Wyniki wyszukiwania dla: OPEN-PHASE FAULT DETECTION
-
Open-Phase Fault Detection Method for Sensorless Five-Phase Induction Motor Drives with an Inverter Output Filter
PublikacjaThe paper presents the sensorless five-phase induction motor drive implementation with an inverter output filter with third harmonic injection. For the sensorless operation, the required observers are presented for the first and third harmonics with consideration of the inverter output filter. Moreover, the interaction of the observers and the control system is capable to handle a deactivation of one or two phases, which improves...
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublikacjaA novel method is presented for the detection andisolation of open-transistor faults in voltage-source invertersfeeding low-power AC motors. The method is based onmonitoring two diagnostic signals, one indicating sustained nearzerovalues of output current and thus permitting fault detection,the other permitting the isolation of the particular transistorwhich went faulty. The latter signal is the ratio of the averagephase current...
-
Five-phase Induction Motor Drive Operation During Stator Phase Fault
PublikacjaThe article presents the most important advantages of multi-phase electric drives. The construction of a five-phase squirrel cage induction motor together with possible stator winding distribution cases is presented, which affect the properties of such motor. Increased reliability of five-phase drives was indicated. The drive operation properties were confirmed by experimental results.
-
Open-transistor fault diagnostics in voltage-source inverters by analyzing the load current
PublikacjaPrzedstawiono nową metodę detekcji i lokalizacji uszkodzeń polegających na braku przewodzenia tranzystorów w falownikach napięcia zasilających silniki indukcyjne. Metoda jest rozszerzeniem, opracowanej wcześniej, metody wykorzystującej znormalizowane składowe stałe prądów obciążenia. Znormalizowane wartości średnie prądów powiązano z dodatkowymi wskaźnikami diagnostycznymi, które zawierają informacje o czasie trwania nieprzewodzenia...
-
Sensorless field oriented control for five-phase induction motors with third harmonic injection and fault insensitive feature
PublikacjaThe paper presents a solution for sensorless field oriented control (FOC) system for five-phase induction motors with improved rotor flux pattern. In order to obtain the advantages of a third harmonic injection with a quasi-trapezoidal flux shape, two vector models, α1–β1 and α3–β3, were transformed into d1– q1, d3– q3 rotating frames, which correlate to the 1st and 3rd harmonic plane respectively. A linearization approach of the...
-
Fault-tolerant performance of the novel five-phase doubly-fed induction generator
PublikacjaThe article presents the concept of a new design of a multi-phase doubly-fed induction generator (DFIG). The innovative design approach uses a five-phase power supply from the rotor side of the generator with a three-phase classic stator power supply. Modern three-phase doubly-fed induction generators are the dominant choice for Wind Energy Conversion Systems (WECS). Solutions of this type are sensitive to the loss of at least...
-
Method of earth fault loop impedance measurement without nuisance tripping of RCDs in 3-phase low-voltage circuits
PublikacjaVerification of electrical safety in low-voltage power systems includes the measurement of earth fault loop impedance. This measurement is performed to verify the effectiveness of protection against indirect contact. The widespread classic methods and meters use a relatively high value of the measuring current (5–20) A, so that they are a source of nuisance tripping of residual current devices (RCDs). The meters dedicated to circuits...
-
Venetoclax in relapsed or refractory chronic lymphocytic leukaemia with 17p deletion: a multicentre, open-label, phase 2 study
Publikacja -
Ibrutinib as Treatment for Patients With Relapsed/Refractory Follicular Lymphoma: Results From the Open-Label, Multicenter, Phase II DAWN Study
Publikacja -
Ibrutinib versus temsirolimus in patients with relapsed or refractory mantle-cell lymphoma: an international, randomised, open-label, phase 3 study
Publikacja -
Ibrutinib versus temsirolimus: 3-year follow-up of patients with previously treated mantle cell lymphoma from the phase 3, international, randomized, open-label RAY study
Publikacja -
Health-related quality of life data from a phase 3, international, randomized, open-label, multicenter study in patients with previously treated mantle cell lymphoma treated with ibrutinib versus temsirolimus
Publikacja -
Broken Rotor Symptons in the Sensorless Control of Induction Machine
PublikacjaInverter fed sensorless controlled variable speed drives with induction machine are widely used in the industry applications, also in wind power generation and electric vehicles. On-line self diagnostic systems implementation is needed for early stage fault detection and avoiding a critical fault. Diagnostic algorithms in modern DSP-based controllers can operate simultaneously with control system functions. In the closed-loop controlled...
