Wyniki wyszukiwania dla: SMALL SIGNAL ADMITTANCE SPECTRA
-
Electric transport in organic system with planar DBP/F16ZnPc junction on the basis of direct current and small signal admittance spectra analysis
PublikacjaThe objective of this work was to determine electric transport in the organic device based on a planar junction of electron donor and electron acceptor materials, namely ITO/MoO3/DBP/F16ZnPc/BCP/Ag. The analysis reported herein was based on direct current-voltage measurements and small-signal admittance spectra in the dark and under illumination. Such analysis may provide information on potential barriers, parasitic resistances...
-
Small-signal admittance for Schottky-Richardson emission into an organic layer
PublikacjaPraca przedstawia małosygnalową admitancję emisji Schottky'ego-Richardsona do warstwy organicznej. Analiza obejmuje obie składowe zespolonej odpowiedzi.
-
Small signal admittance spectroscopy applied for extraction of charge carrier mobility in thin organic layers
PublikacjaPraca przedstawia nowy sposób wyznaczania ruchliwości nośników ładunku w cienkich warstwach organicznych w oparciu o pomiary widm małosygnałowej admitancji.
-
On small signal capacitance spectra of organic diode formed by ITO-palladium phthalocyanine-Al sandwich system
PublikacjaPraca poświęcona jest widmom małosygnalowej pojemności w zakresie 25 Hz-1 MHz i charakterystyce prądowo-napięciowej planarnego układu utworzonego przez ITO/ftalocyanina palladu/Al.
-
Small signal spectra of complex capacitance obtained on organic heterojunction formed from copper phthalocyanine and perylene dye
PublikacjaPraca przedstawia małosygnałowe widma zespolonej pojemności otrzymane na strukturze z heterozłączem organicznym CuPc/Py-PTC w zakresie 25Hz-1MHz.
-
Effect of electrode resistance on admittance spectra of planar organic device carrying SCLC and on charge carrier mobility extracted from susceptance
PublikacjaThe work presents small signal admittance spectra of a sandwich system with thin organic layer carrying a space charge limited current. The effect of series resistance of electrodes on the spectra is discussed. Spectra of small signal capacitance are added to get more detailed insight. The analysis performed shows that the series resistance can affect both parts of small signal response within a whole range of frequency. Moreover,...
-
Effect of shallow traps on admittance spectra of the system carrying SCLC and on values of charge carrier mobility extracted from susceptance
PublikacjaThe work concerns small-signal spectra of space-charge-limited current below threshold frequency (ft) of shallow traps. It is shown that below ft the small-signal concentration of trapped charge carriers is proportional to and in phase with small-signal concentration of free charge carriers, so there is no room for “slow shallow traps”. Conductance can be reduced by the traps, however no change in the range of real capacitance...
-
A quasi-2D small-signal MOSFET model - main results
PublikacjaDynamic properties of the MOS transistor under small-signal excitation are determined by kinetic parameters of the carriers injected into the channel, i.e., the low-field mobility, velocity saturation, mobility at the quiescent-point (Q-point), longitudinal electric field in the channel, by dynamic properties of the channel, as well as by an electrical coupling between the perturbed carrier concentration in the channel and the...
-
TIME- AND FREQUENCY-DOMAIN QUASI-2D SMALL-SIGNAL MOSFET MODELS
PublikacjaA novel approach to small-signal MOSFET modeling is presented in this book. As a result, time- and frequency-domain physics-based quasi-2D NQS four-terminal small-signal MOSFET models are proposed. The time-domain model provides the background to a novel DIBL-included quasi‑2D NQS four-terminal frequency-domain small-signal MOSFET model. Parameters and electrical quantities of the frequency-domain model are described by explicit...
-
A quasi-2D small-signal MOSFET model - main results
PublikacjaMain results stemming from a new quasi 2D non-quasi-static small-signal four-terminal model of the MOSFET are presented in this work. The model is experimentally verified up to 30 GHz.
-
Electric properties of an Au-CuPc-Au sandwich system: Direct current and low signal admittance studies
PublikacjaPraca przedstawia wyniki pomiarów stałoprądowych i niskosygnałowej admitancji układu złoto/ftalocyjanina miedzi/złoto. Obserwowana asymetria charakterystyk stałoprądowych sugeruje, że prąd elektryczny płynący przez układ jest prądem ograniczonym elektrodowo i wydajność wstrzykiwania dziur jest uwarunkowana kolejnością nanoszenia warstw. W przypadku wstrzykiwania dziur przez bardziej regularną międzypowierzchnię (tj. gdy ftalocyjanina...
-
Compatible DC and small-signal MOSFET models for radio and microwave frequency simulation
PublikacjaZaprezentowano nowy model stałoprądowy tranzystora MOS i kompatybilny z nim uogólniony nie-quasi-statyczny model małosygnałowy. Model stałoprądowy został eksperymentalnie zweryfikowany dla tranzystorów MOS o długości kanału od 75 nm do kilkunastu mikrometrów, a model małosygnałowy od zera herców do 30 GHz.
-
A non-quasi-static small-signal model of the four-terminal MOSFET for radio and microwave frequencies.
PublikacjaW pracy zaprezentowano nowy małosygnałowy model tranzystora MOS, w którymuwzględnia się efekt nasycenia prędkości nośników. Model jest spójny fizycznie i może być stosowany w analizie dowolnej konfiguracji włączenia tranzystora.
-
Zbigniew Czaja dr hab. inż.
