wyświetlamy 1000 najlepszych wyników Pomoc
Wyniki wyszukiwania dla: MEASUREMENTS
-
A model of the response of the MGS-6 gravity sensor to tilting
PublikacjaThe reliable interpretation of the measurements made by the Micro-g marine gravimetric system (MGS-6) depends on how the temporary changes of the scale coefficients such as gravimeter scale factor, vertical cross-coupling (VCC) effect, tiltmeter cross and tiltmeter long are compensated for during the signal analysis. The listed coefficients cannot be determined from readings during the measurements or by analysing the final data....
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (2nd serie)
Dane BadawczeThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Refractive index measurement in the range of 1.3 – 1.5 for 1550 nm wavelength (1st serie)
Dane BadawczeThe low-coherence refractive index measurements of certified liquid samples provided by Cargille Labs were performed. The measurement system consisted of a broadband light source (central wavelength of 1550 nm), an optical spectrum analyzer, a 2x1 fiber-optic coupler (50:50 power split), and single-mode telecommunication optical fibers. A micromechanical...
-
Displacements of chimney in the light of computer calculations and surveying
PublikacjaThe article presents the numerical analysis of reinforced concrete chimney displacements, which was carried out geodetic measurements.
-
Short-term measurement of physiological parameters - child (2)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Luminescence of TeO2:Eu thin films
Dane BadawczeTellurium dioxide doped by europium thin films were deposited by magnetron sputtering method and simultaneously heated at 200 oC. Presence of Eu ions and their valence states was confirmed by X-ray photoemission spectroscopy measurements. The structure of the films as well as the influence of europium dopant on crystalline structure of the films was...
-
Badania i analizy kolejowych konstrukcji odciążających typu mostowego
PublikacjaW pracy przedstawiono i omówiono wybrane modele obliczeniowe, wyniki analiz teoretycznych oraz badań trzech typów kolejowych konstrukcji odciążających typu mostowego. Zaprezentowano modele obliczeniowe oraz metodykę badań in situ tego typu konbstrukcji. Przedstawiono wnioski dotyczące zaawansowanych metod obliczeniowych rozszerzonych badań in situ w celu diagnozowania rzeczywistej pracy obiektów mostowych.
-
A LABORATORY STAND FOR THE ANALYSIS OF DYNAMIC PROPERTIES OF THERMOCOUPLES
PublikacjaIn the present elaboration, problems connected with measurements of high variable temperatures of gases are introduced and the impact of dynamic properties of different construction solutions of thermoelements on the accuracy of the measurements is considered. A laboratory stand built within research under doctoral thesis, destined for analysis of dynamic properties of thermocouples is also described. Results of numerical simulation...
-
Testing the durability and function of road traffic management devices
PublikacjaTraffic management measures (vertical signs and horizontal marking, reflective elements) are used for guiding vehicles optically, indicating road mileage, marking objects in road gauge, marking vehicle and pedestrian safeguards and driver information and warning. This paper presents a synthesis of a literature study and the results of research conducted under stage one of the project LifeRoSE. The requirements for different traffic...
-
Mobile Laser Scanning Calibration on a Marine Platform
PublikacjaThe article describes the method of calibration of the Riegl VMZ-400 mobile scanning system on a floating platform and an experiment aimed at conducting measurements from a previously calibrated instrument. The issue of factors affecting the quality of measurements was discussed. Mobile laser scanning is an increasingly popular measurement solution, but it is still innovative on a European scale. The use of a floating platform...
-
Mobile application technology in levelling
PublikacjaThe topic of this article is the use of mobile application technology in geodetic measurements with an emphasis on levelling. Reference points were registered as data from levelling benchmarks, performed with a traditional dumpy level. The created application allowed the recording of measurements on location, sending them to a remote server for processing and preparing a report to be saved in a database. The project was to decrease...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 100 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 130 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 110 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Measurement spectrum obtained with the use of ZnO coated microsphere-based fiber-optic sensor - 120 Celsius degrees
Dane BadawczeApplication of a microsphere-based fiber-optic sensor with 200 nm zinc oxide (ZnO) coating, deposited by Atomic Layer Deposition (ALD) method, for temperature measurements between 100°C and 300°C, is presented. The main advantage of integrating a fiber-optic microsphere with a sensing device is the possibility of monitoring the integrity of the sensor...