-
Detekcja i lokalizacja nieprzewodzenia tranzystorów falownika napięcia na podstawie analizy prądu obciążenia
PublikacjaPrzedstawiono nową metodę detekcji i lokalizacji nieprzewodzenia tranzystorów w falownikach napięcia zasilających silniki indukcyjne małej mocy. Metoda bazuje na monitorowaniu wartości dwóch sygnałów dia-gnostycznych. Pierwszy z nich, wskaźnik braku przepływu prądu, wykorzystano w celu detekcji uszkodzeń. Drugi, stosunek wartości średniej prądu do wartości średniej bezwzględnej, zawiera informacje umożliwiające lokalizację uszkodzonych...
-
Faults and Fault Detection Methods in Electric Drives
PublikacjaThe chapter presents a review of faults and fault detection methods in electric drives. Typical faults are presented that arises for the induction motor, which is valued in the industry for its robust construction and cost-effective production. Moreover, a summary is presented of detectable faults in conjunction with the required physical information that allow a detection of specific faults. In order to address faults of a complete...
-
Broken rotor bar impact on sensorless control of induction machine
PublikacjaThe aim of the research is analysis of the sensorless control system of induction machine with broken rotor for diagnostic purposes. Increasing popularity of sensorless controlled variable speed drives requires research in area of reliability, range of stable operation, fault symptoms and application of diagnosis methods. T transformation (Cunha et al.,2003) used for conversion of instantaneous rotor currents electrical circuit...
-
Time-current tripping curves of arc fault detection devices
PublikacjaTripping curves of arc fault detection devices, in accordance with PN-EN 62606 “General requirements for arc fault detection devices” have been presented in the paper. Consequently the most fundamental differences in arc fault detection devices tripping compared to circuit-breakers and residual current devices have been indicated.
-
Possibility of Fault Detection in Sensorless Electric Drives
PublikacjaThe work presents a fault detection method for an induction motor drive system with inverter output filter. This approach make use of a load torque state observer, which complete structure is presented along with the used control structure. Moreover, the demonstrated drive system operates without rotor speed measurement in conjunction with the multiscalar control. The verification of the demonstrated idea was performed on an experimental...
-
Nonlinear Model of Synchronous Generator for Autonomous Electrical Power Systems Analysis
PublikacjaThis paper presents the nonlinear lookup table model for synchronous generator (SG) analysis. The saturation effects of the SG magnetic circuit have been considered. The saturated characteristic of the SG magnetic circuit are based on the open circuit saturation curve for magnetizing inductances. The model has been implemented into the Synopsys/Saber software using the MAST modelling language. To implement the no-load voltage characteristic...
-
The effectivness of fault detection in common rail injectors examination methods
PublikacjaThe article presents the effectiveness tests of fault detection in common rail injectors. 40 injectors with different wear levels were tested. Testing was made on two test benches of a completely different design. Research includes comparison of accuracy, reproducibility and testability to detect specific defects. A device was created for visualization of the fuel injector spraying steam.
-
Sensorless Fault Detection of Induction Motor with Inverter Output Filter
PublikacjaThe paper presents the problem of monitoring and fault detection of a sensorless voltage inverter fed squirrel cage induction motor with LC filter. The detection is based on load torque estimation of the investigated torque transmission system. The load torque is calculated besides the computation of other variables that are mandatory for sensorless drive operation such as rotor flux and speed. The implemented LC filter smooths...
-
Fault detection in electronic circuits using test buses
PublikacjaA survey of test buses designed for diagnostics of digital and analog electronic circuits is presented: the IEEE 1149.1 bus for digital circuits, the IEEE 1149.4 bus for mixed-signal and the IEEE 1149.6 bus for AC coupled complex digital circuits. Each bus is presented with its structure, solution of key elements, particularly boundary registers and a set of test instructions. Diagnosis with the use of the described buses is...
-
Fault detection in the marine engine using a support vector data description method
PublikacjaFast detection and correct diagnosis of any engine condition changes are essential elements of safety andenvironmental protection. Many diagnostic algorithms significantly improve the detection of malfunctions.Studies on diagnostic methods are rarely reported and even less implemented in the marine engine industry.To fill this gap, this paper presents the Support Vector Data Description (SVDD) method as applied to thefault detection...
-
Data-driven models for fault detection using kernel pca:a water distribution system case study
PublikacjaKernel Principal Component Analysis (KPCA), an example of machine learning, can be considered a non-linear extension of the PCA method. While various applications of KPCA are known, this paper explores the possibility to use it for building a data-driven model of a non-linear system-the water distribution system of the Chojnice town (Poland). This model is utilised for fault detection with the emphasis on water leakage detection....
