displaying 1000 best results Help
Search results for: ion-selective electrodes · multisensor system · potenctiometric measurements · reference electrode
-
Multi-Walled Carbon Nanotubes and Copper Oxide Nanoparticles Composite Used as Transducer Medias in Nitrate Ion-Selective Electrodes
Publication -
In-situ and ex-situ resistance measurements of polypyrrole film using double-band electrode
PublicationMany in-situ techniques are performed in order to determine the resistance of conducting polymer film. However, the resistance measured in solution can be the combination of polymer resistance and that of other components, such as resistance of supporting electrolyte. Therefore, in this work, the influence of the solution on the resistance of polypyrrole (PPy) film has been studied. PPy film was electrchemically synthesized onto...
-
Certified Reference Material - as a necessary tool for the quality control and quality assurance of measurements
PublicationReference materials are necessary to control and ensure the quality of the measurements. The demand for analytical information on the composition of different material objects makes it necessary to produce an even wider range of materials.
-
Advanced Lithium-Ion Battery Model for Power System Performance Analysis
PublicationThe paper describes a novel approach in battery storage system modelling. Different types of lithium-ion batteries exhibit differences in performance due to the battery anode and cathode materials being the determining factors in the storage system performance. Because of this, the influence of model parameters on the model accuracy can be different for different battery types. These models are used in battery management system...
-
Designing high-performance asymmetric and hybrid energy devices via merging supercapacitive/pseudopcapacitive and Li-ion battery type electrodes
PublicationWe report a strategic development of asymmetric (supercapacitive–pseudocapacitive) and hybrid (supercapacitive/pseudocapacitive–battery) energy device architectures as generation–II electrochemical energy systems. We derived performance-potential estimation regarding the specific power, specific energy, and fast charge–discharge cyclic capability. Among the conceived group, pseudocapacitor–battery hybrid device is constructed with...
-
Automatic system for optical parameters measurements of biological tissues
PublicationIn this paper a system allowing execution of automatic measurements of optical parameters of scattering materials in an efficient and accurate manner is proposed and described. The system is designed especially for measurements of biological tissues including phantoms, which closely imitate optical characteristics of real tissue. The system has modular construction and is based on the ISEL system, luminance and color meter and...
-
Accuracy Analysis of Determination the Vertical Displacements in Unstable Reference System
PublicationMeasurements of horizontal and vertical displacements are carried out mostly based on reference points identified as fixed. In surveying practice there may be some situations in which there is not possible to perform the measurements with reference to stable points or the difficulties in identification of points’ stability may arise. Accuracy analysis based on the covariance matrices have a special role in this process. In presented...
-
Improved Lead Sensing Using a Solid-Contact Ion-Selective Electrode with Polymeric Membrane Modified with Carbon Nanofibers and Ionic Liquid Nanocomposite
Publication -
Reference FEM model for SHM system of cable-stayed bridge in Rzeszów
PublicationThe paper presents the references model for structural health monitoring system (SHM) of cable-stayed bridge recently constructed in Rzeszów over Wisłok River. The SHM system is design to provide on-line information on the structure state and facilitate its maintenance procedures. The main feature of the SHM system is permanent observation of the dynamic behavior of the bridge with focus on cable vibrations. The paper discusses...
-
The Use of Free Adjustment and Msplit-Estimation for Determination of the Vertical Displacements in Unstable Reference System
PublicationThe problem of the determining of the displacements of engineering objects and their surroundings is the current and important issue in the field of engineering geodesy. Most control measurements are made in relation to reference points (stable points). On the other hand, sometimes it happens that it is not possible perform the measurements with reference to the stable points or identification of stable points is difficult. Therefore,...
-
Studies on 16-membered azothia-and azoxythiacrown ethers as ion carriers in ion selective membranes.
Publication16-członowe azo iazoksy korony zawierające w makropierścieniu atomy siarki były badane jako nośniki jonów w jonoselektywnych elektrodach membranowych. Związki te badane były pod kątem kompleksowania metali I i II grupy układu okresowego oraz metali ciężkich i przejściowych. Wyznaczone zostały stałe trwałości kompleksów azokoron z wybranymi kationami za pomocą metody sandwiczowej. W wyniku badań potwierdzono tworzenie się silnych...