-
Short-term measurement of physiological parameters - teenager (25 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (25 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (15 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - adult (20 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (20 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (10 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (15 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - adult (35 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (35 minutes) measurements of physiological parameters were performed on the healthy...
-
Electrical and noise responses of graphene back-gated field-effect transistors enhanced by UV light for organic vapors sensing
Dane BadawczeBack-gated field-effect transistors with graphene channels (GFETs) were investigated toward organic vapors sensing. Two methods were used for sensing experiments including DC characteristics measurements and fluctuation-enhanced sensing by low-frequency noise studies. The data set consists of raw and modified data on GFET responses to acetonitrile,...
-
Short-term measurement of physiological parameters - teenager (15 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (15 minutes) measurements of physiological parameters were performed on the healthy...
-
Depth profile of the gold-silver bimetallic structures
Dane BadawczeSilver and gold bimetallic layers were deposited on a silicon substrate by magnetron sputtering method. Both, Au and Ag layers had 3 nm of thickness. That prepared nanostructures were measured by XPS method. To obtain a depth profile of chemical composition, an Argon ion (Ar+) gun was used for etching surface of sample. Each cycle of etching takes 30...
-
Respiratory system modelling and simulation basing on the forced oscilation technique
PublikacjaConventional methods of testing lung functioning demand a specific respiratory action of the patient. In contrast, the forced oscillation technique (fot) provides measurements obtained with a minimal cooperation of the subject. The aim of this study is to verify the usefulness of the forced oscillation technique modelling in respiratory system diagnosing. in order to do it two models of fot measurements have been considered: the...
-
Single crystal growth and physical properties of MCo2Al9 (M= Sr, Ba)
PublikacjaSingle crystals of SrCo2Al and BaCo2Al9 were grown using a self-flux method. A LeBail analysis of the powder X-ray diffraction patterns show that both compounds crystallize in a hexagonal (P6/mmm) crystal structure with lattice parameters: a = 7.8995(1) Å, c = 3.9159(1) Å for SrCo2Al9, and a = 7.9162(2) Å, c = 3.9702(1) Å for BaCo2Al9 aluminide. The low temperature analysis of the heat capacity measurements give a Sommerfeld...
-
Fiber-optic sensors based on microspheres with nanocoatings (Zastosowanie mikrosfer optycznych z cienkowarstwowymi pokryciami w czujnikach światłowodowych)
PublikacjaTemperature is one of the most important physical quantities. Temperature measurements are used in every field of life, especially electronics, electrical engineering, energy-related fields, including energy source and storage devices. The goal of this dissertation is to design and optimize the microsphere-based fiber-optic sensors construction for measurement of the sensor surrounding medium temperature, including selection of...
-
Local electrochemical impedance spectroscopy in dynamic mode of galvanic coupling
PublikacjaA novel method that combines local electrochemical impedance spectroscopy and mapping in dynamicmode is proposed. Method was validated over two galvanic couplings, namely zinc/copper and cad-mium/copper. Impedance spectrum response for all measuring points was obtained by means ofsimultaneous implementation of selected range of frequencies. Proposed method allows the measure-ment in a more time-efficient manner, at the same time...
-
Comparison between measured and calculated underwater pressure of merchant ship
PublikacjaFrom 2012 The Polish Naval Academy take part in an international research project SIRAMIS, carried out in the framework of the European Defence Agency. The objective of this project is to improve the understanding of ship signature interaction with multi influence sensors in relevant and realistic scenario's. This paper describes selected results of the comparison results of sea trials and model calculations of the hydrodynamic...