OsobyZbigniew Czaja was born in Czluchow, Poland, in 1970. He graduated from Gdansk University of Technology, Faculty of Electronics, Telecommunications and Informatics in 1995. The Ph.D. degree in electronics was received in 2001 from the same university. He worked as assistant professor at this university from 2002 to 2013. In 2014, he qualified as an associate professor, and in 2017, as a professor. His research interests are in...
-
A small-signal sound speed and parameter of non-linearity B/Ain a ternary mixture. Examples of calculations of mixture consisting of air, water and water vapor
PublikacjaZostało wyliczone zaburzenie entropii z dokładnością do członów nieliniowych rzędu drugiego. Jedyne założenie ograniczające, toże para wodna i powietrze są gazami doskonałymi. Ostatecznie,parametr nieliniowości i prędkość fali akustycznej przedstawione jako rodzinę krzywych, zależnych od trzech parametrów. Przedstawiono ilustrację tych zależności.
-
Electrical properties of hybrid planar diode based on palladium phthalocyanine and titanium dioxide
PublikacjaThis work details experimental studies of a planar diode made of indium tin oxide/titanium dioxide/palladium phthalocyanine/gold. The rectification ratio of current was 105 at 1.5 V. The analysis of the electrical properties of the system was based on small signal complex capacitance spectra measured in the frequency range of 25 Hz-1 MHz at different values of bias. No depletion region at the TiO2/PdPc interface was observed. Forward...
-
Raman Spectra Measurements for Chemical Identifications - Aspect of Uncertainty Sources and Reduction of Their Effects
PublikacjaRaman spectrometers enable fast and non-contact identification of examined chemicals. These devices measure Raman spectra and compare with the spectra database to identify unknown and often illicit chemicals (e.g. drugs, explosives) usually without any sample preparation. Raman spectra measurements are a challenge due to noise and interferences present outside the laboratories (field applications). The design of a portable Raman...
-
Enhancement of self-trapped excitons and near-infrared emission in Bi3+/Er3+ co-doped Cs2Ag0.4Na0.6InCl6 double perovskite
Dane BadawczeErbium (Er) complexes are used as optical gain materials for signal generation in the telecom C-band at 1540 nm, but they need a sensitizer to enhance absorption. Na+ substitution for Ag+ and Bi3+ doping at the In3+ site is a possible strategy to enhance the broadband emission of Cs2AgInCl6, which could be used as a sensitizer for energy transfer to...
-
Application of the Fractional Fourier Transform for dispersion compensation in signals from a fiber-based Fabry-Perot interferometer
PublikacjaOptical methods of measurement do not require contact of a probe and the object under study, and thus have found use in a broad range of applications such as nondestructive testing (NDT), where noninvasive measurement is crucial. Measuring the refractive index of a material can give a valuable insight into its composition. Low‑coherence radiation sources enable measurement of the sample’s properties across a wide spectrum, while...
-
Influence of vacuum sublimation deposited metal layer thickness on metrological parameters of the amperometric gas sensor with Nafion membrane
PublikacjaThe paper presents the results of investigation on an influence of vacuum sublimation deposited platinum layer thickness on the signal, sensitivity and response time of a prototype of sulphur dioxide sensor with Nafion membrane. The working electrode was made by vacuum sublimation deposition of platinum on a surface of Nafion membrane. Pt layers deposited changed an initial structure of Nafion membrane and that phenomenon was utilized...
-
Wykorzystanie metody Neldera-Meada do identyfikacji wartości parametrów niequasi-statycznego modelu małosygnałowego tranzystora MOS
PublikacjaW artykule zaprezentowano wyniki zastosowania metody sympleksu Neldera-Meada do ekstrakcji wartości parametrów niequasi-stycznego modelu małosygnałowego tranzystora MOS. Przedstawiono równoważny elektryczny schemat zastępczy i model matematyczny nowego modelu małosygnałowego MOSFETa dla częstotliwości mikrofalowych. Opisano zaimplementowany algorytm i otrzymane rezultaty badań.
-
Study of the atomic structure and morphology of the Pt3Co nanocatalyst
PublikacjaThe local structure and chemical disorder of a commercially available Pt3Co nanocatalyst supported on high surface area carbon were investigated. High-quality XAFS spectra were collected at the ELETTRA synchrotron XAFS 11.1 beamline. XAFS spectra analysis have been performed accounting for the reduction of the coordination number and degeneracy of three-body configurations, resulting from transmission electron microscopy (TEM)...
-
Wavelet filtering of signals without using model functions
PublikacjaThe effective wavelet filtering of real signals is impossible without determining their shape. The shape of a real signal is related to its wavelet spectrum. For shape analysis, a continuous color wavelet spectrogram of signal level is often used. The disadvantage of continuous wavelet spectrogram is the complexity of analyzing a blurry color image. A real signal with additive noise strongly distorts the spectrogram based on continuous...
-
Noise sources in Raman spectroscopy of biological objects
PublikacjaWe present an overview of noise sources deteriorating the quality of the recorded biological Raman spectra and the ability to determine the specimen composition. The acquired Raman spectra exhibit intense additive noise components or drifts because of low intensity of the scattered light. Therefore we have to apply expensive or bulky measurement setups to limit their inherent noise or to apply additional signal processing to reduce...
-
Identification of inherent noise components of semiconductor devices on an example of optocouplers
PublikacjaIn the paper, a method of estimation of parameters of Gaussian and non-Gaussian components in the noise signal of semiconductor devices in a frequency domain is proposed. The method is based on composing estimators of two spectra, corresponding to noise (Gaussian component) and two-level RTS noise (non-Gaussian component). The proposed method can be applied for precise evaluation of the corner RTS frequency fRTS in the noise...
