Filters
total: 743
filtered: 558
-
Catalog
- Publications 558 available results
- Journals 7 available results
- Conferences 1 available results
- People 12 available results
- Inventions 1 available results
- Projects 1 available results
- Research Equipment 9 available results
- e-Learning Courses 7 available results
- Open Research Data 147 available results
Chosen catalog filters
Search results for: AC adaptor
-
Modern Arrangement for Reduction of Voltage Perturbations
PublicationThe contents of this chapter encompass general problems and the most important issues of power-supply-quality improvement in AC systems. In the context of the above, consideration is given to evaluation of bilateral interactions of receivers with an electrical power-distribution system and methods of their reduction. Also are discussed the basis of operation of the most important compensation-filtration devices and their applications...
-
Application of Traction Supply System for Charging Electric Cars
PublicationThe development of electromobility involves the development of electric cars charging infrastructure. The increase of the number of chargers poses new demands for the AC power grid, especially in regard to its capacity of delivering high peak power. As an alternative for the public AC power grid, urban electrified transportation systems (trams, trolleybuses, and metro) can be used for supplying electric cars chargers. The article...
-
A measurement method for capacitive sensors based on a versatile direct sensor-to-microcontroller interface circuit
PublicationIn the paper, there is presented a new time-domain measurement method for determining the capacitance values of capacitive sensors, dedicated, among others, to capacitive relative humidity sensors. The method is based on a versatile direct sensor-to-microcontroller interface for microcontrollers with internal analog comparators (ACs) and with precision voltage reference sources, e.g. digital-to-analog converters (DACs). The reference...
-
Obserwatory prędkości dla bezczujnikowego sterowania maszynami prądu przemiennego
PublicationPrzedstawiono model matematyczny uogólnionej maszyny elektrycznej rozszerzony przez wprowadzenie dodatkowych zmiennych. Na podstawie modelu rozszerzonego opracowano strukturę obserwatora prędkości maszyny uogólnionej. Zaprezentowano struktury obserwatorów prędkości dla poszczególnych rodzajów maszyn prądu przemiennego. Pokazano, że prędkość kątową wirnika można odtwarzać dla różnych typów maszyn stosując odpowiednie zmienne stanu...
-
ANALIZA SCZEPNOŚCI MIĘDZYWARSTWOWEJ DWUWARSTWOWO WBUDOWANEJ PODBUDOWY ASFALTOWEJ NA ODCINKU KM 335+946 – 356+850 STR. P ORAZ JEJ WPŁYW NA TRWAŁOŚĆ KONSTRUKCJI NAWIERZCHNI „Budowa mostu przez rzekę Nogat w Malborku wraz z dojazdami w ciągu dróg krajowych nr 22 i 55"
PublicationCelem pracy jest ocena jakości połączenia dwóch warstw technologicznych podbudowy z betonu asfaltowego AC 22 35/50 o całkowitej grubości 18 cm oraz wpływ tego połączenia na trwałość konstrukcji nawierzchni drogi na odcinku km 355+946 – 356+850 str. P, wbudowanej w ramach realizacji kontraktu „Budowa mostu przez rzekę Nogat w Malborku wraz z dojazdami w ciągu dróg krajowych nr 22 i 55”.
-
Sensorless predictive control of three-phase parallel active filter
PublicationThe paper presents the control system of parallel active power filter (APF) with predictive reference current calculation and model based predictive current control. The novel estimator and predictor of grid emf is proposed for AC voltage sensorless operation of APF, regardless of distortion of this voltage. Proposed control system provides control of APF current with high precision and dynamics limited only by filter circuit parameters....
-
Electrical properties and structure of lead-borate glass containing iron ions.
PublicationThe ac and dc conductivity in iron–lead-borate glass samples was investigated in the frequency range from 1 mHz to 1 MHz and in the temperature range from 153 K to 423 K. The structure was investigated by the means of atomic force microscopy (AFM) and the crystalline phases (if present) were identified by the means of X-ray diffractometry. Two types of ac electrical behaviour were observed. The first group of glass samples which...