-
Fault detection and diagnostics of complex dynamic systems using Gaussian Process Models - nuclear power plant case study
PublikacjaThe article examines the use of Gaussian Process Models to simulate the dynamic processes of a Pressurized Water nuclear Reactor for fault detection and diagnostics. The paper illustrates the potential of Gaussian Process Models as a tool for monitoring and predicting various fault conditions in Pressurized Water nuclear Reactor power plants, including reactor coolant flow and temperature variations, deviations from nominal working...
-
Accuracy of Differential Phase Delay Estimation for GPS Spoofing Detection
PublikacjaGPS spoofing is an attack based on transmission of false signals to target receivers, in order to force the computation of incorrect time, position or velocity information. It is a threat which is recently considered with continuously growing awareness. There is a need for effective way of GPS spoofing detection. Many groups of methods are proposed in the literature. Spatial processing methods are considered to be robust in a wide...
-
Speed Sensorless AC Drive with Inverter LC Filter and Fault Detection Using Load Torque Signal
PublikacjaThe industrial development in recent years has seen a major increase in the use of induction motors, whereby the cost has to be as low as possible and the lifetime as long as possible. To follow up this desire, investigations in this area have become very intense. For that reason, this paper presents a solution for driving an induction motor and simultaneous fault detection with no need for additional sensors. In order to achieve...
-
Speed sensorless ac drive with inverter output filter and fault detection using load torque signal
PublikacjaIn this paper, a sensorless induction motor (IM) drive using speed observer system is presented. The system includes load torque computation for gear fault detection. Nonlinear control method is adopted for controlling the motor over a wide speed range. An LC filter for smoothing current and voltage waveforms is used at the output of the voltage inverter. The use of filter imposes more building of the used observer to avoid using...
-
Fault detection in measuring systems of power plants
PublikacjaThis paper describes possibility of forming diagnostic relations based on application of the artifical neural networks (ANNs), intended for the identifying of degradation of measuring instruments used in developed power systems. As an example a steam turbine high-power plant was used. And, simulative calculations were applied to forming diagnostic neural relations. Both degradation of the measuring instruments and simultaneously...
-
Sensorless Disturbance Detection for Five Phase Induction Motor with Third Harmonic Injection
PublikacjaThe paper presents a sensorless disturbance detection procedure that was done on a five phase induction motor with third harmonic injection. A test bench was developed where a three phase machine serves as disturbance generator of different frequencies. The control of the machines is based on multi scalar variables that ensures an independent control of the motor EMF and the rotor flux. For disturbance identification a speed observer...
-
Zdzisław Kowalczuk prof. dr hab. inż.
OsobyW 1978 ukończył studia w zakresie automatyki i informatyki na Wydziale Elektroniki Politechniki Gdańskiej, następnie rozpoczął pracę na macierzystej uczelni. W 1986 obronił pracę doktorską, w 1993 habilitował się na Politechnice Śląskiej na podstawie pracy Dyskretne modele w projektowaniu układów sterowania. W 1996 mianowany profesorem nadzwyczajnym, w 2003 otrzymał tytuł profesora nauk technicznych. W 2006 założył i od tego czasu...
-
On Wilcoxon rank sum test for condition monitoring and fault detection of wind turbines
Publikacja -
Implementation of DEIS for reliable fault monitoring and detection in PEMFC single cells and stacks
PublikacjaDynamic Electrochemical Impedance Spectroscopy (DEIS) was presented as novel method for diagnostic and monitoring of PEMFC stack and single cells operation. Impedance characteristics were obtained simultaneously with current - voltage characteristics for stack and each individual cell. Impedance measurements were performed in galvanodynamic mode. It allowed to compare performance of each cell and identification of faulty cell operation...
-
Simultaneous Determination of Indolic Compounds in Plant Extracts by Solid-Phase Extraction and High-Performance Liquid Chromatography with UV and Fluorescence Detection
PublikacjaA high-performance liquid chromatographic method with UV and fluorescence detection (HPLC-DAD-FLD) was developed for simultaneous determination of indolic compounds in plant material. Indole-3-carbinol (I3C), indole-3-acetic acid (I3AA), indole-3-acetonitrile (I3ACN), and 3,3′-diindolylmethane (DIM) were used as representative compounds that cover a wide spectrum of indole structures occurring in nature. For concentration and purification...
