Publikacje
Filtry
wszystkich: 226
Katalog Publikacji
Rok 2018
-
A case study of odour nuisance evaluation in the context of integrated urban planning
PublikacjaOdour nuisance poses a serious problem in many urban areas, yet its evaluation and mitigation is often omitted in the urban planning process. By identifying its range and spatio-temporal variations, it could be taken into consideration by planners in urban development strategies and land use decisions. The aim of the study was to present the application of odour evaluation techniques in the improvement of the quality of life in...
-
A new method for real-time monitoring of volatiles in frying fumes using proton transfer reaction mass spectrometry with time-of-flight analyse
PublikacjaTo safeguard the consumers’ well-being, it is necessary to develop novel methods for determination of carcinogens in food, including volatiles generated during frying. The currently used procedures for analysis of volatile fraction of vegetable oils are not based on real-time measurements and thus do not enable the determination of carcinogenic compounds in frying fumes; instead, only the headspace or liquid fraction is sampled....
-
Advances in olfaction-inspired biomaterials applied to bioelectronic noses
PublikacjaAmong all the senses, olfactory system of mammals is the least characterised as far as the mechanisms of odour identification are concerned. The results of recent investigations allow better understanding of the operation mechanism of the sense of smell. Progress in this field is crucial for the development of sensor technology based on olfaction-inspired biomaterials, which simulate the olfactory system of the biological counterparts....
-
AKTUALNY STAN PRAWNY W ZAKRESIE PRZECIWDZIAŁANIA UCIĄŻLIWOŚCIOM ZAPACHOWYM
PublikacjaW Polsce w ostatnich latach rośnie liczba skarg zgłaszanych organom Inspekcji Ochrony Środowiska ze względu na uciążliwość zapachową, towarzysząca działalności wielu zakładów przemysłowych i obiektów gospodarki komunalnej. Wynika to m.in. z rozwoju gospodarczego, rozbudowy miast, a także wzrostu świadomości społecznej. Rozwój metod monitorowania i kontroli stanu powietrza atmosferycznego w coraz większym zakresie umożliwia identyfikację...
-
Analysis of odour interactions in model gas mixtures using electronic nose and fuzzy logic
PublikacjaMeasurement and monitoring of air quality in terms of odour nuisance is an important problem. Although the source of these nuisances is different (e.g. wastewater treatment plants, municipal landfills), their common feature is that they are a complex mixture of odorants with different odour thresholds. An additional problem is occurrence of the odour interactions between mixture components. From a practical point of view, it would...
-
Application of Electronic Nose to Ambient Air Quality Evaluation With Respect to Odour Nuisance in Vicinity of Municipal Landfills and Sewage Treatment
PublikacjaThis chapter contains information about application of the electronic nose type instruments to evaluation of ambient air odour quality connected with such sectors of human activity as municipal landfills or sewage treatment plants. The authors present potential sources of emission from these sectors, characterize the chemical compounds responsible for presence of unpleasant odours, describe the influence of those compounds on human...
-
Application of electronic nose to effectiveness monitoring of air contaminated with toluene vapors biofiltration process
PublikacjaThe research presents the application of electronic nose (combined with MLR model) to on-line effectiveness monitoring of biofiltration of air contaminated with hydrophobic, odorous compound (toluene vapors). The research was conducted using two-section biotrickling filter inhabited by Candida environmental isolates. Gas chromatography was used as the comparative technique to obtain reliable quantification of toluene concentration...
-
Application of fuzzy logic to determine the odour intensity of model gas mixtures using electronic nose
PublikacjaThe paper presents the possibility of application of fuzzy logic to determine the odour intensity of model, ternary gas mixtures (α-pinene, toluene and triethylamine) using electronic nose prototype. The results obtained using fuzzy logic algorithms were compared with the values obtained using multiple linear regression (MLR) model and sensory analysis. As the results of the studies, it was found the electronic nose prototype along...
-
Complementary use of GCxGC–TOF–MS and statistics for differentiation of variety in biosolid samples
PublikacjaFormation of biosolid cakes, which are one of the main wastes generated in wastewater treatment plants, is connected with emission of many hazardous chemical compounds, including odoriferous ones. To optimize particular processes of biosolid cake processing, it is necessary to assess chemical composition of the gas mixtures containing the compounds released from the cakes. The paper proposes application of two-dimensional gas chromatography...
-
Complementary Use of Multi-dimensional Gas Chromatography and Proton Transfer Reaction Mass Spectrometry for Identification of Rapeseed Oil Quality Indicators
PublikacjaThe change of concentration of various volatiles generated during frying may be an indicator of oil quality. Chemical compounds such as aldehydes, ketones, alcohols and carboxyl acids are the products of oxidation during thermal degradation of edible oils. Shown in this work is a complementary use of GC×GC-TOFMS and PTR-MS for the detection and determination of quality indicators of rapeseed oil. The former technique was used for...
-
Determination of Odour Interactions in Gaseous Mixtures Using Electronic Nose Methods with Artificial Neural Networks
PublikacjaThis paper presents application of an electronic nose prototype comprised of eight sensors, five TGS-type sensors, two electrochemical sensors and one PID-type sensor, to identify odour interaction phenomenon in two-, three-, four- and five-component odorous mixtures. Typical chemical compounds, such as toluene, acetone, triethylamine, α-pinene and n-butanol, present near municipal landfills and sewage treatment plants were subjected...
-
Discrimination of selected fungi species based on their odour profile using prototypes of electronic nose instruments
PublikacjaThe paper presents practical application of an electronic nose technique to fast and efficient discrimination of the samples of different fungi species such as: Penicillium chrysogenum, Cladosporium herbarum, Rhizopus oryzae, Alternaria alternata. Two prototypes of electronic nose instrument were utilized for investigation of discrimination capability with respect to odour profile of these fungi: the first prototype was based on...
-
Effective Decision-Making in Supply Chain Management
PublikacjaProper decision-making in Supply Chain Management (SCM) is crucial for an appropriately functioning mechanisms. The paper presents how IT technologies can impact on an organization and process realization. Especially Service Oriented Architecture (SOA) standard and the Cloud Computing (CC) paradigms are taken into account. A general model of decision-making is proposed and based on a specific practical example is analyzed using...