-
Comment on "On accurate capacitance characterization of organic photovoltaic cells"
PublikacjaIn the 100th volume of Applied Physics Letters Carr and Chaudhary have presented a work on capacitance characterization of organic photovoltaic cells. The work concerns small signal measurements of various organic photovoltaic structures. The authors however limit their considerations to one part of small signal response, namely to capacitance measured either in parallel mode or in series mode. This attitude generally does not...
-
Electronic States of Tris(bipyridine) Ruthenium(II) Complexes in Neat Solid Films Investigated by Electroabsorption Spectroscopy
PublikacjaWe present the electric field-induced absorption (electroabsorption, EA) spectra of the solid neat films of tris(bipyridine) Ru(II) complexes, which were recently functionalized in our group as photosensitizers in dye-sensitized solar cells, and we compare them with the results obtained for an archetypal [Ru(bpy)3]2+ ion (RBY). We argue that it is difficult to establish a unique set of molecular parameter values by discrete parametrization...
-
The Doppler effect in a bistatic system for determining the position of moving targets
PublikacjaThe article presents the theoretical analysis and the results of numerical calculations of the Doppler effect it occurs in a system designed to determine the position and speed of a moving target. The transmitter is the source of the signal and it emits a sinusoidal, acoustic and continuous wave. Signal reflected off a moving target is received by four hydrophones. Based on the signals, four Doppler shifts are determined and inserted...
-
On adaptive covariance and spectrum estimation of locally stationary multivariate processes
PublikacjaWhen estimating the correlation/spectral structure of a locally stationary process, one has to make two important decisions. First, one should choose the so-called estimation bandwidth, inversely proportional to the effective width of the local analysis window, in the way that complies with the degree of signal nonstationarity. Too small bandwidth may result in an excessive estimation bias, while too large bandwidth may cause excessive...
-
Enhancement of fiber-optic low-coherence Fabry-Pérot interferometer with ZnO ALD films
PublikacjaIn this paper investigation of the enhanced fiber-optic low coherence Fabry-Pérot interferometer with zinc oxide (ZnO) film deposited by atomic layer deposition (ALD) was presented. Model of the interferometer, which was constructed of single-mode optical fiber with applied ZnO ALD films, was built. The interferometer was also examined by means of experiment. Measurements were performed for both reflective and transmission modes,...
-
High Efficiency Dual-Active-Bridge Converter with Triple-Phase-Shift Control for Battery Charger of Electric Vehicles
PublikacjaAn optimal modulation scheme with triple-phase-shift (TPS) control could increase the efficiency in the entire load range for a dual-active-bridge (DAB) converter under wide output voltage range conditions. Therefore, this study proposes a convergent approach to TPS mode selection, coupled with an optimal modulation scheme, ensuring the circuit’s efficiency over the entire range in the realm of a high-power and high-efficiency...
-
Comment on "Quantitative comparison of analysis methods for spectroscopic optical coherence tomography"
PublikacjaIn a recent paper by Bosschaart et al. [Biomed. Opt. Express 4, 2570 (2013)] various algorithms of time-frequency signal analysis have been tested for their performance in blood analysis with spectroscopic optical coherence tomography sOCT). The measurement of hemoglobin concentration and oxygen saturation based on blood absorption spectra have been considered. Short time Fourier transform (STFT) was found as the best method for...
-
Properties of Thermally Dewetted Thin Au Films on ITO-Coated Glass for Biosensing Applications
PublikacjaNoble metal nanostructures are object of great interest due to their unique optical and electronic properties exploited in nanotechnology, medicine, biochemistry, and surface-enhanced spectroscopies. In this work, the Au nanoparticle (NP) structures for application in biosensing obtained by dewetting are investigated in dependence on their preparation conditions. Structures are produced from thin Au films (5–30 nm) sputtered onto...
-
On adaptive selection of estimation bandwidth for analysis of locally stationary multivariate processes
PublikacjaWhen estimating the correlation/spectral structure of a locally stationary process, one should choose the so-called estimation bandwidth, related to the effective width of the local analysis window. The choice should comply with the degree of signal nonstationarity. Too small bandwidth may result in an excessive estimation bias, while too large bandwidth may cause excessive estimation variance. The paper presents a novel method...
-
Assessment of copper surface coverage with corrosion inhibitor using AFM-based local electrical measurements
PublikacjaThe paper presents a new method of assessment of metal surface coverage with corrosion inhibitor and thus of inhibitor protective performance. It is based on the atomic force microscopy measurement performed in a contact mode. Apart from topography images the proposed approach allows acquisition of local DC maps and local electrical impedance spectra via application of DC bias voltage or AC perturbation signal between the conductive...
-
A Novel Ru(II) Polypyridine Black Dye Investigated by Resonance Raman Spectroscopy and TDDFT Calculations
PublikacjaThe optical properties of a new(bipyridine)2Ru(4H-imidazole) complex presenting a remarkablebroad absorption in the visible range are investigated. Thestrong overlap of the absorption with the solar radiationspectrum renders the studied complex promising as a blackabsorber and hence as a starting structure for applications inthe field of dye-sensitized solar cells. The correlations betweenstructural and electronic features for...
-
Applications of Raman spectroscopy for detection of selected substances in tissues
PublikacjaThis dissertation explores the applications of Raman spectroscopy for biological tissue analysis. Basics of Raman and surface-enhanced Raman spectroscopy (SERS) are described, along with an analysis of the literature on biodetection and non-invasive blood analysis with emphasis on glucose detection. Instrumentation for Raman measurements is described. The sources of noise and interferences occurring in biological tissue measurements...