-
Polytypism and superconductivity in the NbS2 system
PublikacjaWe report on the phase formation and the superconducting properties in the NbS2 system. Specifically, we have performed a series of standardized solid-state syntheses in this system, which allow us to establish a comprehensive synthesis map for the formation of the two polytypes 2H-NbS2 and 3R-NbS2, respectively. We show that the identification of two polytypes by means of X-ray diffraction is not always unambiguous. Our physical...
-
Radio Link Measurement Methodology for Location Service Applications
PublikacjaThe aim of this paper is the methodology of measurements executed in a radio link for the realization of radiolocation services in radiocommunication networks, particularly in cellular networks. The main results of the measurements obtained in the physical layer of the universal mobile telecommunications system (UMTS) are introduced. A new method for the utilization of the multipath propagation phenomenon to improve the estimation...
-
Mesoscopic impedance analysis of solid materials surface
PublikacjaSeveral techniques have been developed in order to characterize electrical properties of surfaces in micrometer/nanometer scale. Obtaining of the spatial distribution of sample resistance, capacitance or potential requires separate measurements performed in different scanning modes. On the other hand, analysis of the frequency response of investigated system enables determination of several physical quantities in single measurement...
-
Long-Term Measurement of Physiological Parameters – Child Dataset
PublikacjaThe dataset titled “Long-term measurement of physiological parameters – child is one dataset” of the bigger series named Long-term measurement of physiological parameters. The dataset contains physiological parameter measurements such as skin temperature and resistance, blood pulse, as well as the stress detection marker, which can have a value of 0 when there is no stress detected or 1 when stress appeared. Additionally, the dataset...
-
Person Tracking in Ultra-Wide Band Hybrid Localization System Using Reduced Number of Reference Nodes
PublikacjaIn this article a novel method of positional data integration in an indoor hybrid localization system combining inertial navigation with radio distance measurements is presented. A point of interest is the situation when the positional data and the radio distance measurements are obtained from less than thee reference nodes and it is impossible to unambiguously localize the moving person due to undetermined set of positional equations....
-
Modeling nutrient removal and energy consumption in an advanced activated sludge system under uncertainty
PublikacjaActivated sludge models are widely used to simulate, optimize and control performance of wastewater treatment plants (WWTP). For simulation of nutrient removal and energy consumption, kinetic parameters would need to be estimated, which requires an extensive measurement campaign. In this study, a novel methodology is proposed for modeling the performance and energy consumption of a biological nutrient removal activated sludge system...
-
Short-term measurement of physiological parameters - teenager (5 min) - 3.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (10 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (10 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) 7.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (20 min) 2.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (20 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (15 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (15 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (10 min)_3.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (10 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (30 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (25 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) 6.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (40 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (40 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 2.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 5.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (20 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (20 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 6.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (25 min)
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (25 minutes) measurements of physiological parameters were performed on the healthy...
-
Short-term measurement of physiological parameters - teenager (5 min) - 4.series
Dane BadawczeThe data set was obtained during the project focus on the determination of changes in physiological parameters due to a stressful situation.The measurements were conducted with the system which consists e.g. sensors of temperature, skin resistance, and pulse.Short-term (5 minutes) measurements of physiological parameters were performed on the healthy...
-
Cyclic voltammetry curves for FTO/PANI:WO3 nanocomposite
Dane BadawczeThis dataset contains the results of kinetic electrochemical studies, carried out with cyclic voltammetry (CV) of FTO/PANI:WO3 nanocomposite at various scan rates: 10, 20, 50, 75, 100 and 200 mV/s. The electrolyte was 1M H2SO4 solution. The measurements were performed in a three electrode setup, and with Ag|AgCl|3M KCl as the reference electrode and...
-
Modelling of Diffusing Capacity Measurement Results in Lung Microangiopathy Patients. A novel Diagnostic Suppport
PublikacjaLung microangiopathy is a little known negative influence of diabetes mellitus on the functioning of the lungs. The aim of this study is to design a supportive method for diagnosing lung microangiopathy. This will be based on routinely performed pulmonary measurements as well as on investigation process modelling and data processing. A model of the diffusion of oxygen from the alveoli to the blood has been described with a set...
