Search results for: VOLTAGE MEASUREMENT
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 2,9 V at 420 mA. Sample 103, run #3.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 2,9 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #3. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #3.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #3. Continuation of experiment at high voltage to accelerate the ageing process.The images were taken with thermographic...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,4 V at 420 mA. Sample 103, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,4 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #1. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #2.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #2. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...
-
Problems of varistor quality assessment during exploitation
PublicationVaristors are commonly used elements which protect power supply networks against high-voltage surges or lightning. Therefore, quality and endurance of these elements is important to avoid losses when an expensive laboratory equipment would not be protected from random overvoltages. Additionally, excessive leakage currents generate serious costs due to high energy consumption. The paper presents shortly properties of varistors that...
-
Output voltage, current and DC-link voltages under SVPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The comparison studies between proposed Space Vector Pulse-Width...
-
Output voltage, current and DC-link voltages under SPWM, experimental results
Open Research DataThe dataset contains the experimental results of the project: A universal algorithm of space vector pulse width modulation for three-level three and multi-phase NPC inverters with DC-link voltage balancing. The output line-to-line voltage, output current and DC-link voltages were included. The Carrier-Based Pulse-Width Modulation (CBPWM) technique was...
-
Badanie wybranych właściwości wyłączników różnicowoprądowych typu F
PublicationW instalacjach elektrycznych niskiego napięcia instaluje się coraz więcej przekształtników energoelektronicznych (systemy fotowoltaiczne, instalacje ładowania pojazdów elektrycznych, układy napędowe o regulowanej prędkości obrotowej silnika), a mają one wpływ na dobór typu wyzwalania wyłączników różnicowoprądowych (AC, A, F lub B). W obwodach, w których pojawia się prąd różnicowy zawierający składowe o częstotliwości innej niż...
-
Raman miniaturised system for field applications
PublicationRaman spectroscopy is a powerful and versatile research technique with a broad range of potential applications, which includes laboratory studies, on-line industrial process monitoring and field measurements. Scope of the field applications includes environment monitoring, detection of dangerous or prohibited materials and rapid identification of unknown samples. It stimulates development of dedicated Raman measurement equipment...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,4 V at 420 mA. Sample 103. Image period: 0,5 sec.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,4 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 0,5 sec (2 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,3 V at 420 mA. Sample 103, run #1.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,3 V and discharged to 10 mV by constant current 420 mA. Sample 103, experiment run #1. Voltage was increased to accelerate the ageing process.The images were taken with thermographic camera VigoCAM...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103. Image period: 0,5 sec.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 0,5 sec (2 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,5 V at 420 mA. Sample 103. Image period: 0,5 sec.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,5 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 0,5 sec (2 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103. Image period: 1 sec.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 1 sec (1 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,4 V at 420 mA. Sample 103. Image period: 1 sec.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,4 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 1 sec in order to examine the fast fluctuations of sample temperature during charging - discharging...
-
BEZCZUJNIKOWE STEROWANIE WOLNOOBROTOWYM SILNIKIEM PMSM Z KOMPENSACJĄ MOMENTU ZACZEPOWEGO
PublicationW pracy przedstawiono propozycję rozwiązania problemu bezczujnikowego sterowania wolnoobrotową maszyną synchroniczną z magnesami trwałymi PMSM. Przedstawiono silnik PMSM, który zastosowano w stanowisku badawczym. Omówiono problem występowania tętnień momentu napędowego wynikający głównie ze znacznego momentu zaczepowego. Pokazano rozwiązanie kompensujące tętnienia momentu napędowego w silniku PMSM. Przygotowano procedurę startową...
-
The standard radiated immunity test of an astable multivibrator at a normative field strength
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 80 MHz to 1 GHz are performed...
-
Audible noise in ship’s electrical drive systems with frequency converters
Open Research DataThe presented dataset is part of research focusing on the impact of the ship's electrical drive systems with frequency converters on vibrations and the level of audible noise on ships.
-
In Vitro Biological Characterization of Silver-Doped Anodic Oxide Coating on Titanium
PublicationDespite the high biocompatibility and clinical effectiveness of Ti-based implants, surface functionalization (with complex osteointegrative/antibacterial strategies) is still required. To enhance the dental implant surface and to provide additional osteoinductive and antibacterial properties, plasma electrolytic oxidation of a pure Ti was performed using a nitrilotriacetic acid (NTA)-based Ag nanoparticles (AgNP)-loaded calcium–phosphate...