-
Electronic Noses for Indoor Air Quality Assessment
PublikacjaThis chapter presents a proposal of the use of electronic noses in the monitoring of indoor air quality. The main focus is put on the detailed characteristics of today’s indoor air quality control methods, the types of pollution in the air, and the development of electronic noses for air testing. Currently, scientists seek methodological and structural solutions that would enable real-time online indoor air control. It has been...
-
Electronic noses in classification and quality control of edible oils: A review
PublikacjaThe growing demand for wholesome and nutritious food leads to intensification of production, which in turn can have a detrimental effect on quality and well-being of consumers. For that reason, it is important to develop novel methods of food control which would be characterized by a short time of analysis, adequate sensitivity and relatively low cost. One such technique involves the use of multi-sensory devices called electronic...
-
Elektrorozpylanie - dogodny sposób jonizacji analitów w przypadku stosowania bezpośrednich procedur pomiarowych opartych na wykorzystaniu spektrometrii mas
PublikacjaSpektrometria mas stanowi obecnie jedno z najważniejszych narzędzi analitycznych, stosowanych w celu oznaczania analitów występujących w próbkach o różnym pochodzeniu i składzie (próbki biologiczne, środowiskowe, żywność). Stosowanie tej techniki w sprzężeniu z rozdzielaniem chromatograficznym jest rozwiązaniem powszechnie stosowanym jednak w większości przypadków zachodzi konieczność oczyszczania, izolacji i wzbogacania analitów...
-
Evaluation of Three Peptide Immobilization Techniques on a QCM Surface Related to Acetaldehyde Responses in the Gas Phase
PublikacjaThe quartz-crystal microbalance is a sensitive and universal tool for measuring concentrations of various gases in the air. Biochemical functionalization of the QCM electrode allows a label-free detection of specific molecular interactions with high sensitivity and specificity. In addition, it enables a real-time determination of its kinetic rates and affinity constants. This makes QCM a versatile bioanalytical screening tool for...
Rok 2019
-
A Highly Selective Biosensor Based on Peptide Directly Derived from the HarmOBP7 Aldehyde Binding Site
PublikacjaThis paper presents the results of research on determining the optimal length of a peptide chain to eectively bind octanal molecules. Peptides that map the aldehyde binding site in HarmOBP7 were immobilized on piezoelectric transducers. Based on computational studies, four Odorant Binding Protein-derived Peptides (OBPPs) with dierent sequences were selected. Molecular modelling results of ligand docking with selected peptides were...
-
Alternative methods for dark fermentation course analysis
PublikacjaDark fermentation course analysis is crucial, as complexed matrix of gaseous components may be formed and revealed during the process. The paper considers key issues related to the microbiological process in which complex organic substances are transformed into hydrogen. For the purposes of hydrogen generation, the application of wastewater mixed sludge pre-treated according to Faloye method (Faloye et al. in Int J Hydrog Energy...
-
Biotrickling filtration of n-butanol vapors: process monitoring using electronic nose and artificial neural network
PublikacjaBiotrickling filtration is one of the techniques used to reduce odorants in the air. It is based on the aerobic degradation of pollutants by microorganisms located in the filter bed. The research presents the possibility of using the electronic nose prototype combined with artificial neural network for biofiltration process monitoring in terms of reduction in n-butanol concentration and odour intensity of treated air. The study...
-
Comparative Evaluation of Selected Biological Methods for the Removal of Hydrophilic and Hydrophobic Odorous VOCs from Air
PublikacjaDue to increasingly stringent legal regulations as well as increasing social awareness, the removal of odorous volatile organic compounds (VOCs) from air is gaining importance. This paper presents the strategy to compare selected biological methods intended for the removal of different air pollutants, especially of odorous character. Biofiltration, biotrickling filtration and bioscrubbing technologies are evaluated in terms of...
-
Critical review of electronic nose and tongue instruments prospects in pharmaceutical analysis
PublikacjaElectronic nose (enose, EN) and electronic tongue (etongue, ET) have been designed to simulate human senses of smell and taste in the best possible way. The signals acquired from a sensor array, combined with suitable data analysis system, are the basis for holistic analysis of samples. The efficiency of these instruments, regarding classification, discrimination, detection, monitoring and analytics of samples in different types...
-
Determination of Odor Intensity of Binary Gas Mixtures Using Perceptual Models and an Electronic Nose Combined with Fuzzy Logic
PublikacjaMeasurement and monitoring of air quality in terms of odor nuisance is an important problem. From a practical point of view, it would be most valuable to directly link the odor intensity with the results of analytical air monitoring. Such a solution is offered by electronic noses, which thanks to the possibility of holistic analysis of the gas sample, allow estimation of the odor intensity of the gas mixture. The biggest problem...
-
Effects of n-butanol presence, inlet loading, empty bed residence time and starvation periods on the performance of a biotrickling filter removing cyclohexane vapors from air
PublikacjaThis paper presents the results of investigations on the removal of cyclohexane vapors from air using a peat-perlite packed biotrickling filter. Effects of basic process parameters i.e. IL (inlet loading) and EBRT (empty bed residence time) as well as introduction of n-butanol to the treated air stream and starvation periods on the process performance were evaluated. The results show that the introduction of hydrophilic n-butanol...
-
Electronic Noses in Medical Diagnostics
PublikacjaElectronic nose technology is being developed in order to identify aromas in a way parallel to the biologic olfaction. When applied to the field of medicine, such device should be able to identify and discriminate between different diseases. In recent years this kind of approach finds application in medical diagnostics, and especially in disease screening. Despite the fact that devices utilizing chemical sensor arrays are not routinely...
-
Evaluation of Health Hazard Due to Emission of Volatile Organic Compounds from Various Processing Units of Wastewater Treatment Plant
PublikacjaThe paper describes an attempt at health risk assessment and odour concentration determination in the most important units of a wastewater treatment plant. The cancer risk (CR) and hazard index (HI) parameters in selected measurement locations were calculated based on the results of chromatographic analyses (GCxGC-TOF-MS) and the United States Environmental Protection Agency (US EPA) guidelines. No exceedance of the CR and HI acceptable...