-
Measuring and Analyzing Audio Levels in Film, Commercials, and Movie Trailers Using Leq(A) Values and the LUFS Loudness Model . Analiza pomiarów dźwięku w filmie oraz w reklamach filmowych z wykorzystaniem modelu głośności
PublikacjaThe purpose of this paper is to describe the measurement of loudness levels in movies, movie trailers, and commercials displayed before feature films at movie theaters. In the initial section, the paper discusses the issues related to measurement of loudness levels, provides recommendations regarding permissible loudness levels during movie screenings, and mentions the applied units of measurement. The following section of the...
-
Estimation of the angular position of a two-wheeled balancing robot using a real IMU with selected filters
PublikacjaA low-cost measurement system using filtering of measurements for two-wheeled balancing robot stabilisation purposes has been addressed in this paper. In particular, a measurement system based on gyroscope, accelerometer, and encoder has been considered. The measurements have been corrected for deterministic disturbances and then filtered with Kalman, α-β type, and complementary filters. A quantitative assessment of selected filters...
-
Intelligent equalizer solution employing music genre and the room characteristics analysis
PublikacjaThe paper presents an intelligent equalizer solution based on room acoustic conditions and music genre analysis. A series of acoustic characteristic measurements are performed for checking the concept proposed. White noise (reference signal) and audio excerpts belonging to six music genres are utilized as excitation signals in measurements. This results in registration of frequency responses of rooms and reverberation times. Signals...
-
Numerical modelling and experimental verification of compressible squeeze film pressure
PublikacjaThe validity of using the Reynolds equation for compressible squeeze film pressure was tested with computational fluid dynamics (CFD). A squeeze film air bearing was instrumented with pressure sensors and non-contacting displacement probes to provide transient measurements of film thickness and pressure. The film thickness measurements also provided input parameters to the numerical prediction. However, numerical results showed...
-
Suitability of LoRaWAN Technology for the Development of Maritime Applications
PublikacjaThe LoRaWAN Technology opens new possibilities for gathering and analysis of distributed data. In the paper we concentrate on its maritime usability which was tested by us in the period from June to August 2018. Measurements of the LoRaWAN network coverage in the Bay of Gdansk area were carried out. Various conditions and places were tested. The research was planned in such a way as to gradually increase the range and control the...
-
LDFEM analysis of pore water pressure development in cohesive soil due to FDP auger drilling
PublikacjaThis paper presents the preliminary modelling of FDP auger drilling in soft soil with emphasis on excess pore water pressure (EPWP) development using CEL formulation and Abaqus software suit. The EPWP generation in single points is investigated and the results of a numerical analysis are compared with the field measurements. It is found that numerical model qualitatively reflects the field measurements. However,...
-
Influence of the Delay in Monitor System on the Motor Coordination of Musicians while Performing
PublikacjaThis paper provides a description and results of measurements of the maximum acceptable value of delay tolerated by a musician, while playing an instrument, that does not cause de-synchronization and discomfort. First, methodology of measurements comprising audio recording and a fast camera is described. Then, themeasurement procedure for acquiring the maximum value of delay conditioning...
-
Fast Fading Influence on the Deep Learning-Based LOS and NLOS Identificationin Wireless Body Area Networks
PublikacjaIn the article, the fast fading influence on the proposed DL (Deep Learning) approach for LOS (Line-of-Sight) and NLOS (Non-Line-of-Sight) conditions identification in Wireless Body Area Networks is investigated. The research was conducted on the basis of the off-body communication measurements using the developed mobile measurement stand, in an indoor environment for both static and dynamic scenarios. The measurements involved...
-
Stability of borophene dispersion in water
Dane BadawczeThis dataset contains the results of the studies of stability of borophene dispersion in water (1 µg/µL) based on the measurements of absorbance of the solution using UV-VIS spectroscopy.
