displaying 1000 best results Help
Search results for: optical properties
-
A new method of presosns identification based on comparative analysis of 3D face models
PublicationThe article presents the use of modern close range photogrammetry for possessing highly accurate 3D models of the human face (including the ears). Modern methods used to obtain precise data describing the construction of a human face, and even the whole human body, should allow to get finished measurement material in a very short time. Those features belong to the optical scanning technology. Comparative analysis of models of the...
-
Zastosowanie optycznej tomografii niskokoherentnej do 2-wymiarowego obrazowania cienkich warstw polimerów
PublicationW artykule omówiono zasadę działania i przedstawiono podstawowe właściwości systemu OCT (Optical Coherence Tomography). Na przykładzie folii polietylenowej przedyskutowano możliwości wykorzystania systemu do badanie wewnętrznej struktury warstwowej obiektów niebiologicznych. Przedstawiono i omówiono wyniki przeprowadzonych badań nad warstwowymi materiałami przeźroczystymi.
-
The finite difference methods of computation of X-rays propagation through a system of many lenses
PublicationThe propagation of X-ray waves through an optical system consisting of many beryllium X-ray refrac- tive lenses is considered. In order to calculate the propagation of electromagnetic in the optical sys- tem, two differential equations are considered. First equation for an electric field of a monochromatic wave and the second equation derived for complex phase of the same electric The propagation of X-ray waves through an optical system...
-
Structural and luminescent study of TeO2-BaO-Bi2O3-Ag glass system doped with Eu3+ and Dy3+ for possible color-tunable phosphor application
PublicationTellurite glass systems of 73TeO2-4BaO-3Bi2O3-1Ag:xEu2O3-(2-x)Dy2O3 (where x = 0.5, 1, 1.5, 2 in molar ratio) composition have been successfully synthesized. In order to acquire Ag nanoparticles, materials have been heat treated at 350 °C in the air atmosphere. Structural properties of obtained samples were evaluated with various techniques. X-Ray Diffraction (XRD) measurements indicated that obtained materials are amorphous in...
-
Guido: a musical score recognition system
PublicationThis paper presents an optical music recognition system Guido that can automatically recognize the main musical symbols of music scores that were scanned or taken by a digital camera. The application is based on object model of musical notation and uses linguistic approach for symbol interpretation and error correction. The system offers musical editor with a partially automatic error correction.
-
High-performance graphene-based biosensor using a metasurface of asymmetric silicon disks
PublicationIn recent years, optical biosensors widely applicable for medical applications, have received much attention. In this paper, we propose a high-performance polarization-insensitive optical biosensor based on a graphene-dielectric metasurface. The metasurface consists of an asymmetric dielectric disk array that supports a high Q-factor Fano resonance. The provided sharp Fano resonance results in an enhanced light-matter interaction...
-
Spectroscopic wireless sensor of hematocrit level
PublicationAn optical method for hematocrit measurement is presented. The sensor, designed and developed by authors, consists of a spectroscopic set-up and a microcontroller. The work of the sensor is based on measurement of intensity of two selected spectral bands. Tests confirmed the ability of the sensor to determine the hematocrit level with appropriate measurement accuracy. Measurement results can be transmitted via wireless module to...
-
Predictions of cervical cancer identification by photonic method combined with machine learning
PublicationCervical cancer is one of the most commonly appearing cancers, which early diagnosis is of greatest importance. Unfortunately, many diagnoses are based on subjective opinions of doctors—to date, there is no general measurement method with a calibrated standard. The problem can be solved with the measurement system being a fusion of an optoelectronic sensor and machine learning algorithm to provide reliable assistance for doctors...
-
Response of a New Low-Coherence Fabry-Perot Sensor to Hematocrit Levels in Human Blood
PublicationIn this paper, a low-coherence Fabry-Perot sensor with a spectrally measured signal processing response to the refractive index of liquids is presented. Optical fiber sensors are potentially capable of continuous measuring hematocrit levels in blood. Low-coherence Fabry-Perot interferometric sensors offer a robust solution, where information about the measurand is encoded in the full spectrum of light reflected from the sensing...
-
Eine Eeue Technik zur Präzisen Rissfortschrittsmessung im DCB oder im Keilversuch = A novel technique for precise crack length measurement in the DCB or wedge test
PublicationDiverse methods have been tried to study crack length, most basic relying on direct, or microscopic, observation of the crack tip position. Optical correlation, both lasermoiré and speckle interferometry, a single strain gauge and displacement sensorshave also been employed. Crack length measurement is, however, delicate. We present a novel method making use of strain gauges attached to one of the adherends.
