displaying 1000 best results Help
Search results for: strain gauge measurements
-
Reliability of Pulse Measurements in Videoplethysmography
PublicationReliable, remote pulse rate measurement is potentially very important for medical diagnostics and screening. In this paper the Videoplethysmography was analyzed especially to verify the possible use of signals obtained for the YUV color model in order to estimate the pulse rate, to examine what is the best pulse estimation method for short video sequences and finally, to analyze how potential PPG-signals can be distinguished from...
-
Measurements of Subnanometer Molecular Layers
PublicationSelected methods of formation and detection of nanometer and subnanometer molecular layers were shown. Additionally, a new method of detection and measurement with subnanometer resolution of layers adsorbed or bonded to the gate dielectric of the ion selective field effect transistor (ISFET) was presented.
-
Measurements of relative frequency instability
PublicationFrequency constancy can be determined by the change in time for the subsequent periods. The article shows that classical the method of digital period measurement is not suitable for the measurement process. Therefore, a method using an integrating circuit is being proposed. Errors in the measurement of the given method have been analyzed.
-
Correction of determined coordinates of railway tracks in mobile satellite measurements
PublicationThis article examines one of the basic issues related to the technique of mobile satellite measurements in railway tracks. This problem concerns the correction of the determined coordinates of the track centerline. The need to perform this operation results from the GNSS receivers positioning at a certain height above the level of the existing track axis, leading to longitudinal and lateral shifts of antennas. The key problem here...
-
Raman Spectra Measurements for Chemical Identifications - Aspect of Uncertainty Sources and Reduction of Their Effects
PublicationRaman spectrometers enable fast and non-contact identification of examined chemicals. These devices measure Raman spectra and compare with the spectra database to identify unknown and often illicit chemicals (e.g. drugs, explosives) usually without any sample preparation. Raman spectra measurements are a challenge due to noise and interferences present outside the laboratories (field applications). The design of a portable Raman...
-
Trust-Based Model for the Assessment of the Uncertainty of Measurements in Hybrid IoT Networks
PublicationThe aim of this paper is to introduce a NUT model (NUT: network-uncertainty-trust) that aids the decrease of the uncertainty of measurements in autonomous hybrid Internet of Things sensor networks. The problem of uncertainty in such networks is a consequence of various operating conditions and varied quality of measurement nodes, making statistical approach less successful. This paper presents a model for decreasing the uncertainty...
-
Channel Impulse Response Measurements at mmWave Band in Office and Conference Rooms
PublicationIn this paper, the measurements of the channel impulse response at mmWave band in office and conference rooms are described. The central frequency is 27 GHz with a bandwidth of 400 MHz. The description of the used measurement stand and considered environments are presented. The initial analysis of the power delay profile, mean delay, and RMS delay spread allows preliminary conclusions to be drawn that there is a significant impact...
-
Certified Reference Material - as a necessary tool for the quality control and quality assurance of measurements
PublicationReference materials are necessary to control and ensure the quality of the measurements. The demand for analytical information on the composition of different material objects makes it necessary to produce an even wider range of materials.
-
Wiktoria Wojnicz dr hab. inż.
PeopleDSc in Mechanics (in the field of Biomechanics) - Lodz Univeristy of Technology, 2019 PhD in Mechanics (in the field of Biomechanics) - Lodz Univeristy of Technology, 2009 (with distinction) List of papers (2009 - ) Wojnicz W., Wittbrodt E., Analysis of muscles' behaviour. Part I. The computational model of muscle. Acta of Bioengineering and Biomechanics, Vol. 11, No.4, 2009, p. 15-21 Wojnicz W., Wittbrodt E., Analysis of...
-
An in-depth look at the tire rubber hardness influence on tire/road noise measurements
PublicationWhen assessing the acoustic quality of a road pavement with the close-proximity (CPX) or the on-board sound intensity (OBSI) method, the rubber hardness of the reference tire substantially affects the measurement. Practical experience shows that measurement tires can get significantly harder within a single measurement season. This is why one would like to normalize measurements to a reference rubber hardness. The recently published...
