Wyniki wyszukiwania dla: calibration model
-
Visual Object Tracking System Employing Fixed and PTZ Cameras
PublikacjaThe paper presents a video monitoring system utilizing fixed and PTZ cameras for tracking of moving objects. First type of camera provides image for background modelling, being employed for foreground objects localization. Estimated objects locations are then utilised for steering of PTZ cameras when observing targeted objects with high close-ups. Objects are classified into several classes, then basic event detection is being...
-
RSS-Based DoA Estimation for ESPAR Antennas Using Support Vector Machine
PublikacjaIn this letter, it is shown how direction-of-arrival (DoA) estimation for electronically steerable parasitic array radiator (ESPAR) antennas, which are designed to be integrated within wireless sensor network nodes, can be improved by applying support vector classification approach to received signal strength (RSS) values recorded at an antenna's output port. The proposed method relies on ESPAR antenna's radiation patterns measured...
-
The changes of outlet gases concentrations from SOFC with Ce(Pr,Sm)O2-s layers
Dane BadawczeThe dataset includes The changes of outlet gases concentrations from SOFC with Ce(Pr,Sm)O2-s layers. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding.
-
Images of the Seabed of the Gulf of Gdansk Obtained by Means of the Parametric Sonar
PublikacjaThe main goal of this paper is to present results of the experimental investigation of the seabed by means of parametric echosounder in the form of chosen images. The phenomena of nonlinear interaction between two parallel beams of high intensity gives as a results very narrow beam of low frequency wave, that enables to penetrate the sea bottom. The first step of our investigations was calibration of all the elements of the measuring...
-
Gdansk Bay sea bed sounding and classification of its results
PublikacjaThe main goal of this paper is to describe the results of sounding the Gdansk Bay sea bed by using a SES-2000 Standard parametric sub-bottom profiler. Quality of data obtained during trials depends inter alia on a proper location of transducer array to reduce influence of pitch, roll and heave motions as well as ship self noise (resulting from bubbles due to propeller and flow around hull, vibration generated by main engine and...
-
Comparative testing of numerical models of river ice jams
PublikacjaIce processes in general, and ice jams in particular, play a dominant role in the hydrologic regime of Canadian rivers, often causing extreme floods and affecting the life cycle of many aquatic, terrestrial, and avian species. Various numerical models have been developed to help simulate the formation and consequences of these very dynamic and often destructive jam events. To test and compare the performance of existing models,...
-
Loudness Scaling Test Based on Categorical Perception
PublikacjaThe main goal of this research study is focused on creating a method for loudness scaling based on categorical perception. Its main features, such as: way of testing, calibration procedure for securing reliable results, employing natural test stimuli, etc., are described in the paper and assessed against a procedure that uses 1/2-octave bands of noise (LGOB) for the loudness growth estimation. The Mann-Whitney U-test is employed...
-
Application and evaluation of M-EPDG for performance analysis of Polish typical flexible and rigid pavements
PublikacjaThe main goal of the paper is to implement and evaluate the M-EPDG and the software AASHTOware to analyse the performance of new flexible and rigid pavements designed according to the Polish catalogues, which are comparable with analogous catalogues used in other European countries. For this purpose the site-specific inputs for Poland were determined and described in the paper as well as compared to the default input data used...
-
A New Approach to Capacitive Sensor Measurements Based on a Microcontroller and a Three-Gate Stable RC Oscillator
PublikacjaA complete smart capacitive sensor solution basedA complete smart capacitive sensor solution based on a microcontroller was developed. This approach includes the development of both the hardware and software. The hardware part comprises an 8-bit microcontroller equipped with two timers/counters and a three-gate stable RC relaxation oscillator. The software part handles system configuration, measurement control, communication control,...
-
Selectivity of amperometric gas sensors in multicomponent gas mixtures
PublikacjaIn recent years smog and poor air quality became a growing environmental problem. There is a need to continuously monitor the quality of air. The lack of selectivity is one of the most important problems limiting the use of gas sensors for this purpose. In this study, a selectivity of the six amperometric gas sensors is being investigated. Calibration of sensors has been performed in order to find a correlation between concentration...