Rok 2011
-
A prototype of electrochemical sensor for measurement of carbonyl compounds in air
PublikacjaThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde and formaldehyde in air. Sensitivity, limit of quantification and coefficient of selectivity of the sensor have been determined as a function of membrane thickness and electrode type using square wave voltammetry (SWV) technique. The working and counter electrodes were made of platinum and gold. Ionic liquids 1-hexyl, 3-methylimidazolium...
-
Comparison of the tests for equivalence of the measurement methods for measurement of PM10 dust in ambient air
PublikacjaThe paper presents the motives for conducting the equivalence tests and the reasons of discrepancies between the results of PM10 dust concentration obtained via the reference method and the methods based on 'on-site' measurement. The reference and non-reference methods of measurement of PM10 dust concentration in air have been discussed. Field tests for equivalence, following the Polish standard and the European Union (EU) guidelines,...
-
Effect of oxygenation time on signal of a sensor based on ionic liquids
PublikacjaThe paper presents an oxygen sensor based on ionic liquids and solid electrodes. The following ionic liquids have been employed: [BMIM][BF4], [HMIM][Cl], [BMIM][N(CN2)]. Minimum time of the sensor exposure to analyte, after which the signal (current intensity) was stable, has been evaluated. An impact of volumetric flow rate of analyte on the sensor exposure time and signal has been determined. A product of permeability coefficient...
Rok 2022
-
A state of the art review on the use of fungi in biofiltration to remove volatile hydrophobic pollutants
PublikacjaThe physical/chemical abatement of gas pollutants creates many technical problems, is costly and entails significant environmental impacts. Biological purification of off-gases is a cheap and ecologically safe way of neutralization of gas pollutants. Despite the recent advances, the main technological challenge nowadays is the purification of volatile organic compounds (VOCs) of hydrophobic character due to their low solubility...
-
Application of a Gas Sensor Array to Effectiveness Monitoring of Air Contaminated with Toluene Vapors Absorption Process
PublikacjaThis article demonstrates the application of a gas sensor array to monitor the effectiveness of the absorption process of air stream purification from odorous compounds (toluene vapors). A self-constructed matrix consisting of five commercially available gas sensors was used. Multiple linear regression (MLR) was selected as the statistical technique used to calibrate the matrice. Gas chromatography coupled with a flame ionization...
-
Deep Eutectic Solvents and Their Uses for Air Purification
PublikacjaChemical compounds released into the air by the activities of industrial plants and emitted from many other sources, including in households (paints, waxes, cosmetics, disinfectants, plastic (PVC) flooring), may affect the environment and human health. Thus, air purification is an important issue in the context of caring for the condition of the environment. Deep eutectic solvents (DESs) as liquids with environmentally friendly...
-
Determination of Odor Air Quality Index (OAQII) Using Gas Sensor Matrix
PublikacjaThis article presents a new way to determine odor nuisance based on the proposed odor air quality index (OAQII), using an instrumental method. This indicator relates the most important odor features, such as intensity, hedonic tone and odor concentration. The research was conducted at the compost screening yard of the municipal treatment plant in Central Poland, on which a self-constructed gas sensor array was placed. It consisted...
-
Developing the Urban Blue-Green Infrastructure as a Tool for Urban Air Quality Management
PublikacjaUrban structure is an important factor that shapes the process of urban ventilation and pollution dispersion. With proper planning of the urban spatial layout, city breathability can be effectively regulated, contributing to urban air quality improvement. This paper investigates the development and current management of urban systems of green and open spaces in four Polish cities: Gda ´nsk, Warsaw, Pozna ´n and Wrocław, with a...
-
Development and Assessment of Regeneration Methods for Peptide-Based QCM Biosensors in VOCs Analysis Applications
PublikacjaCleaning a quartz crystal microbalance (QCM) plays a crucial role in the regeneration of its biosensors for reuse. Imprecise removal of a receptor layer from a transducer’s surface can lead to unsteady operation during measurements. This article compares three approaches to regeneration of the piezoelectric transducers using the electrochemical, oxygen plasma and Piranha solution methods. Optimization of the cleaning method allowed...
-
Efficient Extraction of Fermentation Inhibitors by Means of Green Hydrophobic Deep Eutectic Solvents
PublikacjaThe methods for hydrogen yield efficiency improvements, the gaseous stream purification in gaseous biofuels generation, and the biomass pretreatment are considered as the main trends in research devoted to gaseous biofuel production. The environmental aspect related to the liquid stream purification arises. Moreover, the management of post-fermentation broth with the application of various biorefining techniques gains importance....
-
Electronic nose algorithm design using classical system identification for odour intensity detection
PublikacjaThe two elements considered crucial for constructing an efficient environmental odour intensity monitoring systems are sensors and algorithms typically addressed to as electronic nose sensor (e-nose). Due to operational complexity of biochemical sensors developed in human bodies algorithms based on computational methods of artificial intelligence are typically considered superior to classical model based approaches in development...
Rok 2007
-
Amperometryczne czujniki gazów z membraną nafionową
PublikacjaW pracy przedstawiono krótki przegląd najnowszych osiągnięć w dziedzinie konstrukcji amperometrycznych czujników gazów, w szczególności z membranami wykonanymi z polimerów przewodzących. Dokonano oceny wpływu niektórych parametrów na właściwości metrologiczne tego rodzaju czujników na przykładzie czujnika ditlenku siarki, także w oparciu o wyniki badań własnych prototypów czujników.
Rok 2012
-
Analiza modalna konstrukcji stanowiska badawczego dynamiki małogabarytowych wirników przy wykorzystaniu wzbudników drgań. cz. I. badania eksperymentalne.
Publikacjastreszczenie: w artykule przedstawiono przebieg i wyniki eksperymentalnej analizy modalnej konstrukcji stanowiska do badania wirników małogabarytowych, które miały w drugiej części pracy posłużyć do weryfikacji stworzonego modelu symulacyjnego. wymuszeniem były dwa wzbudniki drgań, modułem akwizycji danych był scadas mobile, a środowiskiem, w którym pracowano był test.lab 11 b. obiekt badań podwieszono na elastycznych linach by...