-
Condition monitoring and fault detection in wind turbines based on cointegration analysis of SCADA data
Publikacja -
On Cointegration Analysis for Condition Monitoring and Fault Detection of Wind Turbines Using SCADA Data
Publikacja -
Modification of the operating point of residual current transformers for high frequency earth fault currents detection
PublikacjaFor protection against electric shock in low voltage systems residual current devices are commonly used. However, their proper operation can be interfered when earth fault current with high frequency components occurs. Serious hazard of electrocution exists then. One of the most important element of residual current devices is a residual current transformer with iron core. Tripping characteristic of residual current devices strictly...
-
Condition monitoring and fault diagnosis of wind turbines based on structural break detection in SCADA data
Publikacja -
A solid phase extraction–ion chromatography with conductivity detection procedure for determining cationic surfactants in surface water samples
PublikacjaA new analytical procedure for the simultaneous determination of individual cationic surfactants (alkyl benzyl dimethyl ammonium chlorides) in surface water samples has been developed. We describe this methodology for the first time: it involves the application of solid phase extraction (SPE – for sample preparation) coupled with ion chromatography–conductivity detection (IC-CD – for the final determination). Mean recoveries of...
-
Michał Grochowski dr hab. inż.
OsobyProfessor and a Head of the Department of Intelligent Control and Decision Support Systems at Gdansk University of Technology (GUT). He is also a Member of the Board of the Digital Technologies Center of GUT. He received his M.Sc. degree in Control Engineering in 2000 from the Electrical and Control Engineering Faculty at the GUT. In 2004 he received a Ph.D. degree in Automatic Control and Robotics from this...
-
Data-driven models for fault detection using kernel PCA: A water distribution system case study
Publikacja -
Silica-Based Ionogels: Nanoconfined Ionic Liquid-Rich Fibers for Headspace Solid-Phase Microextraction Coupled with Gas Chromatography–Barrier Discharge Ionization Detection
PublikacjaIn this work, hybrid silica-based materials with immobilized ionic liquids (ILs) were prepared by sol–gel technology and evaluated as solid-phase microextraction (SPME) fiber coatings. High loadings of the IL 1-methyl-3-butylimidazolium bis(trifluoromethylsulfonyl)imide ([C4MIM][TFSI]) were confined within the hybrid network. Coatings composition and morphology were evaluated using scanning electron microscopy and energy dispersive...
-
Headspace Liquid-Phase Microextraction of Chlorobenzenes in Soil with Gas Chromatography-Electron Capture Detection
Publikacja -
Operational System Modelling in a Focused Fire Alarm System with an Open and Signal Detection Circuit Supervising Railway Station Premises
Publikacja -
Determination of fluoride as fluorosilane derivative using reversed-phase HPLC with UV detection for determination of total organic fluorine
Publikacja -
Determination of volatile aliphatic amines in air by solid phase microex traction coupled with gas chromatography with flame ionization detection.
PublikacjaOpisano nową metodę oznaczania lotnych amin alifatycznych w powietrzu. Metodyka oparta jest na zastosowaniu techniki mikroekstrakcji do fazy stacjonarnej na etapie pobierania próbek oraz zestawu GC-FID do rozdzielania i oznaczania poszczególnych analitów.Badaniom poddano nowe typy faz stacjonarnych.Zbadano wpływ wilgotności powietrza na proces pobierania próbek analitów z powietrza.
-
IFAC Symposium on Fault Detection, Supervision and Safety of Technical Processes
Konferencje -
Self-Testing of Analog Parts Terminated by ADCs Based on Multiple Sampling of Time Responses
PublikacjaA new approach for self-testing of analog parts terminated by analog-to-digital converters in mixed-signal electronic microsystems controlled by microcontrollers is presented. It is based upon a new fault diagnosis method using a transformation of the set of voltage samples of the time response of a tested analog part to a square impulse into localization curves placed in a multidimensional measurement space. The method can be used...
-
Jacek Ryl dr hab. inż.
OsobyStopień doktora nauk technicznych uzyskał w roku 2010. W tym samym roku podjął pracę w Katedrze Elektrochemii, Korozji i Inżynierii Materiałowej na Wydziale Chemicznym. W 2018 roku uzyskał stopień doktora habilitowanego nauk technicznych w dyscyplinie technologia chemiczna. Od 2021 roku zatrudniony w Instytucie Nanotechnologii i Inżynierii Materiałowej Wydziału Fizyki Technicznej i Matematyki Stosowanej PG. W pracy naukowej skupia...