-
Tonality Estimation and Frequency Tracking of Modulated Tonal Components
PublikacjaA novel method for tonality estimation and frequency tracking of tonal components modulated in frequency and amplitude is presented. The algorithm detects the local maxima of magnitude spectra corresponding to three contiguous frames of a signal and matches them into the tonal track candidates. The magnitude-based and phase-based methods are used to estimate the frequency jumps between spectrum maxima belonging to the tonal track...
-
Implementation of constant component filter in measurements of random telegraph signal noise
PublikacjaNoise is generated in all semiconductor devices. The intensity of these fluctuations depends on used elements, manufacturing process, operating conditions and device type. The result noise is a superposition of different kinds of fluctuations like thermal noise, generation-recombination noise, 1/f noise, shot noise and Random Telegraph Signal (RTS) noise. The last one, RTS noise is observed as nonstationary impulse fluctuations....
-
Measurement of distance, velocity and angle of arrival using FMCW-CW combined waveform
PublikacjaA procedure of tacking small flying object based on a general principle of FMCW and Doppler radar is presented. In order to increase measurement range, this technique uses active signal source on the moving object. For simultaneous measurements of distance, radial velocity and direction (AoA) as well as simplified synchronization a combined FMCW-CW waveform is proposed. The presented measurement system was realized and verified...
-
Dynamic mass measurement in checkweighers using a discrete time-variant low-pass filter
PublikacjaConveyor belt type checkweighers are complex mechanical systems consisting of a weighing sensor (strain gauge load cell, electrodynamically compensated load cell), packages (of different shapes, made of different materials) and a transport system (motors, gears, rollers). Disturbances generated by the vibrating parts of such a system are reflected in the signal power spectra in a form of strong spectral peaks, located usually in...
-
Noise in biological Raman spectroscopy
PublikacjaRaman spectroscopy is a widely used method to investigate chemical molecules by analyzing their vibrational transitions. It utilizes inelastic scattering of the laser light irradiating the investigated object. The scattered light requires appropriate filtering to reduce dominant laser light and expose much weaker components having shifted wavelengths of a characteristic spectral pattern. These components are measured by dispersing...
-
Intelligent Autonomous Robot Supporting Small Pets in Domestic Environment
PublikacjaIn this contribution, we present preliminary results of the student project aimed at the development of an intelligent autonomous robot supporting small pets in a domestic environment. The main task of this robot is to protect a freely moving small pets against accidental stepping on them by home residents. For this purpose, we have developed the mobile robot which follows a pet and makes an alarm signal when a human is approaching....
-
Signal propagation in electromagnetic media described by fractional-order models
PublikacjaIn this paper, signal propagation is analysed in electromagnetic media described by fractional-order (FO) models (FOMs). Maxwell’s equations with FO constitutive relations are introduced in the time domain. Then, their phasor representation is derived for one-dimensional case of the plane wave propagation. With the use of the Fourier transformation, the algorithm for simulation of the non-monochromatic wave propagation is introduced....
-
Automatic sound source localization in disturbing conditions using acoustic vector sensors
PublikacjaA concept, practical realization and applications of a passive acoustic radar to automatic localization and tracking of sound sources in disturbing conditions were presented in the paper. The device consists of the new kind of multichannel miniature sound intensity sensors and a group of digital signal processing algorithms. The sensitivity of the realized acoustic radar was examined in free sound field. Several kinds of sound...
-
Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes
PublikacjaNon-invasive measurement methods offer great benefits in the field of medical diagnostics with molecular-specific techniques such as Raman spectroscopy which is increasingly being used for quantitative measurements of tissue biochemistry in vivo. However, some important challenges still remain for label-free optical spectroscopy to be incorporated into the clinical laboratory for routine testing. In particular, non-analyte-specific...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Dane BadawczeThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Dane BadawczeThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Comparison of two methods of sound extraction from guitar string video recordings
PublikacjaA comparison of two sound extraction methods from guitar string video recordings is presented in the paper. A brief overview of highframe rate camera technology and possible applications are included. The method using the image analysis from two such cameras is presented. The cameras are placed at the angle of 90 degrees for recording the image in three planes. The results achieved...
-
Compressive Sensing Approach to Harmonics Detection in the Ship Electrical Network
PublikacjaThe contribution of this paper is to show the opportunities for using the compressive sensing (CS) technique for detecting harmonics in a frequency sparse signal. The signal in a ship’s electrical network, polluted by harmonic distortions, can be modeled as a superposition of a small number of sinusoids and the discrete Fourier transform (DFT) basis forms its sparse domain. According to the theory of CS, a signal may be reconstructed...
-
XPS data of deuterium and hydrogen grown boron-doped diamond
Dane BadawczeThe high-resolution C1s X-ray absorption spectra of BDD@H and BDD@D samples were measured using the facilities of the HE-SGM beamline (HE-SGM) at the BESSY II synchrotron radiation source of Helmholtz–Zentrum Berlin (HZB).[90] The measurements were carried out under ultra-high vacuum conditions: P ≈ 2×10−9 Torr at T = 300 K. The NEXAFS spectra were...
-
Usage of the Gstreamer framework for generation, analysis, processing and visualization of sonar signal
PublikacjaIn this paper a novel method of the bearing estimation in a passive sonar system with a towed array is introduced. The classical approach of the bearing estimation based on the spatial spectrum is extended by using the synchrosqeezing method that is a part of the reassignment method introduced by Kodera et al. The usage of this method leads to the precise bearing estimation. The proposed method requires a relatively small amount...
