displaying 1000 best results Help
Search results for: PASSIVE SAMPLERS
-
Oznaczanie stężeń jonów fluorkowych w próbkach wody pitnej z terenu miasta Malborka = Determination of fluoride ions in drinking water samples collected from the area of the town of Malbork
PublicationW pracy przedstawiono badania próbek wody pitnej z terenu miasta Malborka. Próbki wody pobierano sześciokrotnie (w miesięcznych odstępach - październik 2008, listopad 2008, grudzień 2008, styczeń 2009, luty 2009 oraz marzec 2009) w siedmiu punktach leżących w głównych dzielnicach miasta Malborka. Pobrane próbki podano analizie w celu oznaczenia następujących parametrów: zawartość anionów: F-, Cl-, Br-, 2NO , 3NO , 34 PO , 24 SO...
-
Rapid and simple multi-analyte LC–MS/MS method for the determination of benzodiazepines and Z-hypnotic drugs in blood samples: Development, validation and application based on three years of toxicological analyses
PublicationBenzodiazepines (BZDs) and Z-drugs have been particularly important treatments for sleeping and anxiety disorders for many years. However, recently, a number of new benzodiazepines (named designer benzodiazepines, DBZDs) were synthesised, but some of them have never been used in the clinic; they reached the black drug market as new psychoactive substances and are used for recreational purposes. The abuse of these substances has...
-
Sample ecourse
e-Learning Courses -
UHF ESPAR antenna for simple Angle of Arrival estimation in UHF RFID applications
PublicationAn electronically switched beam antenna for localization of passive UHF RFID tags based on a simple Angle of Arrival (AoA) technique is proposed‥ Detailed antenna design and realization are presented together with corresponding simulations and measurement results. Experimental tests with passive UHF RFID tag show the validity of theoretical assumptions for application of the antenna in UHF RFID based localization systems.
-
Membrane-SPME the best 'green' sample preparation technique for the gas chromatographic determination polar organic pollutants in polar media
PublicationOne of the most popular technique for sample preparation, which fulfill requirements of green analytical chemistry, is solid phase microextraction (SPME). Because of the undoubted advantages of SPME technique, solvent-free character of the extraction process and the enormous potential in analytical practice, a series of studies has been undertaken to develop new technical solutions, where improving the sensitivity and the extraction...
-
Verification of the homogeneity of the matrix/analyte mixture on sample plate using MALDI-MS technique and new ionic liquid matrices
Publication -
Three-step stacking by field-enhanced sample injection, sweeping, and micelle to solvent stacking in capillary electrophoresis: Anionic analytes
Publication -
Three-step stacking of cationic analytes by field-enhanced sample injection, sweeping, and micelle to solvent stacking in capillary electrophoresis
Publication -
Determination of Pesticide Residues in Honeybees using Modified QUEChERS Sample Work-Up and Liquid Chromatography-Tandem Mass Spectrometry
PublicationIncreasing emissions of chemical compounds to the environment, especially of pesticides, is one of factors that may explain present honeybee colony losses. In this work, an analytical method employing liquid chromatography-tandem mass spectrometry (LC-MS/MS) was optimized for the simultaneous screening of 19 pesticides which have not been yet determined in honeybee samples from northern Poland (Pomerania). The sample preparation,...
-
Analysis of pesticide residues in fruits and vegetables using QuEChERS sample preparation method and gas chromatography with electron capture detection
PublicationPesticides are a numerous and diverse group of chemical compounds. They are some of the most toxic substances contaminating the environment, which are used to eliminate pests in agriculture and the household. Despite considerable progress in the development of methods for preparing samples for analysis and for the final determination of analytes, the analysis of pesticides in biological samples continues to present challenges to...
-
Active Suppression of Nonstationary Narrowband Acoustic Disturbances
PublicationIn this chapter, a new approach to active narrowband noise control is presented. Narrowband acoustic noise may be generated, among others, by rotating parts of electro-mechanical devices, such as motors, turbines, compressors, or fans. Active noise control involves the generation of “antinoise”, i.e., the generation of a sound that has the same amplitude, but the opposite phase, as the unwanted noise, which causes them to interfere...
