A Development of a Capacitive Voltage Divider for High Voltage Measurement as Part of a Combined Current and Voltage Sensor
PublicationThis article deals with the development of capacitive voltage divider for high voltage measurements and presents a method of analysis and optimization of its parameters. This divider is a part of a combined voltage and current sensor for measurements in high voltage power networks. The sensor allows continuous monitoring of the network distribution status and performs a quick diagnosis and location of possible network failures....
-
Voltage Harmonic Distortion Measurement Issue in Smart-Grid Distribution System
PublicationThis paper presents the investigation results ofvoltage harmonic transfer accuracy problems through voltagetransformers which are widely used in power quality monitoringsystems in medium and high voltage grids. A simplified lumpedparameters circuit model of the voltage transformer is presentedand verified by simulation and experimental investigations. Anumber voltage transformers typically used in medium voltagegrid has been tested...
-
Fault loop impedance measurement in low voltage network with residual current devices
PublicationW sieciach i instalacjach niskiego napięcia z wyłącznikami różnicowoprądowymi pomiar impedancji pętli zwarciowej jest kłopotliwy. Prąd pomiarowy powoduje ich zbędne zadziałanie, co uniemożliwia prawidłowe wykonanie pomiaru. W artykule omówiono przyczyny zbędnego zadziałania wyłączników różnicowoprądowych podczas pomiaru impedancji pętli zwarciowej oraz warunki, w jakich ten pomiar można wykonać poprawnie.
-
Measurement of the earth fault loop impedance in a low voltage network with operating loads
PublicationW artykule przedstawiono problematykę dokładności pomiaru impedancji pętli zwarciowej w sieciach z obciążeniami roboczymi. Klasyczne metody pomiarowe i mierniki mogą powodować błędy pomiaru przekraczające dopuszczalną wartość. Z tego powodu może wystąpić ryzyko porażenia prądem elektrycznym, ponieważ przy doziemieniu nie będzie spełniony warunek samoczynnego wyłączenia zasilania. Błędy pomiaru w sieci z obciążeniami roboczymi można...
-
Frequency measurement research with weight averaging of pulse output signal of voltage-to-frequency converter
PublicationThe paper presents the essence and investigation of the efficiency of weight averaging of a pulse output signal of voltage-to-frequency converter. The effect of counting and the influence of interference on the result of weight averaging of frequency modulated pulses are analyzed. It is shown that from the point of view of counting error reduction, the best are polynomial weight functions. In the case of high interferences whose...
-
Electrochemical sensor for measurement of volatile organic compounds employing square wave perturbation voltage
PublicationThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde in air. Sensitivity and limit of quantification of the sensor were determined for different internal electrolyte using the square wave voltammetry (SWV) as a detection technique. The working and counter electrodes were made of platinum. Ionic liquids 1-hexyl, 3-methylimidazolium chloride,1-hexyl, 3-methylimidazolium bis (trifluoromethanesulfonyl)...
-
A new method of fault loop resistance measurement in low voltage systems with residual current devices
PublicationThis paper presents a new method of fault loop resistance measurement in low voltage systems with residual current devices. The method enables measuring fault loop resistance without nuisance tripping of residual current devices, by application an unconventional waveform of measurement current. It is important for proper verification of the effectiveness of protection against electric shock.
-
Magnetic and capacitive couplings influence on power and energy measurement in double circuit high voltage overhead transmission line
PublicationThe paper discusses influence of magnetic and capacitive couplings on power and energy measurement in case of double circuit high voltage overhead transmission line. There are presented and discussed various factors influencing the power flow among the line‟s circuits. Mathematical model based calculations results are compared to the real transmission line measurements.
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublicationVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
The voltage across and current through the RC model object tested using pulse excitation in impedance spectroscopy measurement method
Open Research DataThe raw data (voltage across and current through RC model object ) obtained using pulse excitation EIS impedance spectroscopy measurement method. The data was acquired using 12-bit ADC (LTC1420) with sampling frequency changed in time segments. The 1V voltage pulse excitation duration was set to 0.1s and the total acqusition time was set to 1000s. For...
-
Results of electrical voltage measurements in reactors - part 1
Open Research DataResults of electric voltage measurements in six reactors using various plantings. These are the results of the project: Integrated approach 3M (Macrophytes-Microbiome-Modelling) to elucidate mechanisms of bioenergy production and micropollutants transformation in Floating Treatment Wetlands combined with Microbial Fuel Cells.