-
THE SYNCHROSQUEEZING METHOD IN BEARING ESTIMATION OF STATIONARY SIGNALS FOR PASSIVE SONAR WITH TOWED ARRAY
PublikacjaIn this paper, a novel method of bearing estimation in a passive sonar system with a towed array is introduced. The classical approach of bearing estimation based on the spatial spectrum [1] is extended by using the synchrosqeezing method that is a part of the reassignment method introduced by Kodera et al. [2]. Using this method leads to a precise bearing estimation. The proposed method requires a relatively small amount of computation,...
-
The Mott-Schottky characteristics of microwave pulsed-plasma polymerized allylamine by DEIS analysis
Dane BadawczeThe dataset contains the results obtained for the Mott-Schottky analysis of the microwave pulsed-plasma polymerized allylamine using the multifrequency perturbation signal with Dynamic Electrochemical Impedance Spectroscopy (DEIS) technique. The results were obtained using the perturbation composed of the elementary signals with a frequency range between...
-
Optical Coherence Tomography for nanoparticles quantitative characterization
PublikacjaThe unique features of nanocomposite materials depend on the type and size of nanoparticles, as well as their placement in the composite matrices. Therefore the nanocomposites manufacturing process requires inline control over certain parameters of nanoparticles such as dispersion and concentration. Keeping track of nanoparticles parameters inside a matrix is currently a difficult task due to lack of a fast, reliable and cost effective...
-
Heart rate PPG signals with acceleration captured at wrist during small and moderate body movements
Dane BadawczeHeart rate PPG signals with acceleration captured at wrist during small and moderate body movements
-
Niobate in silicate and phosphate glasses: Effect of glass basicity on crucible dissolution
PublikacjaUsing niobium crucibles for melting phosphate and silicate glasses of various modifier oxide contents, and therefore varying optical basicity (Λ), was found to result in varying dissolution rates of niobate during melting. Because of their high electronic polarizability, even small concentrations of niobates are detectable in the Raman spectra of glasses. Even less than 1 mol% Nb2O5 can be identified, as independently confirmed...
-
Polarimetric studies of L-arginine-doped potassium dihydrogen phosphate single crystals
PublikacjaConoscopic interference patterns, channelled spectra and polarimetric techniques have been used for the characterization of pure and doped (with L-arginine amino acid) potassium dihydrogen phosphate (KDP) single crystals. Experimental polarimetric data have been obtained for the frequently used wavelength of 633 nm and for two close wavelengths of 532 and 543 nm in a high-accuracy dual-wavelength polarimeter. The measurement of...
-
Determination of Chemical Oxygen Demand (COD) at Boron-doped Diamond (BDD) Sensor by Means of Amperometric Technique
PublikacjaA boron-doped diamond (BDD) sensor was proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Thin boron doped diamond active sensor layer was deposited on Si wafer and glassy carbon substrate by Microwave Plasma Enhanced Chemical Vapor Deposition (MW PE CVD). The structure of BDD was confirmed by Raman spectra analysis. Broad Raman bands centered at 482 cm-1 and 1219 cm-1 are typical...
-
Determination of chemical oxygen demand (cod) at boron-doped diamond (bdd) sensor by means of amperometric technique
PublikacjaA boron-doped diamond (BDD) sensor was proposed for effective detection of chemical oxygen demand (COD) by means of amperometric technique. Thin boron doped diamond active sensor layer was deposited on Si wafer and glassy carbon substrate by Microwave Plasma Enhanced Chemical Vapor Deposition (MW PE CVD). The structure of BDD was confirmed by Raman spectra analysis. Broad Raman bands centered at 482 cm-1 and 1219 cm-1 are typical...
-
Model and laboratory simulation of a induction motor for diagnostic purposes
PublikacjaStatistics say that bearings are this part of induction motors which is most susceptible to damage. The equipment employed for bearing diagnostics usually makes use of vibrations as the criterion for technical condition of the bearings. A faulty bearing results in additional motor vibrations. They are reflected in the harmonic content of stator currents. In certain operating conditions the current signal is the sole source of information...
-
A Quasi-2D MOSFET Model — 2D-to-Quasi-2D Transformation
PublikacjaA quasi-two-dimensional (quasi-2D) representation of the MOSFET channel is proposed in this work. The representation lays the foundations for a quasi 2D MOSFET model. The quasi 2D model is a result of a 2D into quasi 2D transformation. The basis for the transformation are an analysis of a current density vector field and such phenomena as Gradual Channel Detachment Effect (GCDE), Channel Thickness Modulation Effect (CTME), and...
-
Acoustic radar employing particle velocity sensors
PublikacjaA concept, practical realization and applications of a passive acoustic radar to automatic localization, tracking of sound sources were presented in the paper. The device consist of the new kind of multichannel miniature sound intensity sensors and a group of digital signal processing algorithms. Contrary to active radars, it does not emit the scanning beam but after receiving surroundings sounds it provide information about the...
-
Electronic conductivity in the SiO2-PbO-Fe2O3 glass containing magnetic nanostructures
PublikacjaThe linear impedance spectra of iron–silicate–lead glass samples were measured in the frequency range from 1 MHz to 1 MHz and in the temperature range from 153 K to 423 K. The structure was investigated by means of XRD and atomic force microscopy. Local electrical and magnetic properties of the samples were tested with the aid of electrostatic force microscopy (EFM) and magnetic force microscopy (MFM). The obtained results show...
