Filters
total: 460
filtered: 372
Chosen catalog filters
Search results for: FAILURE RATE
-
Entropy Measures of heart rate variability for short ECG datasets in patients with congestive heart failure
PublicationWe investigated the usefulness of entropy measures calculated for short ECG series in distinguishing healthy subjects from patients with congestive heart failure (CHF). Four entropy measures were tested: Approximate Entropy (ApEn), Sample Entropy (SampEn), Fuzzy Entropy (Fuzzy En) and Permutation Entropy (PE), each computed for ECG series of 1000, 500, 250 and 100 RR intervals. We found that with a reduction of the data set length...
-
Entropy measures of heart rate variability for short ECG datasets in patients with congestive heart failure
PublicationWe investigated the usefulness of entropy measures calculated for short ECG series in distinguishing healthy subjects from patients with congestive heart failure (CHF). Four entropy measures were tested: Approximate Entropy (ApEn), Sample Entropy (SampEn), Fuzzy Entropy (FuzzyEn) and Permutation Entropy (PE), each computed for ECG series of 1000, 500, 250 and 100 RR intervals. We found that with a reduction of the data set length...
-
Assessment of Failure Occurrence Rate for Concrete Machine Foundations Used in Gas and Oil Industry by Machine Learning
PublicationConcrete machine foundations are structures that transfer loads from machines in operation to the ground. The design of such foundations requires a careful analysis of the static and dynamic effects caused by machine exploitation. There are also other substantial differences between ordinary concrete foundations and machine foundations, of which the main one is that machine foundations are separated from the building structure....
-
Application of principal component and hierarchical cluster analysis in classifying defects of trolleybuses
PublicationThe failure rate of vehicles is a relevant task, which is strictly connected with the reliability of transportation systems. Methods of data analysis allow us to find similarity and differences between failure rates of several parts of trolleybuses. This paper deals with the statistic of failure of trolleybuses from the municipal transport company of Gdynia (Poland).
-
Analysis of Failures of High Speed Shaft Bearing System in a Wind Turbine
PublicationDuring the operation of wind turbines with gearbox of traditional configuration, consisting of one planetary stage and two helical stages high failure rate of high speed shaft bearings is observed. Such a high failures frequency is not reflected in the results of standard calculations of bearing durability. Most probably it can be attributed to atypical failure mechanism. The authors studied problems in 1.5 MW wind turbines of...
-
Study on deformed steel columns subjected to impact load due to soft-storey failure in buildings during earthquakes
PublicationThe so called soft-storey failure is one of the most typical types of damage induced in buildings as the result of earthquake excitation. It has been observed during ground motions that the failure of an upper soft storey of a structure results in large vertical impact load acting on the lower floors. If the resistance of the structural members of the lower storeys is not sufficient it may further lead to progressive collapse of...
-
RESEARCH OF PARTIAL DISCHARGE IN THE LABORATORY CONSTRUCTE
PublicationNowadays in the Czech Republic begins implementation of new types of leadership system with insulated conductors nowadays. This system is used because of the use of conductors in difficulties to reach terrains and lower failure rate. The finding of specific faults is problem, because today's digital protection are not able to find it.
-
ANALYSIS OF THE POSSIBILITIES OF HIGH SPEED SHAFT BEARING SYSTEM DURABILITY INCREASE
PublicationDuring the operation of wind turbines with a gearbox of traditional configuration, a high failure rate of high-speed shaft bearings is observed. Such a high failures frequency is not reflected in standard bearing durability calculation methods, which can be attributed to atypical failure mechanism. To avoid observed problems in the 1.5 MW wind turbine, the modification of the existing bearing system is proposed. Multiple options,...
-
Research on causes of corrosion in the municipal water supply system
PublicationThis paper presents results of failure analysis study to characterize the corrosion damage that occurred in the water supply system in Krakow. This analysis includes: electrochemical noise, linear polarization and resistometric measurements. Water aggressiveness of four water intakes was defined using Langelier and Ryznar indices. Results from this indices did not reveal the causes of considerable corrosion losses in water systems....
-
Load effect impact on the exploitation of concrete machine foundations used in the gas and oil industry
PublicationMachine foundations is a critical topic in the gas and oil industry, which design and exploitation require extensive technical knowledge. Machine foundations are the constructions which are intended for mounting on it a specific type of machine. The foundation has to transfer dynamic and static load from machine to the ground. The primary difference between machine foundations and building foundations is that the machine foundations...