-
The electrical properties mesurements of SOFC with Ce0.9Cu0.1O2-s functional layer
Open Research DataThe dataset includes the electrical properties mesurements of SOFC with Ce0.9Cu0.1O2-s layer. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding at 750oC. The layers were sintered at 1100oC.
-
The electrical properties mesurements of SOFC with Ce0.9Co0.1O2-s functional layer
Open Research DataThe dataset includes the electrical properties mesurements of SOFC with Ce0.9Co0.1O2-s layer. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding at 750oC. The layers were sintered at 1100oC.
-
The electrical properties mesurements of SOFC with Ce0.8Co0.1Cu0.1O2-s functional layer
Open Research DataThe dataset includes the electrical properties mesurements of SOFC with Ce0.8Co0.1Cu0.1O2-s layer. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding at 750oC. The layers were sintered at 1100oC.
-
The electrical properties mesurements of SOFC with Ce0.8Co0.15Cu0.05O2-s functional layer
Open Research DataThe dataset includes the electrical properties mesurements of SOFC with Ce0.8Co0.15Cu0.05O2-s layer. Samples were produced using aqueous soft chemistry methods (microemulsion method) and applied in form of a layer onto the anode of the commercial SOFC. The SOFC was working under biogas feeding at 750oC. The layers were sintered at 1100oC.
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103. Image period: 0,5 sec.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 0,5 sec (2 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103. Image period: 1 sec.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 1 sec (1 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Diagnostyka off-line stanu izolacji uzwojeń silników 6 kV z wykorzystaniem obrazowania akustycznego wyładowań niezupełnych
PublicationW zakładach przemysłowych, w których kluczowe procesy produkcyjne są realizowane z wykorzystaniem silników średniego napięcia, dla których diagnostyka izolacji uzwojeń ma istotne znaczenie. W tym celu wykonuje się ocenę porównawczą wyników pomiarów wyładowań niezupełnych (WNZ) wykonywanych dla jednostek tego samego typu, a jej skuteczność w znacznej mierze wynika z wieloletniego doświadczenia diagnosty. Dla opracowania wyników...
-
Intelligent turbogenerator controller based on artifical neural network
PublicationThe paper presents a desing of an intelligent controller based on neural network (ICNN). The ICNN ensures at the same time two fundamental functions : the maintaining of generator voltage at the desired value and the damping of the electromechanical oscillations. Its performance is evaluted on a single machine infinite bus power system through computer simulations. The dynamic and transient operation of the proposed controller...
-
Modeling of Electrified Transportation Systems Featuring Multiple Vehicles and Complex Power Supply Layout
PublicationThe paper proposes a novel approach to modeling electrified transportation systems. The proposed solution reflects the mechanical dynamics of vehicles as well as the distribution and losses of electric supply. Moreover, energy conversion losses between the mechanical and electrical subsystems and their bilateral influences are included. Such a complete model makes it possible to replicate, e.g., the impact of voltage drops on vehicle...
-
Performance of acicular grindable thermocouples for temperature measurements at sliding contacts
PublicationThe present study investigates the performance of acicular grindable thermocouples based on a constantan wire / steel hollow cylinder construction. The experiments showed that the measuring junction electrical resistance, temperature–voltage characteristic, measuring junction rise time and signal noise standard deviation of the acicular thermocouples are comparable to those of conventional J-type thermocouples with bare wire diameter...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #2. Image period: 1 sec.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 1 sec (1 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #3. Image period: 0,5 sec.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 0,5 sec (2 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #2. Image period: 0,5 sec.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 0,5 sec (2 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Thermographic imaging of electrochemical double layer capacitors during cycling charging - discharging 0 - 3,6 V at 420 mA. Sample 103, run #3. Image period: 1 sec.
Open Research DataDataset contains thermal images of prototype electrochemical double layer capacitor taken during cyclic charging - discharging. The sample was charged to 3,6 V and discharged to 10 mV by constant current 420 mA. Sample 103. Pictures were taken with period of 1 sec (1 Hz) in order to examine the fast fluctuations of sample temperature during charging...