-
Testing of the longest span soil-steel bridge in Europe – new quality in measurements
PublikacjaThe article describes interdisciplinary and comprehensive diagnostic tests of final bridge inspection and acceptance proposed for a soil – steel bridge made of corrugated sheets, being the European span length record holder (25.74 m). As an effect of an original concept a detailed and precise information about the structure response was collected. The load test design was based on the nonlinear numerical simulations performed by...
-
Pure cross-anisotropy for geotechnical elastic potentials
PublikacjaThe pure cross-anisotropy is understood as a special scaling of strain (or stress). The scaled tensor is used as an argument in the elastic stiffness (or compliance). Such anisotropy can be overlaid on the top of any elastic stiffness, in particular on one obtained from an elastic potential with its own stress-induced anisotropy. This superposition does not violate the Second Law. The method can be also applied to other functions...
-
Development of Local IDF-formula Using Controlled Random Search Method for Global Optimization
PublikacjaThe aim of the study is to present the effective and relatively simple empirical approach to rainfall Intensity-Duration-Frequency-formulas development, based on Controlled Random Search (CRS) for global optimization. The approach is mainly dedicated to the cases in which the commonly used IDF-relationships do not provide satisfactory fit between simulations and observations, and more complex formulas with higher number of parameters...
-
Towards hand grip force assessment by using EMG estimators
PublikacjaThe purpose of this study was to propose a method to assess individual regression (calibration) curves to establish a relationship between an isometric grip force and surface electromyography (EMG) estimator. In this study 18 healthy volunteers (12 male (23.0 ± 2.0 years) and 6 female (23.2 ± 0.7 years)) had been examined. Ten EMG estimators (mean absolute value, root mean square, entropy, energy, turns per second, mean of zero...
-
Acoustic imaging of selected areas of Gdansk Bay with the aid of parametric echosounder and side-scan sonar
PublikacjaThe article presents and analyses the data recorded during sounding of the Gdansk Bay seabed with the aid of a parametric echosounder and a side-scan sonar. The accuracy of seabed structure examination, as a condition for obtaining valuable results, requires correct configuration of echolocation devices and proper calibration of peripheral devices, such as the survey unit geographical position sensor – GPS, the navigation unit,...
-
DLC coating in ring-on-ring sliding with water lubrication 10MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was augmented by vibration...
-
DLC coating in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 20MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h. The test was augmented...
-
DLC coating in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 10MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h. The test was augmented...
-
DLC coating in ring-on-ring sliding with water lubrication 20MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was augmented by vibration...
-
DLC coating doped with W in ring-on-ring sliding with water lubrication 20MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was...
-
DLC coating doped with W in ring-on-ring sliding with water lubrication 10MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: WATER. Tribometer: PT-3. Overall test time >15h. The test was...
-
An new method of audio-visual correlation analysis
PublikacjaThis paper presents a new methodology of conducting the audio-visual correlation analysis employing the gaze tracking system. Interaction between two perceptual modalities, seeing and hearing, their interaction and mutual reinforcement in a complex relationship was a subject of many research studies. Earlier stage of the carried out experiments at the Multimedia Systems Department (MSD) showed that there exists a relationship between...
-
Combined analysis of whole human blood parameters by Raman spectroscopy and spectral-domain low-coherence interferometry
PublikacjaIn this article the simultaneous investigation of blood parameters by complementary optical methods, Raman spectroscopy and spectral-domain low-coherence interferometry, is presented. Thus, the mutual relationship between chemical and physical properties may be investigated, because low-coherence interferometry measures optical properties of the investigated object, while Raman spectroscopy gives information about its molecular...
-
Simultaneous determination of individual isothiocyanates in plant samples by HPLC-DAD-MS following SPE and derivatization with N-acetyl-l-cysteine
PublikacjaThe procedure for the isothiocyanates (ITCs) determination that involves derivatization with N-acetyl-l-cysteine (NAC) and separation by HPLC was developed. Prior to derivatization, plant ITCs were isolated and purified using solid-phase extraction (SPE). The optimum conditions of derivatization are: 500 μL of isopropanolic eluate obtained by SPE combined with 500 μL of derivatizing reagent (0.2 M NAC and 0.2 M NaHCO3 in water)...
