Filtry
wszystkich: 4215
wybranych: 3115
-
Katalog
- Publikacje 3115 wyników po odfiltrowaniu
- Czasopisma 90 wyników po odfiltrowaniu
- Konferencje 15 wyników po odfiltrowaniu
- Osoby 80 wyników po odfiltrowaniu
- Projekty 3 wyników po odfiltrowaniu
- Kursy Online 163 wyników po odfiltrowaniu
- Wydarzenia 3 wyników po odfiltrowaniu
- Dane Badawcze 746 wyników po odfiltrowaniu
Filtry wybranego katalogu
wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: INDOOR AIR QUALITY
-
Influence of terpenes on indoor air quality
PublikacjaThe aim of this study was to investigate air quality in hairdresser salons, focusing on terpenes determination. Terpenes are known reactive volatile organic compounds that contribute to secondary organic aerosol formation. Those compounds are frequently found in cosmetic products as fragrance agents. Hairdresser salons are special kind of environment, where secondary organic aerosol concentration may be elevated. One hairdresser...
-
Indoor Air Quality: A Bibliometric Study
Publikacja -
Electronic Noses for Indoor Air Quality Assessment
PublikacjaThis chapter presents a proposal of the use of electronic noses in the monitoring of indoor air quality. The main focus is put on the detailed characteristics of today’s indoor air quality control methods, the types of pollution in the air, and the development of electronic noses for air testing. Currently, scientists seek methodological and structural solutions that would enable real-time online indoor air control. It has been...
-
Passive samplers in indoor air quality control
PublikacjaPrzedstawiono wyniki badań jakości powietrza wewnętrznego w 12 wybranych mieszkaniach usytuowanych na terenie aglomeracji Trójmiejskiej z wykorzystaniem techniki pasywnej (dozymetria pasywna typu permeacyjnego) oraz techniki dynamicznej (rurki sorpcyjne wypełnione sorbentem Tenax TA). Wykorzystując nowe podejście do sposobu kalibracji dokonano monitoringu zarówno poszczególnych lotnych związków organicznych jak i sumarycznej zawartości...
-
Indoor air quality in public utility environments-a review
PublikacjaIndoor air quality has been the object of interest for scientists and specialists from the fields of science such as chemistry, medicine and ventilation system design. This results from a considerable number of potential factors, which may influence the quality of the broadly understood indoor air in a negative way. Poor quality of indoor air in various types of public utility buildings may significantly affect an increase in the...
-
Permeation passive sampling as a tool for the evaluation of indoor air quality
PublikacjaOkreślono stężenie średnie ważone w czasie wybranych lotnych związków organicznych w powietrzu ośmiu pomieszczeniach mieszkalnych na terenie miasta Gdańska. Do pobierania próbek analitów z powietrza wewnętrznego zastosowano permeacyjny dozymetr pasywny typu pudełkowego oraz technikę dynamiczną (urządzenie przepływowe z rurką sorpcyjną). Porównano wyniki uzyskane w wyniku zastosowania w/w technik pobierania próbek analitów.
-
Properties of an innovative multi-functional finish for the improvement of indoor air quality
PublikacjaDue to lifestyle changes, people spend most of their time indoors at present; thus, Indoor Air Quality (IAQ) is a matter of utmost importance. Multi-functional and innovative finishes can help to passively improve the IAQ, benefitting the health and comfort of occupants. For this study, reference and pre-mixed commercial mortars are compared to a new multi-functional hydraulic lime mortar for indoor finishes, in which conventional...
-
Indoor air quality of everyday use spaces dedicated to specific purposes—a review
PublikacjaAccording to literature data, some of the main factors which significantly affect the quality of the indoor environment in residential households or apartments are human activities such as cooking, smoking, cleaning, and indoor exercising. The paper presents a literature overview related to air quality in everyday use spaces dedicated to specific purposes which are integral parts of residential buildings, such as kitchens, basements,...
-
Numerical investigations of effect of indoor air quality on thermal comfort in residential buildings.
PublikacjaArtykuł przedstawia wyniki numeryczne MES odnośnie wpływu koncentracji CO2 w lokalnej strefie powietrza w budynkach mieszkalnych naturalnie wentylowanych na zachowanie mieszkańców. Obliczenia wykonano w 2 wymiarach. Zbadano wpływ położenia mieszkańców i prędkości wchodzącego powietrza.
-
Jakość powietrza wewnętrznego - lotne związki organiczne jako wskaźnik jakości powietrza wewnętrznego = Indoor air quality - volatile organic compounds as an indicator of the quality of indoor air
PublikacjaPomieszczenia zamknięte z jednej strony są barierą chroniącą przed negatywnymi czynnikami środowiska, zmiennymi warunkami pogodowymi - deszczem, wiatrem, niską lub wysoką temperaturą, z drugiej jednak strony - w zamkniętych wnętrzach nastepuje często kumulacja toksycznych związków organicznych i nieorganicznych, co nie pozostaje bez wpływu na ludzkie zdrowie.Głównym celem badań jest oszacowanie jakości powietrza wewnętrznego pod...
-
Indoor Air Quality and Thermal Comfort in Naturally Ventilated Low-Energy Residential Houses
PublikacjaRozdział omawia jakość powietrza i termiczny komfort w naturalnie wentylowanych energooszczędnych budynkach mieszkalnych. Obliczenia wykonano metoda elementów skończonych dla wentylacji naturalnej. Uwzględniono 2 różne położenia wlotów powietrza oraz system grzewczy kaloryferowy i podłogowy. Wyniki MES porównano z doświadczeniami.
