Filters
total: 1118
filtered: 1044
displaying 1000 best results Help
Search results for: PHASE ANALYSIS
-
In-situ odd random phase electrochemical impedance spectroscopy study on the electropolymerization of pyrrole on iron in the presence of sodium salicylate – The influence of the monomer concentration
PublicationIn this work, the potentiostatic electropolymerization of polypyrrole (PPy) on iron in aqueous solution of sodium salicylate and pyrrole is studied in situ by odd random phase electrochemical impedance spectroscopy (ORP-EIS). The influence of the pyrrole concentration on the electrosynthesis process is investigated. The ORP-EIS technique ensures a reliable analysis of the PPy electrosynthesis on iron by means of an advanced data...
-
A Comparative Study of Fuzzy SMC with Adaptive Fuzzy PID for Sensorless Speed Control of Six-Phase Induction Motor
PublicationMulti-phase motors have recently replaced three-phase induction motors in a variety of applications due to the numerous benefits they provide, and the absence of speed sensors promotes induction motors with variable speed drives. Sensorless speed control minimizes unnecessary speed encoder cost, reduces maintenance, and improves the motor drive’s reliability. The performance comparison of the fuzzy sliding mode controller (FSMC)...
-
A Comparative Study of Fuzzy SMC with Adaptive Fuzzy PID for Sensorless Speed Control of Six-Phase Induction Motor
PublicationMulti-phase motors have recently replaced three-phase induction motors in a variety of applications due to the numerous benefits they provide, and the absence of speed sensors promotes induction motors with variable speed drives. Sensorless speed control minimizes unnecessary speed encoder cost, reduces maintenance, and improves the motor drive’s reliability. The performance comparison of the fuzzy sliding mode controller (FSMC)...
-
Effect of isovalent substitution on microstructure and phase transition of LaNb1−xMxO4 (M=Sb, V or Ta; x=0.05–0.3)
PublicationLaNb1−xMxO4 oxides with pentavalent elements of different ionic sizes (M=Sb, Ta and V, x=0.05–0.3) were synthesized by the solid state reaction method. Special interest was devoted to the antimony substituted lanthanum niobate which is a new material in this group. Rietveld analysis of the X-ray diffraction patterns was used to determine the influence of the material composition on unit cell parameters. On the basis of dilatometric...
-
Determination of antifreeze substances in the airport runoff waters by solid-phase microextraction and gas chromatography–mass spectrometry method
PublicationA new method has been developed for the determination of antifreeze agents such as ethylene glycol (EG), propylene glycol (PG), and diethylene glycol (DEG) in the samples of airport runoff water. The method is based on headspace solid–phase microextraction (HS–SPME) of target analytes, which is coupled with gas chromatography–mass spectrometry (GC–MS). Until now, there was a lack of appropriate methodology for collecting reliable...
-
Tuning the extraction properties of ionogel-coated Solid-phase microextraction fibers based on the solvation properties of the ionic liquids
PublicationA silica-based network was used to immobilize ionic liquid-based ionogels and applied as a fiber coating forsolid-phase microextraction (SPME). The ionogels were prepared by a sol–gel process, using two ionic liquids,triethylsulfonium bis(trifluoromethylsulfonyl)imide ([Set3][TFSI]) and 1-butyl-1-methylpiperidinium bis(tri-fluoromethylsulfonyl)imide ([C4C1Pip][TFSI]), as well as their equimolar mixture. Methyltrimethoxysilane wasused...
-
Polymeric metal‐containing ionic liquid sorbent coating for the determination of amines using headspace solid‐phase microextraction
PublicationThis study describes the design, synthesis, and application of polymeric ionic liquid sorbent coatings featuring nickel metal centers for the determination of volatile and semivolatile amines from water samples using headspace solidphase microextraction. The examined polymeric ionic liquid sorbent coatings were composed of two ionic liquid monomers (tetra(3-vinylimidazolium)nickel bis[(trifluoromethyl)sulfonyl]imide [Ni2+(VIM)4]...