-
Ionophores in polymeric membranes for selective ion recognition:impedance studies
PublicationW pracy badano dwa typy elektrod: membranowe elektrody jonoselektywne (ISE) oraz elektrody nowego typu all-solid-state (AAS). Elektrody AAS zawierają przewodzącą warstwę polimerową na węglu szklistym lub platynie, na który nałożona jest membrana zawierająca jonofor. Do badań użyto dwa jonofory: p-tert-butylokaliks[4]aren-korona-4 (L1) selektywnie kompleksująca jony Na+ oraz kaliks[4]aren-korona-6 (L2) selektywnie kompleksująca...
-
Tin oxide nanoparticles from laser ablation encapsulated in a carbonaceous matrix – a negative electrode in lithium-ion battery applications
PublicationThis report concerns carbonaceous electrodes doped with tin(II) oxide nanoparticles. Tin nanoparticles are obtained by pulsed laser ablation in water. Crystalline nanoparticles have been encapsulated in a carbonaceous matrix formed after pyrolysis of a mixture consisting of tin/tin(IV) oxide nanoparticles and gelatine. The obtained material is characterized by means of X-ray diffraction, selected area diffraction, scanning electron...
-
Paweł Możejko dr hab.
People -
New Materials Used for the Development of Anion-Selective Electrodes—A Review
Publication -
Multifrequency Nanoscale Impedance Microscopy (m-NIM): A novel approach towards detection of selective and subtle modifications on the surface of polycrystalline boron-doped diamond electrodes
PublicationIn this paper, we describe the modification of Nanoscale Impedance Microscopy (NIM), namely, a combination of contact-mode atomic force microscopy with local impedance measurements. The postulated approach is based on the application of multifrequency voltage perturbation instead of standard frequency-by-frequency analysis, which among others offers more time-efficient and accurate determination of the resultant impedance spectra...
-
Study of oxygen electrode reactions on symmetrical porous SrTi0.30Fe0.70O3-δ electrodes on Ce0.8Gd0.2O1.9 electrolyte at 800 °C–500 °C
PublicationIron doped strontium titanates (SrTi1-xFexO3-δ) are an interesting mixed ionic-electronic conductor model used to study basic oxygen reduction/oxidation reactions. In this work, we performed an impedance spectroscopy study on symmetrical porous SrTi0.30Fe0.70O3-δ (STF70) electrodes on a ceriabased electrolyte. The sample was measured in varying oxygen concentration: from 0.3% to 100% in 800 °C - 500 °C temperature range. Low polarisation...
-
Ionophores in polymeric membranes for selective ion recognition; impedance studies
PublicationBadania impedancyjne membran zawierających jonofory selektywne na kation Na+ (L1) i Cs+(L2) wykazały, ze stala dielektryczna materiału membrany zależy od typu uzytego plastyfikatora i zmienia się w zakresie od 28 do 60. Rezystancja membran zawierających ligand L1 i L2 wynosi 0.15 -1.4 Mohm w zależności od stężenia elektrolitu zewnnetrznego. Testowona dwa typy elektrod jonoselektywnych: elektrody typu ASS z polimerem przewodzącym...
-
Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes
PublicationIn this article a novel method of positional data integration in an indoor hybrid localization system combining inertial navigation with radio distance measurements is presented. A point of interest is the situation when the positional data and the radio distance measurements are obtained from less than thee reference nodes and it is impossible to unambiguously localize the moving person due to undetermined set of positional equations....
-
Highly selective impedimetric determination of Haemophilus influenzae protein D using maze-like boron-doped carbon nanowall electrodes
PublicationThis study reports a novel impedimetric immunosensor for protein D detection in purified and bacterial (Haemophilus influenzae, Hi) samples. The detection was based on antigen recognition by anti-protein D antibodies (apD) immobilised at the maze-like boron-doped carbon nanowall electrodes (B:CNW). The B:CNW electrodes were synthesised, and their surface was characterised by scanning electron microscopy (SEM) and X-ray photoelectron...
