Filters
total: 1586
filtered: 1344
-
Catalog
Chosen catalog filters
displaying 1000 best results Help
Search results for: MICROWAVE PLANAR SENSOR
-
Design of a Cellular Dual-Band Sticker Antenna for Thickness-Independent 3D-Printed Substrates
PublicationAdditive manufacturing technology provides high flexibility in designing custom enclosures for prototype devices such as nodes of distributed sensor networks. Although integration of components is desired from the perspective of sensor mobility, it might negatively affect the performance of radio-connectivity due to couplings between the antenna and system peripherals, as well as other unaccounted effects of the 3D printed enclosure....
-
Acoustic imaging of selected areas of Gdansk Bay with the aid of parametric echosounder and side-scan sonar
PublicationThe article presents and analyses the data recorded during sounding of the Gdansk Bay seabed with the aid of a parametric echosounder and a side-scan sonar. The accuracy of seabed structure examination, as a condition for obtaining valuable results, requires correct configuration of echolocation devices and proper calibration of peripheral devices, such as the survey unit geographical position sensor – GPS, the navigation unit,...
-
On deterministic procedures for low-cost multi-objective design optimization of miniaturized impedance matching transformers
PublicationPurpose This paper aims to investigate deterministic strategies for low-cost multi-objective design optimization of compact microwave structures, specifically, impedance matching transformers. The considered methods involve surrogate modeling techniques and variable-fidelity electromagnetic (EM) simulations. In contrary to majority of conventional approaches, they do not rely on population-based metaheuristics, which permit lowering...
-
Impedance-based sensing of the interlayer adhesion loss in organic coating systems.
PublicationZmienne parametry środowiska takie jak: temperatura,wilgotność i promieniowanie UV powodują degradację własności ochronnych powłok organicznych. Stosując sensor w postaci elektrod wykonanych z prądoprzewodzącego tuszu umieszczonych pomiędzy warstwami zestawu oraz technikę spektroskopii impedancyjnej stwierdzono możliwość monitorowania utraty adhezji międzywarstwowej.
-
Designing a high-sensitivity dual-band nano-biosensor based on petahertz MTMs to provide a perfect absorber for early-stage non-melanoma skin cancer diagnostic
PublicationThe purpose of this study is development of a novel high-performance low-Petahertz (PHz) biosensor for non-melanoma skin cancer (NMSC) diagnosis. The presented device is designed to work within a microwave imaging regime, which is a promising alternative to conventional diagnostic methods such as visual examination, dermoscopy, and biopsy. The suggested biosensor incorporates a dual-band perfect absorber (operating bands at 0.909...
-
Recent Advances in Performance-Driven Surrogate Modeling of High-Frequency Structures
PublicationDesign of high‐frequency structures, including microwave and antenna components, heavily relies on full‐wave electromagnetic (EM) simulation models. Their reliability comes at a price of a considerable computational cost. This may lead to practical issues whenever numerous EM analyses are to be executed, e.g., in the case of parametric optimization. The difficulties entailed by massive simulations may be mitigated by the use of...
-
Seeding enhancement for microcrystaline diamond layers growth on non-diamond substrates
PublicationThe present paper gives an overview on the possible methods of seeding substrates for diamond layers growth. Diamond in reason of his properties is very desirable material in microelectronic, biomedical and waste treatment sensors. Microcrystalline diamond for these applications must be grown on silicon substrate in microwave plasma assisted chemical vapor deposition (MPACVD). To grow diamond on non-diamond surface pre-growth...
-
Energy efficient beam control for 5G antennas
PublicationThe rapid development of 5G and beyond systems demands improvement in communication speed, latency and safety to maintain the required quality of service. This paper presents an overview of different concepts of energy-efficient antenna systems, which offer beam-shaping and beam-steering functionalities, that enhance connectivity performance and can be used in 5G applications. Different designs for 5.9 GHz, 39 GHz and 60 GHz frequency...