-
Michał Tomasz Kucewicz dr
PeopleMichal Kucewicz was born in 1986 in Gdansk. In 2005 he completed International Baccalaureate programme in Topolowka (III High School in Gdańsk). Thanks to the G. D. Fahrenheit scholarship, he moved to the United Kingdom to study neuroscience. He received his Bachelor’s and Master’s degree from the Cambridge University, and his doctoral degree from the University of Bristol specializing in electrophysiology of memory and cognitive...
-
What should we know when choosing feather, blood, egg or preen oil as biological samples for contaminants detection? A non-lethal approach to bird sampling for PCBs, OCPs, PBDEs and PFASs
PublicationBirds are considered as good bio-monitors and they can provide highly valuable data about the level of contamination in their habitat. During the design of biomonitoring studies one of the first issues after choosing species is the choice of biological material. Non-lethally collected samples have recently been gaining greater attention as they offer several ethical and practical advantages. However, not all sample matrices are...
-
Corrosion Resistance and Surface Bioactivity of Ti6Al4V Alloy after Finish Turning under Ecological Cutting Conditions
PublicationThe influence of cooling conditions and surface topography after finish turning of Ti6Al4V titanium alloy on corrosion resistance and surface bioactivity was analyzed. The samples were machined under dry and minimum quantity lubrication (MQL) conditions to obtain different surface roughness. The surface topographies of the processed samples were assessed and measured using an optical profilometer. The produced samples were subjected...
-
Technical fabrics old sample
Open Research DataThe data presented here includes video of technical fabric strength testing. The included movie is in .cine format, and an external program with a viewer for such movies is required.
-
Technical fabrics sample 1
Open Research DataThe data presented here includes 3 videos of technical fabrics strength testing. The included movies are in .cine format, and an external program with a viewer for such movies is required.
-
Technical fabrics sample 2
Open Research DataThe data presented here includes 3 videos of technical fabrics strength testing. The included movies are in .cine format, and an external program with a viewer for such movies is required.
-
Monitorowanie i mapowanie zanieczyszczenia powietrza atmosferycznego przez związki z grupy BTEX (benzen, toluen, etylobenzen, ksylen) z wykorzystaniem techniki dozymetrii pasywnej do pobierania próbek analitów = Monitoring and mapping of atmospheric pollutans with the use of passive technique of sampling of BTEX (benzene, ethylbenzene, toluene, xylenes) analytes
PublicationWskutek działalności człowieka do atmosfery dostaje się coraz większa liczba substancji szkodliwych, uznanych za potencjalnie niebezpieczne dla organizmów żywych, głównie z uwagi na ich toksyczność. Do takich substancji zalicza się między innymi związki z grupy BTEX. Chcąc ocenić stopień narażenia populacji na obecność w powietrzu atmosferycznym analitów z grupy BTEX, niezbędne jest monitorowanie poziomu stężeń tych zanieczyszczeń...
-
The XRD diffraction patterns of Ce(Pr,Sm)O2-s samples
Open Research DataThe dataset includes XRD diffraction patterns of Ce(Pr,Sm)O2-s samples of various stoichiometries of Pr and Sm dopants. Samples were produced using aqueous soft chemistry methods (microemulsion method).
-
The XRD diffraction patterns of Ce(Gd,Pr)O2-s samples
Open Research DataThe dataset includes XRD diffraction patterns of Ce0.8Gd0.2O2-s and Ce0.8Pr0.2O2-s sintered at 600oC under air atmosphere for 4 h. Samples were produced using aqueous soft chemistry methods (Pechini).
-
Ultrasound-Assisted Solvent Extraction of a Porous Membrane Packed Sample for the Determination of Tobacco-Specific Nitrosamines in the Replacement Liquids for E-Cigarettes
PublicationThe content of tobacco-specific nitrosamines (TSNAs) possessing carcinogenic properties has been an important area of research since replacement liquids were introduced for e-cigarettes. A method for determining N′-nitrosonornicotine (NNN), 4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), N′-nitrosoanatabine (NAT), and N′-nitrosoanabasine (NAB) in replacement liquids for electronic cigarettes was developed using liquid chromatography–tandem...