-
Comprehensive determination of flavouring additives and nicotine in e-cigarette refill solutions. Part I: Liquid chromatography-tandem mass spectrometry analysis
PublikacjaLiquid chromatography-tandem mass spectrometry with electrospray ionization (HPLC-ESI–MS/MS) methods were developed for the simultaneous determination of 42 flavouring compounds and nicotine in liquids for e-cigarettes. The chromatographic separation was performed using an Ace® Ultracore™ SuperC18™ (100 × 2.1 mm, 2.5 μm) column in both acidic and alkaline pH conditions to separate all the compounds. A simple “dilute & shoot” approach...
-
Extraction and Analysis of Bisphenols and Their Derivatives in Infant and Toddler Ready-to-feed Meals by Ultrasound-assisted Membrane Extraction Followed by LC MS/MS
PublikacjaThis research developed an ultrasound-assisted membrane extraction coupled with liquid chromatography-tandem mass spectrometry method for the determination of nineteen bisphenols and their derivatives in infant and toddler ready-to-feed meals. The calibration curves for all analytes were linear in the tested range, and the limit of detection and limit of quantitation were in the range 0.27 to 0.79 ng/g and 0.80 to 2.4 ng/g, respectively....
-
DLC coating doped with W in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 20MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 20MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h....
-
DLC coating doped with W in ring-on-ring sliding with saline solution (0.9% wt.) lubrication 10MPa/0.1m/s
Dane BadawczeWear tests in sliding friction of 1% W (tungsten) doped DLC coating on 1.4021 (EN 10088-1) heat treated stainless steel. Ring - on - ring contact in unidirectional sliding, DLC-W over DLC-W. Mean contact stress: 10MPa. Sliding velocity: 0,1 m/s. Mean friction radius: 9.5mm. Lubricant: SALINE SOLUTION (0.9% wt.). Tribometer: PT-3. Overall test time >15h....
-
Force-deformation spectroscopy in contact mode
Dane BadawczeThe deformation-distance spectroscopic curve is obtained by registering the value of the probe cantilever deflection as a function of the elongation of the piezoelectric scanner. It assumes a simple relationship in the form of Hooke’s law, linking the deformation of the lever with the amount of its deflection caused by the proximity of the probe and...
-
Evaluating the influence of radiative heat flux on convective heat transfer from a vertical plate in air using an improved heating plate
PublikacjaThis article examines the influence of radiative heat flux on the accuracy of the results of free convective heat transfer in air. In order to carry out these tests, based on the experience gained during the operation of a plate heated on one side, compensated by a reverse heat loss flux counter-heater, a unique double-sided heating sandwich plate was designed and built, consisting of three thin epoxy resin plates reinforced with...
-
Levels of 13 multi-class pesticide residues in Polish honeys determined by LC-ESI-MS/MS
PublikacjaLevels of 13 pesticides in 40 honey samples form Poland are reported. A rapid and sensitive method was developed for the LC-ESI-MS/MS determination of multi-class pesticide residues in honey samples. Liquid-liquid extraction (LLE) on a diatomaceous earth support (requiring the use of small amounts of organic solvent), followed by chromatographic separation on a C18 column and gradient elution were employed. The method quantifies...
-
MICROCOMPASS FOR SAFE SEA NAVIGATION
PublikacjaThis paper presents the results of design microcompass for safe sea navigation where navigation, electronic, programming knowledge was joined to make more safe sea navigation. In first part of article presents navigation tools which using in practise. Article underlines that mostly satellite system is used to make navigation, but recommends traditional navigation method like alternative to determinate position in case of breakdown...