-
Inkjet Printing of Lanthanide–Organic Frameworks for Anti-Counterfeiting Applications
PublicationPhotoluminescent lanthanide−organic frameworks (Ln-MOFs) were printed onto plastic and paper foils with a conventional inkjet printer. Ln-MOF inks were used to reproduce color images that can only be observed under UV light irradiation. This approach opens a new window for exploring Ln-MOF materials in technological applications, such as optical devices (e.g., lab-on-a-chip), as proof of authenticity for official documents.
-
Investigation of the Few‐Layer Black Phosphorus Degradation by the Photonic Measurements
PublicationFew-layer black phosphorus (FLBP) is a 2D material that gains worldwide interest for its possible applications, mainly in electronics and optoelec-tronics. However, as FLBP is prone to a degradation process under envi-ronmental conditions, there is a need for a monitoring method allowing investigation of its surface quality. Among many techniques, optoelectronic ones have unique advantages of fast response, non-contact, and non-invasive...
-
Preparation and Characterization of Microsphere ZnO ALD Coating Dedicated for the Fiber-Optic Refractive Index Sensor
PublicationWe report the fabrication of a novel fiber-optic sensor device, based on the use of a microsphere conformally coated with a thin layer of zinc oxide (ZnO) by atomic layer deposition (ALD), and its use as a refractive index sensor. The microsphere was prepared on the tip of a single-mode optical fiber, on which a conformal ZnO thin film of 200 nm was deposited using an ALD process based on diethyl zinc (DEZ) and water at 100 °C....
-
The morphology of vanadate glasses containing BaTiO3
Open Research DataThe morphology of vanadate glasses doped with BaTiO3 was measured. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated (573 K) brass...
-
Using MusicXML to evaluate accuracy of OMR Systems
PublicationIn this paper a methodology for automatic accuracy evaluation in optical music recognition (OMR) applications is proposed. Presented approach assumes using ground truth images together with digital music scores describing their content. The automatic evaluation algorithm measures differences between the tested score and the reference one, both stored in MusicXML format. Some preliminary test results of this approach are presented...
-
Application of the laser diode with central wavelength 975 nm for the therapy of neurofibroma and hemangiomas
PublicationThis paper presents newly developed dermatological laser (with central wavelength 975 nm) for application in therapies requiring deep penetration of tissue, e.g. cutaneous (dermal) neurofibroma (Recklinghausen disease) and hemangiomas. This laser can work either in pulse or continues wave mode. Laser radiation is transmitted toward the application region by optical fiber with a diameter of 0.6 mm. The compact design of the laser...
-
Concentration‐Induced Hetero‐Valent Partial‐Inverse Occupation of Infrared Phosphor
PublicationInfrared luminescent materials have evoked much attention from chemists and material scientists. Although substantial progress is made in materials design, the luminescent mechanism remains ambiguous in the complex structures, presenting major barriers to developing novel infrared luminescent materials. Herein, this study aims to deliberate a complete discussion on infrared phosphors with concentration-induced hetero-valent partial-inverse...
-
Effect of temperature change on refractive index of an egg white and yolk: a preliminary study
PublicationIn this article, the refractive index of an egg white and yolk depending on temperature in range 30 - 47 °C over 1550 nm was determined. The measurement head was constructed as fiber optic Fabry-Perot interferometer with interference between polished fiber end-face and aluminum weighing dish. The measurement setup has been made of an optical spectrum analyzer, a superluminescent diode with a central wevelength of 1550 nm, 2:1 fiber...
-
Magnetically sensitive fiber probe with nitrogen-vacancy center nanodiamonds integrated in a suspended core
PublicationEfficient collection of photoluminescence arising from spin dynamics of nitrogen vacancy (NV) centers in diamond is important for practical applications involving precise magnetic field or temperature mapping. These goals may be realized by the integration of nanodiamond particles with optical fibers and volumetric doping of the particles alongside the fiber core. That approach combines the advantages of robust axial fixation of...
-
Low-Level Aerial Photogrammetry as a Source of Supplementary Data for ALS Measurements
PublicationThe development of laser scanning technology ALS allows to make high-resolution measurements for large areas result-ing in significant reduction of costs. The main stakeholders at heights data received from the airborne laser scanning is mainly state administration. The state institutions appear among projects such as ISOK. Each point is classified in ac-cordance with the standard LAS 1.2, our research focuses on the class 6 -...