-
Comparative field test for measurement of PM10 dust in atmospheric air using gravimetric (reference) method and b-absorption method (Eberline FH 62-1)
PublikacjaThe paper presents the results of a field test carried out in Gdansk region between 01-01-2010 and 31-12-2010 in order to demonstrate equivalence of the Eberline FH 62-1 sampler to the reference gravimetric method of suspended PM10 dust measurement. The differences in PM10 dust concentration provided by both methods have been discussed for different seasons of the year. A method of estimation of the correction factors/correction...
-
Electronic nose as a tool for differentiation of volatile organic compounds = Elektroniczny nos jako instrument do rozróżniania lotnych związków organicznych
PublikacjaW pracy porównano dwie metody analizy zapachów lotnych związków organicznych: klasyczną analizę opartą na percepcji ludzkiego węchu i technikę elektronicznego nosa. W przeprowadzonych badaniach za pomocą klasycznej analizy brało udział 8 ochotników w okresie 2 tygodni. Do instrumentalnej metody analizy zapachu wykorzystano zaprojektowany przez autorów prototypowy 6-cio czujnikowy elektroniczny nos. Przeprowadzone badania z wykorzystaniem...
-
Elektrochemiczny czujnik na bazie cieczy jonowej do oznaczania par benzaldehydu
PublikacjaW pracy przedstawiono prototypowy, laboratoryjny, elektrochemiczny czujnik do oznaczania par benzaldehydu w argonie. Cieczą jonową testowaną jako elektrolit i środowisko reakcji redox była: bis(trifluorometylosulfonylo)imidek 1-butylo,3-metyloimidazolinowy ([BMIM][Tf2N]). W pomiarach użyto komercyjnych elektrod firm: DropSens Co. i BVT Technologies. Walidacji poddano dwa parametry metrologiczne czujnika: granicę wykrywalności i...
-
Elektrochemiczny gazowy czujnik na bazie cieczy jonowej do oznaczania benzaldehydu
PublikacjaW pracy przedstawiono wyniki badań dotyczące opracowania dwóch wersji prototypowego, laboratoryjnego elektrochemicznego czujnika do oznaczania par benzaldehydu. Elektrolitem w tych czujnikach była ciecz jonowa [HMIM][Tf2N] (bis(trifluorometylosulfonylo)imidek 1-heksylo,3-metyloimidazolinowy). Jeden z czujników zbudowany był wg koncepcji Clarka z membraną PDMS, drugi z użyciem komercyjnych elektrod firmy DropSens Co. W obu wersjach,...
-
Equivalence of on-line and reference methods for measurement of pm10 = Równoważność metod pomiarowych on-line i odniesienia stosowanych do oznaczania pm10
PublikacjaW badaniach nad równoważnością wyników otrzymanych za pomocą pomiaru ciągłego PM10 w stosunku do metody odniesienia stosuje się nienormatywny przewodnik unijny "Demonstration of Equivalence of Ambient Air Monitoring Methods. EC Working Group on Guidance for the Demonstration of Equivalence". W pracy omówiono sposób postępowania wg tego przewodnika. Na podstawie testu terenowego przeprowadzonego na terenie Gdańska w latach 2010-2011...
Rok 2017
-
Analysis of odor interactions in ternary gas mixtures using electronic nose
PublikacjaIn recent years there has been a noticeable increase in interest in the use of electronic noses in analytical chemistry. These devices perform a holistic analysis of the gas mixtures composition, without the separation and identification of its individual components. For this reason e-noses are increasingly replacing the conventional olfactometers, due to the significantly shorter analysis time and possible automation. In the work...
-
Bioelectronic nose: Current status and perspectives
PublikacjaA characteristic feature of human and animal organs of smell is the ability to identify hundreds of thousands of odours. It is accompanied by particular smell sensations, which are a basic source of information about odour mixture. The main structural elements of biological smell systems are the olfactory receptors. Small differences in a structure of odorous molecules (odorants) can lead to significant change of odour, which is...
-
Currently Commercially Available Chemical Sensors Employed for Detection of Volatile Organic Compounds in Outdoor and Indoor Air
PublikacjaThe paper presents principle of operation and design of the most popular chemical sensors for measurement of volatile organic compounds (VOCs) in outdoor and indoor air. It describes the sensors for evaluation of explosion risk including pellistors and IR-absorption sensors as well as the sensors for detection of toxic compounds such as electrochemical (amperometric), photoionization and semiconductor with solid electrolyte ones....
-
Determination of odour concentration by TD-GC×GC–TOF-MS and field olfactometry techniques
PublikacjaField olfactometry is one of the sensory techniques used to determine odour concentration, in atmospheric air, directly in emission sources. A two-dimensional gas chromatography with time of flight mass spectrometer (GC×GC–TOF-MS) allows performing the chemical characterization of various groups of chemical compounds, even in complex mixtures. Application of these techniques enabled determination of odour concentration level in...
-
Determination of Odour Interactions of Three-Component Gas Mixtures Using an Electronic Nose
PublikacjaThe paper presents an application of an electronic nose prototype comprised of six TGS-type sensors and one PID-type sensor to identify odour interaction phenomena in odorous three-component mixtures. The investigation encompassed eight odorous mixtures—toluene-acetone-triethylamine and formaldehyde-butyric acid-pinene — characterized by different odour intensity and hedonic tone. A principal component regression (PCR) calibration...
-
Different Ways to Apply a Measurement Instrument of E-Nose Type to Evaluate Ambient Air Quality with Respect to Odour Nuisance in a Vicinity of Municipal Processing Plants
PublikacjaThis review paper presents different ways to apply a measurement instrument of e-nose type to evaluate ambient air with respect to detection of the odorants characterized by unpleasant odour in a vicinity of municipal processing plants. An emphasis was put on the following applications of the electronic nose instruments: monitoring networks, remote controlled robots and drones as well as portable devices. Moreover, this paper presents...
-
Direct Analysis of Samples of Various Origin and Composition Using Specific Types of Mass Spectrometry
PublikacjaOne of the major sources of error that occur during chemical analysis utilizing the more conventional and established analytical techniques is the possibility of losing part of the analytes during the sample preparation stage. Unfortunately, this sample preparation stage is required to improve analytical sensitivity and precision. Direct techniques have helped to shorten or even bypass the sample preparation stage; and in this...