-
Application of probabilistic tools to extend load test design of bridges prior to opening
PublikacjaLoad tests of bridges are widely performed in a large number of countries. Deterministic comparison of measurement results to the theoretical, FEM (finite element method)-based outcomes with possible further calibration is mostly applied. Sometimes, the data collected in the tests are also used to calibrate the reliability factors of bridge structures or their components. This work proposes to complement the stage of the load test...
-
Processing data on sea bottom structure obtained by means of the parametric sounding
PublikacjaThe aim of the paper is to analyze data obtain during sounding of the Gdansk Bay by means of the parametric sonar. The accuracy of the sea bottom structure investigation needs the correct configuration of research equipment and the proper calibration of peripheral devices (GPS, heading sensor, motion sensor MRU-Z and navigation units) which provide necessary data to bathymetrical measurement system enabling its work with whole...
-
Processing data on sea bottom structure obtained by means of the parametric sounding
PublikacjaThe aim of the paper is to analyze data obtained during sounding the Gdansk Bay sea bed by means of the parametric echo-sounder. The accuracy of the sea bottom structure investigation needs correct configuration of research equipment and proper calibration of peripheral devices (GPS, heading sensor, MRU-Z motion sensor and navigation instruments which provide necessary data to bathymetrical measurement system, enabling its work...
-
Utilizing pulse dynamics for non-invasive Raman spectroscopy of blood analytes
PublikacjaNon-invasive measurement methods offer great benefits in the field of medical diagnostics with molecular-specific techniques such as Raman spectroscopy which is increasingly being used for quantitative measurements of tissue biochemistry in vivo. However, some important challenges still remain for label-free optical spectroscopy to be incorporated into the clinical laboratory for routine testing. In particular, non-analyte-specific...
-
Instrumental measurement of odour nuisance in city agglomeration using electronic nose
PublikacjaThe paper describes an operation principle of odour nuisance monitoring network in a city agglomeration. Moreover, it presents the results of investigation on ambient air quality with respect to odour obtained during six-month period. The investigation was carried out using a network comprised of six prototypes of electronic nose and Nasal Ranger field olfactometers employed as a reference method. The monitoring network consisted...
-
Colvolutional calibration of AFM probe
Dane BadawczeAtomic force microscopy is based on the interaction of the examined surface with a probe of a pyramidal shape, tipped with a sharp end with a radius of curvature ranging from single nanometers to hundreds of nanometers. The resolution of the obtained image is of course dependent on the above-mentioned geometric size, and the resulting image is a convolutional...
-
The shallow sea experiment with usage of linear hydrophone array
PublikacjaPurpose of this article is to present designed and made linear hydrophone array and the results obtained during in situ trails on Gulf of Gdańsk. The measuring system allowed to localize hydrophones in the selected points and perform measurements in both the horizontal antenna positioning and vertical. Made in this way recordings allow creating accurate 3D imaging of sound intensity/propagation. During research three floating objects...
-
Development of an Advanced Control Algorithm for DAB DC/DC Converters: Inrush Current Limitation and Enhanced Operation in Transient States.
PublikacjaThe publication addresses the dynamic state challenges encountered during development of a dual active bridge (DAB) converter within DC microgrid systems. The conventional startup method is identified as instigating a cascade of unfavorable outcomes, encompassing elevated starting current, transformer current asymmetry, DC voltage distortions, EMI and heightened thermal stress on semiconductor components. Additionally, it necessitates...
-
In-tube extraction for the determination of the main volatile compounds in Physalis peruviana L
PublikacjaAn analytical procedure based on in-tube extraction followed by gas chromatography with mass spectrometry has been developed for the analysis of 24 main volatile components in cape gooseberry (Physalis peruviana L.) samples. According to their chemical structure, the compounds were organized into different groups: one hydrocarbon, one aldehyde, four alcohols, four esters, and 14 monoterpenes. By single-factor experiments, incubation...