-
Matrix solid-phase dispersion (MSPD) as simple and useful sample preparation technique for determination of polybrominated diphenyl ethers (PBDEs) in dust
PublicationIn the present study a novel analytical procedure for the determination of polybrominated diphenylethers in dust samples was developed.The main aim of the research was the selection of the optimum conditions of the matrix solid-phasedispersion before thefinal determination of polybrominated diphenyl ethers in dust samples. In order toassess the best usefulness of this technique, a favourable ratio of sample amount to the mass ofdispersing...
-
Box-Behnken design optimization of pipette tip solid phase extraction for methyl orange and acid red determination by spectrophotometry in seawater samples using graphite based magnetic NiFe2O4 decorated exfoliated as sorbent
Publication -
FLAME ATOMIC ABSORPTION SPECTROMETRIC DETERMINATION OF TRACE AMOUNTS OF SILVER IN RADIOLOGICAL WASTE SAMPLES AFTER SOLID PHASE EXTRACTION USING MULTI-WALLED CARBON NANO-TUBES MODIFIED BY SODIUM DODECYL SULFATE
Publication -
New type T-Source inverter
PublicationThis paper presents different topologies of voltage inverters with alternative input LC networks. The basic topology is known in the literature as a Z-source inverter (ZSI). Alternative passive networks were named by the authors as T-sources. T-source inverter has fewer reactive components in comparison to conventional Z-source inverter. The most significant advantage of the T-source inverter (TSI) is its use of a common voltage...
-
Power Grid Frequency Estimation Based on Zero Crossing Technique Using Least Squares Method to Approximate Sampled Voltage Signal Around Zero Level
Publication -
Portable Electronic Nose Based on Electrochemical Sensors for Food Quality Assessment
PublicationThe steady increase in global consumption puts a strain on agriculture and might lead to a decrease in food quality. Currently used techniques of food analysis are often labour-intensive and time-consuming and require extensive sample preparation. For that reason, there is a demand for novel methods that could be used for rapid food quality assessment. A technique based on the use of an array of chemical sensors for holistic analysis...
-
Hanging drop cathode-atmospheric pressure glow discharge as a new method of sample introduction for inductively coupled plasma-optical emission spectrometry
Publication -
Development of a solventless stir bar sorptive extraction/thermal desorption large volume injection capillary gas chromatographic-mass spectrometric method for ultra-trace determination of pyrethroids pesticides in river and tap water samples
Publication -
Application of Box–Behnken design in the optimization of a simple graphene oxide/zinc oxide nanocomposite-based pipette tip micro-solid phase extraction for the determination of Rhodamine B and Malachite green in seawater samples by spectrophotometry
Publication -
Fast, sensitive and reliable multi-residue method for routine determination of 34 pesticides from various chemical groups in water samples by using dispersive liquid – liquid microextraction coupled with gas chromatography – mass spectrometry
PublicationA simple and efficient dispersive liquid-liquid microextraction technique (DLLME) was developed by using a mixture of two solvents: 40 μL of tetrachlorethylene (extraction solvent) and 1.0 mL of methanol (disperser solvent), which was rapidly injected with a syringe into 10mL ofwater sample. Some important parameters affecting the extraction efficiency, such as type and volume of solvents, water sample volume, extraction time,...
-
Identification attempts of toluene sources in post-flood sediment samples from the Odra river (flood 1997). Identyfikacja źródeł toluenu w próbkach osadów popowodziowych pobranych z rzeki Odry (powódź 1997).
PublicationPrzedstawiono badania mające na celu oznaczanie zawartości toluenu w próbkach osadów dennych i w próbkach mikrobiologicznych. W badaniach wykorzystano zestaw do jednoczesnego wymywania i wychwytywania analitów na stałym sorbencie (Purge and Trap). Oznaczenia końcowe wykonano z wykorzystaniem techniki chromatografii gazowej połączonej ze spektrometrem mas.