-
Employment of passive sampling in monitoring indoor air quality in selected residences in a Tri-city area in Poland
PublikacjaTime-weighted average concentrations of selected volatile compounds were measured in chosen residences in a Tri-City area of Poland by means of passive sampling. The results were compared to those obtained by dynamic technique – sorption tubes filled with Tenax TA sorbent. Results obtained by employing the two techniques were similar. Total volatile organic compound (TVOC) parameters were also determined. An attempt was also...
-
Employment of passive sampling in monitoring indoor air quality in selected residences in a Tri-city area in Poland
PublikacjaNa etapie pobierania próbek analitów zastosowano dwie techniki: pasywną - wykorzystującą permeacyjne dozymetry pasywne oraz technikę klasyczną - wykorzystującą rurki sorpcyjne. Wyznaczono sumaryczną zawartość TVOC lotnych związków organicznych.
-
Influence of Binders and Lightweight Aggregates on the Properties of Cementitious Mortars: From Traditional Requirements to Indoor Air Quality Improvement
Publikacja -
The Use of Sensory Analysis Techniques to Assess the Quality of Indoor Air
PublikacjaThe quality of indoor air is one of the significant elements that influences people's well-being and health inside buildings. Emissions of pollutants, which may cause odor nuisance, are the main reason for people's complaints regarding the quality of indoor air. As a result, it is necessary to perform tests aimed at identifying the sources of odors inside buildings. The article contains basic information on the characteristics...
-
Zastosowanie techniki dozymetrii pasywnej do oceny jakości powietrza wewnętrznego. Application of passive sampling technique for assessment of indoor air quality
PublikacjaJakość powietrza wewnętrznego jest istotnym parametrem wpływającym na dobre samopoczucie i zdrowie człowieka. Kluczowego znaczenia nabiera więc jego nieustanna kontrola i oznaczanie zawartości zanieczyszczeń, które występują w nim na bardzo niskich poziomach stężeń. Do pomiarów jakości powietrza wewnętrznego często wykorzystywana jest (znana od ponad pół wieku) technika dozymetrii pasywnej. W literaturze nadal pojawiają się doniesienia...
-
Investigation on air quality of specific indoor environments—spa salons located in Gdynia, Poland
PublikacjaDue to excessive application of essential oils and scented products in spa salons during aromatherapy and massage sessions, the elevated concentration of total volatile organic compounds (TVOCs), particularly terpenes, which are known as secondary organic aerosol (SOA) precursors, is expected there. This study was aimed at determination of VOCs with a particular regard to terpenes in air samples collected in selected spa salons...
-
α-Pinene, 3-carene and d-limonene in indoor air of Polish apartments: The impact on air quality and human exposure
PublikacjaMonoterpenes are among most ubiquitous volatile organic compounds (VOCs) to be detected in indoor air. Since the quality of indoor air is considered important for inhabitants' well-being, the present study aimed at investigating impact of human activity on levels of selected monoterpenes applying passive sampling technique followed by thermal desorption and gas chromatography coupled mass spectrometry. One of the objectives of...
-
Recent advances on SOA formation in indoor air, fate and strategies for SOA characterization in indoor air - A review
PublikacjaRecent studies proves that indoor air chemistry differs in many aspects from atmospheric one. People send up to 90 % of their life indoors being exposed to pollutants present in gas, particle and solid phase. Particle phase indoor is composed of particles emitted from various sources, among which there is an indoor source – secondary chemical reactions leading to formation of secondary organic aerosol (SOA). Lately, researchers'...
-
Monitoring and analytics of semivolatile organic compounds (SVOCs) in indoor air
PublikacjaThis paper reviews literature information on the behaviour of semivolatile organic compounds (SVOCs) in the indoor environment, as well as the most likely emission sources. The consecutive stages of analytical procedures used for monitoring SVOCs in indoor environments are described. The most common approaches used for collecting samples from the gas and particulate phases are mentioned. The paper discusses and compares various...
-
TiO2-based photocatalysts in indoor swimming pool air purification
PublikacjaWzrastająca ilość basenów kąpielowych i aquaparków jest obecnie wyzwaniem dla naukowców zajmujących się badaniem i kontrolowaniem powietrza hali basenowej. Mikroorganizmy powstałe w powietrzu hali stanowią ogromne zagrożenie dla zdrowia. Ponadto, w fazie gazowej obecne są także uboczne produkty dezynfekcji (DBP), które mogą mieć szkodliwy wpływ zarówno na kąpiących się, jak i personel. W pracy omówiono potencjalne zagrożenia spowodowane...
-
Air quality policy in the U.S. and the EU – a review
PublikacjaThe high level of atmospheric pollution is a global problem that has taken on particular significance in recent years and will continue to grow in the near future. Air pollution directly affects the health, living organisms, vegetation, water, soil and buildings. Additionally, it moves easily even over long distances. Certain air pollutants influence the climate, cause negative processes in the protective ozone layer and contribute...
-
Current air quality analytics and monitoring: A review
PublikacjaThis review summarizes the different tools and concepts that are commonly applied in air quality monitoring. The monitoring of atmosphere is extremely important as the air quality is an important problem for large communities. Main requirements for analytical devices used for monitoring include a long period of autonomic operation and portability. These instruments, however, are often characterized by poor analytical performance....