-
Design considerations for compact microstrip resonant cells dedicated to efficient branch-line miniaturization
PublicationA conventional compact microstrip resonant cell (CMRC)has been thoroughly investigated to enhance its slow-wave properties and subsequently ensure an efficient miniaturization of a microstrip circuit. The geometry of a classic CMRC has been improved in terms of slowwave effect in two progressive steps: (i) a single-element topology has been replaced with a double-element one and (ii) a high-impedance section has been refined by...
-
Induction of chirality in 4,4'-azopyridine by halogen-bonding interaction with optically active ditopic donors
PublicationOptically active ditopic halogen bond donors bearing two 4-iodotetrafluorophenyl groups were obtained by reaction of chiral diols with iodopentafluorobenzene. Co-crystallization of these donors with anti-4,4′-azopyridine afforded binary complexes containing infinite chains of the alternating component molecules connected by halogen bonds. The solid state CD measurements confirmed that complexation induces optical activity of the...
-
Niobate in silicate and phosphate glasses: Effect of glass basicity on crucible dissolution
PublicationUsing niobium crucibles for melting phosphate and silicate glasses of various modifier oxide contents, and therefore varying optical basicity (Λ), was found to result in varying dissolution rates of niobate during melting. Because of their high electronic polarizability, even small concentrations of niobates are detectable in the Raman spectra of glasses. Even less than 1 mol% Nb2O5 can be identified, as independently confirmed...
-
The new version of contact-less method for localisation of catenary contact wire – theoretical assumption
PublicationThis article presents the theoretical basic of a new version of contact-less method for localising the catenary contact wires, using the advanced video techniques and image analysis. So far, contact line diagnostic systems exploited nowadays uses the contact measuring methods with special design current collector. This solutions make it impossible to measure the contact line geometry in a static way. The proposed measurement method...
-
High Resolution Sea Ice Floe Size and Shape Data from Knox Coast, East Antarctica
PublicationThis dataset contains floe size distribution data from a very high resolution (pixel size: 0.3 m) optical satellite image of sea ice, acquired on 16 Feb. 2019 off the Knox Coast (East Antarctica). The image shows relatively small ice floes produced by wave-induced breakup of landfast ice between Mill Island and Bowman Island. The ice floes are characterised by a narrow size distribution and angular, polygonal shapes, typical...
-
Reduction of parasitic pitch variations in archival musical recordings
PublicationA new method for reducing parasitic pitch variations in archival audio recordings is presented. The method is intended for analyzing movie soundtracks recorded in optical films. It utilizes image processing for calculating and reducing effects of tape shrinkage being one of the main reasons for parasitic pitch variations in audio accompanying moving images. As long as the film tape characteristics are known the new method can be...
-
Optoelektroniczny system przestrzennego monitoringu wzbudzenia plazmy w procesach syntezy optycznych warstw diamentopodobnych
PublicationPrzedmiotem pracy jest optoelektroniczny system do badania wzbudzenia plazmy mikrofalowej w procesie syntezy warstw DLC (ang. Diamond Like-Carbon). W komunikacie zaprezentowano budowę systemu do przestrzennego monitoringu stanu wzbudzenia plazmy podczas procesu CVD. System SR-OES (ang. Spatially Resolved Optical Emission Spectroscopy) umożliwia określanie rozkładu wzbudzenia cząstek w przestrzeni komory i na tej podstawie wybrania...
-
Simultaneous opto-electrochemical monitoring of carbamazepine and its electro-oxidation by-products in wastewater
PublicationThe growing human impact on aquatic environments, due to the extensive use of pharmaceuticals and the release of persistent pollutants, makes it necessary to implement new widespread methods for the characterisation and quantification of such contaminants and relative degradation products. Carbamazepine, 5H-dibenzo[b,f]azepine-5-carboxamide, (CBZ) is a widely used anti-epileptic drug, characterised by its limited removal by conventional...
-
Light box for investigation of characteristics of optoelectronics detectors
PublicationIn this paper, a light box for investigation of characteristics of optoelectronic detectors is described. The light box consists of an illumination device, an optical power sensor and a mechanical enclosure. The illumination device is based on four types of high-power light emitting diodes (LED): white light, red, green and blue. The illumination level can be varied for each LED independently by the driver and is measured by optical...