-
Characterization of Defects Inside the Cable Dielectric With Partial Discharge Modeling
PublicationThe continuous monitoring of power system devices is an important step toward keeping such capital assets safe. Partial discharge (PD)-based measurement tools provide a reliable and accurate condition assessment of power system insulations. It is very common that voids or cavities exist in every solid dielectric insulation medium. In this article, different voids are modeled and analyzed using an advanced finite element (FE)-based...
-
Metoda diagnostyki łożysk na podstawie analizy przebiegów prądu i napięcia zasilającego silnik indukcyjny.
PublicationW niniejszej monografii przedstawiono oryginalne podejście i realizację diagnostyki łożysk silników indukcyjnych przy użyciu metody opartej na pomiarach i analizie iloczynu wartości chwilowych prądu i napięcia zasilającego maszyny. Uzyskane wyniki badań eksperymentalnych na obiektach rzeczywistych okazały się zbieżne z wynikami badań symulacyjnych i potwierdziły, że powstanie uszkodzeń łożysk w silniku skutkuje pojawieniem się...
-
Diagnostyka analogowych filtrów wielosekcyjnych oparta na magistrali testującej IEEE1149.1
PublicationPrzedstawiono nową koncepcję testera JTAG BIST do samo-testowania torów analogowych opartych na wielosekcyjnych filtrach wyższego rzędu w mieszanych sygnałowo mikrosystemach elektronicznych sterowanych mikrokontrolerami i wyposażonych w magistralę testującą IEEE1149.1 (JTAG). Bazuje ona na metodzie diagnostycznej opartej na przekształce-niu transformującym próbki odpowiedzi czasowych kolejnych sekcji filtra pobudzonego impulsem...
-
Design advantages and analysis of a novel five-phase doubly-fed induction generator
PublicationPurpose – The purpose of this paper is to provide an analysis of the performance of a new five-phase doubly fed induction generator (DFIG). Design/methodology/approach – This paper presents the results of a research work related to fivephase DFIG framing, including the development of an analytical model, FEM analysis as well as the results of laboratory tests of the prototype. The proposed behavioral level analytical model is based...
-
The radiated immunity test of an astable multivibrator in the frequency range from 100 MHz to 300 MHz
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 100 MHz to 300 MHz were...
-
The short-term flicker severity level measured in the industrial power system supplying the rolling mill motors
Open Research DataThe dataset presents a short-term flicker severity level measured on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data were obtained during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage fluctuations. In the virtual application of...
-
Linear impedance as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass measured with impedance spectroscopy method
Open Research DataThe linear electrcial properties as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass was measured by impedance spectroscopy method.
-
The radiated immunity test of an astable multivibrator at over-normative field strengths
Open Research DataThe dataset presents a result of measurements that are a part of electromagnetic field immunity tests. The radiated, radio frequency, immunity tests were carried out for a typical astable electronic multivibrator. Tests of immunity of electronic systems to radiated radio frequency (RF) disturbances in the frequency range from 80 MHz to 1 GHz were performed...
-
Amplitude-distance spectroscopy in semi-contact mode
Open Research DataSince it was invented by Binnig et al. in 1986, atomic force microscopy (AFM) plays a key role in science and technology at the nanoscale. AFM is a microscopic technique that visualizes the surface topography using the attractive and repulsive forces of interaction between several atoms (in theory) of a blade attached to the end of the probe lever and...
-
Time window based features extraction from temperature modulated gas sensors for prediction of ammonia concentration
PublicationElectronic gas recognition systems, in literature commonly referred as electronic noses, enable the recognition of a type and a concentration of various volatile compounds. Typical electronic gas-analyzing device consists of four main elements, namely, gas delivery subsystem, an array of gas sensors, data acquisition and power supply circuits and data analysis software. The commercially available metal-oxide TGS sensors are widely...
-
Nonlinear impedance as a function of A.C. voltage of Bi2VO5.5 ceramic of thickness 2.88 mm was measured at 693 K with impedance spectroscopy method
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 2.88 mm was measured by impedance spectroscopy method.
-
Electro-optical transducer based on indium-tin-oxide-coated optical fiber for analysis of ionized media
PublicationThe paper introduces a concept of an optical fiber based electro-optical transducer for monitoring of ionized media, such as low-temperature plasma. It utilizes optical fiber with a section of a core coated with tailored indium tin oxide (ITO) thin film and thus combines the optical phenomena of lossy-mode resonance (LMR) with the electrostatic probe. ITO is an optically transparent and electrically conductive material and if its...