-
Testing and sampling devices for monitoring volatile and semi-volatile organic compounds in indoor air
PublikacjaAdults spend most of their time in enclosed spaces (e.g., apartment, office and public buildings). According to research conducted by scientists, air quality indoors is much worse than the ambient air quality outdoors. Hazardous chemicals found in air indoors can adversely affect the functioning of the human body and cause many respiratory and circulatory diseases. Harmful chemical compounds (mainly volatile organic compounds and...
-
Mobile monitoring system for control of atmospheric air quality
PublikacjaW pracy przedstawiono ruchomy system monitoringu powietrza, który zapewnia możliwość ciągłego pomiaru stężenia takich zanieczyszczeń powietrza jak benzen, tlenek i ditlenek azotu oraz tlenek i ditlenek węgla. Opracowany zestaw pomiarowy może być zainstalowany na rożnych pojazdach (samochód, autobus, ciężarówka).System zbudowany jest z zestawu małych przenośnych jednostek pomiarowych (elektroniczne urządzenia pomiarowe, rejestrator...
-
Toward the next generation of air quality monitoring: Mercury
PublikacjaMercury is a global pollutant that is ubiquitous in the environment. Enrichment of mercury in the biosphere as the result of human activities and subsequent production of methylmercury (MeHg) has resulted in elevated concentrations in fish, wildlife and marine mammals globally. Elemental mercury (Hg0) is the most common form of mercury in the atmosphere, and the form that is most readily transported long distances from its emission...
-
The critical factors of landfill fire impact on air quality
Publikacja -
Determination of Volatile Organic Compounds in Indoor Air in the Gdansk Area Using Permeation Passive Samplers
PublikacjaPassive dosimetry — known for over a hundred years — is still a useful tool in monitoring air pollutants. In this work, permeation passive samplers were used to determine indoor air quality in 22 apartments located in the Gdansk area in the northern part of Poland. The results obtained by the passive sampling technique were compared to those obtained by dynamic sampling. Attempts were also made to identify indoor sources of...
-
Health impacts of indoor air pollution from household solid fuel on children and women
Publikacja -
AIR QUALITY INFLUENCE OF SELECTED POLLUTANTS EMITTED FROM A FIRE OF 300 MG OF MUNICIPAL WASTE ON AMBIENT AIR QUALITY: AN EXAMPLE OF MODELLING WITH HYSPLIT
Publikacja -
Polybrominated diphenyl ether (PBDE) concentrations in dust from various indoor environments in Gdańsk, Poland: Prediction of concentrations in indoor air and assessment of exposure of adults
PublikacjaMonitoring of polybrominated diphenyl ethers (PBDEs) in indoor environments involves the determination of their concentrations in air, airborne particles, and settled dust. Each of these is a source of human exposure to PBDEs. In this study, we attempted to model PBDEs concentrations in various typical indoor environments on the basis of real PBDEs measurements in dust collected from them. The analytical procedure for determining...
-
Urban Vegetation in Air Quality Management: A Review and Policy Framework
PublikacjaRecent episodes of high air pollution concentration levels in many Polish cities indicate the urgent need for policy change and for the integration of various aspects of urban development into a common platform for local air quality management. In this article, the focus was placed on the prospects of improving urban air quality through proper design and protection of vegetation systems within local spatial planning strategies....
-
Determination of Volatile Organic Compounds in indoor air in the Gdansk area using permeation passive samplers.
PublikacjaDozymetria pasywna, znana od wielu lat, jest użytecznym narzędziem w monitoringu poziomu zanieczyszczeń. Do określenia jakości powietrza wewnętrznego w 22 pomieszczeniach mieszkalnych, zlakoalizowanych na terenie Gdańska, wykorzystano dozymetry pasywne typu permeacyjnego na etapie pobierania próbek analitów. Uzyskane wyniki porównano z wynikami uzyskanymi przy wykorzystaniu matedy dynamicznej. Podjęto również próbę identyfikacji...
-
Implementation of the Indoor Environmental Quality (IEQ) Model for the Assessment of a Retrofitted Historical Masonry Building
Publikacja -
Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air
PublikacjaThe paper presents principle of operation and design of the most popular chemical sensors for measurement of volatile organic compounds (VOCs) in outdoor and indoor air. It describes the sensors for evaluation of explosion risk including pellistors and IR-absorption sensors as well as the sensors for detection of toxic compounds such as electrochemical (amperometric), photoionization and semiconductor with solid electrolyte ones....
-
Comparison of the measurement techniques employed for evaluation of ambient air odour quality
PublikacjaThe paper presents the results of investigation on ambient air odour quality in a vicinity of the industrial sewage treatment plant being a part of the crude oil processing plant. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field...
-
The applicability of low-cost PM10 sensors for atmospheric air quality monitoring
PublikacjaDescribed in this work are the results of field tests carried out in the Tricity Agglomeration between 01 April 2018 and 30 June 2018 in order to evaluate the usefulness of low-cost PM10 sensors in atmospheric air quality monitoring. The results were juxtaposed with the results obtained using reference methods. The results were validated based on the measurement uncertainty as described in...