-
Adaptive Wavelet-Based Correction of Non-Anechoic Antenna Measurements
PublicationNon-anechoic measurements represent an affordable alternative to evaluation of antenna performance in expensive, dedicated facilities. Due to interferences and noise from external sources of EM radiation, far-field results obtained in non-ideal conditions require additional post-processing. Conventional correction algorithms rely on manual tuning of parameters, which make them unsuitable for reliable testing of prototypes. In this...
-
Three modes of electrochemical impedance spectroscopy measurements performed on vanadium redox flow battery
PublicationThis article presents an innovative approach to monitor working redox flow batteries using dynamic electrochemical impedance spectroscopy, diverging from the commonly sequential impedance methods carried out under potentiostatic or galvanostatic conditions close to the open circle voltage. The authors introduce a fresh variation of dynamic impedance measurement that leverages an amplitude-modulated multi-frequency alternating current...
-
Extraction of antenna pattern from near field antenna measurements distorted by undesired emission
PublicationIn this paper authors present experimental correction of antenna pattern obtained from near field measurements when they are distorted by determined electromagnetic emission. Such situation may be met e.g. when feeding or supply subsystem interacts with antenna radiation pattern due to self-emission. Presented results of experiments show effectiveness of extraction of antenna pattern utilizing near field antenna measurements.
-
Performance Measurements of Real Time Video Transmission from Car Patrol
PublicationThe HSUPA technology application to video streaming from moving vehicle to the central server is presented in the paper. A dedicated software for transmission control in case of non public IP address is employed. Quality of video streaming in urban area was measured. Several car routes were investigated in the area of the Polish Tricity. Measurements pointed out that the real time streaming quality during vehicle movement is sufficient...
-
Permeability of sandy soils estimated from particle size distribution and field measurements
PublicationAccurate estimation of soil permeability is crucial in many geotechnical applications. Empirical and theoretical equations based on soil particle size distribution (PSD) offer a fast and cheap way for preliminary estimation of permeability in granular soils, however the results obtained from various formulas available in the literature often show significant discrepancies. While several comparative studies on this topic have been...
-
Investigation of the reliability of local strain analysis by means of the triangle modelling
Publication -
The pressure–strain work indices in response to isometric handgrip exercise
Publication -
Strain field of abdominal surface due to patients live excitations
PublicationPodano metodę opisu pola odkształceń powierzchni brzucha pacjenta podczas ruchów jego tułowia. Wyróżniono strefy brzucha o zróżnicowanej wielkości odkształceń ekstremalnych.
-
Ewaluation of a PCR Melting Profile technique for bacterial strain differentiation
PublicationBadano przydatność techniki PCR MP w efektywnym typowaniu szczepów w badaniach epidemiologicznych zakażeń szpitalnych. Technika oparta jest na użyciu niskiej temperatury denaturacji podczas LM PCR. Badaniu zostały poddane izolaty Escherichia coli pochodzące od pacjentów Szpitala Klinicznego w Gdańsku. Wykazano, że technika jest szybka, o wysokim potencjale różnicującym i bardzo dobrej powtarzalności i może być zastosowana w badaniach...
-
Stress strain relations and modulus of elascity of two stage concrete.
PublicationOmówiono badania doświadczalne przeprowadzone dla betonu dwuetapowego. Beton wykonano z trzech różnych kruszyw przy zastosowaniu trzech różnych proporcji w/c i c/p. Wyznaczono związki pomiędzy naprężeniami i odkształceniami. Na drodze statystycznej opracowano wzory umożliwiające wstępne szacowanie wartości siecznego modułu Younga. Ponieważ metoda dwuetapowa pozwala na zachowanie kontaktu pomiędzy poszczególnymi elementami kamiennego...
-
Time-of-flight fiber optic sensors for strain and temperature measurement
PublicationW pracy przedstawiono światłowodowy sensor czasu przelotu do pomiaru odkształceń i temperatury mogący pracować zarówno w modzie transmisyjnym, jak i odbiciowym. W pomiarach czasu przelotu wykorzystano krótkie impulsy światłowodowe wprowadzane do jednodomowego światłowodu. Pod wpływem czynników zewnętrznych (temperatura, odkształcenie, siła rozciągająca) zmieniała się droga optyczna w światłowodzie, co powodowało zmiany czasu przelotu...