-
Determination of Butyltin Species in Sea Water Samples Using Solid Phase Extraction Followed by Liquid Chromatography - Tandem Mass Spectrometry
PublicationReverse phase liquid chromatography (RP-HPLC)-electrospray ionization-tandem mass spectrometry (ESI-MS-MS) was evaluated for the analysis of TBT using solid phase extraction as sample preparation method. TBT was extracted from acidified water samples (spiked with tripropyltin as internal standard) using reversed phase polymeric Strata-X cartridges. Analytes were eluted from cartridges using acetonitrile-water mixture and the volume...
-
Application of response surface methodology to optimize solid-phase microextraction procedure for chromatographic determination of aroma-active monoterpenes in berries
PublicationMost of scientific papers concern the qualitative or semi-quantitative analysis of aroma-active terpenes in liquid food matrices. Therefore, the procedure based on solid-phase microextraction and comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry for determination of monoterpenes in fresh berries was developed. The optimal extraction conditions using divinylbenzene-carboxen-polydimethylsiloxane fiber...
-
Experimental and comparative study on the two-phase pressure drop of air-water mixture in U-bend and straight pipe annuli
PublicationIn this paper, the experimental and theoretical analysis of pressure drop in singlephase and two phase-flow were presented for straight and U-bend smooth tube annulus and tube annulus with wire coil insert. Experiments for various boundary conditions were performed. In case of U-tube and straight tube with and without turbulator, tests were made for the water-water and air-water systems. The study covered a wide measuring range,...
-
Application of reversed-phase thin layer chromatography and QSRR modelling for prediction of protein binding of selected β-blockers
Publication -
Monitoring the gas turbine start-up phase on the platform using a hierarchical model based on Multi-Layer Perceptron networks
PublicationVery often, the operation of diagnostic systems is related to the evaluation of process functionality, where the diagnostics is carried out using reference models prepared on the basis of the process description in the nominal state. The main goal of the work is to develop a hierarchical gas turbine reference model for the estimation of start-up parameters based on multi-layer perceptron neural networks. A functional decomposition...
-
Precise Point Positioning Method Based on Wide-lane and Narrow-lane Phase Observations and Between Satellites Single Differencing
PublicationThe issue of using PPP method in position determination was formed in 1997. In most developed methods, ionospheric-free linear combination is used in order to eliminate the impact of the ionospheric delay. However, this approach does not provide the directly determination of the total value of the ambiguities, and the ambiguities for the individual signals. Therefore, in many publications methods of avoiding these deficiencies...
-
Large deformation finite element analysis of undrained pile installation
PublicationIn this paper, a numerical undrained analysis of pile jacking into the subsoil using Abaqus software suit has been presented. Two different approaches, including traditional Finite Element Method (FEM) and Arbitrary Lagrangian–Eulerian (ALE) formulation, were tested. In the first method, the soil was modelled as a two-phase medium and effective stress analysis was performed. In the second one (ALE), a single-phase medium was assumed...
-
Single-phase product obtained via crude glycerine depolymerisation of polyurethane elastomer: structure characterisation and rheological behaviour
PublicationPolyurethane recycling is a topic of growing interest due to the increasing amount of polyurethanewaste. The main purpose of polyurethane feedstock recycling is to recover the starting polyol, a valuable material. In thiswork, amethod of polyurethane thermo-chemical recycling, glycerolysisbymeansof crude glycerine, is proposed. Themaineffort is focusedonthe employment of crude glycerine without purification from biodiesel production...
-
Effective Permeability of Multi Air Gap Ferrite Core 3-Phase Medium Frequency Transformer in Isolated DC-DC Converters
PublicationThe magnetizing inductance of the medium frequency transformer (MFT) impacts the performance of the isolated dc-dc power converters. The ferrite material is considered for high power transformers but it requires an assembly of type “I” cores resulting in a multi air gap structure of the magnetic core. The authors claim that the multiple air gaps are randomly distributed and that the average air gap length is unpredictable at the...