-
Termowizja jako narzędzie weryfikacji stanu elementów ochronnych SMD podczas badań udarowych
PublikacjaPrzedstawiono wyniki badań przyrostów temperatury rejestrowanych za pomocą kamery termowizyjnej ochronnych elementów SMD podczas wykonywania badań odporności na udary napięciowe wykonywane wg normy EN61000-4-5 dla różnych poziomów sprzężeń impedancyjnych
-
Quantum privacy witness
PublikacjaWhile it is usually known that the mean value of a single observable is enough to detect entanglement or its distillability, the counterpart of such an approach in the case of quantum privacy has been missing. Here we develop the concept of a privacy witness, i.e., a single observable that may detect the presence of the secure key even in the case of bound entanglement. Then we develop the notion of secret-key estimation based...
-
Electrohydrodynamic Secondary Flow and Particle Collection Efficiency in a One-sided Spike-plate Type Electrostatic Precipitator
PublikacjaIn this work, results of electrohydrodynamic secondary flow and particle collection efficiency measurements in an electrostatic precipitator under positive and negative voltage polarity are presented. The electrostatic precipitator had two plate collecting electrodes and a single spike discharge electrode. The spike tips were only on one side of the discharge electrode, therefore called a one-sided spike electrode. The electrohydrodynamic...
-
Usefulness of chest perfusion computed tomography in the diagnosis of diabetic pulmonary microangiopathy
PublikacjaThis paper presents the usefulness of perfusion computed tomography (pCT) in the diagnosis of diabetic pulmonary microangiopathy. Our previous works have shown that perfusion parameters are useful in the diagnosis of diabetic pulmonary microangiopathy. We are looking for such measurements and perfusion parameters that provide the most accurate diagnosis. Two types of comparison were made based on the results of clinical trials:...
-
Effect of cobalt addition on the corrosion behaviorof near equiatomic NiTi shape memory alloy in normal saline solution: electrochemical and XPS studies
PublikacjaThe electrochemical and corrosion (uniform and localized) behavior of a binary Ni52Ti48 shape memory alloy (SMA) and two ternary Ni52Ti48-xCox (x = 1.5 and 4.0 wt.%) SMAs were studied. Measurements were conducted in 0.9% NaCl solution at 37 oC employing various electrochemical methods. These include: linear polarization resistance (LPR), linear sweep voltammetry (LSV), chronoamperometry and dynamic electrochemical impedance spectroscopy...
-
The data exchange between smart glasses and healthcare information systems using the HL7 FHIR standard
PublikacjaIn this study we evaluated system architecture for the use of smart glasses as a viewer of information, as a source of medical data (vital sign measurements: temperature, pulse rate, and respiration rate), and as a filter of healthcare information. All activities were based on patient/device identification procedures using graphical markers or features based on visual appearance. The architecture and particular use cases were implemented...
-
Flicker Noise in Resistive Gas Sensors—Measurement Setups and Applications for Enhanced Gas Sensing
PublikacjaWe discuss the implementation challenges of gas sensing systems based on low-frequency noise measurements on chemoresistive sensors. Resistance fluctuations in various gas sensing materials, in a frequency range typically up to a few kHz, can enhance gas sensing by considering its intensity and the slope of power spectral density. The issues of low-frequency noise measurements in resistive gas sensors, specifically in two-dimensional...
-
The hydrogen evolution reaction (HER) performance of some FTO/MoS2/SnO2 electrodes
Dane BadawczeTo demonstrate the electrochemical performance of the FTO/MoS2/SnO2 for HER (hydrogen evolution reaction), the LSV (linear sweep voltammetry) was performed. The polarization curves of the obtained composite were measured in 1 M H2SO4 at room temperature with a scan rate 10 mV/s. For comparison, the LSV for the FTO, pure MoS2 and Pt plate electrode were...
-
Depth profile of the chemical composition of the Au-Ag multilayers
Dane BadawczeSilver and gold multilayers were deposited on a silicon substrate by magnetron sputtering method. Both type, Au and Ag thin films had 2 nm of thickness. Totally structure had thickness of 6 nm (Au-Ag-Au). That prepared multilayers were measured by XPS method. To obtain a depth profile of chemical composition, an Argon ion (Ar+) gun was used for etching...