-
Diagnosis of reference electrodes in cathodic protection systems by electrochemical impedance spectroscopy
PublicationPrzedstawiono wyniki badań laboratoryjnych i terenowych przeprowadzonych techniką elektrochemicznej spektroskopii impedancyjnej (EIS). Zaprezentowano widma impedancyjne następujących układów: elektroda odniesienia/elektroda pomocnicza; rurociąg/zakopane i przenośne elektrody odniesienia. Pokazano, że omawiana technika umożliwia badanie stanu technicznego elektrod odniesienia, co zwiększa pewność wyników pomiarów potencjału chronionej...
-
Digital harmonic analysis of cadmium ion reduction on a dropping mercury electrode
PublicationBadano redukcję jonów kadmu na rtęciowej elektrodzie kroplowej. Jako pobudzenie zastosowano sinusoidalny sygnał napięciowy nałożony na liniowo zmieniający się potencjał dc. Przeprowadzono analizę czasowo-częstotliwościową prądu polarograficznego dla reakcji redukcji jonu kadmu na rtęciowej elektrodzie kroplowej. Klasyczna transformacja Fouriera prowadzi do dekompozycji prądu polarograficznego na składowe harmoniczne. Harmoniczne...
-
Nanocomposite of copper oxide nanoparticles and multi-walled carbon nanotubes as a solid contact of a copper-sensitive ion-selective electrode: intermediate layer or membrane component–comparative studies
Publication -
Michał Michna dr hab. inż.
PeopleMichal Michna received the M.Sc. and Ph.D. degrees in electrical engineering from the Gdansk University of Technology (GUT), Gdansk, Poland, in 1998 and 2005, respectively. Since 2004, he was employed at the Department of Power Electronics and Electrical Machines of the Gdańsk University of Technology (assistant, assistant professor, senior lecturer). In 2010-2015 he was a deputy of head of the Department of Power Electronics and...
-
Automated Generation of Modular Assurance Cases with the System Assurance Reference Model
PublicationAssurance cases are structured arguments used to demonstrate specific system properties such as safety or security. They are used in many industrial sectors including automotive, aviation and medical devices. Assurance cases are usually divided into modules which address goals allocated to specific system properties, components, functions, modes of operation or environmental conditions. Depending on the system and assurance process...
-
Solid-phase microextraction and ion chromatographic analysis of anions based on polypyrrole electrode
Publication -
Transmission Quality Measurements in DAB+ Broadcast System
PublicationIn the age of digital media, delivering broadcast content to customers at an acceptable level of quality is one of the most challenging tasks. The most important factor is the efficient use of available resources, including bandwidth. An appropriate way of managing the digital multiplex is essential for both the economic and technical issues. In this paper we describe transmission quality measurements in the DAB+ broadcast system....
-
Lower rim substituted tert-Butylcalix[4]arenes. Part 13. Interaction of calix-hydroxamates with Fe(III) and Pb(II); studies in ion-selective membrane electrodes (ISE)
PublicationPrzedmiotem pracy są badania oddziaływań pomiędzy trzema wybranymi hydroksamowymi pochodnymi t-butylo-kaliks[4]arenu i jonami metali z wykorzystaniem membranowych elektrod jonoselektywnych (ISE). Elektrody zawierające jako materiał aktywny wymienione związki jonoforowe charakteryzują się nernstowskim nachyleniem i szerokim zakresem liniowości na jony Pb(II), a także dobrą selektywnością na jony Pb(II)w stosunku do jonów UO2(II),...
-
Development of the System Assurance Reference Model for Generating Modular Assurance Cases
PublicationAssurance cases are structured arguments used to demonstrate specific system properties such as safety or security. They are used in many industrial sectors including automotive, aviation and medical devices. Larger assurance cases are usually divided into modules to manage the complexity and distribute the work. Each of the modules is developed to address specific goals allocated to the specific objects i.e. components of the...