-
Field investigation of low-temperature cracking and stiffness moduli on selected roads with conventional and high modulus asphalt concrete
PublicationHigh Modulus Asphalt Concrete (HMAC) was introduced in Poland as a one of the solutions to the problem of rutting, type of deterioration common in the 1990s. After first encouraging trials in 2002 HMAC was widely used for heavily loaded national roads and motorways. However some concerns were raised about low-temperature cracking of HMAC. This was the main reason of the studies presented in this article were started. The article...
-
MODEL HYBRYDOWEGO ENERGOELEKTRONICZNEGO UKŁADU ZASILANIA WIELOSYSTEMOWYCH ZESPOŁÓW TRAKCYJNYCH (EZT)
PublicationW artykule przedstawiono model układu hybrydowego energoelektronicznego układu zasilania wielosystemowych zespołów trakcyjnych - EZT. Istota proponowanego rozwiązania zawiera się w zastosowaniu do obniżenia napięcia sieci trakcyjnej, zamiast tradycyjnego ciężkiego transformatora trakcyjnego (chłodzonego olejem) - suchego autotransformatora pracującego z częstotliwością sieci kolejowej oraz izolacji galwanicznej od sieci trakcyjnej....
-
Assessment of Electronic Sensing Techniques for the Rapid Identification of Alveolar Echinococcosis through Exhaled Breath Analysis
PublicationHere we present a proof-of-concept study showing the potential of a chemical gas sensors system to identify the patients with alveolar echinococcosis disease through exhaled breath analysis. The sensors system employed comprised an array of three commercial gas sensors and a custom gas sensor based on WO3 nanowires doped with gold nanoparticles, optimized for the measurement of common breath volatile organic compounds. The measurement...
-
Feedback Control of Doubly-Fed Generator Connected to Current Source Converter
PublicationDoubly-fed induction generator (DFIG) system supplied by current source converter (CSC) is considered in this article. The DFIG can work in two independent modes: AC grid connection and stand-alone mode. The DFIG is connected to the ac grid directly through its stator and the CSC links the rotor side. In this mode, the active and reactive powers of the DFIG must be controlled. This article proposes two control system structures...
-
Experimental test results of the 150kVA 18-pulse diode rectifier with series active power filter
PublicationThe paper presents the control system and selected results of experimental tests of the ac/dc power converter consisting of 18-pulse diode rectifier on the basis of coupled reactors and a serial active power filter. Three configurations of the 150kVA converter were tested experimentally and compared: 18-pulse diode rectifier with and without additional grid reactor and the rectifier integrated with the active power filter. The...
-
Impedance Studies of Phosphate-iron Glasses Containing Niobium and Titanium
PublicationThe ac and dc conductivity in phosphate-iron-niobate glasses with addition of titanium oxide was investigated as a function of temperature and frequency with the use of impedance spectroscopy. The topography and microstructure of glasses were investigated by the means of X-ray diffraction (XRD), scanning electron microscopy (SEM), and confocal microscopy methods. The obtained results show that all samples are amorphous but they...
-
Assessment of copper surface coverage with corrosion inhibitor using AFM-based local electrical measurements
PublicationThe paper presents a new method of assessment of metal surface coverage with corrosion inhibitor and thus of inhibitor protective performance. It is based on the atomic force microscopy measurement performed in a contact mode. Apart from topography images the proposed approach allows acquisition of local DC maps and local electrical impedance spectra via application of DC bias voltage or AC perturbation signal between the conductive...
-
A Review of Reduction Methods of Impact of Common-Mode Voltage on Electric Drives.
PublicationIn this survey paper, typical solutions that focus on the reduction in negative effects resulting from the common-mode voltage influence in AC motor drive applications are re-examined. The critical effectiveness evaluation of the considered methods is based on experimental results of tests performed in a laboratory setup with an induction machine fed by an inverter. The capacity of a common-mode voltage level reduction and voltage...
-
Zastosowanie termowizji w diagnostyce i badaniach sprzętu elektronicznego
PublicationZaproponowano zastosowanie techniki termowizyjnej do oceny poprawność konstrukcji i działania urządzeń elektronicznych, biorąc pod uwagę krótki czas badań oraz możliwość bezpośredniej oceny uzyskanych wyników. Technikę termowizyjną zastosowano do badania elementów ochronnych zasilacza AC/DC w czasie standardowych badań odporności na udary oraz do badania modułów GSM pracujących pod kontrolą nadrzędnego programu sterującego i płyty...