-
XRD-TiO2 and SiO2
Dane BadawczeData contain results from XRD measurements of amorphous silica and TiO2 of antase and rutile phases. The commercial TiO2 named as P25 produced by Evonik was also analyzed.
-
Magnetic field maps of an astable multivibrator in frequency range from 30 MHz to 3 GHz – selective detection
Dane BadawczeThe data presents a result of near field measurements of electromagnetic emissions radiated from the PCB of a small electronic device. An efficient method of modelling the magnetic and electric field emissions is the measurements in the near field using electric and magnetic probes. The attached files contain magnetic field maps created on based measurements...
-
Application of gpr method in diagnostics of reinforced concrete structures
PublikacjaThis paper presents an application of the ground penetration method (GPR) for diagnostics of reinforced concrete structures. In situ measurements were conducted for three civil engineering structures: the ground floor structure, the abutment of the railway viaduct and the concrete well. The dual polarized ground penetrating radar with the antenna operating at a center frequency of 2 GHz was used for GPR surveys. Three different...
-
Polypyrrole based gas sensor for ammonia detection
PublikacjaThe nature of polypyrrole response to toxic gases does not allow using the sensor in a conventional way. The main aim of this study is to acquire the information about the concentration using different approaches: a linear approximation, a non-linear approximation and a tangent method. In this paper a two-steps procedure for sensor response measurements has been utilized. Polypyrrole films were electrochemically synthesized on...
-
Porous Phantoms Mimicking Tissues – Investigation of Optical Parameter Stability Over Time
PublikacjaIn terms of optical parameters, optical phantoms can now replace live tissues and be used to validate optical measurement methods. Therefore, whether these parameters would be maintained after storage for 6 months was examined. The absorption and scattering coefficients were obtained from the measured transmittance and reflectance measurements taken 6 months apart and then compared. All of the measurements were conducted using...
-
Determination of Mechanical Properties of P91 Steel by Means of Magnetic Barkhausen Emission
PublikacjaIn this work, an attempt at determination of mechanical properties by means of a method based on magnetic Barkhausen emission measurements was proposed. The specimens made of P91 steel were subjected to creep or plastic flow which were interrupted after a range of selected time periods in order to achieve specimens with an increasing level of strain. Subsequently, measurements of magnetic Barkhausen emission were carried out, and...
-
Protection of bridges against stray current corrosion
PublikacjaA case study of Siennicki Bridge stray current corrosion hazard is presented. A corrosion risk was caused by incorrectly designed tram line traction which goes over the bridge. No dielectric insulation between running rails and bridge steel construction was used. A variety of protection methods against stray currents are described. Characteristics of the endangered bridge were described. Impressed current cathodic protection system...
-
Determination of the content of saccharides and ethanol in samples of fermented beverages
Dane BadawczeThe data set presents the results of measurements of the content of mono- and disaccharides: glucose, maltose, fructose and ethanol in samples of beverages fermented by high performance liquid chromatography (HPLC-RID).
-
Physicochemial data of the faceted anatase TiO2 nanoparticles
Dane BadawczeRaw XRD, DR-UVvis and FTIR data of the faceted TiO2 nanoparticles, as extracted from the source files. Description of the basic measurements conditions and used quipment included in the file.
-
Pomiary skuteczności hamowania w stacjach kontroli pojazdów
PublikacjaPrzeprowadzono pomiary skuteczności hamowania w warunkach różnych stacji kontroli pojazdów. Celem przedsięwzięcia było porównanie wyników z uzyskanych pomiarów. Na tej podstawie pozyskano dane umożliwiające opracowanie założeń do koncepcji metodyki badań technicznych pojazdów zabytkowych w stacjach kontroli pojazdów.
-
Rheology studies of poly(lactic acid)-carbon black-nanodiamond composites
Dane BadawczeThis dataset contains rheology measurements carried out on new 3D printing-dedicated composites with poly-lactic acid (PLA), carbon black (CB) and nanodiamond fillers. Two types of nanodiamonds were studied: detonation nanodiamonds (DND) and boron-doped carbon nanowalls (BCNW). The investigated techniques was performed by melt mass-flow rates (MFR)....