-
Innovative Implantable Left Ventricular Assist Device—Performance under Various Resistances and Operating Frequency Conditions
PublicationThis paper presents the operation of an innovative left ventricular assist device under various resistances and operating frequencies. The operating principle of the device is based on pulsatile blood flow, which is forced by a suction–discharge device pumping helium into a set of intra-cardiac balloons. In this way, the ejection fraction of the left ventricle is increased, and the mitral valve is additionally occluded. What is...
-
Effect of Vascular Lumen Reduction on the Performance and Energy Consumption of an Innovative Implantable LVAD
PublicationThis paper presents the results of a study on the effect of vascular lumen reduction on the performance of an innovative implantable LVAD (left ventricular assist device). It details the pressures in the individual cardiac chambers as a function of device frequency. In addition, mass flow rates and energy consumption of the device are examined, varying with lumen reduction and operating frequency. While the lumen reduction of the...
-
BEARING SYSTEMS OF WIND TURBINES – MAINTENANCE PROBLEMS
PublicationW praktyce eksploatacyjnej turbin wiatrowych o tradycyjnej konstrukcji (przekładniowych) obserwowana jest duża awaryjność przekładni, a zwłaszcza łożysk tocznych szybkoobrotowych wałów przekładni. W Polsce na zlecenie właściciela dużej farmy wiatrowej, firmy Energa Wytwarzanie S.A., Politechnika Gdańska we współpracy z Politechniką Poznańską i Akademią Górniczo Hutniczą podjęły badania mające na celu diagnozowanie przyczyn uszkodzeń...
-
Microcracking monitoring and damage detection of graphene nanoplatelets-cement composites based on acoustic emission technology
PublicationThis study aims to identify the micro-cracking pattern and structural applications of cement composites replaced with 0 wt%, 0.04 wt%, and 0.08 wt% contents of graphene nanoplatelets (GNPs) over cement weight through acoustic emission (AE) monitoring under mechanical degradation. The ultraviolet-visible spectroscopy (UV–vis) results showed that at 60 min sonication period, GNP-4 showed maximum absorbance rate of 16.15% compared...
-
Complex Corrosion Monitoring System for Crude Distillation Unit in Form of Neutral Network
PublicationComplex and successful corrosion monitoring of refinery processes can significantly reduce material losses and failure risk. The developed corrosion monitoring system is based on online ultrasonic sensors, ER (electrical resistance) probes, gravimetric method and multipoint analytical analysis of chemical composition of the fluids. Additional online LPR (linear polarization resistance) sensors controlling corrosiveness of sour...
-
The fracture behaviour of notched PMMA specimens under simple loading conditions – Tension and torsion experimental tests
PublicationThis paper presents the results of experimental testing of flat PMMA specimens during uniaxial loading conditions. Two separate tests were conducted: tensile and torsion. The specimens were weakened with V-type edge notches with different root radii: 0.5; 2 and 10 mm. The specimens were made in two thickness variants: 5 and 15 mm. Monotonic tensile and torsion tests were carried out while keeping the averaged strain rate constant,...
-
Electrophoretic Deposition of Chitosan/Eudragit E 100/AgNPs Coatings for Controlled Release of Antibacterial Substance
PublicationThe development of bacterial infection of the tissues surrounding an implant is one of the leading causes of implant surgery failure. In order to prevent the deposition of bacteria on the implant surface and the formation of biofilm, coatings that exhibit antibacterial properties are manufactured. However, the problem is the controlled release of the therapeutic substance from the coating over the extended life of the implant [1],...
-
Cerclage cable augmentation does not increase stability of the fixation of intertrochanteric fractures. A biomechanical study
PublicationBackground: Intertrochanteric fractures with a posteromedial intermediate fragment are unstable because of the loss of medial support. Additional fixation with a cerclage is used in subtrochanteric fractures, but not in intertrochanteric fractures. The aim of this biomechanical study is to evaluate whether cerclage fixation improves stability of intertrochanteric fractures. Hypothesis: Our hypothesis is that the cerclage fixation...
-
The Influence of Impact Velocity on Stresses and Failure of S355j2 Steel Under Slurry Erosion Conditions
PublicationThe purpose of this work was to determine the essence of the influence of the impact velocity (5, 7, and 9 m/s) on Hertzian stresses and the erosion mechanism of ferritic-pearlitic S355J2 steel. The investigations were carried out using a slurry pot tester. S355J2 steel showed a strong sensitivity to changes in impact velocity. A significant increase in erosion rate was observed at a velocity of 9 m/s. This increase was 5-fold...