-
Chapter 11 – Application of Chemical Sensors and Sensor Matrixes to Air Quality Evaluation
PublikacjaIndoor and outdoor air quality is one of the key factors influencing human health. However, air quality evaluation is not easy task. Air is a complex system, which is subjected to changes even within short period of time. Progress in analytical methods and analytical tools provides increasingly more reliable information on the condition and quality of indoor and outdoor air. This progress, however, generates an increase in the...
-
Investigation of RH effect on uncommon limonene ozonolysis products and SOA formation in indoor air with real time measurement techniques
PublikacjaScientific interest in SOA influence on indoor air quality increases since last 20 years. It is well known, that particles of nano-sized diameter pose a threat for human health causing, among others: eye, upper airway irritation, inflammatory response in cells, worsening asthma, hypertension, diabetes, and central nervous dysfunction. Terpenes are reactive VOCs, commonly emitted in indoor air and considered to be SOA precursors...
-
Balanced Spider Monkey Optimization with Bi-LSTM for Sustainable Air Quality Prediction
PublikacjaA reliable air quality prediction model is required for pollution control, human health monitoring, and sustainability. The existing air quality prediction models lack efficiency due to overfitting in prediction model and local optima trap in feature selection. This study proposes the Balanced Spider Monkey Optimization (BSMO) technique for effective feature selection to overcome the local optima trap and overfitting problems....
-
Developing the Urban Blue-Green Infrastructure as a Tool for Urban Air Quality Management
PublikacjaUrban structure is an important factor that shapes the process of urban ventilation and pollution dispersion. With proper planning of the urban spatial layout, city breathability can be effectively regulated, contributing to urban air quality improvement. This paper investigates the development and current management of urban systems of green and open spaces in four Polish cities: Gda ´nsk, Warsaw, Pozna ´n and Wrocław, with a...
-
Determination of Odor Air Quality Index (OAQII) Using Gas Sensor Matrix
PublikacjaThis article presents a new way to determine odor nuisance based on the proposed odor air quality index (OAQII), using an instrumental method. This indicator relates the most important odor features, such as intensity, hedonic tone and odor concentration. The research was conducted at the compost screening yard of the municipal treatment plant in Central Poland, on which a self-constructed gas sensor array was placed. It consisted...
-
Association between changes in air quality and hospital admissions during the holi festival
Publikacja -
Effect of transregional transport of pollutants on atmospheric air quality in the Tricity area of Poland
PublikacjaDwuwymiarowa analiza wariancji wyników oznaczania jonów nieorganicznych, pH oraz przewodnictwa konduktometrycznego w próbkach wód opadowych zebranych w rejonie Trójmiasta pokazała, że transregionalny transport substancji zanieczyszczających środowisko ma wpływ na jakość powietrza w tym rejonie. W całym Trójmieście wahania stężeń analitów w wodach opadowych nie są spowodowane w znacznym stopniu przez lokalizacje miejsc pobierania...
-
A new approach in the calibration of passive samplersA new approach on the calibration of passive dosimeters for studies of indoor air (....--------ROZBIEŻNOŚĆ TYTUŁÓW-------------------------------------
PublikacjaPrzedstawiono problematykę kalibracji próbników pasywnych wykorzystywanych w Katedrze Chemii Analitycznej Wydz. Chemicznego PG do monitoringu jakości powietrza wewnętrznego. Proponowane podejście pozwala na oszacowanie wartości stałych kalibracyjnych, a tym samym oznaczenia stężeń związków od heksanu do dodekanu. Tak więc permeacyjne dozymetry pasywne mogą być wykorzystane w analogicznym zakresie jak próbniki aktywne.
-
The Potential of Improving Air Quality by Urban Mobility Management: Policy Guidelines and a Case Study
PublikacjaThere is a growing recognition among planners and policy makers that proper transformation of urban mobility systems is crucial to the reduction of air pollution emission. The main objective of the work was to review the current urban mobility strategies in the city of Gdańsk, Poland in terms of their potential for the improvement of urban air quality. Firstly, general policy guidelines for mobility systems were formulated based...
-
Investigation of Air Quality beside a Municipal Landfill: The Fate of Malodour Compounds as a Model VOC
PublikacjaThis paper presents the results of an investigation on ambient air odour quality in the vicinity of a municipal landfill. The investigations were carried out during the spring–winter and the spring seasons using two types of the electronic nose instrument. The field olfactometers were employed to determine the mean odour concentration, which was from 2.1 to 32.2 ou/m3 depending on the measurement site and season of the year. In...
-
Application of passive sampling technique in monitoring research on quality of atmospheric air in the area of Tczew, Poland.
PublikacjaThis paper presents the results of atmospheric air quality research in Tczew (adjacent to the Vistula River) on the content of BTEX compounds. Analytical procedure applied during the sampling of the analytes from the air used the passive sampling technique (diffusive passive sampler, Radiello®). For determination of BTEX compounds in atmospheric air, two-stage thermal desorption technique combined with gas chromatography (TD-GC-FID)...
-
Evaluation of Ambient Air Odour Quality in Vicinity of Municipal Landfill Using Electronic Nose Technique
PublikacjaThe paper presents the results of investigation on ambient air quality evaluation with respect to concentration of odorants in a vicinity of municipal landfill. The investigation was carried out with a prototype of electronic nose and a team of panelists utilizing the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. Performed measurements...