-
Evaluation of expanded uncertainty of instantaneous power measurement in a bearing diagnostic system.
PublicationThe paper presents the issues concerning the estimation of the expanded uncertainty in the system for the diagnosis of rolling bearings, consisting of transducers: voltage and current voltage, which is used for diagnostic bearing motors method based on the measurement and analysis of the instantaneous power signal consumed by the induction motor. It presents the methodology for assessing the measurement uncertainty and presents...
-
Uncertainty estimation of loop impedance measurement determined by the vector method
PublicationThis article presents a detailed analysis of uncertainty estimation of loop impedance measurement determined by the vector method. The analysis includes the following estimates: resistance variance, voltage variance and time measurement variance. This paper presents a methodology for estimating the combined standard uncertainty of loop impedance by the vector method. The vector method allows to determine loop impedance based on...
-
A method of earth fault loop impedance measurement without unwanted tripping of RCDs
PublicationIn low-voltage networks, earth fault loop impedance (EFLI) measurement is the basis for assessing the effectiveness of automatic disconnection of supply. Such a measurement is performed during initial and periodical verification, especially in a TN low-voltage network. Nowadays, due to widespread application of residual current devices (RCDs), such test is difficult in many circuits because RCDs operate during the test. In this...
-
Measurement methods for assessing insulation condition of underground pipelines
PublicationThe paper discusses the most frequently applied measurement methods for assessing the quality of external insulation along pipelines and detecting defect locations in the protective coating. The quality of coating along a given pipeline section under investigation is assessed by determining unitary resistance of the coating, which is calculated on the basis of measurement results obtained along a pipeline subjected to cathodic...
-
Voltage Dependence of Supercapacitor Capacitance
PublicationElectronic Double-Layer Capacitors (EDLC), called Supercapacitors (SC), are electronic devices that are capable to store a relatively high amount of energy in a small volume comparing to other types of capacitors. They are composed of an activated carbon layer and electrolyte solution. The charge is stored on electrodes, forming the Helmholtz layer, and in electrolyte. The capacitance of supercapacitor is voltage- dependent. We...
-
Piotr Chrzan prof. dr hab. inż.
PeopleUrodził się w 1954 r. w Sopocie. Jest absolwentem Wydziału Elektroniki Politechniki Gdańskiej (1978). W 1980 r. podjął pracę na Wydziale Elektrycznym w zespole prof. Jerzego Jaczewskiego. W 1988 r. uzyskał stopień naukowy doktora nauk technicznych, habilitację w 1999 r., w zakresie elektrotechniki: energoelektroniki i automatyki napędu, a tytuł profesora w 2017 r. Był promotorem 6 obronionych prac doktorskich (w tym 3 z wyróżnieniem)....
-
Third harmonic index as a diagnostic tool of high-voltage varistors
PublicationThe recommended methods for standard testing of high-voltage varistors demand application of high voltages and intensive currents that is inconvenient and needs extensive power consumption. These methods require metallization of the prepared ZnO structures that increases costs of testing. Another method of varistor quality and endurance evaluation by the third harmonic index measurement at relatively low voltage range has been...
-
Digital Processing of Frequency–Pulse Signal in Measurement System
PublicationThe work presents the issue of the use of multichannel measurement systems of sensors processing input value to impulse signal frequency. The frequency impulse signal obtained from such sensors is often required to be processed at the same time with a voltage signal which is obtained from other sensors used in the same measurement system. In such case, it is usually necessary to sample the output signals from all sensors in the...
-
AC Motor Voltage and Audible Noise Dataset
PublicationThe dataset titled AC motor voltage and audible noise waveforms in ship’s electrical drive systems with frequency converters contains the voltage and sound measurement results recorded in a marine frequency controlled AC drive system. The dataset is part of research focussing on the impact of the ship’s electrical drive systems with frequency converters on vibrations and the level of audible noise on ships. The dataset allows the...
-
Indirect Measurement of Motor Current Derivatives in PMSM Sensorless Drives
PublicationMotor current derivatives contain useful information for control algorithms, especially in sensorless electric drives. The measurement of motor current derivatives in electric motors supplied by voltage source inverter can be performed using di/dt transducers. However, in such a solution additional sensors have to be installed, e.g. Rogowski coils. Another approach is to measure current derivatives indirectly – by oversampling...