-
Direct measurements of odorous volatile organic compounds present in biosolids cakes by Proton Transfer Reaction – Mass Spectrometry Technique
PublikacjaThis paper show the results of investigation of concentration of odorous chemical compounds emitted upon ageing of anaerobically stabilised biosolids that could contribute to the overall odour character of nuisance emissions. Biosolids samples from wastewater treatment plant were collected in spring time. Concentrations of volatile organic compounds using a US EPA flux hood and Proton Transfer Reaction-Time of Flight-Mass Spectrometry...
-
Dynamic Headspace Sampling as an Initial Step for Sample Preparation in Chromatographic Analysis
PublikacjaThis work represents a brief summary of the use of dynamic headspace (DHS) as a technique for sample preparation in chromatographic analysis. Despite numerous developments in the area of analyte isolation and enrichment, DHS remains one of the fundamental methods used with GC. In our opinion, interest in this technique will not diminish significantly because it conforms to stipulations of green analytical chemistry. Moreover, DHS...
-
Electronic noses: Powerful tools in meat quality assessment
PublikacjaMain factors that are considered by consumers when choosing meat products are colour and aroma, of which the latter is a more reliable indicator of quality. However, a simple sensory evaluation of hedonistic qualities is often not sufficient to determine whether protein is past its shelf life, and consumption of spoiled meat can lead to serious health hazards. Some volatile compounds can be used as spoilage indicators, and so a...
-
ENTERPRISE ACTIVITIES MODELING BY BPMN NOTATION
PublikacjaDepending on the process behavior, available know-how and organizational goals, different techniques and tools can be used for business process modeling. We concentrate on e-commerce, and try to find the best marketing strategy for the sales process improvement. In the paper we present the multilayer approach to define enterprise scenarios. This allows us to collect the suitable knowledge necessary for enterprise analysis and improvement....
Rok 2006
-
Analytical characteristics of a new amperometric sulfur dioxide sensor
PublikacjaZaprojektowano i skonstruowano wyposażony w układ trójelektrodowy amperometryczny czujnik ditlenku siarki. Elektroda pracująca czujnika była napylona bezpośrednio na powierzchnię membrany. Zbadano charakterystyki czujnika z membranami z mikroporowatego Teflonu oraz Nafionu. Porównano parametry statyczne i dynamiczne tych czujników wypełnionych roztworami elektrolitów wewnętrznych, zawierających dodatek dimetylosulfotlenku.
-
Badania nowego czujnika wilgotności z filmem polimerowym
PublikacjaW pracy przedstawione zostały wyniki pomiarów widm impedancji czujników wilgotności z epoksydowymi filmami polimerowymi, zawierającymi czułe na wilgoć czwartorzędowe sole amoniowe. Filmy spreparowano z polietylenoiminy (PEI), usieciowanej przy pomocy eteru diglicydylowego 1,4-butanodiolu (BDDGE) z dodatkiem chlorku trójmetyloamoniowoglicydylowego (GTMAC).
-
Badania parametrów metrologicznych amperometrycznego czujnika ditlenku siarki
PublikacjaW pracy porównano właściwości dwóch nowych prototypowych wersji amperometrycznego czujnika ditlenku siarki, wyposażonego w elektrody robocze wykonane w postaci warstw złota i platyny napylonych bezpośrednio na zewnętrzną powierzchnię membrany nafionowej. Elektrolitami wewnętrznymi były wodne roztwory kwasu siarkowego z dodatkiem dimetylosulfotlenku.
Rok 2014
-
Application of an Electronic Nose Instrument to Fast Classification of Polish Honey Types
PublikacjaThe paper presents practical utilization of an electronic nose prototype, based on the FIGARO semiconductor sensors, in fast classification of Polish honey types—acacia flower, linden flower, rape, buckwheat and honeydew ones. A set of thermostating modules of the prototype provided gradient temperature characteristics of barbotage-prepared gas mixtures and stable measurement conditions. Three chemometric data analysis methods...
-
Comparison of different types of electronic nose instruments for evaluation of odour nuisance from landfill
PublikacjaThe paper presents and compares the results of investigation on classification of atmospheric air samples collected in a vicinity of municipal landfill with respect to their odour nuisance. The research was conducted using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with six semiconductor sensors of TGS type. Classification of the air...
-
Comparison of Quality Evaluation of Agricultural Distillates Using Prototype of Electronic Nose and Fast/Flash GC
PublikacjaThe paper presents the results of investigation on quality evaluation of agricultural distillates using a prototype of electronic nose instrument and a commercial electronic nose of Fast/Flash GC type – HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co.. In case of the prototype volatile fraction of the agricultural distillate was prepared via barbotage process. HERACLES II analysed the...
Rok 2016
-
Application of electrochemical sensors and sensor matrixes for measurement of odorous chemical compounds
PublikacjaIn this paper describes the principle of operation of the electrochemical sensors and the sensor matrixes comprised of electrochemical sensors intended for measurement of odorous compounds. Critical comparison of these sensors’ advantages and disadvantages has been made. The fields of economy contributing to release of odours and the potential sources of their emission have been identified. Commercially available electrochemical...
-
Application of Ionic Liquids in Amperometric Gas Sensors
PublikacjaThis article presents an analysis of available literature data on metrological parameters of the amperometric gas sensors containing ionic liquids as an electrolyte. Four mechanism types of signal generation in amperometric sensors with ionic liquid are described. Moreover, this article describes the influence of selected physico-chemical properties of the ionic liquids on the metrological parameters of these sensors. Some metrological...
-
Application of ionic liquids in electronic nose instruments
PublikacjaAmong many applications in different fields of science and technology the ionic liquids (ILs) are also utilised in chemical sensors yielding improvement of their operation parameters (Buzzeo, 2004; Wei and Ivaska, 2008; Silvester, 2011; Gebicki et al., 2013). Some of these chemical sensors are the components of the devices, which resemble human sense of smell as far as their operation is concerned. These devices are named electronic...
-
APPLICATION OF ULTRAFAST GAS CHROMATOGRAPHY TO RECOGNIZE ODOR NUISANCE
PublikacjaPotentialities of ultrafast gas chromatography applied to periodical monitoring of odor nuisance originating from a municipal landfill have been examined. The results of investigation on classification of the atmospheric air samples collected in a vicinity of the landfill during winter and summer season have been presented. The investigation was performed using ultrafast gas chromatography of Fast/Flash GC type HERACLES II by Alpha...