-
Investigation of the Dynamism of Nanosized SOA Particle Formation in Indoor Air by a Scanning Mobility Particle Sizer and Proton-Transfer-Reaction Mass Spectrometry
PublikacjaTerpenes are VOCs of particular importance, since they are emitted from a wide range of indoor sources and are considered to be precursors of Secondary Organic Aerosol (SOA) formation. It has been proven that SOA particles, especially nanosized ones, pose a threat to human health. In this research, experiments with the application of an environmental chamber and real-time measurement techniques were carried out to investigate in...
-
Conception of Interactive Information and Decision Support System for Urban and Industrial Air Quality Management: Extension
Publikacja -
Cold Start Emissions of Spark-Ignition Engines at Low Ambient Temperatures as an Air Quality Risk
Publikacja -
The Quality of Air in Polish Health Resorts with an Emphasis on Health on the Effects of Benzo(a)pyrene in 2015–2019
Publikacja -
Exploring the Institutional and Bottom-Up Actions for Urban Air Quality Improvement: Case Studies in Antwerp and Gdańsk
PublikacjaThe article presents the results of qualitative studies concerning the presence of air quality management in the process of urban planning and in the public discourse in Antwerp, Belgium, and Gdańsk, Poland. We focused on the way urban planners, environmental experts, and stakeholders perceive the problem of air pollution, especially with respect to urban development policy, and whether they consider it one of the major factors...
-
Effective Air Quality Prediction Using Reinforced Swarm Optimization and Bi-Directional Gated Recurrent Unit
PublikacjaIn the present scenario, air quality prediction (AQP) is a complex task due to high variability, volatility, and dynamic nature in space and time of particulates and pollutants. Recently, several nations have had poor air quality due to the high emission of particulate matter (PM2.5) that affects human health conditions, especially in urban areas. In this research, a new optimization-based regression model was implemented for effective...
-
Ocena jakości powietrza atmosferycznego na terenie Aglomeracji Trojmiejskiej = Quality of atmospheric air in the Tricity area
PublikacjaNa terenie Aglomeracji Trójmiejskiej i Tczewa monitoring jakości powietrza prowadzony jest, obok jednostek samorządowych przez fundację: Agencja Monitoringu Regionalnego Atmosfery Aglomeracji Gdańskiej - ARMAAG. Katedra Chemii Analitycznej PG współpracując z fundacją ARMAAG podjęła próbę uzupełnienia informacji na temat stanu atmosfery na terenie Trójmiasta i Tczewa o ocenę pod względem zawartości analitów z grupy BTEX. Celem...
-
Transformation of the countryside into an open-air museum as a way to rescue its spatial layot and to improve the quality of life
Publikacja -
HOW TO EFFECTIVELY ANALYSE THE IMPACT OF AIR QUALITY ON SOCIETY – REVIEW OF MODERN MEASUREMENT TECHNIQUES AND APPARATUS: PARTICULATES
Publikacja -
Predicting the Number of Days With Visibility in a Specific Range in Warsaw (Poland) Based on Meteorological and Air Quality Data
Publikacja -
Średnio - i trudnolotne związki organiczne w powietrzu wewnętrznym. Analityka i monitoring = Semivolatile organic compounds in indoor air. Analytics and monitoring
PublikacjaZwiązki organiczne występujące w powietrzu wewnętrznym na różnych poziomach stężeń mogą stanowić poważną przyczynę problemów zdrowotnych mieszkańców i użytkowników pomieszczeń. Bardzo ważnym staje się zagadnienie monitoringu obecności związków organicznych, należących do grupy trwałych zanieczyszczeń organicznych (POP).
-
Interactive information and decision support system for urban and industrial air quality management based on multi-agent system
PublikacjaThis article presents conception of interactive information and decision support system for urban and industrial air quality management. The emphasis of the project is on real-time analysis and multi-media information, and the support of distributed and mobile clients through the Internet. The approach integrates meteorological data and forecasts, air quality and emission monitoring, dynamic 3D simulation modelling and forecasting,...
-
Spatial aspects of urban air quality management: Estimating the impact of micro-scale urban form on pollution dispersion
PublikacjaUrban planning and design solutions affect urban ventilation conditions, thus mitigating the effects of atmospheric pollution. However, these findings are not being implemented in the planning practice to a sufficient extent, partly due to the lack of specific guidelines. Moreover, many urban air quality monitoring (AQM) sites have low represnentativeness and thus do not provide comprehensive data for effective urban air pollution control...
-
Mobile monitoring system for air quality control along traffic routes = Monitoring zanieczyszczeń wzdłuż ciągów komunikacyjnych
PublikacjaW referacie przedstawiono budowę i zasadę działania mobilnej stacji monitoringu do badania i analizy zanieczyszczeń powietrza atmosferycznego wzdłuż ciagów komunikacyjnych. Przedstawiono również wyniki badań imisji substancji emitowanych z pojazdów poruszających się wzdłuż układu komunikacyjnego Trójmiasta stosując urzadzenie ETL 2000 Bus, zamontowane na dachu samochodu osobowego. Wcześniej, uzyskane wyniki porównano z wynikami...
-
Effect of different ventilation systems on air quality, heat consumption and psycho-physical comfort in modern residential buildings
PublikacjaArtykuł omawia wpływ różnych systemów wentylacji na jakość powietrza, zużycie ciepła i komfort psychiczno-fizyczny w nowoczesnych domach mieszkalnych na terenie Niemiec. Badania wykonano na kompleksie domków jednorodzinnych. Zbadano wpływ 4 systemów wentylacji.