-
Zastosowanie termografii w diagnostyce i badaniach urządzeń elektronicznych
PublicationZaproponowano zastosowanie techniki termowizyjnej do oceny poprawność konstrukcji i działania urządzeń elektronicznych, biorąc pod uwagę krótki czas badań oraz możliwość bezpośredniej oceny uzyskanych wyników. Technikę termowizyjną zastosowano do badania elementów ochronnych zasilacza AC/DC w czasie standardowych badań odporności na udary oraz do badania modułów GSM pracujących pod kontrolą nadrzędnego programu sterującego i płyty...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublicationA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...
-
Metody Admission Control oparte na pomiarach.
PublicationSterowanie przyjęciem zgłoszenia jest kluczowym elementem sterowania domeną DiffServ warunkującym świadczenie przez operatora usług z IP QoS. Zasadniczym celem pracy jest dokonanie analizy związanej z metodami AC opartymi na pomiarach określanych skrótem MBAC. Scharakteryzowane zostało sześć metod realizacji MBAC o różnej złożoności obliczeniowej i pomiarowej. Przedstawiona została także realizacja procesu pomiaro-wego wielkości...
-
Microstructure and Dielectric Properties of Barium-vanadate Glasses
PublicationThe ac and dc conductivity in barium-vanadate glasses was investigated as a function of temperature and frequency with the use of impedance spectroscopy. The topography and microstructure of glasses were investigated by the means of X-ray diffraction (XRD) and scanning electron microscopy (SEM) methods. The XRD results show that all samples are amorphous but microscopy investigation reveals that glasses with greater amount of V2O5...
-
Calculation methods of interaction of electromagnetic waves with objects of complex geometries
PublicationModeling of the electromagnetic interaction with different homogeneous or inhomo-geneous objects is a fundamental and important problem. It is relatively easy to solve Maxwellequations analytically when the scattering object is spherical or cylindrical, for example. How-ever, when it loses these properties all that is left for us is to useapproximation models, to ac-quire the solution we need. Modeling of complex, non-spherical,...
-
Measurement methods for assessing insulation condition of underground pipelines
PublicationThe paper discusses the most frequently applied measurement methods for assessing the quality of external insulation along pipelines and detecting defect locations in the protective coating. The quality of coating along a given pipeline section under investigation is assessed by determining unitary resistance of the coating, which is calculated on the basis of measurement results obtained along a pipeline subjected to cathodic...
-
Research of Emergency Modes of Wind Power Plants Using Computer Simulation
PublicationThe aim of this study is to investigate changes in the wind power plant energy production parameters under the conditions of sudden wind changes and voltage drop. To achieve these goals, a simulation of operation of wind power plants was performed. Twelve wind turbines with variable rotational speed equipped with a Fuhrländer FL 2500/104 asynchronous double-fed induction generator (DFIG) were used, each with an installed capacity...
-
Reactions of cobalt(ii) chloride and cobalt(ii) acetate with hemisalen-type ligands: ligand transformation, oxidation of cobalt and complex formation. Preliminary study on the cytotoxicity of Co(ii) and Co(iii) hemisalen complexes
PublicationSeveral molecular cobalt(II) complexes, one Co(II) coordination polymer, and one ionic cobalt(III) complex with imine hemisalen ligands were synthesized. The hemisalen ligands were synthesized from o-vanillin (oVP) and diverse aminopyridines (compounds HL1–HL4) or aminophenol (compound HL5). It was observed that cobalt(II) chloride in dry acetonitrile catalyzes a transformation of HL1 and HL3 instead of complex formation. The conversion...
-
Projektowanie tras tramwajowych przy wykorzystaniu Mobilnych Pomiarów Satelitarnych
PublicationW pracy przedstawiono metodykę projektowania tras tramwajowych dostosowaną do rozwijanej w Zespole Naukowym metody Mobilnych Pomiarów Satelitarnych. Opisano badania inwentaryzacyjne wykonane na torach tramwajowych, których wyniki posłużyły jako dane wejściowe w procesie projektowania. Pokazano, w jaki sposób dostosowano analityczne algorytmy projektowania tras kolejowych do specyfiki układów geometrycz-nych występujących w torach...