-
Nonlinear impedance as a function of A.C. voltage for fully crystallized 35Bi2VO5.5-65SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties as a function of A.C. voltage for fully crystallized 35Bi2VO5.5-65SrB4O7 glass was measured by impedance spectroscopy method.
-
Nonlinear impedance as a function of temperature and frequency for Bi2VO5.5 ceramic of thickness 2.52 mm was measured at different A.C. voltage with impedance spectroscopy method
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 2.52 mm was measured by impedance spectroscopy method.
-
Nonlinear impedance as a function of A.C. voltage of Bi2VO5.5 ceramic of thickness 1.63 mm was measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 1.63 mm was measured by impedance spectroscopy method.
-
Nonlinear impedance as a function of A.C. voltage of Bi2VO5.5 ceramic of thickness 4.03 mm was measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 4.03 mm was measured by impedance spectroscopy method.
-
Nonlinear impedance as a function of A.C. voltage of Bi2VO5.5 ceramic of thickness 2.91 mm was measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 2.91 mm was measured by impedance spectroscopy method.
-
Nonlinear impedance as a function of A.C. voltage for fully crystallized 45Bi2VO5.5-55SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties as a function of A.C. voltage for fully crystallized 45Bi2VO5.5-55SrB4O7 glass was measured by impedance spectroscopy method.
-
A cumulative probability function of instantaneous flicker sensation values measured in the industrial power system supplying the rolling mill motors
Open Research DataThe dataset presents a cumulative probability function CPF of the instantaneous flicker sensation level measured on the bus bars of the main switchgear of the industrial power network for the supply of rolling mills. The data were obtained during an experiment whose purpose was to determine a level of short-term and long-term flicker caused by voltage...
-
The low-frequency magnetic field emissions on-board of the vessel
Open Research DataThe data represents measurement results performed on board of the vessel. The acquired time-waveforms, corresponding to the instantaneous values of the magnetic field (MF) induction were acquired near the cable supplying the bow thruster motor. Data recording of the magnetic field density (MFD) emissions was carried out with a/d converters of the data...
-
Nonlinear impedance as a function of A.C. voltage for annealed and next fully crystallized 50Bi2VO5.5-50SrB4O7 glass measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties as a function of A.C. voltage for annealed and next fully crystallized 50Bi2VO5.5-50SrB4O7 glass was measured by impedance spectroscopy method.
-
Improving voltage levels in low-voltage networks with distributed generation – case study
PublicationThe use of distributed generation in low-voltage networks may cause the voltage variation in them, within the wide range. In unfavourable circumstances, the voltage may reach unacceptable values. The paper presents the effect of distributed generation on voltage levels in a selected low-voltage rural distribution network in Poland. An analysis of possible methods for improving voltage levels in this network is conducted. The most...
-
Voltage Transients Transfer over Medium Voltage Instrument Transformers
PublicationThis paper presents voltage harmonic transfer accuracy problems through voltage transformers which are used in power quality monitoring systems in medium and high voltage grids. A simplified lumped parameters circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number voltage transformers typically used in medium voltage grid has been tested in the conducted disturbances...
-
Voltage Conditions in Low Voltage Grid with Connected Mictogeneration
PublicationThe introduction of distributed generation into a low voltage grid may cause voltage problems in it. The paper discusses the effect of microgeneration on voltage levels in a low voltage grid. A real low voltage grid of considerable length was selected for the analysis. The grid primarily supplies residential buildings in a rural area. Results of tests that consider potential measures which could be applied in this grid to improve...
-
Voltage Harmonics Transfer through Medium Voltage Instrument Transformers
PublicationVoltage transformers are widely used in power quality monitoring systems in medium and high voltage grids. This paper presents accuracy problems related to voltage harmonics transfer through instrument transformers. A simplified lumped-parameters wideband circuit model of the voltage transformer is proposed and verified by simulation and experimental investigations. A number of voltage transformers have been tested in the frequency...