-
Low to intermediate energy elastic electron scattering from dichloromethane (CH2Cl2)
PublicationWe report a theoretical-experimental investigation of electron scattering by dichloromethane (CH2Cl2) in the low- and intermediate energy ranges. Experimental elastic differential cross sections (DCS), in the incident electron energy range of 0.5-800 eV and scattering angle range of 10°–130°, were measured using a crossed beam relative flow technique. Integral and momentum- transfer cross sections were determined from the experimental...
-
The morphology of vanadate glass-ceramics containing BaTiO3
Open Research DataThe morphology of vanadate glass-ceramic doped with BaTiO3 was measured. Samples of the composition of x[BaO,TiO2]–(80 − x)V2O5–20Bi2O3 where x = 5, 10 and 15 in mol% were prepared by a conventional melt quenching technique. The melting was performed in alumina crucibles at the temperature of 1273 K–1373 K. The melts were poured on a preheated (573...
-
Topography of barium-vanadate glasses
Open Research DataThe topography of barium-vanadate glasses was measured. Samples of the composition of xBaO-(100-x)V2O5 where x= 30, 40 and 45 (in %mol) were prepared by the conventional melt quenching technique. Appropriate amounts of reagents: BaO (≥99.9%, P.P.H STANLAB Sp.J.) and V2O5 (≥99.9%, POCH) were thoroughly mixed in an agate mortar. The melting was performed...
-
Testing of DES toxicity towards Candida subhashii
Open Research DataDataset presents results of testing toxicity of selected DES solutions in mineral salt medium towards Candida subhashii.
-
Antifungal activity of L-homoserine O-acetyltransferase (CaMet2p) inhibitors.
Open Research DataThe dataset contains a set of optical densities at 600 nm measured at microplate reader to determine the rate of fungal growth in the presence of Candida albicans homoserine O-acetyltransferase inhibitors. Antifungal activities were determined against several strains from Candida spp. and others by the modified M27-A3 method specified by the CLSI. We...
-
A method for counting people attending large public events
PublicationThe algorithm for people counting in crowded scenes, based on the idea of virtual gate which uses optical flow method is presented. The concept and practical application of the developed algorithm under real conditions is depicted. The aim of the work is to estimate the number of people passing through entrances of a large sport hall. The most challenging problem was the unpredicted behavior of people while entering the building....
-
System for tracking multiple trains on a test railway track
PublicationSeveral problems may arise when multiple trains are to be tracked using two IP camera streams. In this work, real-life conditions are simulated using a railway track model based on the Pomeranian Metropolitan Railway (PKM). Application of automatic clustering of optical flow is investigated. A complete tracking solution is developed using background subtraction, blob analysis, Kalman filtering, and a Hungarian algorithm. In total,...
-
System for tracking multiple trains on a test railway track
PublicationSeveral problems may arise when multiple trains are to be tracked using two IP camera streams. In this work, real-life conditions are simulated using a railway track model based on the Pomeranian Metropolitan Railway (PKM). Application of automatic clustering of optical flow is investigated. A complete tracking solution is developed using background subtraction, blob analysis, Kalman filtering, and a Hungarian algorithm. In total,...
-
New Simple and Robust Method for Determination of Polarity of Deep Eutectic Solvents (DESs) by Means of Contact Angle Measurement
PublicationThe paper presents a new method for evaluating the polarity and hydrophobicity of deep eutectic solvents (DESs) based on the measurement of the DES contact angle on glass. DESs consisting of benzoic acid derivatives and quaternary ammonium chlorides–tetrabutylammonium chloride (TBAC) and benzyldimethylhexadecylammonium chloride (16-BAC)—in selected molar ratios were chosen for the study. To investigate the DESs polarity, an optical...
-
Performance Evaluation of Control Plane Functions in ASON/GMPLS Architecture
PublicationIt is assumed that demands of information society could be satisfied by architecture ASON/GMPLS comprehended as Automatically Switched Optical Network (ASON) with Generalized Multi-Protocol Label Switching (GMPLS) protocols. Introduction this solution must be preceded performance evaluation to guarantee society expectations. Practical realization is expensive and simulations models are necessary to examine standardized propositions....
-
Quality of Service in ASON/GMPLS Network with Hierarchical Control Plane Structure
PublicationThe paper presents the problem of quality of service for hierarchical control plane structure of Automatically Switched Optical Network (ASON) utilizing Generalized Multi-Protocol Label Switching (GMPLS). The approach is implemented to control the multidomain network with required quality of service, in a use case of incomplete domain network information. The authors examine different factors, including resource reservation algorithms...