-
Application of multi-criteria method to assess the usefulness of a hydrotechnical object for floating housing
PublicationThis publication presents the analysis of three hydrotechnical objects located in the Municipality of Gdańsk with a view of mooring Floating Houses. The assessment of the adaptation of a hydrotechnical object has been carried out by a multi- criteria method AHP and using the main criteria such as: mooring system, communication with the mainland, availability of the utility networks, waste disposal and location of the parking spaces....
-
The Influence of Titania Electrode Modification with Lanthanide Ions Containing Thin Layer on the Performance of Dye-Sensitized Solar Cells
PublicationThe lanthanide and scandium groups ions (except Pm and Ac) have been used as dopants of TiO2 film in dye-sensitized solar cells. The X-ray diffraction spectra show that the modification has no influence on the structure of the electrode; however, the diffuse reflectance UV-Vis measurements exhibit significant changes in the electronic properties of modified electrodes. The appearance of energy barrier preventing photoexcited electron...
-
Development of an emulation platform for synchronous machine power generation system using a nonlinear functional level model
PublicationThe article presents the Power Hardware in the Loop (PHIL) approach for an autonomous power system analysis based on the synchronous generator model incorporating magnetic saturation effects. The model was prepared in the MATLAB/Simulink environment and then compiled into the C language for the PHIL platform implementation. The 150 kVA bidirectional DC/AC commercial-grade converter was used to emulate the synchronous generator....
-
The difficult heritage. The reuse of former prison buildings
PublicationIn recent years, there has been a trend to reuse abandoned buildings. Adaptive re-use allows preservation of the original structure and implements a new function to it. Such activity could help to preserve the historic value of buildings; moreover, many other advantages can be found in educational, ecological and economic fields. However, the question arises of whether every object can be freely adapted. This article examines the...
-
9-(Trichloroacetylimino)acridine monohydrate
PublicationThe title compound, alternatively called N-acridin-9(10H)-ylidene-2,2,2-trichloroacetamide monohydrate, C15H9Cl3N2O·H2O, crystallizes in space group P21/c with Z = 4. The acridine moieties are arranged in layers, tilted at an angle of 15.20 (4)° relative to the ac plane, while adjacent molecules pack in a head-to-tail manner. Acridine and water molecules form columns along the b axis held in place by a network of hydrogen...
-
Transport of alkali metal cations in poly(3,4-ethylenethiophene) films.
PublicationElektrochemicznie otrzymana warstwa kompozytowa złożona z poli(3,4-etyleno-dioksytiofenu) i poli(styrenosulfonianu) podczas polaryzacji ulega odwracalnemu procesowi sorpcji-desorpcji kationów z elektrolitu zewnętrznego. Transportowi jonowemu towarzyszą cząsteczki wody (rozpuszczalnika). Ilość cząsteczek wody przypadająca na jednostkowy kation metali alkalicznych została wyznaczona za pomocą metody elektrochemicznej mikrowagi...
-
Risk of incorrect pass-fail decisions associated with assessment uncertainty
PublicationA mathematical framework for calculation teacher's and student's risks of incorrect pass-fail decisions under uncertainty of assessment, is presented. The probabilistic model of assessment process is adapted from interdisciplinary probabilistic theory of measurement.
-
Acetate-Induced Disassembly of Spherical Iron Oxide Nanoparticle Clusters into Monodispersed Core−Shell Structures upon Nanoemulsion Fusion
PublicationIt has been long known that the physical encapsulation of oleic acid-capped iron oxide nanoparticles (OA−IONPs) with the etyltrimethylammonium (CTA+) surfactant induces the formation of spherical iron oxide nanoparticle clusters (IONPCs). However, the behavior and functional properties of IONPCs in chemical reactions have been largely neglected and are still not well-understood. Herein, we report an unconventional ligand-exchange...
-
Conversion of waste biomass into activated carbon and evaluation of environmental consequences using life cycle assessment
PublicationIn this article, activated carbon was produced from Lantana camara and olive trees by H3PO4 chemical activation. The prepared activated carbons were analyzed by characterizations such as scanning electron microscopy, energy-dispersive X-ray spectroscopy, Brunauer–Emmett–Teller, X-ray diffraction, thermogravimetric analysis, and Fourier transform infrared spectroscopy. H3PO4 is used as an activator agent to create an abundant pore...