-
Nonlinear Impedance as Possible Result of Ion-Polaron Interaction in Cu2O-Al2O3-SiO2 Glass
PublikacjaNonlinear a.c. impedance measurements were performed in Cu2O-Al2O3-SiO2 glass in wide frequency range. The obtained results shows that a large nonlinearity in the impedance signal is observed at moderate electric fields of an order 1V/mm. The contents of the third harmonics reaches about 10% and strongly depends on temperature and frequency. The investigated glass exhibits mixed electronic-ionic conductivity. Electronic conduction...
-
Anatomy of noise in quantitative biological Raman spectroscopy
PublikacjaRaman spectroscopy is a fundamental form of molecular spectroscopy that is widely used to investigate structures and properties of molecules using their vibrational transitions. It relies on inelastic scattering of monochromatic laser light irradiating the specimen. After appropriate filtering the scattered light is dispersed onto a detector to determine the shift from the excitation wavelength, which appears in the form of...
-
Parallel multithread computing for spectroscopic analysis in optical coherence tomography
PublikacjaSpectroscopic Optical Coherence Tomography (SOCT) is an extension of Optical Coherence Tomography (OCT). It allows gathering spectroscopic information from individual scattering points inside the sample. It is based on time-frequency analysis of interferometric signals. Such analysis requires calculating hundreds of Fourier transforms while performing a single A-scan. Additionally, further processing of acquired spectroscopic information...
-
Electrical properties and structure of lead-borate glass containing iron ions.
PublikacjaThe ac and dc conductivity in iron–lead-borate glass samples was investigated in the frequency range from 1 mHz to 1 MHz and in the temperature range from 153 K to 423 K. The structure was investigated by the means of atomic force microscopy (AFM) and the crystalline phases (if present) were identified by the means of X-ray diffractometry. Two types of ac electrical behaviour were observed. The first group of glass samples which...
-
A nine-input 1.25 mW, 34 ns CMOS analog median filter for image processing in real time
PublikacjaIn this paper an analog voltage-mode median filter, which operates on a 3 × 3 kernel is presented. The filter is implemented in a 0.35 μm CMOS technology. The proposed solution is based on voltage comparators and a bubble sort configuration. As a result, a fast (34 ns) time response with low power consumption (1.25 mW for 3.3 V) is achieved. The key advantage of the configuration is relatively high accuracy of signal processing,...
-
Receiver of Doppler multistatic system for moving target detection and tracking
PublikacjaThe article presents a method for solving major structural problems that occur in the receiver used in the multistatic Doppler system, aimed at determination of the trajectory and velocity of a moving target. In the system two transmitters emit acoustic continuous sinusoidal waves at different frequencies. The signals, scattered from a moving target are received by four hydrophones. Beside of the echoes, much larger signals coming...
-
A Study on Audio Signal Processed by "Instant Mastering"
PublikacjaAn increasing amount of music produced in home- and project-studios results in development and growth of "automatic mastering services". The presented investigation explores changes introduced to audio signal by various online mastering platforms. A music set consisting of 10 songs produced in small facilities was processed by eight on-line automatic mastering services. Additionally, some laboratory-constructed signals were tested....
-
AFM-assisted investigation of conformal coatings in electronics
PublikacjaPurpose – This paper aims to presents a new method of investigation of local properties of conformal coatings utilized in microelectronics. Design/methodology/approach – It is based on atomic force microscopy (AFM) technique supplemented with the ability of local electrical measurements, which apart from topography acquisition allows recording of local impedance spectra, impedance imaging and dc current mapping. Potentialities...
-
Mechanical Properties of Bio-Composites Based on Epoxy Resin and Nanocellulose Fibres
PublikacjaThe aim of our research was to investigate the effect of a small nanocellulose (NC) addition on an improvement of the mechanical properties of epoxy composites. A procedure of chemical extraction from pressed lignin was used to obtain nanocellulose fibers. The presence of nanoparticles in the cellulose pulp was confirmed by FTIR/ATR spectra as well as measurement of nanocellulose particle size using a Zetasizer analyzer. Epoxy...
-
Signal Reconstruction from Sparse Measurements Using Compressive Sensing Technique
PublikacjaThe paper presents the possibility of applying a new class ofmathematical methods, known as Compressive Sensing (CS) for recovering thesignal from a small set of measured samples. CS allows the faithful recon-struction of the original signal back from fewer random measurements bymaking use of some non-linear reconstruction techniques. Since of all thesefeatures, CSfinds its applications especially in the areas where, sensing is...
-
Linear and nonlinear impedance of iron containing silicate glasses
Dane BadawczeThe linear and nonlinear impedance ofglasses doped with iron oxide were measured. Glass samples (50 SiO2-50-xPbO-xFe2O3 in mol%) were prepared by the conventional melt quenching technique. The substrates were powdered in a mortar and melted in Al2O3 crucibles. The melting was conducted in air at 1623K. The melts were poured out on plate heated up to...
-
Evaluation of organic coatings condition with AFM-based method
PublikacjaThe paper presents an atomic force microscopy (AFM)-based approach to evaluation of local protective properties of organic coatings. Apart from topography, it provides local ac and dc characteristics of examined coating. The method consists in application of ac voltage perturbation signal between conductive AFM tip and coated metal substrate. The resulting current is used to determine local impedance characteristics. Both impedance...