-
Remote current measurement with FPGA digital processing
PublicationThe work presents an implementation of a modular measurement and control systemthat controls variants of mains supply of 230V electrical equipment. The system allowsto supervise power consumption in the office electronic equipment. The system detectsthe instant of the reduced power consumption by a device and makes possible itsswitch-off in order to reduce energy cost. The current is measured with integratedcurrent/voltage converters....
-
Experimental verification of a new method of loop resistance testing in low voltage systems with residual current devices
PublicationA periodical verification of the effectiveness of protection against electric shock shall be performed in low voltage systems. The scope of this verification includes loop impedance/resistance testing. If a residual current device is installed in a tested circuit, this testing is problematic. A residual current device trips out during the test, because of the high value of measurement current. This precludes the execution of the...
-
Using A Particular Sampling Method for Impedance Measurement
PublicationThe paper presents an impedance measurement method using a particular sampling method which is an alternative to DFT calculation. The method uses a sine excitation signal and sampling response signals proportional to current flowing through and voltage across the measured impedance. The object impedance is calculated without using Fourier transform. The method was first evaluated in MATLAB by means of simulation. The method was...
-
Measurement system based on USB Z-Wave controller
PublicationA wireless measurement system based on the Z-Wave standard is presented in this paper. The system is composed of a U SB Z-Stick Gen5 controller connected to a Personal Computer and a Fibaro controller FGRGBWM-441. Operation of the system is controlled by software written in C++ using OpenZWave library. Some metrological aspects of the system are evaluated: accuracy, linearity, resolution and frequency of voltage measurements.
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors
Open Research DataThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
Quality assessment of high voltage varistors by third harmonic index
PublicationHigh voltage varistors that consist of grained ZnO have to be tested before assembling into a surge arrester. The existing methods demand a usage of high voltages and intensive currents that is inconvenient, destructive and needs extensive power consumption. Additionally, these methods require metallization of the prepared varistor structures that increases costs. We propose another method of varistors quality assessments by a...
-
Voltage fluctuations on the main switchgear of the industrial power system supplying the rolling mill motors_part_2
Open Research DataThe dataset presents the voltage waveforms on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data was recorded during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of flickermeter, a hardware...
-
Stanisław Galla dr inż.
PeopleStanisław Galla was born in 1970 in Gdańsk. He graduated from the Secondary Technical School of Mechanical and Electrical Engineering in Gdansk (1990). He studied at the Faculty of Electrical Engineering at Gdansk University of Technology (graduated in 1996). His PhD thesis entitled "Methodology for increasing the accuracy of low frequency measurements of periodic disturbance indicators in low voltage networks" was defended in...
-
Evaluation of the fast impedance spectroscopy method in the laboratory measurement system
PublicationIn this paper the method for fast impedancespectroscopy of technical objects with very high impedance(|Zx| ≥ 1 GΩ) is evaluated by means of simulation and practicalexperiment. The method is based on excitation of an object, witha square pulse and measurements of voltage and currentresponses with DAQ card. The object impedance spectrum isobtained with use of continuous Fourier transform. Someimprovements of the method concerned...
-
Reducing common mode voltage and bearing currents in quasi - resonant DC - link inverter
PublicationIn the paper, a concept of separation of an inverter-fed induction motor drive from its mains supply by two transistor switches inserted in the dc-link circuit is reexamined based on the proposed parallel quasi-resonant dc-link inverter (PQRDCLI). The objective of the paper is to show an advantage of the proposed topology in limiting high frequency common mode voltage and bearing currents. In the laboratory setup, an induction...
-
The harmonic distortion of voltage waveforms in the ship's electrical power system
Open Research DataThe dataset is a part of the research results on the quality of supply voltage on bus bars of the ship's electrical power system's main switchboard in different states of ship exploitation. The attached dataset contains the results of a harmonic distortion analysis expressed by the total harmonic distortion (THD) coefficient of voltage waveforms recorded...
-
The AC motor voltage and audible noise waveforms in ship’s electrical drive systems with frequency converters
Open Research DataThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
The statistic properties of rms voltage and frequency in the ship's electrical power system
Open Research DataThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the results of a statistical analysis of rms voltage and frequency in the ship's electrical power system. The following statistical...
-
Diagnostics of high-voltage varistor quality using resonant ultrasound spectroscopy
PublicationResonant spectroscopy is an effective nondestructive testing method focused on defects detection in tested objects. Resonance spectrum contains an information about the mechanical properties and particularly about the structural homogeneity of the whole object. A swept frequency method has been used to measure the selected resonant frequencies range. The system for measurement of resonant ultrasound spectroscopy of high-voltage...