-
Pitting corrosion characterization by electrochemical noise measurements on asymmetric electrodes
PublicationKorozja wżerowa stali nierdzewnych może być wykryta za pomocą obserwacji charakterystycznych sygnałów prądowych, jakie płyną między dwiema elektrodami metalowymi. W artykule proponuje się wyznaczanie funkcji bispektrum dla układu dwóch elektrod o istotnie różnej powierzchni narażonej na występowanie korozji. Proponowana metoda została zastosowana do analizy korozji wżerowej stali 0H18N9 powstającej pod wpływem 1M roztworu FeCl3...
-
Lower Rim Substitutedp-tert-Butyl-Calix[4]arene. Part 15. Pb(II)-Ion-Selective Electrodes Based onp-tert-Butyl-calix[4]arene Thioamides
Publication -
Carbon nanotubes decorated by mesoporous cobalt oxide as electrode material for lithium-ion batteries
Publication -
Selective Synthesis of Magnetite Nanospheres with Controllable Morphologies on CNTs and Application to Lithium‐Ion Batteries
Publication -
Tracking body movement for radio channel measurements in BAN with indoor positioning system
PublicationThis paper presents indoor positioning system based on inertial navigation with additional distance measurements using UWB modems and map matching to increase accuracy and eliminate position drift. Such system may be used to track position of human body during radio channel measurements for body area networks. Performance of proposed system and limitations caused by inertial navigation are briefly described.
-
Lower Rim Substituted p-tert-Butyl-Calix[4]arene. Part 15. Pb(II)-Ion-Selective Electrodes Based on p-tert-Butyl-calix[4]arene Thioamides.
PublicationTetra podstawione tioamidowe pochodne para-tert-butylokaliks[4]arenu (1-5) zostały zastosowane jako jonofory w membranowych elektrodach jonoselektywnych (EJS) selektywne na kationy Pb(II). Wyznaczono współczynniki selektywności. Czwartorzędowe kaliks[4]aren-tioamidy (1,2) wykazują nadzwyczaj dobrą selektywność na kationy Pb(II) w porównaniu z kaliks[4]aren-amidami. Membrany z tymi ligandami wykazują dużą trwałość, a charakterystyki...
-
System setup and software for cyclic, staircase and square wave voltammetry measurements
PublicationHardware dedicated for electrochemical measurement sometimes does not allow performing certain voltammetry experiments. Staircase and square wave voltammetry, techniques which have many advantages comparing with standard voltammetric techniques, are rarely implemented in software controlling electrochemical measuring equipment. These methods, however, can be relatively easy realized with some addition...
-
Jarosław Chojnacki prof. dr hab. inż.
PeopleBorn in 1961 in Bydgoszcz, professional education started at the Chemical Technical Highschool (I. Łukasiewicz). He graduated from the Faculty of Chemistry at the Gdańsk University of Technology in 1986, defending the work on ion-selective electrodes. Subsequent studies were related to organic and siliconorganic synthesis and, from 2002 year on, to crystallography. The doctoral thesis concerned the Silanotiolanes of coinage metals...
-
Accuracy of marine gravimetric measurements in terms of geodetic coordinates of land reference benchmark
Publication -
Distributed System For Noise Threat Evaluation Based On Psychoacoustic Measurements
PublicationAn innovative system designed for the continuous monitoring of acoustic climate of urban areas was presentedin the paper. The assessment of environmental threats is performed using online data, acquired through a grid ofengineered monitoring stations collecting comprehensive information about the acoustic climate of urban areas.The grid of proposed devices provides valuable data for the purpose of long and short time acoustic climateanalysis....
-
Self-Calibrating Stress Measurement System Based on Multidirectional Barkhausen Noise Measurements
PublicationThe system presented in this paper enables automatization of the two-dimensional calibration process (determination of Barkhausen noise (BN) intensity dependence on in-plane components of strain). Then, using dedicated software created by the authors in LabVIEW environment, and with the help of two dimensional calibration data one can effectively determine strain and stress distribution i.e. magnitude and orientation of main strain/stress...