-
Magnetoacoustic Heating of Plasma Caused by Periodic MagnetosoundPerturbations with Discontinuities in a Quasi-Isentropic Magnetic Gas
PublicationThe magnetoacoustic heating of plasma by harmonic or periodic saw-tooth perturbations at a trans-ducer is theoretically studied. The planar fast and slow magnetosound waves are considered. The wavevector may form an arbitrary angleθwith the equilibrium straight magnetic field. In view of variableθand plasma-β, the description of magnetosound perturbations and appropriate magnetosound heatingis fairly difficult. The scenario of...
-
Efficiency of exciton splitting in organic photovoltaic cells within EQE spectrum
PublicationThe paper presents a procedure of estimating the efficiency of exciton splitting at ED/EA interface. The procedure consists in evaluation of splitting of excitons into electron-hole pairs on the basis of the external quantum efficiency spectra of planar cells and spectra of absorbance of active organic layers. The fitting parameters are the exciton splitting probabilities at ED/EA interface. The presented procedure was applied...
-
Low-fidelity model considerations for simulation-based optimisation of miniaturised wideband antennas
PublicationHere, variable-fidelity electromagnetic (EM)-based design optimisation of miniaturised antennas is discussed. The authors focus on an appropriate selection of discretisation density of the low-fidelity EM model, which results in good performance of the optimisation algorithm in terms of its computational complexity and reliability. Trust-region gradient search with low-fidelity model corrected by means of non-linear frequency scaling...
-
Linear Pantographic Sheets: Existence and Uniqueness of Weak Solutions
Publicationwe address the well-posedness of the planar linearized equilibrium problem for homogenized pantographic lattices. To do so: (i) we introduce a class of subsets of anisotropic Sobolev’s space as the most suitable energy space E relative to assigned boundary conditions; (ii) we prove that the considered strain energy density is coercive and positive definite in E ; (iii) we prove that the set of placements for which the strain...
-
Gas chromatography-olfactometry (GC-O), electronic noses (e-noses) and electronic tongues (e-tongues) for in vivo food flavour measurement
PublicationThe capter revies two types of artificial olfaction instrumentation, i.e. gas-chromatography-olfactometry (GC-O) and chemical sensor technologies (electronic nose and tongue), combined with multivariate data processing methods as promising approaches for rapid analysis of food. The chapter also includes examples of specific applications for the detection of food flavour and volatile components.
-
Optoelektroniczne sensory fluorescencyjne dla monitoringu zanieczyszczeń środowiska
Publicationw pracy zaproponowano i opisano optoelektroniczny fluorescencyjny sensor do pomiaru stężenia kobaltu w wodzie. opisano zasadę działania tego typu sensorów. zaproponowano konfigurację laboratoryjnego stanowiska pomiarowego i przeprowadzono dobór niektórych jego komponentów. przedstawiono także etapy dalszych prac badawczych nad konstrukcją sensora.
-
Simple Measurement Method for Resistive Sensors Based on ADCs of Microcontrollers
PublicationA new, complete measurement method for resistance measurement of resistive sensors for systems based on microcontrollers equipped with analog-to-digital converters (ADCs) is proposed. The interface circuit consists of only four resistors, including a resistive sensor and a reference resistor, connected directly to the microcontroller pins. It is activated only during measurements, which significantly reduces power consumption....
-
A Simple Neural Network for Collision Detection of Collaborative Robots
PublicationDue to the epidemic threat, more and more companies decide to automate their production lines. Given the lack of adequate security or space, in most cases, such companies cannot use classic production robots. The solution to this problem is the use of collaborative robots (cobots). However, the required equipment (force sensors) or alternative methods of detecting a threat to humans are usually quite expensive. The article presents...