-
Scale effects in granular bodies during plane strain compression.
PublicationW arykule omówiono efekty skali w materiałach granulowanych spowodowanych wielkością próbek. Obliczenia wykonano stosując MES na bazie prawa hipoplastycznego rozszerzonego o długość charakterystyczną. Porównano różne metody regularyzacji.
-
Damped forced vibration analysis of single-walled carbon nanotubes resting on viscoelastic foundation in thermal environment using nonlocal strain gradient theory
PublicationIn this paper, the damped forced vibration of single-walled carbon nanotubes (SWCNTs) is analyzed using a new shear deformation beam theory. The SWCNTs are modeled as a flexible beam on the viscoelastic foundation embedded in the thermal environment and subjected to a transverse dynamic load. The equilibrium equations are formulated by the new shear deformation beam theory which is accompanied with higher-order nonlocal strain...
-
On well-posedness of the first boundary-value problem within linear isotropic Toupin–Mindlin strain gradient elasticity and constraints for elastic moduli
PublicationWithin the linear Toupin–Mindlin strain gradient elasticity we discuss the well-posedness of the first boundary-value problem, that is, a boundary-value problem with Dirichlet-type boundary conditions on the whole boundary. For an isotropic material we formulate the necessary and sufficient conditions which guarantee existence and uniqueness of a weak solution. These conditions include strong ellipticity written in terms of higher-order...
-
Low-Level Aerial Photogrammetry as a Source of Supplementary Data for ALS Measurements
PublicationThe development of laser scanning technology ALS allows to make high-resolution measurements for large areas result-ing in significant reduction of costs. The main stakeholders at heights data received from the airborne laser scanning is mainly state administration. The state institutions appear among projects such as ISOK. Each point is classified in ac-cordance with the standard LAS 1.2, our research focuses on the class 6 -...
-
Representativity of ISO test track surface based on controlled pass-by measurements
PublicationWithin the Polish-Norwegian research project ELANORE, a limited Round Robin Test has been performed on four ISO tracks in Northern Europe. The basic objective of the project is to improve the EU directive on labelling of tyres for noise and rolling resistance. This directive is based on the measurement procedures proscribed in the UNECE Reg.117. Measurements on 3 ISO tracks were performed in 2021 and presented at InterNoise 2022....
-
Determining horizontal curvature of railway track axis in mobile satellite measurements
PublicationThe article discusses the applicability of a novel method to determine horizontal curvature of the railway track axis based on results of mobile satellite measurements. The method is based on inclination angle changes of a moving chord in the Cartesian coordinate system. In the presented case, the variant referred to as the method of two virtual chords is applied which consists in manoeuvring with only one GNSS (Global Navigation...
-
Accuracy assessment of mobile satellite measurements in relation to the geometrical layout of rail tracks
PublicationThe paper presents the campaigns of mobile satellite measurements, carried out in 2009–2015 on the railway and tram lines. The accuracy of the measurement method has been analysed on the basis of the results obtained in both horizontal and vertical planes. The track axis deviation from the defined geometric shape has been analysed in the areas clearly defined in terms of geometry, i.e. on the straight sections and sections with...
-
Monitoring of breast tissue thermo-ablation by means of impedance measurements
PublicationW pracy przedstawiono rozważania dotyczące monitorowania jakości termoablacji zmian nowotworowych w piersi przy pomocy pomiarów impedancyjnych. Pokazano prototypowe konstrukcje sond do termoablacji jak również zaprezentowano wyniki symulacji i pierwszych eksperymentów. A usefulness of a developed probe combining power delivery to ablated breast tumour and simultaneous impedance measurements is discussed in the paper. It consists...
-
Implementation and Validation of Multisinusoidal, Fast Impedance Measurements in Atomic Force Microscope Contact Mode.
PublicationThis study presents a novel approach to impedance measurements. The methodology discussed is limited to contact in the sample-probe system under ambient conditions without the presence of electrolyte. Comparison with results of direct and alternating current measurements for well-defined metallic surfaces are made. In spite of idealization related to the type of contact examined, the proposed technique provides an improvement of...
