, choć głównie w ujęciu badawczym. Niniejszy artykuł przedstawia przegląd i ewaluację metod z obszaru głębokiego uczenia umożliwiających detekcję sygnałów z modulacją GMSK (ang. Gaussian Minimum Shift Keying) w kanale AWGN. Badane modele porównane zostały z optymalnym detektorem pracującym zgodnie z regułą największej wiarygodności MLSE (ang....
-
New aspects in assessment of changes in width of subarachnoid space with near-infrared transillumination/backscattering sounding, part 2: clinical verification in the patient
PublicationW pracy przedstawiono porównanie wyników symulacji propagacji promieniowania z zakresu bliskiej podczerwieni z danymi uzyskanymi na drodze pomiarów wykonanych w warunkach klinicznych. Różnice między nimi nie przekraczały 4 dB, co potwierdziło słuszność przyjętych założeń w procesie symulacji. W pomiarach wykorzystano unikatowy zetstaw nadajników i odbiorników promieniowania podczerwonego, pozwalającego prowadzenie pomiarów transmisji...
-
Analysis of induction of DNA DSBs on telomeres in A549 cells
Open Research DataData consist of an analysis of DNA DSBs on telomeres. A549 were treated with compounds (TXT4, MTX, DMSO) at IC90 concentration for the indicated time. Images were acquired with an LSM 800 inverted laser scanning confocal microscope (Carl Zeiss; Dresden, Germany) equipped with an Airyscan detector using a ×63 1.4 NA Plan Apochromat objective (Carl Zeiss)....
-
SEM image and EDS map of SrTi0.50Fe0.50O3-d powder aglomerate
Open Research DataThis dataset contains image of the SrTi0.50Fe0.50O3-d powder aglomerate with EDS map analysis results. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage of 10 kV in a high vacuum mode. The chemical compositions of the investigated powder were determined...
-
SEM image and EDS map of SrTi0.65Fe0.35O3-d powder aglomerate
Open Research DataThis dataset contains image of the SrTi0.65Fe0.35O3-d powder aglomerate with EDS map analysis results. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage of 10 kV in a high vacuum mode. The chemical compositions of the investigated powder were determined...
-
SEM image and EDS map of SrTi0.30Fe0.70O3-d powder aglomerate
Open Research DataThis dataset contains image of the SrTi0.30Fe0.70O3-d powder aglomerate with EDS map analysis results. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage of 10 kV in a high vacuum mode. The chemical compositions of the investigated powder were determined...
-
Rating by detection: an artifact detection protocol for rating EEG quality with average event duration
PublicationQuantitative evaluation protocols are critical for the development of algorithms that remove artifacts from real EEG optimally. However, visually inspecting the real EEG to select the top-performing artifact removal pipeline is infeasible while hand-crafted EEG data allow assessing artifact removal configurations only in a simulated environment. This study proposes a novel, principled approach for quantitatively evaluating algorithmically...
-
Role for chitin and chitooligomers in the capsular architecture of Cryptococcus neoformans
PublicationW pracy opisano wyniki badań nad rolą struktur zawierających N-acetylo-D-glukozaminę (GlcNAc) w tworzeniu kapsuły otaczającej komórki patogennych dla człowieka grzybów Cryptococcus neoformans. Ekspresja w warunkach in vivo chitooligomerów łączących polisacharydy kapsuły ze ścianą komórkową jest różna, w zależności od rodzaju zainfekowanej tkanki, co określono poprzez wykazanie różnej reaktywności komórek form drożdżowych C. neoformans...
-
Elektrorozpylanie - dogodny sposób jonizacji analitów w przypadku stosowania bezpośrednich procedur pomiarowych opartych na wykorzystaniu spektrometrii mas
PublicationSpektrometria mas stanowi obecnie jedno z najważniejszych narzędzi analitycznych, stosowanych w celu oznaczania analitów występujących w próbkach o różnym pochodzeniu i składzie (próbki biologiczne, środowiskowe, żywność). Stosowanie tej techniki w sprzężeniu z rozdzielaniem chromatograficznym jest rozwiązaniem powszechnie stosowanym jednak w większości przypadków zachodzi konieczność oczyszczania, izolacji i wzbogacania analitów...
-
Ultra thick open tubular traps with an increased inner diameter.
PublicationPrzeanalizowano zagadnienia związane z zastosowaniem otwartych pułapek kapilarnych z grubym nieregularnym filmem polidimetylosiloksanu do wzbogacania lotnych związków organicznych. Przeprowadzone rozważania teoretyczne oraz prace eksperymentalne wykazały, że zwiększenie średnicy wewnętrznej pułapek może znacząco polepszyć ich właściwości. Dla danego natężenia przepływu próbki oraz danego stosunku objętości faz w pułapce, liczba...