-
Złote monety bulionowe – testowanie pasywnego charakteru inwestycji
PublicationCel – Wyznaczenie składu optymalnego portfela inwestycyjnego o minimalnym ryzyku, zawierającego inwestycję w polskie monety bulionowe (Orzeł Bielik) oraz inwestycję na polskiej giełdzie papierów wartościowych. Testowanie pasywnego charakteru inwestycji w monety. Metodologia badania – Konstrukcja portfeli inwestycyjnych o minimalnym ryzyku według teorii H.M. Markowitza. Autorska metoda badania pasywnego charakteru inwestycji...
-
Analityka surfaktantów w próbkach środowiskowych
PublicationSurfaktanty stanowią grupę związków charakteryzujących się specyficznymi właściwościami fizykochemicznymi (m.in. amfifilowa budowa, zdolność rozpuszczania się w cieczach o różnej polarności, zdolność do tworzenia micelli) i z tego względu są one wykorzystywane w wielu sferach działalności człowieka. Związki powierzchniowo-czynne ulegają różnorodnym przemianom fizykochemicznym, co umożliwia ich migrację między różnymi elementami...
-
bio-based polyester polyols - chemical structure of Miniatura 4 proper samples
Open Research DataPresented results are related with project MINIATURA 4 realization. At the document, the chemical structure of bio-based polyester polyols (poly(propylene-co-propan-1,2,3-triol succinate)s) are presented as analysis of FTIR and H NMR spectroscopy.
-
Depth chemical profile in a CeIr3 sample
Open Research DataThe polycrystalline sample of CeIr3 used in the present studies was synthesized by arc-melting cerium (4N) and iridium (3N5) in an arc furnace on a water-cooled copper hearth using a tungsten electrode under a high purity argon atmosphere. A piece of zirconium was used as an oxygen getter. First, a button of Ir was prepared by arc-melting the iridium...
-
Farzin Kazemi Ph.D. Student at Gdansk University of Technology
PeopleHis main research areas are seismic performance assessment of structures and seismic hazard analysis in earthquake engineering. He performed a comprehensive study on the effect of pounding phenomenon and proposed modification factors to modify the seismic collapse capacity of structures or predict the seismic collapse capacity of structures which were retrofitted with linear and nonlinear Fluid Viscous Dampers (FVDs). His current...
-
Fast Design Closure of Compact Microwave Components by Means of Feature-Based Metamodels
PublicationPrecise tuning of geometry parameters is an important consideration in the design of modern microwave passive components. It is mandatory due to limitations of theoretical design methods unable to quantify certain phenomena that are important for the operation and performance of the devices (e.g., strong cross-coupling effects in miniaturized layouts). Consequently, the initial designs obtained using analytical or equivalent network...
-
The possibility of application of the potentiometric sensor with all-solid-state electrodes containing lipid-polymer membranes for classification of tested black leaf teas in terms of their quality
PublicationPotentiometric sensor with all-solid-state electrodes containing lipid-polymer membranes for a set of black leaf teas coming from four countries (China, India, Sri Lanka and Kenia) classification was applied. The tested tea samples were reassigned to quality classes marked with numbers I–V according to the information available. The sensor results of tea samples are presented in the form of radar charts. It was observed that, in...
-
Effect of native air-formed oxidation on the corrosion behavior of AA7075 aluminum alloys
PublicationThe microstructure of aluminum alloys plays a key role in their corrosion resistance. In particular, the presence of intermetallic precipitates differing in the potential from the alloy matrix induces local corrosion. The study presents the effect of native air-formed oxidation on the corrosion behavior of AA 7075 aluminum alloy. Various microscopic and spectroscopic techniques were used to examine the changes occurring in the...
-
Nowoczesne techniki przygotowania próbki do oznaczania analitów organicznych z zastosowaniem chromatografii gazowej. Część II. Aparatura. Modern techniques of preparation of samples for determining organic analytes by gas chromatography. Part II. Instrumentation.
PublicationW pracy dokonano przeglądu szerokiego spektrum technik przygotowania próbki ze szczególnym uwzględnieniem technik o charakterze prośrodowiskowym. Opisu technik dokonano pod kątem wykorzystywanych mechanizmów izolacji analitów oraz stosowanych rozwiązań aparaturowych.