-
Static Series and Shunt-series PE Voltage-quality Controllers
PublicationAs presented in the Chap. 7 static shunt power electronics (PE) voltage-quality controllers protect the utility electrical system from the unfavorable impact of customer loads. Shunt controllers, as shown in Chap. 6, are recommended mainly for mitigation of the causes of disturbances, and not their effects in distanced nodes of a power-electronics system. In the case when reduction of disturbances effects is required, which leads...
-
Linear impedance as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K measured with impedance spectroscopy method at 273 K
Open Research DataThe linear electrcial properties as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass heat treated at 693 K was measured by impedance spectroscopy method.
-
Starter for Voltage Boost Converter to Harvest Thermoelectric Energy for Body-Worn Sensors
PublicationThis paper examines the suitability of selected configurations of ultra-low voltage (ULV) oscilla-tors as starters for a voltage boost converter to harvest energy from a thermoelectric generator (TEG). Important properties of particularly promising configurations, suitable for on-chip imple-mentation are compared. On this basis, an improved oscillator with a low startup voltage and a high output voltage swing is proposed. The applicability...
-
Miernictwo elektryczne na politechnice w Gdańsku w latach 1904–1945
PublicationPolitechnika Gdańska została utworzona w 1904 roku. Działalność uczelni nierozerwalnie związana była z losami Gdańska, dlatego w jej historii do 1945 roku można wyróżnić trzy okresy: pruski, Wolnego Miasta Gdańska oraz czasy drugiej wojny światowej. Od początku, jednym z ważniejszych kierunków nauczania była elektrotechnika. Postęp w elektrotechnice nie był możliwy bez rozwoju miernictwa elektrycznego, dlatego przez cały czas działania...
-
Optimized Space Vector Modulation strategy for five phase voltage source inverter with third harmonic injection
PublicationThis paper presents a simple and an effective SVM algorithm for five-phase Voltage-Source Inverters with the possibility to control independently the voltage vectors for fundamental and auxiliary orthogonal subspaces. The essential benefit is that output voltage is generated using only four active voltage vectors with limited numbers of switching. In the proposed solution, four active vectors are arbitrary chosen, independent of...
-
A 0.5-V bulk-driven voltage follower / DC level shifter and its application in class AB output stage
PublicationA simple realization of a 0.5-V bulk-driven voltage follower/DC level shifter, designed in a 0.18um CMOS technology is presented in the paper. The circuit is characterized by large input and output voltage swings, and a DC voltage gain close to unity. The DC voltage shift between input and output terminals can be regulated in a certain interval around zero, by means of biasing current sinks. An application of the proposed voltage...
-
Distribution Transformer with Multi-Zone Voltage Regulation for Smart Grid System Application
PublicationThe article presents four concepts of the multi-zone voltage regulation (MZVR) system. It is a combination of a distribution transformer with an on-load tap-changer, for step voltage regulation, and a power electronic converter, dimensioned for a fraction of MZVR power, realizing continuous voltage regulation, supplemented by a special switch, the so-called bypass. This allows voltage regulation at high resolution, wide range and...
-
Multilevel inverter neutral-point voltage sensor diagnostic based on the Extended Kalman Filter
PublicationA new algorithm for neutral point voltage imbalance estimation in DC link of the three-level (3L) neutral point clamped (NPC) voltage source inverter (VSI) is proposed. Application of the proposed algorithm does not require any additional sensors. The unbalanced voltage calculation is based on the information derived from the inverter output measured currents and from the knowledge of the load model parameters. In order to estimate...
-
Synchronized six-step voltage generation in high-speed PMSM drive
PublicationSynchronized voltage generation has already been considered in the context of pulse width modulation (PWM). References prove that synchronized PWM substantially decreases subharmonics in inverter output voltage when operating with low switching-to-fundamental frequency ratio. This paper identifies problems of unsynchronized voltage generation in electric drives under six-step inverter operation. Guidelines for the synchronization...
-
Estimation of the uncertainty of the AC/AC transducer output voltage
PublicationThe paper presents a methodology for estimating uncertainty of voltage transducers processing function, on the example of CYVS411D07 voltage transducers. The analysis was conducted using the method based on the GUM Guide propagation of uncertainty law and the determination of the coverage factor based on the effective number of degrees of freedom (t-Student distribution). The paper also presents example evaluation results of measured...