-
UV-assisted fluctuation-enhanced gas sensing by ink-printed MoS2 devices
PublicationIn this work, MoS2 flakes were printed on ceramic substrates and investigated toward 1–10 ppm of nitrogen dioxide (NO2), 2–12 ppm of ammonia (NH3), and 2–12 ppm acetone (C3H6O) under UV light (275 nm). The structure of overlapping MoS2 flakes and UV light assistance affected high responsivity to NO2 when DC resistance was monitored, and superior sensitivity to NH3 was obtained from the low-frequency noise spectra. MoS2 exhibited...
-
Functional fluorine-doped tin oxide coating for opto-electrochemical label-free biosensors
PublicationSensors operating in multiple domains, such as optical and electrochemical, offer properties making biosensing more effective than those working in a single domain. To combine such domains in one sensing device, materials offering a certain set of properties are required. Fluorine-doped tin oxide (FTO) thin film is discussed in this work as functional optically for guiding lossy modes and simultaneously electrochemically, i.e....
-
Comparison of Compact Reduced Basis Method with Different Model Order Reduction Techniques
PublicationDifferent strategies suitable to compare the performance of different model order reduction techniques for fast frequency sweep in finite element analysis in Electromagnetics are proposed and studied in this work. A Frobenius norm error measure is used to describe how good job a reduced-order model is doing with respect to the true system response. In addition, the transfer function correct behavior is monitored by studying the...
-
Factors causing degradation of sulfadimetoxine
PublicationSulfadimetoxine is a representative of sulfonamide drugs which presence inhibits growth of activated sludge bacteria, rhat is necessary for the effective mineralization of organic and inorganic contaminants. Therefore factors which con prevent this situation are searched. Aim of this study is selection of conditions causing efficien degradation of the drug- sulfadimetoxine. The impact of such aspects as : the type of oxidizing...
-
Calix[4]arenes appended with thioamide moieties as powerful tool for heavy metals recognition
PublicationSelectivity of new thioamide derivatives was assessed using those ligands as sensor materials in ion-selective membrane electrodes and tested towards Pb2+ - selectivity. The influence of the nature of the thioamide function (linear, branched or cyclic substituents) on their ionophoric properties was investigated. Electrodes based on cyclic thioamide moieties are promising analytical tools for monitoring Pb2+ concentration in natural...
-
Optimization of Polycrystalline CVD Diamond Seeding with the Use of sp³/sp² Raman Band Ratio
PublicationThe influence of various nanodiamond colloids used for seeding nondiamond substrates in microwave plasma enhanced chemical vapour deposition diamond process was investigated. Colloids based on deionized water, isopropanol alcohol and dimethyl sulfoxide (DMSO) were used with different grain size dispersion: 150, 400 and 35 nm, respectively. The influence of growth time was also taken into consideration and bias enhanced nucleation....
-
Direct amination of boron-doped diamond by plasma polymerized allylamine film
PublicationA novel microwave pulsed-plasma based method for the modification of the hydrogen-terminated polycrystalline boron-doped diamond (BDD) with a thin film of polymerized allylamine (PPAAm) is reported. A modified BDD surface is resistant to hydrolysis and delamination and is characterized by a high density of positively charged amino groups. Pulsed microwave plasma was applied to improve the degree of cross-linking and bonding of...
-
UWB Microstrip Antennas on a Cylindrical Surfaces
PublicationConformal antennas are becoming popular due to their many advantages and possibilities of applications they offer. The advantages of using antennas with a curved surface arise not only from the possibility of integrating them with the object on which they are mounted on but also from the increase, relatively to planar antennas, of their visible angular range. The circular antenna arrays, or arrays of radiators located on the surface...
-
RECENT ADVANCES IN GRAPHENE APPLICATION FOR ELECTRONIC SENSING
PublicationThe great interest in graphene is caused by its potential for constructing various sensors exhibiting excellent parameters. The high carrier mobility and the unique band structure of graphene makes it promising especially in the field-effect transistors (GFET) applications. In this article, recent advances of the selected graphene-based sensor applications were presented and the possible directions for further investigations were...