-
Application of data driven methods in diagnostic of selected process faults of nuclear power plant steam turbine
PublikacjaArticle presents a comparison of process anomaly detection in nuclear power plant steam turbine using combination of data driven methods. Three types of faults are considered: water hammering, fouling and thermocouple fault. As a virtual plant a nonlinear, dynamic, mathe- matical steam turbine model is used. Two approaches for fault detection using one class and two class classiers are tested and compared.
-
A method of self-testing of an analog circuit terminated by an ADC in electronic embedded systems controlled by microcontrollers
PublikacjaA new self-testing method of analog parts terminated by an ADC in electronic embedded systems controlled by microcontrollers is presented. It is based on a new fault diagnosis method based on on-line (i.e. during measurement), transformations of voltage samples of the time response of a tested part to a square pulse - onto localization curves placed in the measurement space. The method can be used for fault detection and single...
-
A method of self-testing of analog circuits based on fully differential op-amps with theTCBF classifier
PublikacjaA new approach of self-testing of analog circuits based on fully differential op-amps of mixed-signal systems controlled by microcontrollers is presented. It consists of a measurement procedure and a fault diagnosis procedure. We measure voltage samples of a time response of a tested circuit on a stimulation of a unit step function given at the common-mode reference voltage input of the op-amp. The fault detection and fault localization...
-
A testing method of analog parts of mixed-signal electronic systems equipped with the IEEE1149.1 test bus
PublikacjaA new solution of the JTAG BIST for testing analog circuits in mixed-signal electronic microsystems controlled by microcontrollers and equipped with the IEEE1149.1 bus is presented. It is based on a new fault diagnosis method in which an analog circuit is stimulated by a buffered signal from the TMS line, and the time response of the circuit to this signal is sampled by the ADC equipped with the JTAG. The method can be used for...
-
Practical issues for the implementation of survivability and recovery techniques in optical networks
PublikacjaFailures in optical networks are inevitable. They may occur during work being done for the maintenance of other infrastructures, or on a larger scale as the result of an attack or large-scale disaster. As a result, service availability, an important aspect of Quality of Service (QoS), is often degraded. Appropriate fault recovery techniques are thus crucial to meet the requirements set by the Service Level Agreements (SLAs) between...
-
Optimising approach to designing kernel PCA model for diagnosis purposes with and without a priori known data reflecting faulty states
PublikacjaFault detection plays an important role in advanced control of complex dynamic systems since precise information about system condition enables efficient control. Data driven methods of fault detection give the chance to monitor the plant state purely based on gathered measurements. However, they especially nonlinear, still suffer from a lack of efficient and effective learning methods. In this paper we propose the two stages learning...
-
Using an IEEE1149.1 Test Bus for Fault Diagnosis of Analog Parts of Electronic Embedded Systems
PublikacjaThe new solution of a BIST called the JTAG BIST for self-testing of analog parts of electronic embedded systems is presented in the paper. The JTAG BIST consists of the BCT8244A and SCANSTA476 integrated circuits of Texas Instruments controlled via the IEEE 1149.1 bus. The BCT8244A is a scan test device with octal buffers, and the SCANSTA476 is a 12-bit ADC with 8 analog input channels. Self-testing approach is based on the fault...
-
Analysis and Detection of Faults at Insulated Conductors of Overhead Medium Voltage Lines
PublikacjaThe paper dealt with the issue of breakdowns detection of isolated hanging wires on the medium-voltage transmission. The main aim of article is to describe the function of created breakdowns detector and evaluation its. The breakdowns detector is created based in indicators of faults such as touch between tree limbs and insulated wire, touch tree limbs with several phases or fall insulated wire on the ground. Breakdowns detector...
-
Application of RCD and AFDD in low-voltage electrical installations for protection against fire
PublikacjaThe paper presents the principles of application of residual current devices (RCDs) in protection against fire. The permissible rated residual operating current of RCDs is discussed. Limitations in the operation of RCDs in this type of protection are indicated. A new type of a protective device against fire – arc fault detection device (AFDD) – is described.
-
Computer-aided Analysis of Induced Sheath Voltages in High Voltage Power Cable System
PublikacjaThis paper concerns the effect of configuration of high voltage power cables on induced voltages in their metallic sheaths. One, two or three cables per phase and phase sequence of the cables are considered. Computing of the voltages was performed for a normal operation and in case of earth fault. Various ways of the sheaths bonding are considered as well. Shock hazard and voltage stress of non-metallic outer sheath of cables are...