-
Nonlinear impedance as a function of A.C. voltage for glass 40Bi2VO5.5-60SrB4O7 annealed at 593 K and next fully crystallized measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties as a function of A.C. voltage for annealed at 593 K and next fully crystallized 40Bi2VO5.5-60SrB4O7 glass was measured by impedance spectroscopy method.
-
Quasi-resonant DC-link voltage inverter with enhanced zero-voltage switching control
PublicationA new topology modification of the parallel quasi-resonant circuit for a dc-link voltage inverter enables regulation of the zero voltage dc-link subperiods and the dc-link voltage gradient settings. The proposed circuit is based on four MOSFET switches with free-wheeling diodes for controlled quasi-resonant recharging between L-C tank in order to assure inverter zero voltage switching (ZVS) conditions. Design optimization of the...
-
Dynamic variables limitation for backstepping control of induction machine and voltage source converter
PublicationDynamic variables limitation for backstepping control of induction machine and voltage source converter The paper presents the method of control of an induction squirrel-cage machine supplied by a voltage source converter. The presented idea is based on an innovative method of the voltage source converter control, consisting in direct joining of the motor control system with the voltage source rectifier control system. The combined...
-
Measure small currents without adding resistive insertion loss
PublicationFloating current to voltage converter can be inserted in-line with no voltage drop and no need for a ground reference.
-
Impact of R/X ratio of distribution network on selection and control of energy storage units
PublicationThe interest in energy storage is still increasing. Energy storage units are installed in high voltage networks, medium voltage networks and low voltage distribution networks as well. These units are often used to improve power quality. One of the criteria for improving power quality is reducing voltage deviations. Depending on the type of network and specifying its R/X ratio, this criterion can be fulfilled by control of active...
-
Research of Emergency Modes of Wind Power Plants Using Computer Simulation
PublicationThe aim of this study is to investigate changes in the wind power plant energy production parameters under the conditions of sudden wind changes and voltage drop. To achieve these goals, a simulation of operation of wind power plants was performed. Twelve wind turbines with variable rotational speed equipped with a Fuhrländer FL 2500/104 asynchronous double-fed induction generator (DFIG) were used, each with an installed capacity...
-
VSC converters control for offshore wind farms HVDC grid connection
PublicationThe paper proposes a voltage sourced converter (VSC) new control method. A well-known in the electric power systems correlation between voltage angle and active power and correlation between voltage and reactive power is used instead of feedforward control. This allows for a fast and almost independent control of active and reactive power flow.
-
Nonlinear impedance as a function of A.C. voltage for glass 40Bi2VO5.5-60SrB4O7 annealed at 473 K for 3h and next fully crystallized measured with impedance spectroscopy method at high temperature region
Open Research DataThe nonlinear electrcial properties as a function of A.C. voltage for annealed at 473 K for 3h and next fully crystallized 40Bi2VO5.5-60SrB4O7 glass was measured by impedance spectroscopy method.
-
Linear impedance as a function of A.C. voltage for 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat-treated at 813 K measured with impedance spectroscopy method at high temperature region
Open Research DataThe linear electrcial properties as a function of A.C. voltage of 50(2Bi2O3-V2O5)-50SrB4O7 glass-ceramic heat treated at 813 K was measured by impedance spectroscopy method.
-
Niekorzystny wpływ przekształtnikowego zasilania PWM na silniki asynchroniczne trakcyjne
PublicationThe electric traction drives with an AC motor fed by a frequency converter are used more and more often nowadays. The most significant side effects, of a converter's output voltage forming PWM method for AC motor windings, are steep voltage changes, which can initiate several destructive phenomena. The paper presents the adverse influence of a converter common mode voltage on the motor windings' increased voltage exposure and the...
-
Destructive impact of PWM inverters on traction AC motors
PublicationThe electric traction drives with an AC motor fed by a frequency converter are used more and more often nowadays. The most significant side effects, of a converter's output voltage forming PWM method for AC motor windings, are steep voltage changes, which can initiate several destructive phenomena. The paper presents the adverse influence of a converter common mode voltage on the motor windings's increased voltage exposure and...
-
Destructive Consequences of PWM Inverter Feeding for Traction AC Motors
PublicationThe electric traction drives with an AC motor fed by a frequency converter are used more and more often nowadays. The most significant side effects, of a converter's output voltage forming PWM method for AC motor windings, are steep voltage changes, which can initiate several destructive phenomena. The paper presents the adverse influence of a converter common mode voltage on the motor windings' increased voltage exposure and the...