-
Low-power device simulator for micro-energy measurement methods testing
PublicationThe paper presents low-power device simulator designed for testing of micro-energy measurement methods. Such kind methods can be used for evaluation of power systems based on Energy Harvesting. The device allows to set the current consumption characteristic over the time, thus making possible playing the role of different types of low-power devices e.g. simulating sensor network node.
-
Compensation of magnetic disturbances caused by sensors in a differential magnetometric system
PublicationStudy of low magnetic fields necessitates the use of precision magnetometers working in a differential system. Minimization of this error is a substantial issue in the case of magnetometers working in a differential system on a mobile platform. The compensation method of heading error consists in taking measurements of changes in magnetic induction with the use of the tested magnetometer for various locations of the sensor in relation...
-
Enhanced visible light-activated gas sensing properties of nanoporous copper oxide thin films
PublicationMetal oxide gas sensors are popular chemoresistive sensors. They are used for numerous tasks, including environmental and safety monitoring. Some gas-sensing materials exhibit photo-induced properties that can be utilized for enhanced gas detection by modifying the sensor selectivity and sensitivity when illuminated by light. Here, we present the gas sensing characteristics of highly nanoporous Cu2O thin films towards both electrophilic...
-
Non-Gaussian Resistance Fluctuations in Gold-Nanoparticle-Based Gas Sensors: An Appraisal of Different Evaluation Techniques
PublicationVolatile organic compounds, such as formaldehyde, can be used as biomarkers in human exhaled breath in order to non-invasively detect various diseases, and the same compounds are of much interest also in the context of environmental monitoring and protection. Here, we report on a recently-developed gas sensor, based on surface-functionalized gold nanoparticles, which is able to generate voltage noise with a distinctly non-Gaussian...
-
Predictions of cervical cancer identification by photonic method combined with machine learning
PublicationCervical cancer is one of the most commonly appearing cancers, which early diagnosis is of greatest importance. Unfortunately, many diagnoses are based on subjective opinions of doctors—to date, there is no general measurement method with a calibrated standard. The problem can be solved with the measurement system being a fusion of an optoelectronic sensor and machine learning algorithm to provide reliable assistance for doctors...
-
Long-working-distance Raman system for monitoring of uPA ECR CVD process of thin diamond/DLC layers growth
PublicationW artykule przedstawiono konstrucję systemu optoelektronicznego do monitoringu ramanowskiego in-situ procesu μPA ECR CVD (ang.: Microwave Plasma Assisted Electron Cyclotron Resonance Chemical Vapour Deposition), stosowanego do osadzania cienkich warstw diamentowych i diamentopodobnych DLC. System ma budowę modułową i wyposażony jest w dedykowane sondy optyczne. Przedstawiono wyniki pomiarów testowych, potwierdzjące, że system posiada...
-
The Quick Measure of a Nurbs Surface Curvature for Accurate Triangular Meshing
PublicationNURBS surfaces are the most widely used surfaces for three-dimensional models in CAD/CAE programs. As a model for FEM calculation is prepared with a CAD program it is inevitable to mesh it finally. There are many algorithms for meshing planar regions. Some of them may be used for meshing surfaces but it is necessary to take the curvature of the surface under consideration to avoid poor quality mesh. The mesh must be denser in the...
-
TR-Based Antenna Design with Forward FD: The Effects of Step Size on the Optimization Performance
PublicationNumerical methods are important tools for design of modern antennas. Trust-region (TR) methods coupled with data-efficient surrogates based on finite differentiation (FD) represent a popular class of antenna design algorithms. However, TR performance is subject to FD setup, which is normally determined a priori based on rules-of-thumb. In this work, the effect of FD perturbations on the performance of TR-based design is evaluated...