-
Measures of region failure survivability for wireless mesh networks
PublicationWireless mesh networks (WMNs) are considered as a promising alternative to wired local, or metropolitan area networks. However, owing to their exposure to various disruptive events, including natural disasters, or human threats, many WMN network elements located close to the failure epicentre are frequently in danger of a simultaneous failure, referred to as a region failure. Therefore, network survivability, being the ability...
-
FEM simulation of laminate failure in the three point bending
PublicationThe paper presents a FEM simulation of failure of laminate subjected to the three point bending. The numeri-cal model is based on the equivalent single layer approach with 6-paramater non-linear shell theory kinematics. It is implemented in the non-commercial FEM code. The failure initiation is detected with the use of Tsai-Wu criterion. After the failure onset the progressive failure process is modelled through the appropriate...
-
Tensile strength of a weave tendon suture using tendons of different sizes
PublicationThis study compared the maximum load, stress, elongation at failure and the mode of failure of three kinds of tendons most frequently used for tendon grafting and tendon transfers, using the Pulvertaftweave suture.
-
Examination of selected failure criteria with asymmetric shear stresses in the collapse analysis of laminated shells
PublicationThe paper is concerned with failure analysis of composite shells performed with the usage of the nonlinear 6‐parameter shell theory with drilling rotation degree of freedom. This special theory embodies naturally unlim-ited translations and rotations and is suitable for analysis of irregular shells for instance with various, partic-ularly orthogonal, intersections. The presence of the drilling rotation is inherently accompanied...
-
Electrolytic corrosion of water pipeline system in the remote distance from stray currents– case study
PublicationCase study of corrosion failure of urban water supply system caused by the harmful effects of stray currents was presented. The failure occurred at a site distant from the sources of these currents namely the tramway and railway traction systems. Diagnosis revealed the stray currents flow to pipeline over a remote distance of 800 ÷ 1,000 meters from the point of failure. At the point of failure stray currents flowed from the pipeline...
-
Progressive failure analysis of laminates in the framework of 6-field nonlinear shell theory
PublicationThe paper presents the model of progressive failure analysis of laminates incorporated into the 6-field non-linear shell theory with non-symmetrical strain measures of Cosserat type. Such a theory is specially recommended in the analysis of shells with intersections due to its specific kinematics including the so-called drilling rotation. As a consequence of asymmetry of strain measures, modified laminates failure criteria must...
-
Nonlinear FEM 2D failure onset prediction of composite shells based on 6-parameter shell theory
PublicationWithin the framework of the nonlinear 6-parameter shell theory with the drilling rotation and asymmetric stress measures, the modifications of Tsai-Wu and Hashin laminate failure initiation criteria are proposed. These improvements enable to perform first ply failure estimations taking into account the non-symmetric stress measures. In order to check the validity of the proposed criteria, finite element analyses are performed with...
-
Determination of Failure Causes of a Steam Turbine Casing
PublicationThe paper presents results of research and failure analysis undertaken to determine failure causes of a steam turbine casing. After 130,000 hours of service the crack in a outer shell of the turbine casing was found. The inner shell of the casing was made of cast steel grade G21CrMoV5-7, and the outer shell of grade G20CrMo4-5. Following research were performed in order to determine causes of the casing failure: chemical analysis;...
-
Experimental study on ultrasonic monitoring of splitting failure in reinforced concrete
PublicationThis paper investigates inspection of reinforced concrete elements sensitive to the splitting failure. The behaviour of a reinforced concrete specimen subjected to a tensile stress is considered. The damage detection procedure is based on the ultrasonic wave propagation technique. The piezoelectric transducers are located on both ends of the specimen and the measurements are taken periodically during the incrementally increased...
-
Mechanical response of human thoracic spine ligaments under quasi-static loading: An experimental study
PublicationPurpose This study aimed to investigate the geometrical and mechanical properties of human thoracic spine ligaments subjected to uniaxial quasi-static tensile test. Methods Four human thoracic spines, obtained through a body donation program, were utilized for the study. The anterior longitudinal ligament (ALL), posterior longitudinal ligament (PLL), capsular ligament (CL), ligamenta flava (LF), and the interspinous ligament and...