-
Evaluation of applicability of classic methods of a fault loop impedance measurement to circuits with residual current devices
PublicationMeasurement of fault loop impedance in low voltage grids and systems is in most cases performed to verify the effectiveness of protection against electric shock by automatic disconnection of supply. For the sake of measurement accuracy, it is advisable to perform it using large current. Unfortunately, in circuits with residual current devices which are very widely used nowadays, a large measurement current may trigger those devices...
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublicationIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a sea voyage
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials. The data were recorded during a sea voyage, under normal...
-
Fault Loop Impedance Measurement in Circuits Fed by UPS and Principle of Safety Protection
PublicationThis paper indicates a significant problem of uncertainty of fault loop impedance (FLI) measurement in circuits powered from uninterruptible power supply (UPS) (double-conversion AC-DC-AC). The correctly determined value of this impedance, related to the short-circuit current disconnection time and to the reference value, is one of the most important elements that determines the approval of an electrical installation and its receivers...
-
Multi-Channel Virtual Instrument for Measuring Temperature—A Case Study
PublicationThe article presents the hardware and software configuration of the developed multi-channel temperature measurement system as well as calibration procedures and measurement results verifying the properties of measurement channels. The system has been developed and dedicated primarily for measuring the temperature distribution in a laboratory model simulating underground power lines. With the adopted configuration of the analog...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during maneuvering
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during maneuvering.
-
A measurement method for lossy capacitive relative humidity sensors based on a direct sensor-to-microcontroller interface circuit
PublicationA new time-domain measurement method for determining the capacitance and resistance values of lossy relative humidity capacitive sensors is presented. The method is based on a direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators and timers. The interface circuit consists only of four reference resistors (two reference resistors if a microcontroller includes a voltage reference source),...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during a sea voyage
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during a sea voyage.
-
Verification of safety in low-voltage power systems without nuisance tripping of residual current devices
PublicationLow-voltage power systems require initial and periodical verification to check the effectiveness of protection against electric shock. As a protection in case of fault, automatic disconnection of supply is most often used. To verify such a protection measure, the earth fault loop impedance or resistance is measured. This measurement is easy to perform in circuits without residual current devices. When residual current devices are...
-
Selected results of signal measurements in a ship power station with two generators working in parallel with the use of the Estimator/Analyzer instrument
Open Research DataThe presented dataset is part of research focusing on the assessment of metrological properties of the instrument, Estimator/ Analyser (A/E v.2), developed and made at the Faculty of Electrical Engineering, Department of Marine Electrical Power Engineering, of Gdynia Maritime University. The instrument performs a set of measurement functions that...
-
Leakage Current Measurements of Surge Arresters
PublicationThe paper presents the methods of assessing the technical condition of varistor surge arresters used in laboratory tests and in operation—performed without disconnecting the arresters from the network. The analysis of the diagnostic methods was supplemented with the results of the measurements of the leakage current of arresters coming directly from their production and used in the power industry. Among the available methods of...
-
An Implementation of a Compact Smart Resistive Sensor Based on a Microcontroller with an Internal ADC
PublicationIn the paper a new implementation of a compact smart resistive sensor based on a microcontroller with internal ADCs is proposed and analysed. The solution is based only on a (already existing in the system) microcontroller and a simple sensor interface circuit working as a voltage divider consisting of a reference resistor and the resistive sensor connected in parallel with an interference suppression capacitor. The measurement...
-
The voltage on bus bars of the main switchboard of the ferry electrical power system during a layover at the port
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard the ferry during a layover at the port.
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during maneuvering
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during maneuvering.
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system during sea trials
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier during sea trials.
-
Analysis of the instantaneous power signal for bearing diagnostics -bearing damaged
Open Research DataThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of a damaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Analysis of the instantaneous power signal for bearing diagnostics - bearing undamaged
Open Research DataThe attached dataset contains the measurement results of the instantaneous values of current and voltage, recorded during the diagnostics of an undamaged bearing. Bearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous...
-
Estimation of the uncertainty of the LEM CV 3-500 transducers processing function
PublicationThe paper presents the methodology for estimating uncertainty of a voltage transducer processing function based on the example of LEM CV 3-500 transducer. The analysis was performed using the method based on the GUM Guide propagation of uncertainty law and the Monte Carlo numerical method. The article also presents a comparative analysis of the results of a voltage measurement evaluation done using the Monte Carlo simulation method,...