-
Reactivity of bulky aminophosphanes towards small molecules: Activation of dihydrogen and carbon dioxide by aminophosphane/borane frustrated Lewis pairs
PublicationA series of mono- and bisaminophosphanes with formulas R2NPR’R’’ and (R2N)2PR’ (R = iPr, Cy; R’ = Ph, Cy; R’’ = iPr) were characterized by X-ray analysis, NMR spectroscopy and computational methods. The common structural futures of these species are short and polarized PAN bonds, a pyramidal geometry at the P atom and an almost planar geometry at the N atoms. According to DFT calculations, these...
-
Mathematical model of pennate muscle
PublicationThe purpose of this study is to create a new mathematical model of pennate striated skeletal muscle. This new model describes behaviour of isolated flat pennate muscle in two dimensions (2D) by taking into account that rheological properties of muscle fibres depend on their planar arrangement. A new mathematical model is implemented in two types: 1) numerical model of unipennate muscle (unipennate model); 2) numerical model of...
-
Fabrication, Microstructure and High Temperature Corrosion Resistance of Porous Alloys for Solid Oxide Fuel Cells
PublicationPorous alloys find use in modern Solid Oxide Fuel Cells as the supporting structures. As they are exposed to high temperatures (> 500°C) an oxide scale forms on their surface due to high temperature corrosion phenomena. Since the ratio between the surface area and volume is much higher than for planar samples, formation of the oxide can lead to a breakaway oxidation after relatively short times. Therefore corrosion properties of...
-
Wide-field magnetometry using nitrogen-vacancy color centers with randomly oriented micro-diamonds
PublicationMagnetometry with nitrogen-vacancy (NV) color centers in diamond has gained significant interest among researchers in recent years. Absolute knowledge of the three-dimensional orientation of the magnetic field is necessary for many applications. Conventional magnetometry measurements are usually performed with NV ensembles in a bulk diamond with a thin NV layer or a scanning probe in the form of a diamond tip, which requires a...
-
Compact 4 × 4 butler matrix with non‐standard phase differences for IoT applications
PublicationButler matrices represent a popular class of feeding networks for antenna arrays. Large dimensions and the lack of flexibility in terms of achievable output phase difference make conventional Butler structures of limited use for modern communication devices. In this work, a compact planar 4 × 4 matrix with non-standard relative phase shifts of –30º, 150º, –120º, and 60º has been proposed. The structure is designed to operate at...
-
Decomposition of Acoustic and Entropy Modes in a Non-Isothermal Gas Affected by a Mass Force
PublicationDiagnostics and decomposition of atmospheric disturbances in a planar flow are considered in this work. The study examines a situation in which the stationary equilibrium temperature of a gas may depend on the vertical coordinate due to external forces. The relations connecting perturbations are analytically established. These perturbations specify acoustic and entropy modes in an arbitrary stratified gas affected by a constant...
-
The use of liquid crystal thermography TLC and particle image velocimetry PIV in selected technical applications
PublicationNowadays, the energy cost is very high and this problem is carried out to seek techniques for improvement of the aerothermal and thermal (heat flow) systems performances in different technical applications. The transient and steady-state techniques with liquid crystals for the surface temperature and heat transfer coefficient or Nusselt number distribution measurements have been developed. The flow pattern produced by transverse...
-
Rapid antenna design optimization using shape-preserving response prediction
PublicationAn approach to rapid optimization of antennas using the shape-preserving response-prediction (SPRP) technique and coarsediscretization electromagnetic (EM) simulations (as a low-fidelity model) is presented. SPRP allows us to estimate the response of the high-fidelity EM antenna model, e.g., its reflection coefficient versus frequency, using the properly selected set of so-called characteristic points of the low-fidelity model...
-
Interlayer defect evolution in an coating system on steel under hydromechanical loading
PublicationZaprezentowano wyniki pomiarów impedancyjnych obszaru międzywarstwowego w systemie powłokowym poddanym naprężeniom. Przedstawiono nowy sensor który jest zdolny do detekcji defektów w obszarze międzywarstwowym. Dwuwarstwowy system powłokowy przeznacziony do zastosowań morskich zbadano w celu określenia jego odporności na oddziaływanie cyklicznych naprężeń i zanurzeń w 3% roztworze NaCl.