-
Failure characterisation of sandwich beams using integrated acoustic emission and digital image correlation techniques
PublicationThe paper presents the experimental study of the failure behaviour of sandwich beams subjected to bending. The samples examined are sandwich beams made of polyethylene terephthalate foam core and glass fibre-reinforced polymer laminate face sheets. In a series of experiments, it has been proposed to integrate diagnostic techniques with acoustic emission and digital image correlation to accurately track the cracking process on the...
-
Research on protection mechanisms of Resilient Packet Ring Network.
PublicationPaper describes iSteering - a new method to control traffic in case of RPR network failure. There's comparison of packet wrapping, steering and our proposed method iSteering, which can be used in case of transmitter/receiver or fiber failure. Numerical analysis for even and random traffic flow has been made in order to compare packet wrapping, steering and iSteering. The results of all the tests are included.
-
Examining Ownership Equity as a Psychological Factor on Tourism Business Failure Forecasting
PublicationThis paper examines ownership equity as a predictor of future business failure within the tourism and hospitality sectors. The main goals of this study were to examine which ratios are the most important for a tourism business failure forecasting model and how significant is the “total percentage of equity ownership by company directors” ratio compared with other ratios associated with the probability of bankruptcy. A stepwise...
-
Tripped at the Finishing Line: The Åland Islands Internet Voting Project
PublicationThe Åland Islands spent years preparing an internet voting system, to be implemented for the first time in October 2019 for Parliamentary Elections. Despite this, the project was canceled the evening before the expected release date. In this paper, we explore the causes of this failure using a two-pronged approach including Information System failure perspectives and the approach to e-voting Mirabilis, focusing on organizational...
-
Investigations on strength and fracture in RC beams scaled along height or length
PublicationThe objective of the present paper is to identify experimentally and theoretically differing failure mechanisms in reinforced concrete beams subjected to four-point bending for a separate variation of the depth and length at the constant thickness. Experiments were performed on reinforced concrete beams under four-point bending. Different failure mechanisms included steel yielding, diagonal tension or shear- compression depending...
-
Failure analysis of the exhaust valve face in diesel marine engine
PublicationThe exhaust valve from marine diesel engine which was damaged after 2000 hours of service was investigated. In order to prolong the service time the valve face was cladded with cobalt base alloy using laser technique. After failure microstructural and chemical analyses reviled that cladding process was conducted improperly. The chemical composition of the clad layer was far from the designed one and what more completely inhomogeneous....
-
In-plane shear nonlinearity in failure behavior of angle-ply laminated shells
PublicationThe paper concerns the progressive failure analysis of laminates with the in-plane shear nonlinearity accounted for.The nonlinear shear response of the layer is described by the constitutive relation treating the stresses as a function of strains. Thus it can be easily incorporated into the displacement-based FEM codes. The brittle failure mechanisms of the fibers and the matrix of the layer are recognized with the use of the Hashin...
-
Towards evaluation of the Second Generation Intact Stability Criteria - examination of a fishing vessel vulnerability to surf-riding, based on historical capsizing
PublicationThe Second Generation Intact Stability Criteria (SGISC) are the latest achievements in the field of intact ship stability assessment. The criteria are the result of massive international cooperative efforts and extensive research that lasted more than 15 years. Even though they are based on a solid scientific foundation, the trial period has commenced to collect user experience and further validation. One of possible approaches...
-
Threshold Attendance under Soft-Crash Model: TAG Protocol and Markovian Analysis
PublicationA realistic and systematic network evaluation should subsume an availability model and a failure model. We combine a "hard availability" model we call threshold attendance, whereby a certain minimum number of network elements must be present at any time, with a soft-crash failure model, whereby after experiencing a failure, a network element is still able to function correctly for a while in an emergency mode at a risk of a major...
-
Fundamental Schemes to Determine Disjoint Paths for Multiple Failure Scenarios
PublicationDisjoint path routing approaches can be used to cope with multiple failure scenarios. This can be achieved using a set of k (k> 2) link- (or node-) disjoint path pairs (in single-cost and multi-cost networks). Alternatively, if Shared Risk Link Groups (SRLGs) information is available, the calculation of an SRLG-disjoint path pair (or of a set of such paths) can protect a connection against the joint failure of the set of links...
-
A framework to analyse the probability of accidental hull girder failure considering advanced corrosion degradation for risk-based ship design
PublicationShip’s hull girder failure could result from maritime accident that can cause human life loss, environmental disaster, and major economic impacts. In risk-based ship design paradigm, accounting for rare phenomena (e.g. ship-ship collision or grounding) is important to provide safe and durable structure. In-service corrosion-induced hull degradation should be considered at the design stage, as it can significantly affect structural...