-
Comparison of Headspace Solid-phase Microextraction, Headspace Single-drop Microextraction and Hydrodistillation for Chemical Screening of Volatiles in Myrtus Communis L
Publication -
Ionogel sorbent coatings for determining organophosphorus and pyrethroid insecticides in water and fresh juice samples by headspace-solid phase microextraction
PublicationThe sol–gel method yielded three different ionogel sorbent coatings that were obtained based on a silica material containing ionic liquids (ILs) immobilized in its pores. Two ILs, triethylsulfonium bis(trifluoromethylsulfonyl) imide [Set3][TFSI] and 1-butyl-1-methylpiperidinium bis(trifluoromethylsulfonyl)imide [C4C1Pip][TFSI], as well as their equimolar mixture [Set3/C4C1Pip], were used to obtain ionogel fibers. The developed...
-
Various types of semiconductor photocatalysts modified by CdTe QDs and Pt NPs for toluene photooxidation in the gas phase under visible light
PublicationA novel synthesis process was used to prepare TiO2 microspheres, TiO2 P-25, SrTiO3 and KTaO3 decorated by CdTe QDs and/or Pt NPs. The effect of semiconductor matrix, presence of CdTe QDs and/or Pt NPs on the semiconductor surface as well as deposition technique of Pt NPs (photodeposition or radiolysis) on the photocatalytic activity were investigated. The as-prepared samples were characterized by X-ray powder diffractometry (XRD),...
-
Rapid Characterization of the Human Breast Milk Lipidome Using a Solid-Phase Microextraction and Liquid Chromatography-Mass Spectrometry-Based Approach.
PublicationHuman breast milk (HBM) is a biofluid consisting of various biomolecules such as proteins, lipids, carbohydrates, minerals and bioactive substances. Due to its unique and complex composition, HBM provides not only nutritional components required for the growth of the infant, but also additional protection against infections. Global insight into the composition of HBM is crucial to understanding the health benefits infants receive...
-
Simultaneous Determination of Indolic Compounds in Plant Extracts by Solid-Phase Extraction and High-Performance Liquid Chromatography with UV and Fluorescence Detection
PublicationA high-performance liquid chromatographic method with UV and fluorescence detection (HPLC-DAD-FLD) was developed for simultaneous determination of indolic compounds in plant material. Indole-3-carbinol (I3C), indole-3-acetic acid (I3AA), indole-3-acetonitrile (I3ACN), and 3,3′-diindolylmethane (DIM) were used as representative compounds that cover a wide spectrum of indole structures occurring in nature. For concentration and purification...
-
Ionogel fibres of bis(trifluoromethanesulfonyl)imide anion-based ionic liquids for the headspace solid-phase microextraction of chlorinated organic pollutants
PublicationIonogels, a family of hybrid materials in which ionic liquids (ILs) are confined in a sol–gel network, are receiving much attention in a variety of scientific and technological fields. In this work, ionogels derived from three different ILs based on the anion bis(trifluoromethanesulfonyl)imide (TFSI), namely 1-butyl- 3-methylpyridinium bis(trifluoromethanesulfonyl)imide ([C4C1Py][TFSI]), 1-butyl-1-methylpyrrolidinium bis(trifluoromethanesulfonyl)imide...
-
Chromium‑based metal organic framework for pipette tip micro‑solid phase extraction: an effective approach for determination of methyl and propyl parabens in wastewater and shampoo samples
PublicationAbstract Background A chromium-based metal organic framework was synthesized and employed as an efficient sorbent for pipette tip micro-solid phase extraction and preconcentration of parabens from wastewater and shampoo samples up to sub-ppb level before their spectrophotometric analysis. Results Factors affecting preconcentration including volume and type of solvent, amount of sorbent, number of extraction, and volume and pH of...
-
Optimization of vortex-assisted hydrophobic magnetic deep eutectic solvent-based dispersive liquid phase microextraction for quantification of niclosamide in real samples
PublicationIn this manuscript, a green and fast vortex-assisted hydrophobic magnetic deep eutectic solvent-based dispersive liquid phase microextraction (VA-HMDES-DLPME) method was developed for the selective extraction and determination of niclosamide in read samples, including rice, medicine tablets, and water samples. Here, hydrophobic magnetic deep eutectic solvents were used as the extracting solvent without requiring any centrifugation...