-
New kagome prototype materials: discovery of KV3Sb5, RbV3Sb5, and CsV3Sb5
PublikacjaIn this work, we present our discovery and characterization of a new kagome prototype structure, KV3Sb5. We also present the discovery of the isostructural compounds RbV3Sb5 and CsV3Sb5. All materials exhibit a structurally perfect two-dimensional kagome net of vanadium. Density-functional theory calculations indicate that the materials are metallic, with the Fermi level in close proximity to several Dirac points. Powder and single-crystal...
-
Time window based features extraction from temperature modulated gas sensors for prediction of ammonia concentration
PublikacjaElectronic gas recognition systems, in literature commonly referred as electronic noses, enable the recognition of a type and a concentration of various volatile compounds. Typical electronic gas-analyzing device consists of four main elements, namely, gas delivery subsystem, an array of gas sensors, data acquisition and power supply circuits and data analysis software. The commercially available metal-oxide TGS sensors are widely...
-
An NO2 sensor based on WO3 thin films for automotive applications in the microwave frequency range
PublikacjaA microwave system dedicated to the detection of nitrogen dioxide in the harsh environment of the Norway highways is proposed. An optimized transmission line type of sensor coated with a tungsten trioxide thin film that changes its electrical properties under NO2 gas exposure is developed. The sensors' response (S) is given in °/GHz and it is calculated based on wideband measurements. The advantage of wideband measurements in comparison...
-
A Thermographic Measurement Approach to Assess Supercapacitor Electrical Performances
PublikacjaThis paper describes a proposal for the qualitative assessment of condition of supercapacitors based on the conducted thermographic measurements. The presented measurement stand was accompanied by the concept of methodology of performing tests. Necessary conditions, which were needed to minimize the influence of disturbing factors on the performance of thermal imaging measurements, were also indicated. Mentioned factors resulted...
-
Long-term comparative evaluation of an acoustic climate in selected schools before and after the acoustic treatment
PublikacjaThe results of long-term continuous noise measurements in two selected schools are presented in the paper. Noise characteristics were measured continuously there for approximately 16 months. Measurements started eight months prior to the acoustic treatment of the school corridors of both schools. An evaluation of the acoustic climates in both schools, before and after the acoustic treatment, was performed based on comparison of...
-
Assessment of the Steering Precision of a Hydrographic Unmanned Surface Vessel (USV) along Sounding Profiles Using a Low-Cost Multi-Global Navigation Satellite System (GNSS) Receiver Supported Autopilot
Publikacjahe performance of bathymetric measurements by traditional methods (using manned vessels) in ultra-shallow waters, i.e., lakes, rivers, and sea beaches with a depth of less than 1 m, is often difficult or, in many cases, impossible due to problems related to safe vessel maneuvering. For this reason, the use of shallow draft hydrographic Unmanned Surface Vessels (USV) appears to provide a promising alternative method for performing...
-
THERMION-C2S_10 Ionic thermoelectri effect in the phase transition in Cu2Se
Dane BadawczeThe dataset contains results of measurements of the ionic thermoelectric effect in copper selenide with Cu1.99Se and Cu1.8Se compositions. X-Ray diffraction data, SEM images and EDX spectra of the samples are also in the dataset.
-
Application of auto calibration and linearization algorithms to improve sound quality of computer devices
PublikacjaAn application of auto calibration and linearization algorithms designed for correcting acoustic characteristics of selected computer devices was presented in the paper. The functionality of the algorithms were presented for two kind of computer devices: ultrabook class computer and portable device of All-In-One type. The algorithms were adjusted for the given type of the device on the basis of series of measurements conducted...
-
Application of Maximum-Length Sequences to impulse response measurement of hydroacoustic communications systems
PublikacjaThere is a growing interest in digital transmission of telemetry data on ultrasonic waves. The dependence of signal attenuation on squared frequency, specific to the hy-droacoustic systems, induces problems that do not exist in monochromatic, narrowband radio communications systems. For adapting the transmission parameters to current propagation conditions, a precise knowledge of instantaneous changes of channel performances is...