-
The effect of anthropogenic activity on BTEX, NO2, SO2, and CO concentrations in urban air of the spa city of Sopot and medium-industrialized city of Tczew located in North Poland
PublicationThe major goal of the present study is to compare the air quality of two urban locations situated in Northern Poland – the spa City of Sopot and the medium-industrialized city of Tczew using chemometric methods. As a criterion for the assessment of atmospheric air quality, measurements of benzene, toluene, ethylbenzene and total xylenes were used (collected from atmospheric air using diffusion-type passive samplers) as well as...
-
Near Field Coupled Wireless Microwave Sensor
PublicationThis paper presents a wireless planar microwave sensor operating at industrial scientific and medical (ISM) frequency for the detection of dielectric materials. The microwave sensor consists of a reader (ground defected microstrip coupled line) and a passive tag where a complementary split-ring resonator (CSRR) is made on the commercially available copper-foil. The CSRR is a peel-off type tag that is excited using the near field...
-
Biological and mechanical research of titanium implants covered with bactericidal coating
PublicationThe paper concerns the biological and mechanical properties of titanium implants with an antibacterial coating. The Ti13Zr13Nb alloy samples were coated with hydroxyapatite (HAp) coatings using the electrophoretic deposition technique (EPD). Subsequently, the surface of the samples was modified with silver, copper, and nickel nanoparticles by the immersion method. Different titanium sample types (i.e. HAp-only and nanometals-enriched...
-
Application of polyethylene glycol-coated iron oxide nanoparticles for magnetic solid phase extraction of copper from seawater samples and its determination by graphite furnace atomic absorption spectrometry using response surface methodology for optimization of extraction
Publication -
Problems and challenges associated with estimating the emissions of organic compounds from indoor materials
PublicationFor several years intensive research has been carried out with the aim of developing a database of the types and amounts of pollutants released from indoor materials to the indoor environment. The paper discusses in detail basic problems and challenges encountered when estimating the emissions of chemical compounds released from of indoor materials. Factors affecting the validity of data obtained by using two different types of...
-
Monitoring and analytics of semivolatile organic compounds (SVOCs) in indoor air
PublicationThis paper reviews literature information on the behaviour of semivolatile organic compounds (SVOCs) in the indoor environment, as well as the most likely emission sources. The consecutive stages of analytical procedures used for monitoring SVOCs in indoor environments are described. The most common approaches used for collecting samples from the gas and particulate phases are mentioned. The paper discusses and compares various...
-
Toxoplasma godnii recombinant chimeric antigens - IgM and IgG ELISAs - mouse serum samples
Open Research DataThis study presents an evaluation of tetravalent recombinant chimeric proteins containing fragments of the Toxoplasma gondii antigens, SAG2, SAG1, GRA1, GRA2, MIC1, MAG1, ROP1 and AMA1, as potential replacements of a the soluble, whole-cell tachyzoite lysate (TLA) used in serological assays. Recombinant chimeric proteins (SAG1-MIC1-MAG1-GRA2, SAG2-GRA1-ROP1-GRA2,...
-
Toxoplasma gondii recombinant chimeric antigens - IgG and IgM ELISAs - human serum samples
Open Research DataThis study presents an evaluation of tetravalent recombinant chimeric proteins containing fragments of the Toxoplasma gondii antigens, SAG1, SAG2, GRA1, GRA2, MIC1, MAG1, ROP1 and AMA1, as potential replacements of a the soluble, whole-cell tachyzoite lysate (TLA) used in serological assays. Recombinant chimeric proteins (SAG1-MIC1-MAG1-GRA2, SAG2-GRA1-ROP1-GRA2,...
-
Hybrid energy storage forelectric multiple units to operate at the partially electrified line Gdynia -Hel
PublicationThe article presents calculations enabling the selection of an on-board energy storage device to replace diesel-powered trains with modern storage multiple units on the example railway line Gdynia Główna -Hel. The pioneering and currently used storage electric multiple units, mainly in Europe, were presented. The condensed results of the inventory of the line in question, including the technical condition...