-
Calibration of NTC 10k thermistors in temperature of 0 C
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Calibration of NTC 10k thermistors in temperature of 100 C
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Calibration of NTC 10k thermistors in temperature of 50 C
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during maneuvering
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results conducted onboard the car carrier at sea trials during maneuvering.
-
Hydrogen sulphide electrocatalytic gas sensor
PublicationIn this article measurement results of the electrocatalytic gas sensor in different concentrations of hydrogen sulphide are presented. Working principle of such sensor is based on electric current acquisition, while voltage ramp is applied to the sensor. During voltage sweep oxidation and reduction reactions occurs on the sensor electrodes. Obtained current-voltage plot has unique shape connected...
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during a sea voyage
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during a sea voyage.
-
Determination of the ratio resistors in the input circuits of the NTC10k thermistor calibration system
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Atomic force microscopy images of copper electrical contacts wear under the influence of friction
Open Research DataMeasurement of wear of copper electrical contacts under the influence of friction. Imaging in contact mode in the variant of scanning spreading resistance microscopy. Additionally, there are spectroscopic current-voltage curves showing local changes in electrical conductivity. NTEGRA Prima (NT-MDT) device. Probe NSG 01Pt.
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 2
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 1 exposition 1
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 1
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
The voltage on bus bars of the main switchboard of the ro-ro ship electrical power system during a layover at the port
Open Research DataThe dataset is part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. The attached dataset contains the measurement results carried out onboard a ro-ro ship during a layover at the port.
-
Testing high impedance analyzer in the field on high-voltage line pylon cell 2 exposition 2
Open Research DataThe dataset presents impedance spectrum of anticorrosion coating on high-voltage line pylon presented in the figure below. This object was used to test high-impedance analyzer for diagnostic of anticorossion coatings (HIADAC) realized in the frame of Eureka project E!3174. The dataset contains comparative measurements with Atlas-Sollich ATLAS98HI analyser....
-
A method of self-testing of an analog circuit terminated by an ADC in electronic embedded systems controlled by microcontrollers
PublicationA new self-testing method of analog parts terminated by an ADC in electronic embedded systems controlled by microcontrollers is presented. It is based on a new fault diagnosis method based on on-line (i.e. during measurement), transformations of voltage samples of the time response of a tested part to a square pulse - onto localization curves placed in the measurement space. The method can be used for fault detection and single...
-
The loop impedance measurement
Open Research DataThe loop impedance measurement
-
A method of self-testing of analog circuits based on fully differential op-amps with theTCBF classifier
PublicationA new approach of self-testing of analog circuits based on fully differential op-amps of mixed-signal systems controlled by microcontrollers is presented. It consists of a measurement procedure and a fault diagnosis procedure. We measure voltage samples of a time response of a tested circuit on a stimulation of a unit step function given at the common-mode reference voltage input of the op-amp. The fault detection and fault localization...
-
Fuel cell noise data
Open Research DataMeasurement data of Hydrogen PEM fuel cels. The voltage fluctuations were measured over single cels of stack of 10 cels.
-
Instantaneous power signal measurements for bearing diagnostics
Open Research DataBearing diagnostics can be carried out based on the method, which relies on the measurement and analysis of the variability of the signal instantaneous power, defined as the product of instantaneous current and voltage power supplied to the engines. Bearing damage causes the appearance of deformations, which are in the form of additional harmonic components...
-
Usage of Two-Center Basis Function Neural Classifiers in Compact Smart Resistive Sensors
PublicationA new solution of the smart resistance sensorwith the Two-Center Basis Function (TCBF) neuralclassifier, for which the resistance sensor is a component ofan anti-aliasing filter of an ADC is proposed. Thetemperature measurement procedure is based on excitationof the filter by square impulses, sampling time response ofthe filter and processing measured voltage values by theTCBF classifier. All steps of the measurement procedure...
-
Determining the leakage current resistive component by the orthogonal vector method
PublicationThe measurement of the metal – oxide surge arresters (MOSA) leakage current and the analysis of its components is a key diagnostic criterion according to technical standards. During on site MOSA condition assessment, the easy way is based on the measurement only leakage current, without the inconvenient live working measurements of supply voltage. Orthogonal vectors method of determination the resistive leakage current is presented....