-
Structure and hyperfine interactions in Bi1−xNdxFeO3 solid solutions prepared by solid-state sintering
PublikacjaThe series of polycrystalline ceramic powders, Bi1xNdxFeO3 (x = 0.11) was successfully synthesized by mixed oxide method followed by pressureless sintering. X-ray diffraction and Mössbauer spectroscopy were used as complementary methods to study structure and hyperfine interactions of the samples. It was found that with an increase of Nd content, within the range of x = 0.20.3 a structural phase transition from rhombohedral to...
-
Examination of Spectral Properties of Medicinal Plant Leaves Grown in Different Lighting Conditions Based on Mint Cultivation
PublikacjaCultivation in controlled environmental conditions can provide good quality medicinal herbs with consistent properties. A sensing system that can determine the contents of medicinal substances in plants using spectral characteristics of leaves would be a valuable tool. Viability of such sensing approach for mint had to be confirmed experimentally, as no data correlating contents of medicinal substances with spectral characteristics...
-
Density functional LCAO calculations of vibrational modes and phonon density of states in the strained single-layer phosphorene
PublikacjaThe paper presents an investigation of phosphorene under axial strain on the phonon density of states and vibrational modes. The studies were performed by means of density functional theory (DFT) within the linear combination of atomic orbitals (LCAO). The strained models were constructed using optimised supercell techniques. The vibrational mode spectra were estimated for strains applied for both the zigzag and armchair directions...
-
Buried Object Characterization Using Ground Penetrating Radar Assisted by Data-Driven Surrogate-Models
PublikacjaThis work addresses artificial-intelligence-based buried object characterization using 3-D full-wave electromagnetic simulations of a ground penetrating radar (GPR). The task is to characterize cylindrical shape, perfectly electric conductor (PEC) object buried in various dispersive soil media, and in different positions. The main contributions of this work are (i) development of a fast and accurate data driven surrogate modeling...
-
Optical properties of thin TiO2 film deposited on the fiber optic sensor head
PublikacjaThe presented study was focused on investigation of the titanium dioxide (TiO2) thin film deposited on the fiber tip. The intention of this investigation was using TiO2 film in the construction of the optical fiber sensor head. In the demonstrated construction TiO2 thin layer was deposited on the tip of a commonly used telecommunication single mode optical fiber (SMF-28) by means of the Atomic Layer Deposition (ALD). Thickness...
-
Raman data of deuterium and hydrogen grown boron-doped diamond
Dane BadawczeRaman spectra were recorded at room temperature using a micro-Raman spectrometer (Invia, Renishaw) equipped with an edge filter with different excitation wavelengths and lasers: UV λ = 325 nm (HeCd), blue λ = 488 nm (Ar+), green λ = 514 nm (Ar+), and IR λ = 785 nm (IR diode) and 50× microscope objective. To avoid sample heating, the radiation power...
-
Half-Order Modeling of Saturated Synchronous Machine
PublikacjaNoninteger order systems are used to model diffusion in conductive parts of electrical machines as they lead to more compact and knowledge models but also to improve their precision. In this paper a linear half-order impedance model of a ferromagnetic sheet deduced from the diffusion of magnetic field is briefly introduced. Then, from physical considerations and finite elements simulation, the nonlinear half-order impedance model...
-
Visible light activity of pulsed layer deposited BiVO4/MnO2 films decorated with gold nanoparticles: The evidence for hydroxyl radicals formation
PublikacjaThin films containing BiVO4 and MnO2 deposited on FTO and modified by Au nanoparticles were studied towards their photoelectrochemical and photocatalytical activities in an aqueous electrolyte. Electrodes were prepared by the pulsed laser deposition (PLD) method. The surfactant-free ablation process was used for preparation of the gold nanoparticles (GNP) water suspension. Obtained layers of varied thicknesses (27–115 nm) were...
-
Effect of osmolytes of different type on DNA behavior in aqueous solution. Experimental and theoretical studies
PublikacjaOsmolytes, the small organic molecules accumulated in cells under environmental stress, can modulate the stability of biopolymers such as proteins and DNA. In spite of many years of research, there is no established molecular mechanism of the influence of osmolytes on DNA structure. Here, we used two model osmolytes that denature (urea) or stabilize (trimethylglycine, TMG) proteins to study their effect on DNA in aqueous solutions...
-
The Weibull model of the multipath fading channel
Dane BadawczeThe dataset contains the results of simulations that are part of the research on modelling the multipath fading in the communication channel. The Weibull fading envelope is generated using the Monte-Carlo simulation (MCS) in the LabVIEW programming environment.
-
A CMOS Pixel With Embedded ADC, Digital CDS and Gain Correction Capability for Massively Parallel Imaging Array
PublikacjaIn the paper, a CMOS pixel has been proposed for imaging arrays with massively parallel image acquisition and simultaneous compensation of dark signal nonuniformity (DSNU) as well as photoresponse nonuniformity (PRNU). In our solution the pixel contains all necessary functional blocks: a photosensor and an analog-to-digital converter (ADC) with built-in correlated double sampling (CDS) integrated together. It is implemented in...
-
A High-Efficient Measurement System With Optimization Feature for Prototype CMOS Image Sensors
PublikacjaIn this paper, a gray-scale CMOS image sensor (CIS) characterization system with an optimization feature has been proposed. By using a very fast and precise control of light intensity, based on the pulsewidth-modulation method, it is avoided to measure the illuminance every time. These features accelerate the multicriteria CIS optimization requiring many thousands of measurements. The system throughput is 2.5 Gb/s, which allows...