-
Induction of G2/M phase arrest and apoptosis of human pancreatic cancer BxPC-3 cells by potenet antitumor 1-nitroacridine derivative C-1748
PublicationPancreatic ductal adenocarcinoma (PDA) is among the most lethal human cancers, in part because it is insensitive to many chemotherapeutic drugs. Gemcitabine still remains the best chemotherapeutic agent available for the treatment of advanced pancreatic cancer. However, gemcitabine treatment results in only a marginal survival advantage. Thus, there is a strong need for the continuous development of novel therapeutic agents...
-
An air-assisted dispersive liquid phase microextraction method based on a hydrophobic magnetic deep eutectic solvent for the extraction and preconcentration of melamine from milk and milk-based products
PublicationIn the current research, a fast and sustainable air-assisted hydrophobic magnetic deep eutectic solvent-based dispersive liquid phase microextraction followed by UV–Vis spectrophotometry measurements was optimized for the extraction and determination of melamine in milk and milk-based products. The central composite design was applied for the optimization of factors affecting the recovery of melamine. Quantitative extraction of...
-
Solid phase microextraction–comprehensive twodimensional gas chromatography–time-of-flight mass spectrometry: a new tool for determining PAHs in airport runoff water samples
Publicationfundamental aspect of airport operations is the pollution caused by airport runoff waters. Polycyclic aromatic hydrocarbons (PAHs) are one of the most important groups of xenobiotics which are commonly found in runoff water originating from airports. Only very limited data on the analysis of airport runoff water have been published until now. Therefore, a reliable and accurate analytical method based on headspace solid-phase microextraction...
-
Rapid and Green Separation of Mono- and Diesters of Monochloropropanediols by Ultrahigh Performance Supercritical Fluid Chromatography–Mass Spectrometry Using Neat Carbon Dioxide as a Mobile Phase
PublicationThis study demonstrates the effect of column selectivity and density of supercritical carbon dioxide (SC-CO2) on the separation of monochloropropanediol (MCPD) esters, known as food toxicants, using SC-CO2 without addition of cosolvent in ultrahigh performance supercritical fluid chromatography–mass spectrometry (UHPSFC-MS). This study shows that over 20 2-monochloropropanediol (2-MCPD) and 3-monochloropropanediol (3-MCPD) mono-...
-
Modal analysis of cylindrical steel tanks
PublicationCylindrical steel tanks are very popular structures used for storage of products of chemical and petroleum industries. Their safety and reliability is crucial because any failure could have serious consequences. The aim of present paper is to show the results of the first phase of investigation of seismic behaviour such structures. Modal analysis using Finite Element Method (FEM) for three models of real tanks used in Poland has...
-
On continuity conditions at the phase interface of two-phase elastic shells
PublicationW pracy rozwinięto ogólną nieliniową teorię powłok sprężystych podlegających przejściom fazowym typu martenzytowego. Przedstawione sformułowanie oparte jest na statycznie i kinematycznie ścisłym modelu powłokowym. Uwzględniono gęstośc energii odkształcenia, jak również siły i momenty zadane wzdłuż krzywoliniowego przejścia fazowego. W szczególności otrzymano statyczne warunki ciągłości wzdłuż koherentnego połączenia oraz połączenia...
-
Application and optimization of headspace solid-phase microextraction (HS-SPME) coupled with gas chromatography - flame-ionization detector (GC-FID) to determine products of the petroleum industry in aqueous samples
PublicationA simple and solvent-free analytical method has been optimized for the determination of hydrocarbons (C6 - C20) from products of the petroleum industry in aqueous samples. Extraction and analysis was carried out using headspace solid-phase microextraction (HS-SPME) and gas chromatography coupled with flame-ionization detector (GC-FID). A ZB-5 capillary column (30 m × 0.25 mm inner diameter, 0.25 µm film thickness) was used for...
-
Modelling and analysis of medium frequency transformers for power converters
PublicationThe evolutions in power systems and electric vehicles, related to the economic opportunities and the environmental issues, bring the need of high power galvanically isolated DC-DC converter. The medium frequency transformer (MFT) is one of its key components, enabled by the increasing switching frequency of modern power semiconductors like silicon carbide transistors or diodes. The increased operating frequency offers small...