-
Bezpośrednia analiza próbek z wykorzystaniem techniki spektrometrii mas. Cz. I. Rozwiązania metodyczne w zakresie spektrometrii mas umożliwiające bezpośrednią analizę próbek
PublikacjaTechnika spektrometrii mas stanowi jedno z najważniejszych narzędzi analitycznych, wykorzystywanych do identyfikacji, określania struktury chemicznej oraz oznaczania stężeń wielu związków chemicznych. Aby zidentyfikować obecne w próbkach rzeczywistych anality, konieczne jest jednak z reguły ich wstępne rozdzielenie, toteż spektrometry mas pełnią najczęściej rolę detektora np. w przypadku technik łączonych, gdy na etapie rozdzielania...
-
Bezpośrednia analiza próbek z wykorzystaniem techniki spektrometrii mas. Cz. II. Technika PTR – MS – ciekawe rozwiązanie metodyczne w zakresie spektrometrii mas
PublikacjaTechnika spektrometrii mas stanowi niezwykle istotne narzędzie badawcze, umożliwiające uzyskanie wielu cennych informacji, dotyczących składu chemicznego wielu próbek rzeczywistych pochodzenia biologicznego, farmaceutycznego i spożywczego. Spektrometr mas zazwyczaj pełni role detektora w przypadku stosowania połączenia z urządzeniami chromatograficznymi (GC, LC). Dzięki zastosowaniu pewnych modyfikacji aparaturowych i metodycznych,...
-
Chapter 11 – Application of Chemical Sensors and Sensor Matrixes to Air Quality Evaluation
PublikacjaIndoor and outdoor air quality is one of the key factors influencing human health. However, air quality evaluation is not easy task. Air is a complex system, which is subjected to changes even within short period of time. Progress in analytical methods and analytical tools provides increasingly more reliable information on the condition and quality of indoor and outdoor air. This progress, however, generates an increase in the...
-
Comparison of Evaluation of Air Odour Quality in Vicinity of Petroleum Plant Using a Prototype of Electronic Nose Instrument and Fast GC Technique
PublikacjaThe paper presents the results of investigation on classification of the ambient air samples collected in a vicinity of the LOTOS Group S.A. petroleum plant with respect to odour. The investigations were carried out with an electronic nose prototype and a commercial electronic nose of Fast GC-type – HERACLES II. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and a photoionization sensor of PID-type....
-
Comparison of the measurement techniques employed for evaluation of ambient air odour quality
PublikacjaThe paper presents the results of investigation on ambient air odour quality in a vicinity of the industrial sewage treatment plant being a part of the crude oil processing plant. The investigation was performed during spring-winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. The field...
-
Comparison of the Measurement Techniques Employed for Evaluation of Ambient Air Odour Quality Influenced by Operation of Industrial Sewage Treatment Plant
PublikacjaThe paper presents the results of investigation on ambient air quality evaluation with respect to concentration of odorants in a vicinity of a sewage treatment plant of the LOTOS Group S.A. petroleum plant. The investigation was performed during winter season using a prototype of electronic nose and the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type...
-
Comprehensive two dimensional gas chromatography coupled with mass spectrometry as tool for characterization of the main pollutants present in atmospheric air in Gdansk
PublikacjaNowadays, the technique that is commonly used to identify and quantify the chemical compounds in gas sample is gas chromatography. The separation resolution in gas chromatography can be improved by applying the modulation technique. In this paper present is the most important information regarding the pollutants present in atmospheric air. The areas in which the tests were carried out are one of the largest industrial zones in...
-
Devices for the production of reference gas mixtures
PublikacjaFor many years there has been growing demand for gaseous reference materials, which is connected with development in many fields of science and technology. As a result, new methodological and instrumental solutions appear that can be used for this purpose. Appropriate quality assurance/quality control (QA/QC) must be used to make sure that measurement data are a reliable source of information. Reference materials are a significant...
-
Dlaczego Politechnika Gdańska nie uzyskuje oceny wyróżniającej w akredytacji PKA?
PublikacjaPublikacja stanowi analizę uwag w ocenie instytucjonalnej pięciu wydziałów PG, sformułowanych przez Zespoły Oceniające PKA w raportach z wizytacji na Politechnice Gdańskiej w latach 2011–2015. Sformułowano zalecenia dla PG, których wdrożenie mogłoby wpłynąć na poprawę jakości kształcenia na wydziałach, a długofalowo przyczynić się do uzyskanie oceny wyróżniającej w akredytacji PKA.
-
Evaluation of Ambient Air Odour Quality in Vicinity of Municipal Landfill Using Electronic Nose Technique
PublikacjaThe paper presents the results of investigation on ambient air quality evaluation with respect to concentration of odorants in a vicinity of municipal landfill. The investigation was carried out with a prototype of electronic nose and a team of panelists utilizing the Nasal Ranger field olfactometers. The prototype was equipped with a set of six semiconductor sensors by FIGARO Co. and one PID-type sensor. Performed measurements...
Rok 2013
-
Application of the Electronic Nose Technique to Differentiation between Model Mixtures with COPD Markers
PublikacjaABSTRACT The paper presents the potential of an electronic nose technique in the field of fast diagnostics of patients suspected of Chronic Obstructive Pulmonary Disease (COPD). The investigations were performed using a simple electronic nose prototype equipped with a set of six semiconductor sensors manufactured by FIGARO Co. They were aimed at verification of a possibility of differentiation between model reference mixtures with...
-
Ekspertyza
PublikacjaEkspertyza dotycząca podtrzymania odwołania złożonego przez firmę MARCIN JANIK ENVI-SYSTEM, Osiedle Sienkiewicza 6 lok.1, 32-080 Zabierzów w Krajowej Izbie Odwoławczej przy Prezesie Urzędu Zamówień Publicznych, ul. Postępu 17a 02-676 Warszawa, wobec treści ogłoszenia o zamówieniu opublikowanym dnia 28 czerwca 2013r. w Dzienniku Urzędowym Unii Europejskiej pod numerem 2013/S 124-212469 oraz wobec postanowień specyfikacji istotnych...