-
Processed measurements of AuAg nanostructures
Open Research DataExtensive processed UV-vis measurements of AuAg alloyed nanostructures created from thin films. Plasmonic band position dependence on fabrication parameters.
-
Radio Channel Measurements in Off-Body Communications in a Ferry Passenger Cabin
PublicationThis paper presents an off-body radio channel measurements in a ferry passenger cabin at 2.45 GHz band, for static sleeping scenarios with different body orientation and on-body antennas placements, and also for upper and lower sleeping berths. The measurements have been performed with two types of on-body wearable receiving antennas: FlexPIFA (flexible planar inverted F antenna), and FlexNotch (flexible adhesive-backed notch antenna)...
-
Monitoring of lysozyme thermal denaturation by volumetric measurements and nanoDSF technique in the presence of N-butylurea
PublicationThe results of thermal studies of denaturation of hen egg white lysozyme (HEWL) in water and an aqueous solution of N-butylurea (BU) are presented. High-precision densimetric measurements were used to characterize and analyze the changes of the specific volume, v, during temperature elevation. The temperature of the midpoint of protein denaturation was also determined by nanoDSF technique (differential scanning fluorimetry). The...
-
Testing of the longest span soil-steel bridge in Europe – new quality in measurements
PublicationThe article describes interdisciplinary and comprehensive diagnostic tests of final bridge inspection and acceptance proposed for a soil – steel bridge made of corrugated sheets, being the European span length record holder (25.74 m). As an effect of an original concept a detailed and precise information about the structure response was collected. The load test design was based on the nonlinear numerical simulations performed by...
-
Radio Channel Measurements in Body-to-Body Communications in Different Scenarios
PublicationThis paper presents body-to-body radio channel measurements at the 2.45 GHz band, for different body motion scenarios and on-body antenna placements, and both indoor and outdoor environments. Measurement equipment, investigated scenarios and considered environments are described, an initial analysis of results being presented. The mean path loss and the standard deviation depend on the mutual location of transmitting and receiving...
-
Radio Channel Measurements in Body-to-Body Communications in Different Scenarios
PublicationThis paper presents body-to-body radio channel measurements at the 2.45 GHz band, for different body motion scenarios and on-body antenna placements, and both indoor and outdoor environments. Measurement equipment, investigated scenarios and considered environments are described, an initial analysis of results being presented. The mean path loss and the standard deviation depend on the mutual location of transmitting and receiving...
-
In-situ and ex-situ resistance measurements of polypyrrole film using double-band electrode
PublicationMany in-situ techniques are performed in order to determine the resistance of conducting polymer film. However, the resistance measured in solution can be the combination of polymer resistance and that of other components, such as resistance of supporting electrolyte. Therefore, in this work, the influence of the solution on the resistance of polypyrrole (PPy) film has been studied. PPy film was electrchemically synthesized onto...
-
The Positioning Accuracy of BAUV Using Fusion of Data from USBL System and Movement Parameters Measurements
PublicationThe article presents a study of the accuracy of estimating the position coordinates of BAUV (Biomimetic Autonomous Underwater Vehicle) by the extended Kalman filter (EKF) method. The fusion of movement parameters measurements and position coordinates fixes was applied. The movement parameters measurements are carried out by on-board navigation devices, while the position coordinates fixes are done by the USBL (Ultra Short Base...
-
Methodology for Performing Bathymetric Measurements of Shallow Waterbodies Using an UAV, and their Processing Based on the SVR Algorithm
PublicationState-of-art methods of bathymetric measurements for shallow waterbodies use Global Navigation Satellite System (GNSS) receiver, bathymetric Light Detection and Ranging (LiDAR) sensor or satellite imagery. Currently, photogrammetric methods with the application of Unmanned Aerial Vehicles (UAV) are gathering great importance. This publication aims to present step-by-step methodology for carrying out the bathymetric measurements...