-
Analysis and interpretation of radiometric signals in a liquid-gas bubble flow
PublicationThe article presents the analysis of signals from a radiometric system consisting of two scintillation probes and two gamma radiation sealed sources. Calculations and interpretation were carried out for the bubble flow of the water-air mixture in the horizontal pipeline. The analysis of the obtained signals was done in time and frequency domain. In the frequency domain, a range of usable frequencies was identified, which were associated...
-
Sputtered silicon solid phase microextraction fibers with a polydimethylsiloxane stationary phase with negligible carry-over and phase bleed
Publication -
Multicriteria decision analysis in ranking of analytical procedures for aldrin determination in water
PublicationThe study presents the possibility of multi-criteria decision analysis (MCDA) application when choosing analytical procedures with low environmental impact. A type of MCDA, Preference Ranking Organization Method for Enrichment Evaluations (PROMETHEE), was chosen as versatile tool that meets all the analytical chemists – decision makers requirements. Twenty five analytical procedures for aldrin determination in water samples (as...
-
Earth wires currents calculation by tableau analysis
PublicationThe paper presents a new method to compute a phase-to-earth fault current distribution in overhead transmission line. The method is based on the tableau analysis of an unbalanced, multi-wire model of a transmission line. It allows for the calculation of current distribution in overhead earth wires along the transmission line. Additionally, it may be used to calculate currents in a tower’s earthing system as well as voltages over...
-
Analysis of radiometric signal in sedimentating suspension flow in open channel
PublicationThe article discusses issues related to the estimation of the sedimentating solid particles average flow velocity in an open channel using radiometric methods. Due to the composition of the compound, which formed water and diatomite, received data have a very weak signal to noise ratio. In the process analysis the known determining of the solid phase transportation time delay the classical cross-correlation function is the most...
-
Ultrasound assisted dispersive solid phase microextraction using polystyrene-polyoleic acid graft copolymer for determination of Sb(III) in various bottled beverages by HGAAS
PublicationA new polyoleic acid-polystyrene (PoleS) block/graft copolymer was synthesized and applied as adsorbent for ultrasound assisted dispersive solid phase microextraction (UA-DSPME) of Sb(III) in different bottled beverages and analysis using hydride generation atomic absorption spectrometry (HGAAS). Adsorption capacity of the PoleS was 150 mg g−1. Several sample preparation parameters such as sorbent amount, solvent type, pH, sample...
-
Blowing Kinetics, Pressure Resistance, Thermal Stability, and Relaxation of the Amorphous Phase of the PET Container in the SBM Process with Hot and Cold Mold. Part I: Research Methodology and Results
PublicationThe technology of filling drinks without preservatives (such as fresh juices, iced tea drinks, vitaminized drinks) is carried out using hot filling. Mainly due to the production costs and lower carbon footprint, polyethylene terephthalate bottles, commonly called PET, are increasingly used in this technology. In this paper, the main aim is to describe the statistical analysis methodology of the influence of the temperature of the...
-
SPECTRAL DYNAMIC ANALYSIS OF A STATIONARY JACK-UP PLATFORM
PublicationThe paper refers to the dynamic short-term response analysis of the Baltic steel drilling platform (see Fig.2) in a random sea-state represented by one-dimensional wave spectrum proposed by Striekalov and Massel and it is recommended for the Baltic Sea area. The Baltic drilling platform is a jack-up type platform for the exploration and exploitation of oil under the Baltic Sea. The analysis presented deals with the stationary...
-
Modal analysis of railway current collectors using Autodesk Inventor
PublicationThe paper presents the results of modal analysis of railway current collector type 160EC. In the first place, the analysis was carried out analytically for a simplified two lumped mass pantograph model. Then numerical analysis was conducted in the Autodesk Inventor (AI) on the prepared multibody model using the AI modal analysis algorithm, which is based on the finite element method (FEM). Model elements which are most relevant...