-
Voltage profiles improvement in a power network with PV energy sources – results of a voltage regulator implementation
PublicationThe constant increase in the number of photovoltaic (PV) energy sources in distribution networks is the cause of serious voltage problems. The networks built at least a dozen years ago are not provided for the installation of a large number of micro-sources. It happens that the previously properly functioning power networks are not able to provide to consumers power with the required parameters, after installing many PV sources....
-
Dead-Time Effect Compensation Based on Additional Phase Current Measurements
PublicationThis paper proposes a new method of dead-time effect compensation. The proposed solution is based on additional phase current measurements realized by analog-to-digital converters. These measurements are carried out at the time instants specified by a pulsewidth-modulation (PWM) strategy. This makes it possible to estimate inverter currents at the commutation instants and, finally, to estimate the voltage error caused by dead time. This...
-
Voltage variations and their reduction in a rural low-voltage network with PV sources of energy
PublicationRenewable sources of energy (RES), especially photovoltaic (PV) micro-sources, are very popular in many countries. This way of clean power production is applied on a wide scale in Poland as well. The Polish legal regulations and tariffs specify that every prosumer in a low-voltage network may feed this network with a power not higher than the maximum declared consumed power. In power networks with RES, the voltage level changes...
-
Low-Voltage LDO Regulator Based on Native MOS Transistor with Improved PSR and Fast Response
PublicationIn this paper, a low-voltage low-dropout analog regulator (ALDO) based on a native n-channel MOS transistor is proposed. Application of the native transistor with the threshold voltage close to zero allows elimination of the charge pump in low-voltage regulators using the pass element in a common drain configuration. Such a native pass transistor configuration allows simplification of regulator design and improved performance,...
-
Resonant Conditions in a Node with an SVC Compensator
PublicationThe primary purpose of installing static shunt compensators in power grids is to improve the voltage conditions. Additional reactive power sources increase the system’s voltage stability and enable faster system recovery after a voltage failure. This paper presents the impact of an SVC device’s structure and settings on impedance change in the supply system, and hence on the frequencies at which resonance phenomena can develop.
-
THREE-LEVEL F-TYPE INVERTER
PublicationGiven the recent available IGBT switch modules up to 6.5 kV, 1200 A rating, the prospect of the diode-free variant topology of the three-level neutral-point-clamped (3-level, T-type) inverter in certain medium voltage applications is bright; due to its small part count and low conduction losses compared to the diode-clamped NPC inverter. However, within this voltage range, the input dc voltage rating of 50% of the switches per...
-
Estimation of the Maximum Permissible PV Power to be Connected to the MV Grid
PublicationIn recent decades, a significant increase in the share of renewable energy sources in power grids at various voltage levels has been observed. A number of articles have been published highlighting emerging problems in low-voltage grids with a large share of prosumers and in medium- and high-voltage grids to which photovoltaic (PV) plants are connected. The article analyzes the medium-voltage grid in terms of the possibility of...
-
Nonlinear impedance as a function of A.C. voltage and temperature for Bi2VO5.5 ceramic of thickness 2.52 mm (after first heat-treatment at 913 K) was measured at different frequencies with impedance spectroscopy method
Open Research DataThe nonlinear electrical properties of Bi2VO5.5 ceramic of thickness 2.52 mm was measured by impedance spectroscopy method.
-
The Influence of Limiters UEL and OEL (The power angle, stator's current and excitation current) ot the possibility of voltage collapse development
PublicationVoltage stability has been a major concern for power system utilities because of event of voltage collapses in the recent past. Sometimes, power system events have shown the need for generators to operate in the overexcited and underexcited region to support stable operation. Modern excitation systems include devices for controlling or limiting machine terminal voltage (overvoltage limiters), volts per hertz ratio (V/Hz limiters),...
-
Four level inverter's DC bus voltage balancing with 3-terminal DAB converter
Publication—Multilevel inverters become more and more popular, especially in the medium or high voltage and high power applications. Unfortunately, some of inverter topologies require additional DC bus voltage balancing systems. This paper presents a novel approach to such systems, which is based on a multiple terminal DAB converter. Along with the voltage balancing function the proposed solution enables the connection of energy storage devices...