-
Research of hydrotronic variable displacement radial piston pump with electro -pneumatic control
PublicationThe paper presents the developed new electro-pneumatic control (pneumotronic) system for hydraulic fixed-displacement radial piston pump. Hydraulic fixed-displacement radial piston pump equipped with the proposed control system changes into hydrotronic variable-displacement radial piston pump. Pump flow rate control is realized by means of programmable logic controller, electro-pneumatic valves, pneumatic cylinders and a sensor.
-
Chemiresistive gas sensors based on carbon nanotubes - fabrication and application
PublicationMany types of sensors have been invented to identify and quantify chemical contamination in the gas phase. Sensors based on carbon nanotubes are particularly attractive because of their wide range of applicaions and potential use in electronic nose that can be controlled using algorithms of Artificial Intelligence. Sensor functions, fabrication and selected applications are reviewed and discussed with focus on chemiresistors. Drawbacks...
-
Novel proposal for V2X systems and WBAN cooperation to improve road safety
PublicationIn this paper, a novel proposal of the automotive Vehicle-to-Everything system solution is presented. In this proposal, there are included the Machine to Machine type communication system and the sensor system based on a short-range the Wireless Body Area Network communication. The aim of this paper is the analysis of the model for communication, especially its architecture and signals structure for the proposed solution. The use...
-
Sensors for Rapid Detection of Environmental Toxicity in Blood of Poisoned People
PublicationRecently, the diagnosis and treatment of poisoned person can be done only in specialized centers. Furthermore, currently used clinical methods of intoxication diagnosis are not sufficient for early detection. Conventional laboratory tests based on urine and blood require professional, high skilled staff, high cost equipment as well as they are arduous and lasting analytical procedures. There is a need to elaborate relatively cheap...
-
The Concept of Accuracy Analysis of the Vertical Displacements Gained from the Hydrostatic Levelling Systems’ Measurements
PublicationAbstract: Nowadays, hydrostatic levelling is a widely used method for the vertical displacements’ determinations of objects such as bridges, viaducts, wharfs, tunnels, high buildings, historical buildings, special engineering objects (e.g., synchrotron), sports and entertainment halls. The measurements’ sensors implemented in the hydrostatic levelling systems (HLSs) consist of the reference sensor (RS) and sensors located on the...
-
СИСТЕМА КОНТРОЛЯ СОСТОЯНИЯ ИЗОЛЯЦИИ ЭЛЕКТРОПРИВОДОВ В СЕТЯХ С ГЛУХОЗАЗЕМЛЕННОЙ НЕЙТРАЛЬЮ (System of insulation status monitoring for electric drives in networks with a dead-earth neutral)
PublicationПредложен метод контроля изоляции частотно-регулируемых электроприводов в сетях с глухозаземленной нейтралью. Система контроля изоляции включается в момент остановки электропривода. Ключи инвертора коммутируются по специальному закону, и с помощью сигнала трансформатора тока, который изме- ряет ток во всех трех фазах привода одновременно, определяется ток утечки. Рассмотрена схема датчика тока утечки и приведены экспериментальные...
-
Embedded system using Bluetooth Low Energy sensors for smart farming applications
PublicationThe main goal of this Bachelor of Engineering project titled Embedded system using Bluetooth Low Energy sensors for smart farming applications is to create a prototype of a system consistent with Agriculture 4.0 concept using Bluetooth Low Energy (BLE) technology. Developed solution shall be easy in implementation and its main functionality shall be periodic gathering of data from environmental sensors...
-
Magnetic disturbances caused by magnetic contamination of plastics
PublicationIn the study of low magnetic fields precision magnetometers working in a differential system are used. Two optically pumped magnetometers working in a differential system allow for precise measuring of disturbances in the magnetic field. In order to attain high accuracy of magnetic field measurement, it is necessary to use appropriate materials for the construction of a magnetometric system, particularly of those located closely...