-
Ekspertyza(1)
PublikacjaEkspertyza dotycząca podtrzymania odwołania złożonego przez firmę EAS ENVIMET POLSKA Sp. z o.o. z siedzibą w Wieliczce, ul. Park Kingi 1 32-020 Wieliczka w Krajowej Izbie Odwoławczej przy Prezesie Urzędu Zamówień Publicznych, ul. Postępu 17a 02-676 Warszawa, wobec treści ogłoszenia o zamówieniu opublikowanym dnia 20 lipca 2013r. w Dzienniku Urzędowym Unii Europejskiej pod numerem 2013/S 140-243351 oraz wobec postanowień specyfikacji...
-
Ekspertyza(2)
PublikacjaEkspertyza dotycząca odrzucenia odwołania złożonego przez firmę MLU Sp. z o.o. z siedzibą w Katowicach, ul. Połomińska 16 40-585 Katowice w Krajowej Izbie Odwoławczej przy Prezesie Urzędu Zamówień Publicznych, ul. Postępu 17a 02-676 Warszawa, wobec treści ogłoszenia o zamówieniu opublikowanym dnia 8 maja 2013r. w Dzienniku Urzędowym Unii Europejskiej pod numerem 151218-2013, dotyczącym postępowania o udzielenie zamówienia publicznego...
Rok 2004
-
Badania właściwości nowego amperometrycznego czujnika ditlenku siarki.
PublikacjaZaprojektowany i wykonany został nowy, amperometryczny czujnik ditlenku siarki, wyposażony w elektrodę roboczą ze złota napylonego bezpośrednio na powierzchnię membrany oddzielającej komórkę elektrokatalityczną czujnika od otoczenia. Sygnał czujnika, związany z reakcją elektrodową utleniania ditlenku siarki, jest proporcjonalny do stężenia SO2. W tej pracy przedstawiono rezultaty badań czujnika z membranami z mikroporowatego Teflonu...
Rok 2010
-
Badanie i porównanie zdolności wybranych leków i związków przeciwnowotworowych do międzyłańcuchowego sieciowania DNA mitochondrialnego i jądrowego w komórkach nowotworowych
PublikacjaCelem pracy było zbadanie zdolności przeciwnowotworowych związków do indukowania międzyłańcuchowych wiązań sieciujących DNA mitochondrialne w ludzkich komórkach nowotworowych oraz porównanie ze zdolnością do sieciowania DNA jądrowego. Pochodna 4-metylo-1-nitroakrydyny C-1748, Ledakrin i mitomycyna C wykazują zdolność do sieciowania mtDNA i jDNA w komórkach raka okrężnicy HCT-8 w sposób zależny od dawki; C-1748 w komórkach raka...
-
Electrochemical sensor for measurement of volatile organic compounds = Elektrochemiczny czujnik do oznaczania lotnych związków organicznych
PublikacjaPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania benzaldehydu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako technikę detekcyjną woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym były ciecze jonowe: chlorek 1-heksylo,3- metyloimidazolinowy i bis(trifluorometylosulfonylo)imidek...
-
Electrochemical sensor for measurement of volatile organic compounds employing square wave perturbation voltage
PublikacjaThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde in air. Sensitivity and limit of quantification of the sensor were determined for different internal electrolyte using the square wave voltammetry (SWV) as a detection technique. The working and counter electrodes were made of platinum. Ionic liquids 1-hexyl, 3-methylimidazolium chloride,1-hexyl, 3-methylimidazolium bis (trifluoromethanesulfonyl)...
-
Electrochemical sensor for measurement of volatile organic compounds in air
PublikacjaPrzedstawiono rezultaty badań prototypowego czujnika do oznaczania mrówczanu etylu i formaldehydu w powietrzu. Określono czułość wskazań czujnika i jego granice oznaczalności wykorzystując jako techniki detekcyjne pulsową woltamperometrię różnicową (DPV) oraz woltamperometrię fali prostokątnej (SWV). Elektrodę roboczą i przeciwelektrodę stanowiły elektrody z Pt. Elektrolitem wewnętrznym była ciecz jonowa (chlorek 1-heksylo,3-metyloimidazolinowy)....
Rok 2020
-
Bioelectronic tongue: Current status and perspectives
PublikacjaIn the course of evolution, nature has endowed humans with systems for the recognition of a wide range of tastes with a sensitivity and selectivity which are indispensable for the evaluation of edibility and flavour attributes. Inspiration by a biological sense of taste has become a basis for the design of instruments, operation principles and parameters enabling to mimic the unique properties of their biological precursors. In...
-
Deodorization of model biogas by means of novel non-ionic deep eutectic solvent
PublikacjaThe paper presents new non-ionic deep eutectic solvent (DES) composed of natural and non-toxic components i.e. guaiacol, camphor and levulinic acid in 1:1:3 molar ratio as a promising absorbent for removal of selected volatile organic compounds (VOCs) including dichloromethane, toluene, hexamethyldisiloxane and propionaldehyde from model biogas. The affi nity of DES for VOCs was determined as vapour-liquid coeffi cients and the...
-
Determination of long-chain aldehydes using a novel quartz crystal microbalance sensor based on a biomimetic peptide
PublikacjaThere is an increasingly popular trend aimed at improvement of fundamental metrological parameters of sensors via implementation of materials mimicking biological olfactory systems. This study presents investigation on usefulness of the peptide mimicking HarmOBP7 region as a receptor element of the piezoelectric sensor for selective analysis of long-chain aldehydes. Identification of odorant binding proteins creates new possibilities...
-
Evaluation of Immobilization of Selected Peat-Isolated Yeast Strains of the Species Candida albicans and Candida subhashii on the Surface of Artificial Support Materials Used for Biotrickling Filtration
PublikacjaThe paper describes the process of n-butanol abatement by unicellular fungi, able to deplete n-butanol content in gas, by using n-butanol as source of carbon. Isolated and identified fungi species Candida albicans and Candida subhashii were subjected to a viability process via assimilation of carbon from hydrophilic and hydrophobic compounds. The isolates, which exhibited the ability to assimilate carbon, were immobilized on four...