-
Selectivity of lithium electrodes: correlation with ion-ionophore complexstability constants and with interfacial exchange current densities
PublicationMembranowe elektrody selektywne na jony litu oparte na dwóch różnych dicyk-lohesyloamidowych jonoforach poddane zostały systematycznym badaniom. Potencjometrycznie wyznaczono wartości współczynników selektywności. Wartości stałych trwałości kompleksów z jonami litu, sodu i potasu wyznaczono metodą membran "sandwichowych". Transfer ładunków przez membranę oraz przez granicę faz membrana/roztwór badano metodą spektroskopii impedancyjnej....
-
A Low-Cost System for Far-Field Non-Anechoic Measurements of Antenna Performance Figures
PublicationPrototype measurements are the key step in the development of antenna structures. Typically, their far-field characteristics are validated in expensive, dedicated facilities such as open range sites, or anechoic chambers. Despite being necessary for obtaining high-precision data (e.g., for device qualification), the use of costly infrastructure might not be fully justified when the main goal of measurements includes demonstration...
-
Conventional and solid-contact lithium-selective electrodes based on tris(N,N-dicyclohexylamide) neutral ionophore
PublicationKonstruowano jonoselektywne elektrody litowe (Li-ISEs) z membraną polimerową i obojętnym jonoforem tris(N,N-dicycloheksyloamidem) jako: elektrodę konwencjonalną (z wodnym roztworem elektrolitu wewnętrznego) oraz ze stałym kontaktem (polianilina jako przekaźnik jonowo-elektronowy). Charakterystyki obu elektrod (nachylenie i zakres liniowy) są porównywalne. Badana elektroda ze stałym kontaktem wykazuje dobrą stabilność w czasie....
-
The Positioning Accuracy of BAUV Using Fusion of Data from USBL System and Movement Parameters Measurements
PublicationThe article presents a study of the accuracy of estimating the position coordinates of BAUV (Biomimetic Autonomous Underwater Vehicle) by the extended Kalman filter (EKF) method. The fusion of movement parameters measurements and position coordinates fixes was applied. The movement parameters measurements are carried out by on-board navigation devices, while the position coordinates fixes are done by the USBL (Ultra Short Base...
-
Hard carbon derived from rice husk as low cost negative electrodes in Na-ion batteries
PublicationHere, we report the synthesis of hard carbon materials (RH) made from natural rice husk through a single pyrolysis process and their application as an anode in sodium-ion batteries. The studies show that the electrochemical properties of RHs are affected by the treatment temperatures, which determine the materials morphology, in particular, their degree of graphitization and extent of continuous channels (nanovoids). The latter...
-
Calorimetric measurements of the Li Pd system
Publication -
Towards Promotion of Graphene/Titania‐Based Electrode via Ultrafast and Self‐Expansion Reduction for Li‐ion Battery
Publication -
Study on the Positioning Accuracy of the GNSS/INS System Supported by the RTK Receiver for Railway Measurements
PublicationCurrently, the primary method for determining the object coordinates is positioning using Global Navigation Satellite Systems (GNSS) supported by Inertial Navigation Systems (INS). The main goal of this solution is to ensure high positioning availability, particularly when access to satellite signals is limited (in tunnels, areas with densely concentrated buildings and in forest areas). The aim of this article is to determine whether...
-
Rafał Leszczyna dr hab. inż.
PeopleDr hab. Rafal Leszczyna is an associate professor at Gdansk University of Technology, Faculty of Management and Economics. He holds the M.Sc. degrees of Computer Science and Business Management. In December, 2006 he earned a Ph.D. in Computer Science, specialisation - Computer Security at the Faculty of Electronics, Telecommunications and Informatics of Gdansk University of Technology. Between 2004 and 2008 he worked in the European...
-
Long term measurements of PM1, PM2.5, PM10 and NO2 in open-air at Gdansk (Poland) area using low-cost sensors together with the reference results
Open Research DataThe measurements results of open-air measurements made using the following low-cost sensors: particulate matter (PM) sensor SPS30 from Sensirion, NO2 electrochemical sensor SGX-7NO2 from SGX Sensortech, NO2 electrochemical sensor 7E4-NO2 from SemaTech, compact MOS air quality sensor MiCS 2714 from SGX Sensortech, BME280 (Bosch) environmental sensor...