-
Use of Neural Networks in Diagnostics of Rolling-Element Bearing of the Induction Motor
PublikacjaBearing defect is statistically the most frequent cause of an induction motor fault. The research described in the paper utilized the phenomenon of the current change in the induction motor with bearing defect. Methods based on the analysis of the supplying current are particularly useful when it is impossible to install diagnostic devices directly on the motor. The presented method of rolling-element bearing diagnostics used indirect...
-
Fault Diagnostics in PEMFC Stacks by Evaluation of Local Performance and Cell Impedance Analysis
PublikacjaStarvation, flooding, and dry‐out phenomena occur in polymer electrolyte membrane fuel cells (PEMFCs), due to heterogeneous local conditions, material inhomogeneity, and uneven flow distribution across the single cell active area and in between the individual cells. The impact of the load level and air feed conditions on the performance was identified for individual single cells within a 10‐cell stack. Analysis of the current density...
-
Diagnostics of thermal processes in antenna systems of broadcast stations
PublikacjaDiagnostics is an important element associated with the operation of a radio antenna systems, allowing earlier detection of potential damage. Thermography is one of the diagnostic tools, which allows for non-invasive assessment of technical condition. It brings together both financial savings associated with the removal of the damage and the potential effects caused by it. The article presents an example of using a thermal imaging...
-
Kernel PCA in Application to Leakage Detection in Drinking Water Distribution System
PublikacjaMonitoring plays an important role in advanced control of complex dynamic systems. Precise information about system's behaviour, including faults detection, enables efficient control. Proposed method- Kernel Principal Component Analysis (KPCA), a representative of machine learning, skilfully takes full advantage of the well known PCA method and extends its application to nonlinear case. The paper explains the general idea of KPCA...
-
Mathematical Approach to Assess a Human Gait
PublikacjaA purpose of the paper was to create a mathematical approach to assess a human gait. The scope of the study was to model a normal gait in the sagittal plane and frontal plane of the body. Applying the Newton-Euler formulation, three multibody biomechanical models were derived to describe single support phase and double support phase of the gait. To model a gait in the sagittal plane the open-close sagittal 6DOF model and the open-close...
-
Service-based Resilience via Shared Protection in Mission-critical Embedded Networks
PublikacjaMission-critical networks, which for example can be found in autonomous cars and avionics, are complex systems with a multitude of interconnected embedded nodes and various service demands. Their resilience against failures and attacks is a crucial property and has to be already considered in their design phase. In this paper, we introduce a novel approach for optimal joint service allocation and routing, leveraging virtualized...
-
Demonstrator testera wbudowanego BIST dla układów w pełni różnicowych
PublikacjaPrzedstawiono demonstrator testera wbudowanego, przeznaczony do pracy na stanowisku dydaktycznym w laboratorium z przedmiotu Zaawansowane Metody Pomiarowe i Diagnostyczne. Na stanowisku studenci zapoznają się z technologią BIST (ang. Built-In Self-Test), która jest przykładem wdrożenia strategii projektowania dla testowania.
-
PCA based Fault Tolerant MPC
PublikacjaThis chapter presents a Fault Tolerant - Model Predictive Control (FT-MPC) schemes for sensor faults accommodation. A Fault Detection and Isolation (FDI) Unit, which is an integral part of FT-MPC system, is based on the Principal Component Analysis (PCA) method. Introduced approach enables efficient bias and drift faults accommodation in single, as well as simultaneous faults case. Simple simulation exercise is presented.Rozdział...
-
Fault diagnosis of marine 4-stroke diesel engines using a one-vs-one extreme learning ensemble
PublikacjaThis paper proposes a novel approach for intelligent fault diagnosis for stroke Diesel marine engines, which are commonly used in on-road and marine transportation. The safety and reliability of a ship's work rely strongly on the performance of such an engine; therefore, early detection of any type of failure that affects the engine is of crucial importance. Automatic diagnostic systems are of special importance because they can...
-
Review of Methods for Diagnosing the Degradation Process in Power Units Cooperating with Renewable Energy Sources Using Artificial Intelligence
PublikacjaThis work is based on a literature review (191). It mainly refers to two diagnostic methods based on artificial intelligence. This review presents new possibilities for using genetic algorithms (GAs) for diagnostic purposes in power plants transitioning to cooperation with renewable energy sources (RESs). The genetic method is rarely used directly in the modeling of thermal-flow analysis. However, this assignment proves that the...