-
The measurement of input power of power supply in network disturbed by low frequency distortions
PublicationIn the paper authors present results of observation of input power changes versus harmonics amplitude in supply voltage of low-power power supply device. In the study, the electrical measurements supported with thermal imaging were used. The input circuit elements of studied device responsible for input power increase are pointed
-
Verification of a Novel Method of Detecting Faults in Medium-Voltage Systems with Covered Conductors
PublicationThis paper describes the use of new methods of detecting faults in medium-voltage overhead lines built of covered conductors. The methods mainly address such faults as falling of a conductor, contacting a conductor with a tree branch, or falling a tree branch across three phases of a medium-voltage conductor. These faults cannot be detected by current digital relay protection systems. Therefore, a new system that can detect the...
-
Calculations of the resistance values of 10 ratio resistors
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Low frequency nois of supecapacitor
Open Research DataDataset contains results of low frequency noise observation during discharge of commercially available supercapacitor, type DRL 2.7V 10F, with a nominal capacitance 10 F and a nominal voltage 2.7 V. Supercapacitor was charged to various voltages and discharged through a resistor. In the experiment the 50 Ohm and 200 Ohm resistors were used. The supercapacitor...
-
Design of synchronous generator two inputs regulator based on hinf control theory.
PublicationThe power system is highly nonlinear system, its dynamics depends on system network configuration, system loading… etc. To overcome the above mentioned difficulties and fulfill the performance requirements the different control methods are considered and tested for design of synchronous generator control system. Application of the H optimization method to synchronous generator regulator based on measurement of generator voltage...
-
Dynamics of fault arc traveling along busbars in high voltage switchboards = Dynamika łuku zwarciowego przemieszczającego się wzdłuż szyn rozdziel-nic wysokiego napięcia
PublicationThe paper presents the results of magnetic induction and electrodynamic force calculations acting on arc column during short-circuit in medium voltage air-insulated bus-bars. The gap between the bars was 120 mm and the prospective short-circuit currents ranged from 4 kA to 8 kA. The paper also shows the measurement results of average velocity fault arc depending on currents arc diameter and arc current was established and described....
-
Calculations of the resistance values of 20 thermistors at 100°C
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
Calculations of the resistance values of 20 thermistors at 50°C
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
A High-Efficient Low-Voltage Rectifier for CMOS Technology
PublicationA new configuration of rectifier suiting CMOS technology is presented. The rectifier consists of only two nchannel MOS transistors, two capacitors and two resistors; for this reason it is very favourable in manufacturing in CMOS technology. With these features the rectifier is easy to design and cheap in production. Despite its simplicity, the rectifier has relatively good characteristics, the voltage and power efficiency, and...
-
Assessment of Fuel Cells’ State of Health by Low-Frequency Noise Measurements
PublicationWe proposed applying low-frequency (flicker) noise in proton-exchange membrane fuel cells under selected loads to assess their state of health. The measurement set-up comprised a precise data acquisition board and was able to record the DC voltage and its random component at the output. The set-up estimated the voltage noise power spectral density at frequencies up to a few hundred mHz. We observed the evolution of the electrical...
-
Identification of the customer meter assignment to phases in LV grid: Selected issues of UPGRID project realization
PublicationThe paper presents selected issues on the European UPGRID grant implemented by a consortium of companies from seven European states, including from Poland, on the monitoring and control of low voltage grid using measurement pre-registered data by smart AMI meters. The paper focuses on the issue of lack of information on the assignment of communal meters to individual phases.
-
Investigation of the thermal conductivity of λ gypsum using the hot wire method
Open Research DataAn experimental study was conducted to determine the thermal conductivity coefficient λ using the ‘hot wire’ method for a building material. Gypsum specimens measuring 400 x 60 x 50 mm were made for the experiment. Along the long axis of the model, an insulated resistance wire with a diameter of 0.2 mm was poured into the gypsum slurry in the centre...
-
Calculations of the resistance values of 20 thermistors at 0°C
Open Research DataThe presented data set is part of the research aimed at determining the actual characteristics of each thermistor in a package of twenty NTC10k type sensors.
-
The voltage on bus bars of the main switchboard of the car carrier electrical power system at sea trials during a bow thruster start-up
Open Research DataThe dataset is a part of the research results on the quality of supply voltage on bus bars of the main switchboard of the ship's electrical power system in different states of ship exploitation. In ships' electrical power systems, disturbances occurring in voltage waveforms on bus bars of the main switchboard are connected mainly with the processes...