-
A framework for Air Quality Management Zones - Useful GIS-based tool for urban planning: Case studies in Antwerp and Gdańsk
PublikacjaThere is a growing recognition of the importance of proper urban design in the improvement of air flow and pollution dispersion and in reducing human exposure to air pollution. However, a limited number of studies have been published so far focusing on the development of standard procedures which could be applied by urban planners to effectively evaluate urban conditions with respect to air quality. To fill this gap, a new approach...
-
Application of Electronic Nose to Ambient Air Quality Evaluation With Respect to Odour Nuisance in Vicinity of Municipal Landfills and Sewage Treatment
PublikacjaThis chapter contains information about application of the electronic nose type instruments to evaluation of ambient air odour quality connected with such sectors of human activity as municipal landfills or sewage treatment plants. The authors present potential sources of emission from these sectors, characterize the chemical compounds responsible for presence of unpleasant odours, describe the influence of those compounds on human...
-
Comparison of the Measurement Techniques Employed for Evaluation of Ambient Air Odour Quality Influenced by Operation of Industrial Sewage Treatment Plant
PublikacjaThe paper presents the results of investigation on ambient air quality evaluation with respect to concentration of odorants in a vicinity of a sewage treatment plant of the LOTOS Group S.A. petroleum plant. The investigation was performed during winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type...
-
Comparison of Evaluation of Air Odour Quality in Vicinity of Petroleum Plant Using a Prototype of Electronic Nose Instrument and Fast GC Technique
PublikacjaThe paper presents the results of investigation on classification of the ambient air samples collected in a vicinity of the LOTOS Group S.A. petroleum plant with respect to odour. The investigations were carried out with an electronic nose prototype and a commercial electronic nose of Fast GC-type – HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and a photoionization sensor of PID-type....
-
Different Ways to Apply a Measurement Instrument of E-Nose Type to Evaluate Ambient Air Quality with Respect to Odour Nuisance in a Vicinity of Municipal Processing Plants
PublikacjaThis review paper presents different ways to apply a measurement instrument of e-nose type to evaluate ambient air with respect to detection of the odorants characterized by unpleasant odour in a vicinity of municipal processing plants. An emphasis was put on the following applications of the electronic nose instruments: monitoring networks, remote controlled robots and drones as well as portable devices. Moreover, this paper presents...
-
<p>Potential effects of microbial air quality on the number of new cases of diabetes type 1 in children in two regions of Poland: a pilot study</p>
Publikacja -
Results from a collective bound case studies analysis of researched Pol‐ ish metropolises for inspecting information management regarding air quality in light of information ecology
Publikacja -
Zastosowanie analizy szeregów czasowych do oceny zanieczyszczenia powietrza atmosferycznego w rejonie Trójmiasta. Application of time series analysis on air quality assessment in the region of Tricity
PublikacjaNa podstawie analizy wyników pomiarów poziomów stężenia: NO3-, SO42-, F- ,Cl-, NH4+, PO43-, Ca2+, K+, Mg2+ oraz pomiarów pH i przewodności elektrolitycznej próbek wód opadowych na terenie Trójmiasta z zastosowaniem techniki analizy szeregów czasowych wykazano, że cykliczne wahania poziomów depozycji SO42-, F-, NO3- i Ca2+ w próbkach są skorelowane z cyklicznymi 9 zmianami przeważających kierunków wiatrów. Analiza struktury szeregów...
-
Gas‐Phase Removal of Indoor Volatile Organic Compounds and Airborne Microorganisms Over Mono‐ and Bimetal‐Modified (Pt, Cu, Ag) Titanium(IV) Oxide Nanocomposites
PublikacjaThe photocatalytic deactivation of volatile organic compounds and mold fungi using TiO2 modified with mono‐ and bimetallic (Pt, Cu, Ag) particles is reported in this study. The mono‐ and bimetal‐modified (Pt, Cu, Ag) titanium(IV) oxide photocatalysts were prepared by chemical reduction method and characterized using XRD, XPS, DR/UV‐Vis, BET and TEM analysis. The effect of incident light, type and content of mono‐ and bimetallic...
-
Transformation of the countryside into an open-air museum as a way to rescure its spatial layout and to improve the quality of live = Przekształcenie wsi w muzeum na wolnym powietrzu jako sposób ratowania jej układu przestrzennego i poprawy jakości życia mieszkańców
PublikacjaSince the first open-air museums until today, the exposition subject-matter has been specialized (ethnographic, archeological, industrial and technical skansens). But idea of the existence of such objects remains unchanged. Still, the goal is to show the collection of wooden buildings in the environment as close to their origin as possible or in the home environment. These distinguish the skansens and make them different then municipal...
-
BTEX concentration levels in urban air in the area of the Tri-City agglomeration (Gdansk, Gdynia, Sopot), Poland
PublikacjaThe paper presents and discusses the results of atmospheric air quality research conducted in 2012 with reference to the level of BTEX compounds in the Tri-City agglomeration—Gdansk, Gdynia, and Sopot (northern Poland). At the stage of BTEX sampling from the ambient air, Radiello® diffusive passive samplers were applied. The annual time-weighted average concentrations for benzene, toluene, ethylbenzene, and xylenes (BTEX) in the...