-
Inception and Propagation of Electrical Trees in the Presence of Space Charge in HVAC Extruded Cables
PublicationThis paper presents the space charge impact on the inception and propagation of electrical trees in cross-linked polyethylene (XLPE) insulation via simulations and experimentation. A 3D finite element analysis (FEA)-based modeling is proposed to simulate electrical trees via a needle embedded on the XLPE insulation. The proposed FEA model demonstrates the influence of the space charge magnitude and polarity on the initiation of...
-
Charakterystyka stałych przewodzących kompozytów poliuretanowych
PublicationCelem przeprowadzonych badań było określenie właściwości mechanicznych i przewodzących nowych elektrolitów poliuretanowych. Elastomery poliuretanowe, stanowiące matrycę badanych układów, zsyntezowano przy użyciu 4,4'- diizocyjanianu difenylometanu (MDI), oligo(oksytetrametyleno)diolu (PTMG) i 1,4 butanodiolu (BDO). Sól LiClO4 domieszkowano do poliolu a nanonapełniacz wprowadzono podczas przedłużania łańcuchów prepolimeru za pomocą...
-
Charakterystyka właściwości mechanicznych oraz przewodzących stałych przewodzących kompozytów poliuretanowych
PublicationCelem przeprowadzonych badań było określenie właściwości mechanicznych i przewodzących nowych elektrolitów poliuretanowych. Elastomery poliuretanowe, stanowiące matrycę badanych układów, zsyntezowano przy użyciu 4,4'- diizocyjanianu difenylometanu (MDI), oligo(oksytetrametyleno)diolu (PTMG) i 1,4 butanodiolu (BDO). Sól LiClO4 oraz nanonapełniacz wprowadzono wykorzystując wytłaczarkę dwuślimakową. Przewodnictwo jonowe wyznaczono...
-
Badania eksperymentalne prostownika osiemnastopulsowego o mocy 150 kVA z opcjonalnym szeregowym energetycznym filtrem aktywnym
PublicationW artykule przedstawiono system sterowania oraz wybrane wyniki badań eksperymentalnych przekształtnika AC / DC składającego się z osiemnastopulsowego diodowego prostownika na bazie dławików sprzężonych i szeregowego energetycznego filtra aktywnego. Przebadano i porównano trzy konfiguracje przekształtnika o mocy 150kVA: (1) osiemnastopulsowy prostownik bez dodatkowych elementów, (2) prostownik z dodatkowym dławikiem sieciowym oraz...
-
Oddziaływanie przekształtników energoelektronicznych dużej mocy na jakość energii elektrycznej
PublicationW referacie przedstawiono zagadnienia związane z oddziaływaniem układów przekształtnikowych AC/DC na sieć zasilającą poprzez generowanie prądów odkształconych. Przedstawione wyniki badań porównawczych emisji zaburzeń przewodzonych układów prostownikowych klasycznych (diodowych) oraz nowoczesnych (tranzystorowych) wykazują znaczne zwiększenie emisji w zakresie stosowanych częstotliwości modulacji w typowych aplikacjach przemysłowych....
-
New Method of Non-Linear Electrochemical Impedance Spectroscopy with an Amplitude-Modulated Perturbation Signal
PublicationThe paper presents a new method of non-linear electrochemical impedance spectroscopy (NLEIS), which allows fast and nondestructive evaluation of the corrosion rate and determination of the Tafel coefficients values for a corrosion system under investigation. This method employs amplitude modulation of the ac perturbation signal. The study demonstrated that it was possible to obtain impedance characteristic as a function of the...
-
Implementation of constant component filter in measurements of random telegraph signal noise
PublicationNoise is generated in all semiconductor devices. The intensity of these fluctuations depends on used elements, manufacturing process, operating conditions and device type. The result noise is a superposition of different kinds of fluctuations like thermal noise, generation-recombination noise, 1/f noise, shot noise and Random Telegraph Signal (RTS) noise. The last one, RTS noise is observed as nonstationary impulse fluctuations....