-
Methodology for Performing Bathymetric Measurements of Shallow Waterbodies Using an UAV, and their Processing Based on the SVR Algorithm
PublicationState-of-art methods of bathymetric measurements for shallow waterbodies use Global Navigation Satellite System (GNSS) receiver, bathymetric Light Detection and Ranging (LiDAR) sensor or satellite imagery. Currently, photogrammetric methods with the application of Unmanned Aerial Vehicles (UAV) are gathering great importance. This publication aims to present step-by-step methodology for carrying out the bathymetric measurements...
-
DMI measurements impact on a position estimation with lack of GNSS signals during Mobile Mapping
PublicationNowadays, Mobile Laser Scanning is common in use in addition to geodesy measurements. The data which are provided by the system characterizes with high precision and flexibility. To precise mapping, the accuracy of the data should be maintained. In Poland, according to the minister’s dispositions, the accuracy of the data should not exceeded 10 cm. With fully operated system it is easy to uphold, but there is a situation when a...
-
Measurements of Two-phase Flows in Pipelines Using Radioisotopes and Statistical Signal Processing
PublicationThis paper presents an application of radiotracers and gamma absorption method in two-phase flow measurements in pipelines. Two different methods were implemented to analysis of acquired signals. Investigated methods are based on the cross-correlation function and the phase of the cross-spectral density distribution. The examples presented in the article illustrate the application of the radioisotopes to evaluation of liquid-gas...
-
Prototype of electrochemical sensor for measurements of volatile organic compounds in gases
PublicationThe paper presents a laboratory prototype of an electrochemical sensor for measurements of volatile organic compounds (VOCs) in gases, utilizing ionic liquids and commercial screen printed electrodes by DropSens. The following ionic liquids have been tested as the electrolyte and redox reaction environment: 1-butyl, 3-methylimidazolium dicyanoamide ([BMIM][N(CN)2]), 1-octyl, 3-methylimidazolium tetrafluoroborate ([OMIM][BF4]),...
-
Recent total cross section measurements in electron scattering from molecules
PublicationThe grand-total cross sections (TCSs) for electron scattering from a range of molecules, measured over the period 2009-2019 in various laboratories, with the use of different electron transmission systems, are reviewed. Where necessary, the presented TCS data are also compared to earlier results. Collection of investigated molecular targets (biomolecules, biofuels, molecules of technological application,hydrocarbons) reflects their...
-
Accurate Post-processing of Spatially-Separated Antenna Measurements Realized in Non-Anechoic Environments
PublicationAntenna far-field performance is normally evaluated in expensive laboratories that maintain strict control over the propagation environment. Alternatively, the responses can be measured in non-anechoic conditions and then refined to extract the information on the structure field-related behavior. Here, a framework for correction of antenna measurements performed in non-anechoic test site has been proposed. The method involves automatic...
-
Tyre/road noise measurements on ISO tracks according to the UNECE Regulation 117
PublicationWithin the Polish-Norwegian research project ELANORE, a limited Round Robin Test has been performed on 3 ISO tracks in Northern Europe. The basic objective of the project is to improve the EU directive on labelling of tyres for noise and rolling resistance, and this directive is based on the measurement procedures defined in the UN ECE Reg.117. The same test car, test tyres and measurement equipment as well as personnel were used...
-
Accuracy Analysis of Measurements in Electrochemical Biosensing
Publication -
Rolling resistance measurements of studded tires
PublicationW pracy przedstawiono wyniki pomiaru oporu toczenia opon kolcowanych i po usunięciu kolców na nawierzchni poroelastycznej. Badania przeprowadzono na stanowisku bębnowym Katedry Pojazdów i Maszyn Roboczych Politechniki Gdańskiej. Opony kolcowane mają o około 5% wyższy współczynnik oporu toczenia w porównaniu z oponami nie kolcowanymi.
-
Hardness measurements for assessment of cavitation intensity
PublicationArtykuł opisuje możliwość zastosowania pomiarów teardości erodowanego materiału do oceny natężenia zjawiska kawitacji. Proponowana metoda zakłada, że cała energia implodujących pęcherzyków kawitacyjnych zamieniana jest na przyrost twardości warstwy wierzchniej materiału
-
Emissivity Measurements on Shape Memory Alloys
Publication