-
Chapter 8 – Active Sampling of Air
PublikacjaThis chapter reviews the literature information on analytical techniques and laboratory equipment used for active sampling of air (atmospheric and indoor) in regular monitoring research. It describes popular analytical devices applied for sample collection using various types of polymeric bags, e.g. Tedlar bags, Teflon or Nafion bags, and/or stainless steel vacuum containers. It reviews literature data about the application of...
-
Miniaturized Passive Emission Chambers for In Situ Measurement of Emissions of Volatile Organic Compounds
PublikacjaThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air. The presence of dangerous chemical compounds in indoor air can have an adverse impact on human health and cause numerous diseases of the respiratory and circulatory systems. Such harmful chemicals get into indoor air as a result of their emission from building and indoor materials....
-
Miniaturized passive emission test chamber for in-situ measurement of emissions of organic compounds
PublikacjaThe results of many different studies have demonstrated unequivocally that the quality of indoor air is often much worse than that of atmospheric air (outdoor). One of the main groups of chemical compounds present in indoor air, with proven harmfulness to health,are volatile organic compounds (VOCs). VOCs present indoor comprise a wide variety of hydrocarbons and hydrocarbons derivatives including aliphatic, aromatics, alkylbenzens,...
-
Sick building syndrome due to molds
PublikacjaThe term Sick Building Syndrome (SBS) is a combination of ailments occurring in a specific building. Building occupants complain of symptoms such as headaches and dizziness, fainting, nausea, irritation of the mucosal membranes, skin irritation and other nonspecific hypersensitivity reactions.One of the SBS causes can be molds, which are ubiquitous in the air (over 400 species). It is estimated that 30% of the health problems (related...
-
Application of passive sampling techniques as a usable tool in the field of environmental quality monitoring
PublikacjaAnalysis of literature data published for the past 20 years leads to the conclusion, that passive sampling technique has been developing very quickly and is commonly used in the field of monitoring pollutants in air, water and soil environment. The popularity of application of passive sampling techniques in analytical and environmental chemistry results from its many advantages e.g.: Simplicity in use, low costs of exploitation,...
-
Monoterpenes emissions from different samples of wood-based materials – laminated chipboards and medium-density fiberboards (MDF)
PublikacjaThe paper presents the results of studies on emission rates of monoterpenes, carried out with the use of a new type of device - Markes’ Micro-Chamber/Thermal Extractor™ (μ-CTE250). Subject of studies were different types of wood-based materials such as: laminated chipboards and medium-density fiberboards (MDF). Based on the results obtained one can conclude that the laminated chipboards may affect the indoor air quality in much...
-
Selected concentration techniques for gas chromatographic analysis of environmental samples
PublikacjaThe paper describes the role and tasks of environmental analysis and monitoring. It emphasises the leading role played by gas chromatography, especially when coupled with suitable sample preparation. This is demonstrated by some literature evidence and mainly by the author's original work on the design of sample preparation apparatus and development of GC-based methods of determination of a wide variety of organic pollutants in...
-
Influence of external walls' thermal capacitance on indoor thermal comfort
PublikacjaThe doctoral thesis presents the results of numerical investigations on the influence of walls’ thermal capacitance on indoor thermal comfort. A proper set of thermal parameters of a building structure can considerably limit the heating / cooling demand, and passively increase the indoor thermal comfort. However the effect of building thermal capacitance on indoor conditions is complex and not always beneficial. Among a great number...
-
Wpływ emisji Lotnych Związków Organicznych (LZO), na jakość powietrza w pomieszczeniach wnętrz
PublikacjaNa jakość powietrza w pomieszczeniach wnętrz (ang. Indoor Air Quality, IAQ) mają wpływ zarówno czynniki fizyczne (np. hałas, temperatura, wilgotność powietrza) jak i czynniki chemiczne (m.in. Lotne Związki Organiczne, LZO) oraz biologiczne (np. mikroorganizmy). W przypadku czynników chemicznych, istotną grupę związków stanowią głównie LZO (np. węglowodory aromatyczne, alifatyczne). Ponad połowa emisji tych związków pochodzi z materiałów...
-
Problems and challenges associated with estimating the emissions of organic compounds from indoor materials
PublikacjaFor several years intensive research has been carried out with the aim of developing a database of the types and amounts of pollutants released from indoor materials to the indoor environment. The paper discusses in detail basic problems and challenges encountered when estimating the emissions of chemical compounds released from of indoor materials. Factors affecting the validity of data obtained by using two different types of...
-
Deep Eutectic Solvents and Their Uses for Air Purification
PublikacjaChemical compounds released into the air by the activities of industrial plants and emitted from many other sources, including in households (paints, waxes, cosmetics, disinfectants, plastic (PVC) flooring), may affect the environment and human health. Thus, air purification is an important issue in the context of caring for the condition of the environment. Deep eutectic solvents (DESs) as liquids with environmentally friendly...
-
Understanding the early-stage release of volatile organic compounds from rapeseed oil during deep-frying of tubers by targeted and omics-inspired approaches using PTR-MS and gas chromatography
PublikacjaDuring deep-frying, a plethora of volatile products is emitted with the fumes. These compounds could act as oil quality indicators and change the indoor air composition leading to health risks for occupants. The presented experiments focus on deep-frying of different tubers in rapeseed oil at different frying temperatures. Here, two scenarios for real-time monitoring of volatile organic compounds (VOCs) using proton transfer reaction...