-
Nitrogen-doped diamond thin films: potential application in Fabry-Pérot interferometer
PublikacjaIn this paper we present results of preliminary research of using nitrogen-doped diamond (NDD) films as reflective layer in Fabry-Pérot interferometer. NDD films were deposited on Si substrates by Microwave Plasma Enhanced Chemical Vapor Deposition (MPECVD) with the use of CH4, H2 and N2 gas mixtures. During deposition process methane flow rate varied while nitrogen flow was constant. We performed series of measurements which showed...
-
Electromagnetic interference frequencies prediction model of flyback converter for snubber design
PublikacjaSnubber design for flyback converters usually requires experimental prototype measurements or simulation based on accurate and complex models. In this study simplified circuit modelling of a flyback converter has been described to dimension snubbers in early stage of design process. Simulation based prediction of the transistor and diode ringing frequencies has been validated by measurements in a prototype setup. In that way obtained...
-
Lokalizacja osób w środowisku promu pasażerskiego z wykorzystaniem ultra szerokopasmowego interfejsu radiowego
PublikacjaW niniejszym artykule przedstawiono badania efektywności lokalizowania poruszających się osób w środowisku promu pasażerskiego stosując pomiar czasu propagacji ultraszerokopasmowego sygnału radiowego UWB (Ultra-Wide Band) pomiędzy węzłami odniesienia i terminalem ruchomym. Opisano zbudowane stanowisko badawcze oraz uzyskane wyniki pomiarów przeprowadzonych w warunkach rzeczywistych.
-
Linear impedance of 5(2Bi2O3-V2O5)-95SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Dane BadawczeThe linear electrcial properties of 5(2Bi2O3-V2O5)-95SrB4O7 glass was measured by impedance spectroscopy method.
-
XRD patterns of MXenes catalysts
Dane BadawczeData contain results from XRD measurements of the Ti3C2Tx MXenes produced via acidic etching aluminum from MAX Phase (Ti3C2-Al-Ti3C2-Al-Ti3C2) using different etching agents, HF/HCl and HF/H2SO4 with different weight ratios (1:3, 1:4, and 1:5). The samples were labeled as MXene HF/HCl X:Y and MXene HF/H2SO4 X:Y, where X:Y means the acids weight ratios....
-
SEM images of MXene catalysts
Dane BadawczeData contain results SEM measurements of the Ti3C2Tx MXenes produced via acidic etching aluminum from MAX Phase (Ti3C2-Al-Ti3C2-Al-Ti3C2) using different etching agents, HF/HCl and HF/H2SO4 with different weight ratios (1:3, 1:4, and 1:5). The samples were labeled as MXene HF/HCl X:Y and MXene HF/H2SO4 X:Y, where X:Y means the acids weight ratios. MAX...
-
Linear impedance of Bi2VO5.5 glass-ceramic measured with impedance spectroscopy method at low temperature region
Dane BadawczeThe linear electrical properties of Bi2VO5.5 glass-ceramic prepared by traditional melt quenching technique was measured by impedance spectroscopy method.
-
FTIR spectra of gas mixtures from the process of biogas dry reforming using CLO catalyst
Dane BadawczeThe dataset contains the FTIR spectra collected during the catalytic measurements of dry reforming of biogas (60/40 CH4-CO2) using Ce0.8La0.2O2 nanocatalyst. The specatra were collected every 1 minute.
-
FTIR spectra of SOFC with LSCNT layer fueled by biogas mixture at 750 C (pure)
Dane BadawczeThe dataset contains the FTIR spectra collected during the electrical measurements DIR-SOFC with LSCNT layer. The SOFC was reduced at 800degC in H2 prior to mesurements. The spectra were collected every 10 min.
-
FTIR spectra of gas mixtures from the process of biogas dry reforming using alumina catalyst - blank
Dane BadawczeThe dataset contains the FTIR spectra collected during the catalytic measurements of blank sample Al2O3 for dry reforming of biogas (60/40 CH4-CO2). The specatra were collected every 1 minute.