-
Extractive detoxification of feedstocks for the production of biofuels using new hydrophobic deep eutectic solvents – Experimental and theoretical studies
PublikacjaThe paper presents a synthesis of novel hydrophobic deep eutectic solvents (DESs) composed of natural components, which were used for removal of furfural (FF) and 5-hydroxymethylfurfural (HMF) from lignocellulosic hydrolysates. The main physicochemical properties of DESs were determined, followed by explanation of the DES formation mechanism, using 1H NMR, 13C NMR and FT-IR analysis and density functional theory (DFT). The most...
Rok 2021
-
Bio-inspired approaches for explosives detection
PublikacjaDue to unique abilities of the animals regarding analysis of complex gas substances, they still remain a gold standard in analysis of explosives. Unusual capabilities of biological chemosensory systems, including both vertebrates and invertebrates, stimulate elaboration of the devices mimicking their activity and operation parameters as precisely as possible. The electronic analogues are a subject of investigation in many research...
-
Deep eutectic solvents – based green absorbents for effective volatile organochlorine compounds removal from biogas
PublikacjaVolatile organochlorine compounds (VOXs) presented in biogas can cause many technological and environmental problems. During the combustion of biogas containing VOXs, the corrosion of installation, as well as the formation of toxic by-products (polyhalogenated dioxins and furans) and further emission to the atmosphere, may occur. Therefore, in this study, a new procedure based on physical absorption was developed. In order to meet...
-
Development of Gas Sensor Array for Methane Reforming Process Monitoring
PublikacjaThe article presents a new method of monitoring and assessing the course of the dry methane reforming process with the use of a gas sensor array. Nine commercially available TGS chemical gas sensors were used to construct the array (seven metal oxide sensors and two electrochemical ones). Principal Component Regression (PCR) was used as a calibration method. The developed PCR models were used to determine the quantitative parameters...
-
Emerging strategies for enhancing detection of explosives by artificial olfaction
PublikacjaExplosives detection systems need to be able to reliably detect a wide range of explosive materials and their vapours. The continued development and improvement of artificial olfaction techniques, including electronic nose (EN), remains important to overcome existing challenges and meet requirements posed by new improvements in the field of explosives. There is an increasingly popular trend aimed at improvement of fundamental metrological...
Rok 2023
-
Catalytic activity of Ni-MgAl2O4 modified with transition metal (Ti, Mo, W) carbides as potential catalysts for resource recovery via dry reforming of waste plastics
PublikacjaThe growing amounts of plastic waste and CO2 emissions are two environmental threats that require urgent attention. Pyrolysis combined with dry reforming (PCDR) is a technology that allows both CO2 utilization and resource recovery from waste plastic. New catalysts for PCDR are crucial for developing efficient and stable processes that can be widely implemented in the industry. In this study, Ni/MgAl2O4 catalysts modified using different...
-
Effect of Microplastics Pollution on Hydrogen Production from Biomass: A Comprehensive Review
PublikacjaHydrogen production from biomass and organic wastes is considered as a potential alternative energy source and is known as a clean and CO2-free fuel energy carrier. H2 is considered very promising among the other energy sources; therefore, the effective conversion of biomass and organic solid waste to this secondary energy source is urgently sought. As a result, it is of importance to assess the impact of the existence of microplastics...
-
Evaluation of Linkers’ Influence on Peptide-Based Piezoelectric Biosensors’ Sensitivity to Aldehydes in the Gas Phase
PublikacjaRecent findings qualified aldehydes as potential biomarkers for disease diagnosis. One of the possibilities is to use electrochemical biosensors in point-of-care (PoC), but these need further development to overcome some limitations. Currently, the primary goal is to enhance their metrological parameters in terms of sensitivity and selectivity. Previous findings indicate that peptide OBPP4 (KLLFDSLTDLKKKMSEC-NH2) is a promising...
-
Extractive detoxification of hydrolysates with simultaneous formation of deep eutectic solvents
PublikacjaThe hydrolysis of lignocellulosic biomass results in the production of so-called fermentation inhibitors, which reduce the efficiency of biohydrogen production. To increase the efficiency of hydrogen production, inhibitors should be removed from aqueous hydrolysate solutions before the fermentation process. This paper presents a new approach to the detoxification of hydrolysates with the simultaneous formation of in-situ deep eutectic...
Rok 2015
-
Determination of authenticity of brand perfume using electronic nose prototypes
PublikacjaThe paper presents practical application of an electronic nose technique for fast and efficient discrimination between authentic and fake perfume samples. Two self-built electronic nose prototypes equipped with a set of semiconductor sensors were employed for that purpose. Additionally 10 volunteers took part in sensory analysis. The following perfumes and their fake counterparts were analysed: Dior – Fahrenheit, Eisenberg – J’ose,...
-
Determination of benzo(a)pyrene content in PM10 using regression methods
PublikacjaThe paper presents an attempt of application of multidimensional linear regression to estimation of an empirical model describing the factors influencing on B(a)P content in suspended dust PM10 in Olsztyn and Elbląg city regions between 2010 and 2013. During this period annual average concentration of B(a)P in PM10 exceeded the admissible level 1.5-3 times. Conducted investigations confirm that the reasons of B(a)P concentration...
Rok 2009
-
Ekspertyza dotycząca bezzasadności zarzutów odnośnie parametrów metrologicznych analizatorów pyłu PM2,5 postawionych firmom EAS Envimet Polska Sp. z o.o. i EAS Envimet Analytical Systems GmbH przez spółkę MLU Sp. z o.o. z siedzibą w Katowicach w postępowaniu odwoławczym o sygn. akt: KIO/UZP 435/09
PublikacjaW ekspertyzie sporządzonej dla EAS Envimet Polska sp. z o.o. z siedzibą w Wieliczce wykazano bezzasadność zarzutów zgłoszonych przez Spółkę MLU w Katowicach w odniesieniu do urządzenia BAM1020 w postępowaniu odwoławczym toczącym się przed Prezesem Urzędu Zamówień Publicznych w związku z zaskarżeniem rozstrzygnięcia przetargu o zamówienie publiczne nr DM/5211-06-02/09/ABA na zakup automatycznego miernika pyłu zawieszonego PM2,5...