-
Voltage Source Power Line Conditioner for Applications in Local Supply Systems
PublicationThe paper presents the basic principles of operation of voltage source power line conditioners (VSPLC) as well as their energy and filtration properties. A 4-level cascade based Voltage Source Converter (VSC) is used as a voltage source. The advantages of this topology is relatively simple construction and simple way of balancing DC link voltages. Results of the theoretical and experimental investigations confirm good energetic...
-
Active Power Quality Controllers
PublicationDynamic Static Synchronous Compensator is the most important controller for distribution networks and probably in SEEN. It has been widely used since the 1990s to regulate system voltage precisely, improve voltage profile, reduce voltage harmonics, reduce transient voltage disturbances and load compensation. Rather than using conventional capacitors and inductors combined with fast switches, the D-STATCOM uses a power-electronics...
-
DC-link voltage balancing in cascaded H-Bridge converters
PublicationIn the paper a DC-link voltage balancing strategy for multilevel Cascaded H-Bridge (CHB) converter is proposed. Presented solution bases on optimal choice of active vector durations in Space-Vector Pulse Width Modulation (SV-PWM). It makes it possible to DC-link voltages control and to properly generate the output voltage vector in the case of DC-link voltage unbalance. Results of simulation and experimental researches...
-
Multi-pulse VSC arrangements with coupled reactors
PublicationThis paper presents a novel approach to the multipulse VSC (Voltage Source Converter) arrangements based on several conventional inverter modules connected in parallel by using coupled reactors. This solution reduces the THD of the output voltage, despite the low switching frequency of transistors. The advantage of the proposed solution is also a relatively small rated power of the reactors. Proposed new arrangements for different...
-
A New Approach to the PWM Modulation for the Multiphase Matrix Converters Supplying Loads with Open-End Winding.
PublicationThis article presents three variants of the Pulse Width Modulation (PWM) for the Double Square Multiphase type Conventional Matrix Converters (DSM-CMC) supplying loads with the open-end winding. The first variant of PWM offers the ability to obtain zero value of the common-mode voltage at the load's terminals and applies only six switches within the modulation period. The second proposal archives for less Total Harmonic Distortion...
-
Influence of the Square Wave Voltage on Dynamical Properties of a Flat Voltammetric Electrode in the Time Domain by the Electrochemical Reversible Reaction
PublicationIn this article there is a presentation of the analysis of the polarizing voltage shape influencing dynamic properties of voltammetric electrodes when on their surface reversible reaction takes place in the time domain. The electrode polarization with linearly increasing voltage and with a square component, was analyzed. The analysis that were conducted showed that the voltammetric electrode behaves like a first order transducer....
-
Conducted EMI Propagation Paths in DC-AC Hard Switching Converter
PublicationIn order to limit the electromagnetic interference (EMI) in power electronics devices, knowledge about the phenomena connected with EMI generation and propagation is necessary. This papers describes the propagation paths in the 3 phase voltage source inverter using wide-band simulation and laboratory test with the signal processing method Wiener filtering, where the transfer functions between voltage across switches and the perturbation...
-
Harmonics produced by traction substations – computer modelling and experimental verification
PublicationVoltage and current harmonics have a detrimental effect on the components of a power system. Current harmonics may result in the overload and damage to power transformers. Voltage harmonics may result in, for example, damage to capacitor banks used to compensate reactive power. Devices which contribute to both current and voltage distortion include traction rectifiers. This paper presents results of the computer investigation of...
-
Static Shunt PE Voltage-Quality Controllers
PublicationThis chapter focuses on power electronics (PE)-based solutions used in distribution networks for reduction of supply-voltage-quality deterioration, from long interruptions to the harmonics. Various PE devices and their combinations are addressed for particular or a range of voltage disturbances. A particular solution is applied taking into account demands for voltage quality and network configuration. In general, there are three...
-
Low harmonic multipulse voltage converters using coupled reactors
PublicationThis paper presents a novel approach to the multi pulse voltage converters (VC), especially voltage source inverters (VSI) and matrix converters (MC) based on several typical identical modules connected in parallel using coupled reactors. Such arrangements resulting in lower voltage distortions at extremely low switching frequency. The proposed arrangement was validated by simulation. Laboratory models of 18- and 24pulse 3-level...