-
High-Resolution, Broad-Range Detection Setup for Polarimetric Optical Fiber Sensors
PublicationA common-path polarization interferometer using a Wollaston prism and an area detector for the measurement of retardation or optical path difference is presented. Employing a moderate-resolution 1280 by 1024 pixel monochrome camera, it offers a measurement range of approximately 780 radians at 830 nm and 1350 radians at 515 nm while maintaining a high measurement resolution. Retardation introduced by a zero-order waveplate or a...
-
Marek Biziuk prof. dr hab. inż.
PeopleCURRICULUM VITAE Marek BIZIUK Born 1947 MSc 1969 GUT PhD 1977 GUT DSc 1994 GUT Professor 2001 Membership of scientific society - Gdansk Scientific Society - Romanian Society of Analytical Chemistry - Engineers and Techniques of...
-
Optical Parameters Stability Over Time of Porous Phantoms Mimicking Tissues
Open Research DataOptical phantoms are used to validate optical measurement methods. The stability of their optical parameters over time allows them to be used and stored over long-term periods while maintaining their optical parameters. The aim of the presented research was to investigate the stability of fabricated porous phantoms, which can be used as a lung phantom...
-
Microstructure of barium-vanadate glasses
Open Research DataThe structure of barium-vanadate glasses was measured by SEM and XRD techniques. Samples of the composition of xBaO-(100-x)V2O5 where x= 30, 40 and 45 (in %mol) were prepared by the conventional melt quenching technique. Appropriate amounts of reagents: BaO (≥99.9%, P.P.H STANLAB Sp.J.) and V2O5 (≥99.9%, POCH) were thoroughly mixed in an agate mortar....
-
Determination of the amount of wash amines and ammonium ion in desulfurization products of process gases and results of related studies
PublicationPrzedstawiono metodę oznaczania tzw. amin myjących i ich produktów degradacji, włączając jon amonowy w wodach procesowych i ściekach wytwarzanych podczas odsiarczania gazów. W procesach rafinacji ropy naftowej zastosowano jonowymienną chromatografię cieczową z detektorem refraktometrycznym oraz tanią kationowymienną kolumnę HPLC. Otrzymane wyniki oznaczeń porównano z wynikami uzyskanymi przez miareczkowanie potencjometryczne....
-
Metody realizacji pomiarów składowych natężenia promieniowania słonecznego dla monitoringu naukowego w różnych zakresach widmowych na potrzeby zastosowań fotowoltaicznych
PublicationW niniejszej pracy dokonano specyfikacji i analizy trybów monitorowania radiometrycznego systemów fotowoltaicznych. Przeprowadzono teoretyczne wprowadzenie do teorii detektorów termicznych i fotonowych. Zaprezentowano równania promieniowania krótkofalowego, długofalowego oraz bilansowego. Opisano profesjonalne komercyjne radiometry do specjalistycznych pomiarów meteorologicznych. Stwierdzono, że dla uzyskania szczegółowych danych...
-
SEM micrographs and photos of salivary gland stones
Open Research DataThis dataset contains SEM micrographs and high-resolution photographs taken for salivary gland stones (sialolith) extracted during joint studies between Medical University of Gdansk and Gdansk University of Technology.
-
SEM image and line EDS of SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C
Open Research DataThis dataset contains image of the SrTi0.50Fe0.50O3-d porous electrode sintered at 800 °C with line EDS analysis results. Images were obtained using a PhenomXL (Thermo Fisher Scientific, the Netherlands) scanning electron microscope (SEM) with an accelerating voltage of 20 kV in a high vacuum mode. The chemical compositions of the investigated powder...
-
Chromatografia gazowa z detekcją olfaktometryczną (GC-O) w analizie żywności. Cz. I. Charakterystyka metody
PublicationW ostatnich latach prowadzone są intensywne badania nad aktywnością sensoryczną poszczególnych składników zapachów żywności, a także napojów alkoholowych i nad zależnościami pomiędzy zapachem, a składem chemicznym lotnej frakcji tych produktów. Z oczywistych powodów największe zastosowanie w oznaczaniu lotnych substancji zapachowych znajduje chromatografia gazowa z różnymi wariantami detekcji. Większość osiągnięć w tej dziedzinie...
-
Bezpośrednia analiza próbek z wykorzystaniem techniki spektrometrii mas. Cz. II. Technika PTR – MS – ciekawe rozwiązanie metodyczne w zakresie spektrometrii mas
PublicationTechnika spektrometrii mas stanowi niezwykle istotne narzędzie badawcze, umożliwiające uzyskanie wielu cennych informacji, dotyczących składu chemicznego wielu próbek rzeczywistych pochodzenia biologicznego, farmaceutycznego i spożywczego. Spektrometr mas zazwyczaj pełni role detektora w przypadku stosowania połączenia z urządzeniami chromatograficznymi (GC, LC). Dzięki zastosowaniu pewnych modyfikacji aparaturowych i metodycznych,...