-
Detekcja i lokalizacja nieprzewodzenia tranzystorów falownika napięcia na podstawie analizy prądu obciążenia
PublicationPrzedstawiono nową metodę detekcji i lokalizacji nieprzewodzenia tranzystorów w falownikach napięcia zasilających silniki indukcyjne małej mocy. Metoda bazuje na monitorowaniu wartości dwóch sygnałów dia-gnostycznych. Pierwszy z nich, wskaźnik braku przepływu prądu, wykorzystano w celu detekcji uszkodzeń. Drugi, stosunek wartości średniej prądu do wartości średniej bezwzględnej, zawiera informacje umożliwiające lokalizację uszkodzonych...
-
The contribution of Hans von Wartenberg to the development of the Czochralski method
PublicationThe contribution of Hans von Wartenberg to the development of the Czochralski Method for pulling single crystals is often overlooked. He was its earliest adopter, having introduced the use of seed crystals, and his detailed description of the method was the basis for its subsequent dissemination.
-
Lithium ion insertion into poly(3,4-ethylenedioxythiophene) films from propylene carbonate electrolytes.
PublicationPolimerowa matryca złożona z poli(3,4-etylenodioksytiofenu z poli(styrenosulfonianem) otrzymana została na drodze syntezy elektrochemicznej. Transport jonowy w matrycy polimerowej w kontakcie z węglanem propylenu zawierającym LiClO4 został scharakteryzowany za pomocą metody impedancji ac oraz chronowoltoamperometrii. Wyznaczono przewodność jonową matrycy oraz efektywne współczynniki dyfuzji dla kationu Li+. Wielkości te...
-
Experimental investigations and simulations of the microturbine unit with permanent magnet generator
PublicationIn dispersed power generation, low power devices are used for local combined generating of heat end electric power. There are developing concepts of micropower plants with electric generators driven by steam or gas microturbines. The paper presents the results of an experimental investigations of the microturbine set consists of the turbine with partial admission, permanent magnet generator and three phase AC-to-DC rectifier. The...
-
Fractional Calculus Evaluation of Hyaluronic Acid Crosslinking in a Nanoscopic Part of Articular Cartilage Model System
PublicationThis work presents a study of the mechanism of physical crosslinking of hyaluronic acid in the presence of common phospholipids in synovial joint organ systems. Molecular dynamic simulations have been executed to understand the formation of hyaluronan networks at various phospholipid concentrations. The results of the simulations suggest that the mechanisms exhibit subdiffusion characteristics. Transportation quantities derive...
-
Wyznaczanie parametrów modelu generatora synchronicznego zmodyfikowaną metodą SSFR w oparciu o symulacje MES z uwzględnieniem nasycenia
PublicationW artykule przedstawiono zmodyfikowaną metodę SSFR wyznaczania parametrów modelu generatora synchronicznego z uwzględnieniem nasycenia obwodu magnetycznego. Charakterystyki częstotliwościowe uzyskano na drodze symulacji z wykorzystaniem metody elementów skończonych. Założono, że stan nasycenia rdzenia generatora może zostać uwzględniony poprzez zmianę wartości względnej przenikalności magnetycznej. W pierwszym etapie symulację...
-
Determination of pitting corrosion stage of stainless steel by galvanodynamic impedance spectroscopy
PublicationThis paper investigates the methodology for differentiation of multistep process of pitting corrosion of AISI 304 stainless steel in the environment of iron (III) chloride. Measurements were performed using Galvanodynamic Electrochemical Impedance Spectroscopy (GDEIS). Application of this methodology allowed monitoring of natural corrosion process without external current (IDC = 0A) nor potential perturbation of the system. Applied...
-
Development of dynamic method for evaluation of inhibition efficiency on the example of 8-hydroxyquinolin
PublicationSelection of a proper inhibitor should be based on the evaluation of its mechanism and effective concentrations. Mechanism of inhibition usually has dynamic character due to changing physicochemical conditions of the environment and corroding metal surface. Most of actually used methods are stationary or contain assumptions which highly influences obtained values. Development of new dynamic method, based on modified EIS, allows...
-
Evolution of the HVDC Link Connecting Offshore Wind Farms to Onshore Power Systems
PublicationThis paper presents an overview of the DC link development and evolution dedicated to HVDC structure for connecting offshore wind power plants to onshore power systems. The growing demand for the green energy has forced investors in power industry to look for resources further out at sea. Hence, the development of power electronics and industrial engineering has enabled offshore wind farms to be situated further from the shore...