-
The radiated immunity test of an astable multivibrator for various supply voltages
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator supplied from a power supply with an output voltage of 6V and 7.5 V. Tests of immunity of electronic systems to radiated radio frequency (RF)...
-
Effect of the let-through energy of overcurrent protective devices on the temperature of conductors during short-circuits
PublicationThe scope of the verification of low-voltage systems covers the earth fault loop impedance measurement. This measurement is usually performed with the use of low-value current meters, which force a current many times lower than the one occurring during a real short-circuit. Therefore, the international standard recommends consideration of the increase of resistance of conductors with the increase of temperature, which may occur...
-
The conducted immunity test of a power supply unit in accordance with EMC standards
Open Research DataThe dataset presents a result of measurements that are a part of immunity tests to conducted disturbances, induced by radio-frequency fields. The immunity tests were carried out on the mains cable of the DF1723003TC NDN power supply. Tests of immunity of electronic systems to conducted disturbances in the frequency range from 150 kHz to 230 MHz are...
-
Low frequency nois of supecapacitor
Open Research DataDataset contains noise measurement results on prototype electrochemical double layer capacitor. The measurement procedure is described in https://dx.doi.org/10.1515/mms-2017-0059.
-
Frequency Diagnostics of Transformer Insulating Parameters
PublicationIn the article is presented experimental analysis and diagnostics of insulating system oil-paper for power transformers, mainly by progressive frequency method – dielectric spectroscopy. In the 1-st part of the article is described base theory about measurement and diagnostics insulating part (oil and paper) of power transformers. In the 2-nd part of article is described measuring method of insulating frequency diagnostics - frequency...
-
Magnetic field maps of an astable multivibrator in frequency range from 30 MHz to 3 GHz – spatial detection
Open Research DataThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain magnetic field maps created on based measurements...
-
Magnetic field maps of an astable multivibrator in frequency range from 100 kHz to 50 MHz
Open Research DataThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain magnetic field maps created on based measurements...
-
Electric field maps of an astable multivibrator in frequency range from 30 MHz to 3 GHz
Open Research DataThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain electric field maps created on based measurements...
-
Time-domain measurement methods for R, L and C sensors based on aversatile direct sensor-to-microcontroller interface circuit
PublicationtIn the paper new time-domain measurement methods for determining values of resistive (R), inductive(L) and capacitive (C) sensors based on a versatile direct sensor-to-microcontroller interface for microcon-trollers with internal analog-to-digital converters (ADCs) and analog comparators (ACs) are presented.The interface circuit consists of a reference resistor Rrworking as a voltage divider, a given R, L or C sensorand a microcontroller...
-
Induction Generator with Direct Control and a Limited Number of Measurements on the Side of the Converter Connected to the Power Grid
PublicationThe article presents an induction generator connected to the power grid using the AC/DC/AC converter and LCL coupling filter. Three-level inverters were used in the converter, both from the generator side and the power grid side. The algorithm realizing Pulse Width Modulation (PWM) in inverters has been simplified to the maximum. Control of the induction generator was based on the Direct Field-Oriented Control (DFOC) method. At...
-
Quality assessment of ZnO-based varistors by 1/f noise
PublicationNoise has been used as a diagnostic tool of surge arrester varistor structures comprising of ZnO grains of various type and size. The physical and electrical properties of the measured samples have been described. In the experimental study, the applied measurement system and the results of noise measurements for the selected structures of varistors designed for the continuous working voltage 280 V, 440 V and 660 V have been presented....
-
Self-Testing of Analog Parts Terminated by ADCs Based on Multiple Sampling of Time Responses
PublicationA new approach for self-testing of analog parts terminated by analog-to-digital converters in mixed-signal electronic microsystems controlled by microcontrollers is presented. It is based upon a new fault diagnosis method using a transformation of the set of voltage samples of the time response of a tested analog part to a square impulse into localization curves placed in a multidimensional measurement space. The method can be used...
-
A compact smart sensor based on a neural classifier for objects modeled by Beaunier's model
PublicationA new solution of a smart microcontroller sensor based on a simple direct sensor-microcontroller interface for technical objects modeled by two-terminal networks and by the Beaunier’s model of anticorrosion coating is proposed. The tested object is stimulated by a square pulse and its time voltage response is sampled four times by the internal ADC of microcontroller. A neural classifier based on measurement data classifies the...