-
Nowe metodyki oznaczania dodatków do paliw z zastosowaniem rozdzielenia wielopomiarowego = New procedures for fuel additives determination by multidimensional separation systems
PublicationW pracy przedstawiono wyniki badań nad opracowaniem metodyki oznaczania wybranych dodatków "myjących" w paliwie diesla. Porównano metodyki jednoetapowe z wykorzystaniem chromatografii gazowej z detektorem płomieniowo-jonizacyjnym (GC-FID) lub spektrometrem mas (GC-MS) oraz wysokosprawnej chromatografii cieczowej z detektorem UV z matrycą fotodiodową (HPLC-UV-DAD), z metodykami dwuetapowymi, w których do wstępnej izolacji składników...
-
Analysis of pesticide residue in tomato samples using analytical protocol based on application of QuEChERS technique and GC-ECD system
PublicationQuEChERS sample preparation method was used for the determination of 10 pesticides and their metabolites in tomato samples, coupled to gas chromatography with electron capture detector (GCECD). The experimental parameters including oven temperature program, amount of the sample and purifying agent were optimized. The GC-ECD method was validated in terms of linearity, selectivity and recovery. The limits of detection (LODs) of the...
-
Photocatalytic ethylene decomposition with the use of fluidized bed photoreactor
Open Research DataData contain exported raw data recorded during decomposition of ethylene during utilization of fluidized bed photoreactor equipped with either UV-LEDs or fluorescent UV lamps as well as in either humid or dry conditions. In separate folder, the photographs of the photocatalytic system were included. As photocatalytic material, polystyrene spheres coated...
-
Ethylene decomposition on TiO2 under UV
Open Research DataData contain chromatograms recorded during decomposition of ethylene over TiO2 in a flow reactor under UV irradiation. Semilac UV lamp with total power of 72 W was used as a source of UV light. Chromatograms were recorded in Trace GC Ultra chromatograph equipped in FID detector. Sampling was realised via the dosing sample loop. TiO2 was coated on the...
-
Radioisotope measurements of the liquid-gas flow in the horizontal pipeline using phase method
PublicationThe paper presents application of the gamma-absorption method to a two-phase liquid-gas flow investigation in a horizontal pipeline. The water-air mixture was examined by a set of two Am-241 radioactive sources and two NaI(Tl) scintillation probes. For analysis of the electrical signals obtained from detectors the cross-spectral density function (CSDF) was applied. Results of the gas phase average velocity measurements for CSDF...
-
Nos elektroniczny - użyteczne narzędzie w analizie żywności
PublicationW artykule przedstawiono nowoczesne instrumentalne techniki stosowane w analizie związków zapachowych obecnych w żywności, a także ich przydatność w kontroli jakości produktów spożywczych. Główną uwagę poświęcono elektronicznym nosom. Opisano zasadę działania, zjawiska fizyczne i fizykochemiczne wykorzystywane przez czujniki takich urządzeń oraz metody analizy sygnału. Porównano tę metodę z techniką chromatografii gazowej sprzężonej...
-
Determination of estrogenic endocrine disruptors in environmental samples - a review of chromatographic methods
PublicationWśród związków endokrynnych to estrogeny zarówno naturalne jak i syntetyczne zostały wskazane i opisane jako związki niosące ze sobą największy potencjał aktywności estrogennej. Wysoki potencjał estrogenny jaki posiadają związki z grupy hormonów płciowych potwierdziły badania przeprowadzone zarówno in vitro jak i in vivo. W dużej części (50-95%) próbek ścieków pochodzących z oczyszczalni ścieków zostały wykryte związki z grupy...
-
Analog fault signature based on sigma-delta modulation and oscillation-test methodology.
PublicationW artykule dokonano przeglądu prac z zakresu testowania układów elektronicznych metodą oscylacyjną. Wskazując na niedostatki aktualnie stosowanej techniki testowania oscylacyjnego zaproponowano nową sygnaturę uszkodzeń dla układów analogowych. Proponowany parametr diagnostyczny jest wydobywany z odpowiedzi czasowej oscylatora testującego, w układzie złożonym z detektora szczytowego, modulatora sigma-delta oraz licznika rewersyjnego....
-
Porous Phantoms Mimicking Tissues – Investigation of Optical Parameter Stability Over Time
PublicationIn terms of optical parameters, optical phantoms can now replace live tissues and be used to validate optical measurement methods. Therefore, whether these parameters would be maintained after storage for 6 months was examined. The absorption and scattering coefficients were obtained from the measured transmittance and reflectance measurements taken 6 months apart and then compared. All of the measurements were conducted using...
-
The topography of Bi2VO5.5 ceramic measured with SEM and confocal microscope
Open Research DataThe topography of Bi2VO5.5 ceramics was measured by SEM and confocal microscope.