-
Performance analysis of power swing blocking feature in ABB 670 series impedance relays
PublikacjaThis paper presents test results of a distance protection’s PSD power swing detection feature in ABB 670 series relays. A RED670 relay was tested, which is part of the hydroelectric set protection in Żarnowiec Pumped Storage Plant. The power swing blocking feature’s performance was analysed on the basis of the results of object tests made with an Omicron digital tester. Also presented are simulation results that illustrate the...
-
Detection and Mitigation of GPS Spoofing Based on Antenna Array Processing
PublikacjaIn this article authors present an application of spatial processing methods for GPS spoofing detection and mitigation. In the first part of this article, a spoofing detection method, based on phase delay measurements, is proposed. Accuracy and precision of phase delay estimation is assessed for various qualities of received signal. Spoofing detection thresholds are determined. Efficiency of this method is evaluated in terms of...
-
Diagnostyka analogowych filtrów wielosekcyjnych oparta na magistrali testującej IEEE1149.1
PublikacjaPrzedstawiono nową koncepcję testera JTAG BIST do samo-testowania torów analogowych opartych na wielosekcyjnych filtrach wyższego rzędu w mieszanych sygnałowo mikrosystemach elektronicznych sterowanych mikrokontrolerami i wyposażonych w magistralę testującą IEEE1149.1 (JTAG). Bazuje ona na metodzie diagnostycznej opartej na przekształce-niu transformującym próbki odpowiedzi czasowych kolejnych sekcji filtra pobudzonego impulsem...
-
Adaptive dynamic control allocation for dynamic positioning of marine vessel based on backstepping method and sequential quadratic programming
PublikacjaIt is generally assumed in dynamic positioning of over-actuated marine vessels that the control effectiveness matrix (input matrix) is known and constant, or, in case of fault information, it is estimated by the fault detection and diagnosis system. The purpose of the study is to develop the adaptive dynamic positioning control system for an over-actuated marine vessel in the presence of uncertainties and with emphasis on limited...
-
Samotestowanie toru analogowego ze wzmacniaczem w pełni różnicowym w elektronicznych systemach wbudowanych sterowanych mikrokontrole-rami
PublikacjaPrzedstawiono nową metodę samotestowania toru analogowego opartego na wzmacniaczu w pełni różnicowym w elektronicznych systemach wbu-dowanych sterowanych mikrokontrolerami. Bazuje ona na nowej metodzie diagnostycznej opartej na przekształceniu transformującym próbki odpo-wiedzi czasowej badanej części analogowej na pobudzenie "ujemnym" impulsem prostokątnym na wejściu Vocm na krzywe identyfikacyjne w przestrzeni pomiarowej. Metoda...
-
Tripping of F-type RCDs for high-frequency residual currents
PublikacjaResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs are...
-
Tripping of F-type RCDs for High-Frequency Residual Currents
PublikacjaResidual current devices (RCDs) are apparatus commonly used for protection against electric shock in low-voltage electrical installations. They protect people in the case of an earth fault or even in the case of direct contact with the live parts. However, to be effective protective devices, RCDs have to detect residual currents of various waveform shapes which appear in modern electrical installations. For this purpose, RCDs...
-
Residual Current Devices: Selection, Operation, and Testing
PublikacjaIn this book, the idea for residual current protection has been presented. The evolution in construction types of residual current devices, which has taken place over decades, is discussed. Types and functional properties of the contemporary residual current devices are described. The main parameters of these devices, from the point of view of their selection and application, are indicated. Special constructions of the protective...
-
Classification of Sea Going Vessels Properties Using SAR Satellite Images
PublikacjaThe aim of the project was to analyze the possibility of using machine learning and computer vision to identify (indicate the location) of all sea-going vessels located in the selected area of the open sea and to classify the main attributes of the vessel. The key elements of the project were to download data from the Sentinel-1 satellite [1], download data on the sea vessels [2], then automatically tag data and develop a detection...
-
Sensorless five-phase induction motor drive with third harmonic injection and inverter output filter
PublikacjaThe paper presents a sensorless control approach for a five-phase induction motor drive with third harmonic injection and inverter output filter. In the case of the third harmonic injection being utilised in the control, the physical machine has to be divided into two virtual machines that are controlled separately and independently. The control system structure is presented in conjunction with speed and rotor flux observers that...
-
Diver Observations by Means of Acoustic Methods
PublikacjaSearching for objects, especially small ones, moving under water near its the free surface, is always not an easy task. Designing tools for the detection of such targets is a real challenge when the possibility of a terrorist attack is a real threat. This paper presents some aspects of diver detection by means of acoustics methods, both active (side scan sonar) and passive ones (linear receiving antenna). This approach is quite...