-
Approach to evaluation of time to the critical degradation of ship pipelines
PublicationIn the article an approach to the problem of estimating time to the critical degradation of ship pipelines is considered. Such an assessment would consist of six stages. The fundamental idea is to include to the estimation of time to failure of pipelines such elements like: materials that the pipelines are made, destructive physical phenomena taking place in them and applied means of protection. The result of that evaluation should...
-
Reliability-Based Stability Analysis of a Baltic Cliff by the Combined Response Surface Method
PublicationA simple, straightforward computational procedure was proposed, incorporating the Response Surface Method (RSM) linked with the standard Monte Carlo (MC) simulation method and the Point Estimate Method (PEM). PEM samples make it possible to analyse the sensitivity of the cliff’s stability to variation in subsoil parameters and to reduce the number of random variables of the problem. The proposed methods were tested in two cases:...
-
Critical analysis of laboratory measurements and monitoring system of water-pipe network corrosion-case study.
PublicationCase study of corrosion failure of urban water supply system caused by environmental factors was presented. Nowadays corrosion monitoring of water distribution systems is an object of major concern. There is possibility of application broad range of techniques like gravimetric and electrochemical. Both kinds of techniques can be applied in laboratory and field conditions. In many cases researches limit the case analysis to measurements...
-
Diagnostics and protection methods a residential building in connection with the reconstruction of a road located in its immediate neighborhood - case study
PublicationThe paper is a case study in the assessment of the technical condition of a residential building showing a significant degree of technical wear and tear, which was located in the impact zone of the road planned for expansion. Due to the commencement of works related to the expansion of the road, a doubt arose whether the road works carried out, in particular on the section along the residential building, would not cause further...
-
Recent Achievements in Constitutive Equations of Laminates and Functionally Graded Structures Formulated in the Resultant Nonlinear Shell Theory
PublicationThe development of constitutive equations formulated in the resultant nonlinear shell theory is presented. The specific features of the present shell theory are drilling rotation naturally included in the formulation and asymmetric measures of strains and stress resultants. The special attention in the chapter is given to recent achievements: progressive failure analysis of laminated shells and elastoplastic constitutive relation...
-
Fault-tolerant performance of the novel five-phase doubly-fed induction generator
PublicationThe article presents the concept of a new design of a multi-phase doubly-fed induction generator (DFIG). The innovative design approach uses a five-phase power supply from the rotor side of the generator with a three-phase classic stator power supply. Modern three-phase doubly-fed induction generators are the dominant choice for Wind Energy Conversion Systems (WECS). Solutions of this type are sensitive to the loss of at least...
-
Bearing capacity of the working platform with kinematic method
PublicationBearing capacity of the working platform for heavy tracks was analysed using Distinct Layout Optimization (DLO) method. The platform layer constructed from cohesionless soils is resting on weak cohesive subgrade. Different thickness of the platform, its effective angle of internal friction and undrained shear strength of the soft soil were taken into consideration. Kinematic method permits different failure mechanisms to be analyzed....
-
Failure of cold-formed beam: How does residual stress affect stability?
PublicationIn machine industry, stresses are often calculated using simple linear FEM analysis. Occasional failures of elements designed in such a way require recomputation by means of more sophisticated methods, eg. including plasticity and non-linear effects. It usually leads to investigation of failure causes and improvement of an element in order to prevent its unwanted behavior in the future. The study presents the case where both linear...
-
Modes of Failure Analysis in Reinforced Concrete Beam Using Laser Scanning and Synchro-Photogrammetry
PublicationThe following paper reveal the limitations and possibilities of terrestrial laser scanning technology adaptation in diagnostics of reinforced concrete beams. In this paper, authors present potential spectrum of TLS use in modes of failure analysis of R-C beams and determines under which conditions the laser technologies might be applied. Research was carried out at the Regional Laboratory of Structural Engineering at Gdansk University...
-
Modes of Failure Analysis in Reinforced Concrete Beam Using Laser Scanning and Synchro-Photogrammetry - How to apply optical technologies in the diagnosis of reinforced concrete elements?
PublicationThe following paper reveal the limitations and possibilities of terrestrial laser scanning technology adaptation in diagnostics of reinforced concrete beams. In this paper, authors present potential spectrum of TLS use in modes of failure analysis of R-C beams and determines under which conditions the laser technologies might be applied. Research was carried out at the Regional Laboratory of Structural Engineering at Gdansk University...