-
Low-Power Receivers for Wireless Capacitive Coupling Transmission in 3-D-Integrated Massively Parallel CMOS Imager
PublikacjaThe paper presents pixel receivers for massively parallel transmission of video signal between capacitive coupled integrated circuits (ICs). The receivers meet the key requirements for massively parallel transmission, namely low-power consumption below a single μW, small area of less than 205 μm2, high sensitivity better than 160 mV, and good immunity to crosstalk. The receivers were implemented and measured in a 3-D IC (two face-to-face...
-
Feasibility study of a Raman spectroscopic route to drug detection
PublikacjaWe present an surface-enhanced Raman spectroscopy (SERS) approach for detection of drugs of abuse in whole human blood. We utilize a near infrared laser with 830 nm excitation wavelength in order to reduce the influence of fluorescence on the spectra of blood. However, regular plasmon resonance peak of plasmonic nanoparticles, such as silver or gold fall in a much lower wavelength regime about 400 nm. Therefore, we have shifted...
-
Cross-talk Between the Heart and Arteries in Older 65+ Adults
PublikacjaRegulatory synchronization between the heart and the arterial walls is essential for optimal blood delivery to tissues. We investigated functional coherence between heart rhythm and aortic wall compliance in 30 volunteers aged 65 – 74. ECG and carotid and iliac pulse-wave were recorded and digitized at 2 kHz. Carotid-femoral pulse-wave transit time (cfTT) which reflex aortic compliance was assessed using the intersecting tangent...
-
Linear and nonlinear impedance of alkali and iron doped silicate-lead glasses
Dane BadawczeLinear and nonlinear impedance was studied for lead-silicate glass samples doped with iron ions and alkaline oxides. The compositions of glasses were as follows: (in %mol) 50% SiO2, 25% PbO, 15% Fe2O3 and 15% one of alkaline oxides: Na2O, K2O, Li2O. All samples were prepared by the conventional melt quenching technique. The substrates were powdered...
-
Detection of Delamination in Laminate Wind Turbine Blades Using One-Dimensional Wavelet Analysis of Modal Responses
PublikacjaThis paper demonstrates the effectiveness of a nondestructive diagnostic technique used to determine the location and size of delamination in laminated coatings of wind turbine blades. This is realized based on results of numerical and experimental investigations obtained by the use of the finite element method (FEM) and laser scanning vibrometry (LSV). The proposed method is based on the one-dimensional continuous wavelet transform...
-
Methods of data extraction from sub-bottom profiler's signal
PublikacjaData obtain during sounding Gdansk Bay with SES-2000 Standard parametric sub-bottom profiler has two types of information: envelope and pure signal. First is used to plot echograms in real time and contain envelope of echo. The second one is stored during sounding and can be processed after recording data. Comparison of results will be shown and discussed. First step in investigation was proper configuration of small measurement...
-
Morski skaning laserowy infrastruktury portowej na przykładzie portu we Władysławowie
PublikacjaTechnologia skaningu laserowego rozwinęła się współcześnie do etapu, w którym skaning mobilny jest swobodnie wykorzystywany na platformach pojazdów drogowych i szynowych oraz statków powietrznych. Do szczególnych rozwiązań skaningu mobilnego zalicza się skaning morski. Użycie tego rozwiązania stanowi nowe rozwiązanie dla problematyki inwentaryzacji infrastruktury portowej w sytuacji dużego ruchu morskiego lub rozległych basenów...
-
Comparative X-ray diffraction and Mössbauer spectroscopy studies of BiFeO3 ceramics prepared by conventional solid-state reaction and mechanical activation
PublikacjaThe aim of this work was to prepare BiFeO3 by modified solid-state sintering and mechanical activation processes and to investigate the structure and hyperfine interactions of the material. X-ray diffraction and Mössbauer spectroscopy were applied as complementary methods. In the case of sintering, BiFeO3 phase was obtained from the mixture of precursors with 3 and 5 % excess of Bi2O3 during heating at 1023 K. Small amounts of...
-
Iterative learning approach to active noise control of highly autocorrelated signals with applications to machinery noise
PublikacjaThis paper discusses the design and application of iterative learning control (ILC) and repetitive control (RC) for high modal density systems. Typical examples of these systems are structural and acoustical systems considered in active structural acoustic control (ASAC) and active noise control (ANC) applications. The application of traditional ILC and RC design techniques, which are based on a parametric system model, on systems...
-
Localization of impulsive disturbances in audio signals using template matching
PublikacjaIn this paper, a new solution to the problem of elimination of impulsive disturbances from audio signals, based on the matched filtering technique, is proposed. The new approach stems from the observation that a large proportion of noise pulses corrupting audio recordings have highly repetitive shapes that match several typical “patterns”. In many cases a representative set of exemplary pulse waveforms can be extracted from the...
-
Reception of Terrestrial DAB+ and FM Radio with a Mobile Device: A Subjective Quality Evaluation
PublikacjaNowadays, terrestrial broadcasting enables to receive content anytime and everywhere. People can obtain information both with a portable or desktop receiver, which include pocket-sized devices as well as high-end Hi-Fi equipment, not to mention car audio systems. Numerous manufacturers include FM-compatible chipsets in a variety of user equipment (UE), including mobile phones. However, digital radio signal processing modules, such...
-
Diamond-based protective layer for optical biosensors
PublikacjaOptical biosensors have become a powerful alternative to the conventional ways of measurement owing to their great properties, such as high sensitivity, high dynamic range, cost effectiveness and small size. Choice of an optical biosensor's materials is an important factor and impacts the quality of the obtained spectra. Examined biological objects are placed on a cover layer which may react with samples in a chemical, biological...