-
Analysis of wave propagation in a bolted steel joint
PublicationThe paper presents results of numerical and experimental investigations of elastic wave propagation in a bolted single-lap joint. The research was carried out for both symmetric and antisymmetric Lamb wave modes. In experimental studies the PZT transducers were used to excite and register wave propagation signals. The controlled value of the torque during measurements was ensured by the use of high precision torque wrenches. Numerical...
-
Investigation of use of hydrophilic/hydrophobic NADESs for selective extraction of As(III) and Sb(III) ions in vegetable samples: Air assisted liquid phase microextraction and chemometric optimization
PublicationIn this paper, a green, cost-effective sample preparation method based on air assisted liquid phase microextraction (AA-LPME) was developed for the simultaneous extraction of As(III) and Sb(III) ions from vegetable samples using hydrophilic/hydrophobic natural deep eutectic solvents (NADESs). Central composite design was used for the optimization of extraction factors including NADES volume, extraction cycle, pH, and curcumin concentration....
-
Gas‐Phase Removal of Indoor Volatile Organic Compounds and Airborne Microorganisms Over Mono‐ and Bimetal‐Modified (Pt, Cu, Ag) Titanium(IV) Oxide Nanocomposites
PublicationThe photocatalytic deactivation of volatile organic compounds and mold fungi using TiO2 modified with mono‐ and bimetallic (Pt, Cu, Ag) particles is reported in this study. The mono‐ and bimetal‐modified (Pt, Cu, Ag) titanium(IV) oxide photocatalysts were prepared by chemical reduction method and characterized using XRD, XPS, DR/UV‐Vis, BET and TEM analysis. The effect of incident light, type and content of mono‐ and bimetallic...
-
Drug affinity to human serum albumin prediction by retention of cetyltrimethylammonium bromide pseudostationary phase in micellar electrokinetic chromatography and chemically advanced template search descriptors
Publication -
Two-phase flow in heterogeneous porous media with non-wetting phase trapping
PublicationThis article presents amathematical model describing flowof two fluid phases in a heterogeneous porous medium. Zaproponowano model matematyczny przepływu dwufazowego w drobnoziarnistym ośrodku porowatym zawierającym inkluzje gruboziarniste. Inkluzje charakteryzują się niższą wartością ciśnienia wejścia dla płynu niezwilżającego (np. powietrze, ropa naftowa) niż materiał podstawowy. Podczas nawadniania takiego ośrodka dochodzi do...
-
Five-phase Induction Motor Drive Operation During Stator Phase Fault
PublicationThe article presents the most important advantages of multi-phase electric drives. The construction of a five-phase squirrel cage induction motor together with possible stator winding distribution cases is presented, which affect the properties of such motor. Increased reliability of five-phase drives was indicated. The drive operation properties were confirmed by experimental results.
-
Development of a vortex-assisted switchable-hydrophilicity solvent-based liquid phase microextraction for fast and reliable extraction of Zn (II), Fe (II), Pb (II), and Cd (II) from various baby food products
PublicationThis manuscript describes the development of a novel liquid phase microextraction (LPME) method for the extraction and determination of Zn (II), Fe (II), Pb (II), and Cd (II) in various infant/baby food and supplements products. The method is based on vortex-assisted extraction combined with a switchable-hydrophilicity solvent (SHS) sample preparation. The SHS, which undergoes reversible phase changes triggered by pH change, enables...
-
Comparison of hydrophilic interaction and reversed phase liquid chromatography coupled with tandem mass spectrometry for the determination of eight artificial sweeteners and common steviol glycosides in popular beverages
PublicationHydrophilic interaction liquid chromatography (HILIC) coupled with tandem mass spectrometry (MS/MS) was used to separate artificial and natural sweeteners approved for use in European Union (EU). Among three tested HILIC columns (BlueOrchid PAL-HILIC, Ascentis Express Si and Acclaim™ Trinity™ P2) the last one was selected for the development of HILIC method due to the best results obtained with it. Early eluting and coeluting compounds...
-
Polyfunctional chemically bonded stationary phase for reversed phase high-performance liquid chromatography
Publication