-
Novel liquid chromatography method based on linear weighted regression for the fast determination of isoprostane isomers in plasma samples using sensitive tandem mass spectrometry detection
PublikacjaA simple, fast, sensitive and accurate methodology based on a LLE followed by liquid chromatography–tandem mass spectrometry for simultaneous determination of four regioisomers (8-iso prostaglandin F2α, 8-iso-15(R)-prostaglandin F2α, 11β-prostaglandin F2α, 15(R)-prostaglandin F2α) in routine analysis of human plasma samples was developed. Isoprostanes are stable products of arachidonic acid peroxidation and are regarded as the...
-
Determination of Selected Metals in Fruit Wines by Spectroscopic Techniques
PublikacjaThe determination of metals in different types of food and beverages samples has drawn significant attention due to several reasons with the most important one being the nutritional and toxic effects of these elements or their compounds. The knowledge of certain elements content in wines/fruit wines is of special interest due to their toxicity in case of excessive intake and also the effect they seem to have on the organoleptic...
-
Solid phase microextraction: state of the art, opportunities and applications
PublikacjaSolid phase microextraction is one of the most popular green techniques used for sample preparations in analytical chemistry. It is a simple, rapid, sensitive, and solvent-free technique. Since SPME was first introduced in the early 1990s, there has been an intensification of research in order to elaborate new methodical solutions in many research facilities around the world, which could increase the use of this technique. More...
-
In situ study of a composition of outlet gases from biogas fuelled Solid Oxide Fuel Cell performed by the Fourier Transform Infrared Spectroscopy
PublikacjaThe purpose of this study was to develop a method and software based on the Fourier Transform Infrared Spectroscopy for the in-situ, quantitative analysis of the composition of outlet gases from Solid Oxide Fuel Cell (SOFC). The calibration procedure performed at the beginning of the experiment indicated a polynomial dependence between the concentration of a calibrating gas (CO, CO2, CH4) and the corresponding integrated absorbance in...
-
Development of a liquid chromatography–tandem mass spectrometryprocedure for determination of endocrine disrupting compounds infish from Mediterranean rivers
PublikacjaA new, sensitive and rapid method based on QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe)approach followed by ultra high performance liquid chromatography coupled with tandem mass spec-trometry (UHPLC–MS/MS) was developed for the determination of nineteen endocrine disruptors (EDCs)and related compounds belonging to different classes in various fish species. Matrix effect on the analyti-cal performance was evaluated,...
-
Surveillance camera tracking of GEO positioned objects
PublikacjaRozdział opisuje system sterowania kamerami ruchomymi PTZ realizujący śledzenie poruszającego się obiektu o znanej pozycji GPS. Przedstawione są idea systemu oraz możliwości jego wykorzystania. Opisane są: procedura kalibracji pola widzenia kamery i sposób powiązania z danymi o lokalizacji, procedura predykcji ruchu w celu kompensacji opóźnień czasowych. Omówiony jest zaimplementowany system modułowy, w którego skład wchodzą: terminale...
-
Direction of Arrival Estimation Based on Received Signal Strength Using Two-Row Electronically Steerable Parasitic Array Radiator Antenna
PublikacjaIn this paper, we present a novel approach to direction-of-arrival (DoA) estimation using two-row electronically steerable parasitic array radiator (ESPAR) antenna which has 12 passive elements and allows for elevation and azimuth beam switching using a simple microcontroller, relying solely on received signal strength (RSS) values measured at the antenna output port. To this end, we thoroughly investigate all 18 available 3D antenna...
-
Investigation method of large-volume tire with mobile test rig
PublikacjaThe goal of this research is to develop the tire test method and mobile tire test rig. The test rig enables measurement of tire properties as stiffness and viscous damping in vertical direction, and tire–ground characteristics on the asphalt rigid surface. The tire-ground characteristics are measured by force and a torque measurement hub. The design, calibration and the algorithm for calculating the forces in the wheel center are...
-
Multi-layered tissue head phantoms for noninvasive optical diagnostics
PublikacjaExtensive research in the area of optical sensing for medical diagnostics requires development of tissue phantoms with optical properties similar to those of living human tissues. Development and improvement of in vivo optical measurement systems requires the use of stable tissue phantoms with known characteristics, which are mainly used for calibration of such systems and testing their performance over time. Optical and mechanical...