-
AUTONOMOUS PLATFORM TO PROTECT MARITIME INFRASTRUCTURE FACILITIES
PublicationProblems regarding the security of maritime infrastructure, especially harbours and offshore infrastructure, are currently a very hot topic. Due to these problems, there are some research projects in which the main goal is to decrease the gap and improve the methods of observation in the chosen area, for both in-air and underwater areas. The main goal of the paper is to show a new complex system for improving the security of the...
-
Raman spectroscopic investigation of blood and related materials
PublicationThis paper reports preliminary studies on use of Raman spectroscopy for investigation of blood. High quality blood spectra were recorded in-vitro with excitation wavelengths of 830 nm. Because of complex composition of the blood as well as by light attenuation and scattering in the tissues, spectra set up from wide, low-intensive Raman bands and intensive optical background. To get information about origin of bands in Raman spectra...
-
Data obtained by numerical simulation for X-ray focusing using a finite difference method
Open Research DataThe propagation of X-ray waves through an optical system consisting of many X-ray refractive lenses is considered. For solving the problem for an electromagnetic wave, a finite-difference method is applied.
-
A prototype femtosecond laser system for MEMS fabrication
Publicationn this article, the concept of a prototype femtosecond laser micromachining system and a femtosecond solid-state Yb:KYW laser is presented. Ultrashort laser pulses have many advantages over the long pulses in laser micromachining, due to their unique ability to interact with different materials without transferring heat to them. This allows very precise and pure laser-processing, clean cuts and sharp edges. A femtosecond laser...
-
Światłowodowa koherentna tomografia optyczna (OCT) w zastosowaniach technicznych
PublicationKoherentna tomografia optyczna (ang. Optical Coherence Tomography - OCT) jest szybko rozwijającą się metodą obrazowania przekrojów wewnętrznych struktur. Pierwotnie używana do celów biomedycznych, może znaleźć szerokie zastosowanie do badań materiałowych. Jest to uniwersalna technika pomiarowa charakteryzująca się wysoką rozdzielczością (rzędu pojedynczych mikrometrów) połączoną z możliwością obrazowania optycznych ośrodków silnie...
-
The Realization of NGN Architecture for ASON/GMPLS Network
PublicationFor the last decades huge efforts of telecommunication,Internet and media organizations have been focusingon creating standards and implementing one common networkdelivering multimedia services - Next Generation Network.One of the technologies which are very likely to beused in NGN transport layer is ASON/GMPLS optical network.The implementation of ASON/GMPLS technology usingopen source software and its results are the subject...
-
Optoelectronic system for investigation of cvd diamond/DLC layers growth
PublicationDevelopment of the optoelectronic system for non-invasive monitoring of diamond/DLC (Diamond-Like-Carbon) thin films growth during μPA ECR CVD (Microwave Plasma Assisted Electron Cyclotron Resonance Chemical Vapour Deposition) process is described. The system uses multi-point Optical Emission Spectroscopy (OES) and long-working-distance Raman spectroscopy. Dissociation of H2 molecules, excitation and ionization of hydrogen atoms...
-
Modeling of light propagation in canine gingiva
PublicationThis study is a preliminary evaluation of the effectivenes of laser-based surgery of maxillary and mandibular bone in dogs. Current methods of gingivial surgery in dogs require the use of general anaesthesia.1, 2 The proposed methods of laser surgery can be performed on conscious dogs, which substantially reduces the associated risks. Two choices of lasers, Nd:YAG and a 930 nm semiconductor lasers were evaluated. The former is...
-
The changes of outlet gases concentrations from SOFC with Ce(Pr,Sm)O2-s layers
Open Research DataThe dataset includes The changes of outlet gases concentrations from SOFC with Ce(Pr,Sm)O2-s layers. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding.
-
[Chapter] 22. Application of physical modeling to study combustion process-es and flow patterns in large-scale boilers and furmaces. W: Optical me- thods and data processing in heat and fluid flow. Ed. C. Greated, J. Cos-grove, J.M. Buick. Bury St. Edmunds. London: Profess. Eng. Publ.**2002 s. 267-277, 4 rys. bibliogr. 6 poz. Zastosowanie modelowania fizycznego do badania procesów spalania pola prze- pływu w przemysłowych kotłach i piecach.
PublicationRozdział zawiera wyniki badań modelowania fizycznego dwuwymiarowego i trój-wymiarowego pola przepływu i procesów spalania w wybranych urządzeniachprzemysłowych.