-
Co-simulation strategy of transient CFD and heat transfer in building thermal envelope based on calibrated heat transfer coefficients
PublikacjaThe paper presents a strategy to develop a fully transient numerical model of a heat transfer in building, using a transient CFD model of indoor air and a thermal envelope model, running in a co-simulation. The strategy relies on the utilization of RANS with a high-Re turbulence model and a wall function, which enables to use a coarse computational mesh limiting the computational time. Since wall functions give invalid heat transfer...
-
Natural ventilation performance of family building in cold climate during windy days
PublikacjaAdequately designed natural ventilation is the cheapest and easiest way to effectively remove indoor pollutants and keep the fresh air inside a building. A prediction of performance and effectiveness of ventilation in order to determine the design of a ventilation system can provide real and long term cost savings. The paper presents results of performance (air change rate ACH) and effectiveness (CO2 concentration in the breathing...
-
LSTM-based method for LOS/NLOS identification in an indoor environment
PublikacjaDue to the multipath propagation, harsh indoor environment significantly impacts transmitted signals which may adversely affect the quality of the radiocommunication services, with focus on the real-time ones. This negative effect may be significantly reduced (e.g. resources management and allocation) or compensated (e.g. correction of position estimation in radiolocalisation) by the LOS/NLOS identification algorithm. This paper...
-
Analysis of Accuracy of Modified Gradient Method in Indoor Radiolocalisation System
PublikacjaIn this paper a new method, called modified gradient method, has been proposed for position calculation on the basis of distance measurement in indoor environment. It is shown that well known method of position calculation such as Foy is inefficient in indoor environment. In this article is also described the indoor radiolocalisation system which was used for collecting distance measurements which were employed for further comparative...
-
Analysis of Position Calculating Methods in Indoor Environment
PublikacjaIn the paper a modified gradient method has been proposed for position calculation on basis of distance measurement in indoor environment. It is shown that the well-known Chan method of position calculation is inefficient in indoor circumstances. Author presents Chan and modified gradient methods and achieved results for each one for real measurements.
-
New Indoor Positioning Algorithm for Distance Measurements
PublikacjaIn the paper a new indoor positioning algorithm is presented. This algorithm takes into account selected features of radio wave propagation in indoor environment. This results in improvement in accuracy of calculated position estimates. A comparative analysis of this new algorithm with Chan and Foy algorithms was made and described in the paper. This comparative analysis was made with utilization of real radio distance measurements.
-
Application of Passive Samplers in Monitoring of Organic Constituents of Air
PublikacjaThe principles of passive dosimetry, which has been known for over 100 years, are finding an ever increasing use in analytical practice and are being used as a convenient technique for isolation and enrichment of analytes from various environmental media. Due to its simplicity, a variety of designs, as well as the possibility of using a number of different final determination techniques, passive dosimetry has been applied in...
-
A Review of Antennas for Indoor Positioning Systems
PublikacjaThis paper provides a review of antennas applied for indoor positioning or localization systems. The desired requirements of thoseantennas when integrated in anchor nodes (reference nodes) are discussed, according to different localization techniques and theirperformance. The described antennas will be subdivided into the following sections according to the nature of measurements:received signal strength (RSS), time of flight (ToF),...
-
Energy efficient indoor localisation for narrowband internet of things
PublikacjaThere are an increasing number of Narrow Band IoT devices being manufactured as the technology behind them develops quickly. The high co-channel interference and signal attenuation was seen in edge Narrow Band IoT devices make it challenging to guarantee the service quality of these devices. To maximize the data rate fairness of Narrow Band IoT devices, a multi-dimensional indoor localization model is devised, consisting of...
-
Utilization of a Non-Linear Error Function in a Positioning Algorithm for Distance Measurement Systems Designed for Indoor Environments
PublikacjaA new positioning algorithm for distance measurement systems is outlined herein. This algorithm utilizes a non-linear error function which allows us to improve the positioning accuracy in highly difficult indoor environments. The non-linear error function also allows us to adjust the performance of the algorithm to the particular environmental conditions. The well-known positioning algorithms have limitations, mentioned by their...
-
Position Estimation in Mixed Indoor-Outdoor Environment Using Signals of Opportunity and Deep Learning Approach
PublikacjaTo improve the user's localization estimation in indoor and outdoor environment a novel radiolocalization system using deep learning dedicated to work both in indoor and outdoor environment is proposed. It is based on the radio signatures using radio signals of opportunity from LTE an WiFi networks. The measurements of channel state estimators from LTE network and from WiFi network are taken by using the developed application....
-
Calibration-Free Single-Anchor Indoor Localization Using an ESPAR Antenna
PublikacjaIn this paper, we present a novel, low-cost approach to indoor localization that is capable of performing localization processes in real indoor environments and does not require calibration or recalibration procedures. To this end, we propose a single-anchor architecture and design based on an electronically steerable parasitic array radiator (ESPAR) antenna and Nordic Semiconductor nRF52840 utilizing Bluetooth Low Energy (BLE)...
-
Accuracy analysis of the RSSI BLE SensorTag signal for indoor localization purposes
PublikacjaIn this paper we describe possibility of use the RSSI signal (Radio Signal Strength Indication) from Texas Instruments SensorTag CC2650 for indoor positioning purposes. This idea is not a new but in our opinion it is possible to use SensorTags with Bluetooth LE wireless interface for positioning inside buildings in such applications as people findings in hospitals, senior come care, etc. RSSI is mostly selected as the sensor localization...