-
The effect of current delay angle on tripping of residual current devices
PublikacjaPower electronics converters applied in domestic or similar installations may utilize current delay (phase) angle control to change the level of transferred power. Due to application of such types of converters, earth fault current in the installation may be strongly distorted. The current distortion level depends on a value of current delay angle. This delay angle also influences the tripping threshold of residual current devices....
-
Highly sensitive microwave sensors based on open complementary square split-ring resonator for sensing liquid materials
PublikacjaThis paper presents high-sensitivity sensors based on open complementary square split-ring resonator and modified open complementary split-ring resonator operating at 4.5 GHz and 3.4 GHz, respectively. The sensors are designed for the detection of multiple liquid materials, including distilled water, methanol, and ethanol. The liquid under test is filled in a glass container loaded using a pipette. Compared to the conventional...
-
СИСТЕМА КОНТРОЛЯ СОСТОЯНИЯ ИЗОЛЯЦИИ ЭЛЕКТРОПРИВОДОВ В СЕТЯХ С ГЛУХОЗАЗЕМЛЕННОЙ НЕЙТРАЛЬЮ (System of insulation status monitoring for electric drives in networks with a dead-earth neutral)
PublikacjaПредложен метод контроля изоляции частотно-регулируемых электроприводов в сетях с глухозаземленной нейтралью. Система контроля изоляции включается в момент остановки электропривода. Ключи инвертора коммутируются по специальному закону, и с помощью сигнала трансформатора тока, который изме- ряет ток во всех трех фазах привода одновременно, определяется ток утечки. Рассмотрена схема датчика тока утечки и приведены экспериментальные...
-
Earth wires currents calculation by tableau analysis
PublikacjaThe paper presents a new method to compute a phase-to-earth fault current distribution in overhead transmission line. The method is based on the tableau analysis of an unbalanced, multi-wire model of a transmission line. It allows for the calculation of current distribution in overhead earth wires along the transmission line. Additionally, it may be used to calculate currents in a tower’s earthing system as well as voltages over...
-
Activity assay of O-Acetyl-L-homoserine sulfhydrylase (CaMet15p).
Dane BadawczeThe study aimed to obtain conditions optimal for the activity of O-acetyl-L-homoserine sulfhydrylase (CaMet15p) and a method suitable for its measurement. The selection of appropriate reaction conditions included the identification of the reaction buffer and its pH, substrate and enzyme concentrations. The activity of CaMet15p was measured by the detection...
-
Next generation automatic IP configuration deployment issues
PublikacjaAlthough Dynamic Host Configuration Protocol for IPv6 (DHCPv6) protocol was defined in 2003, it was designed as a framework rather than a complete solution to the automatic configuration in IPv6 networks. There are still some unsolved problems and new options yet to be defined. One example of such case is Fully Qualified Domain Name (FQDN) option, which final version has been published in late 2007. It describes DHCPv6 client...
-
Integration, Processing and Dissemination of LiDAR Data in a 3D Web-GIS
PublikacjaThe rapid increase in applications of Light Detection and Ranging (LiDAR) scanners, followed by the development of various methods that are dedicated for survey data processing, visualization, and dissemination constituted the need of new open standards for storage and online distribution of collected three-dimensional data. However, over a decade of research in the area has resulted in a number of incompatible solutions that offer...
-
Guided waves for monitoring of plate structures with linear cracks of variable length
PublikacjaDamage occurring at the work of plate structures may grow to a considerable size. The joint action – the detection of a defect at the earliest possible stage, the monitoring of its growth and the determination of its critical size in the context of structural reliability allows optimizing the cost of the maintenance and repair of structural elements. Thus the development of monitoring systems for permanent observation of fault...
-
Shady S. Refaat
OsobyShady S. Refaat received the B.A.Sc, M.A.Sc., and Ph.D. degrees in Electrical Engineering in 2002, 2007, and 2013, respectively, all from Cairo University, Giza, Egypt. He has worked in the industry for more than 12 years as Engineering Team Leader, Senior Electrical Engineer, and Electrical Design Engineer on various electrical engineering projects. He has worked as an associate research scientist in the Department of Electrical...
-
Common methods for the chiral determination of amphetamine and related compounds I. Gas, liquid and thin-layer chromatography
PublikacjaThis article reviews the most common, useful methods for the chiral determination of amphetamine (AM) and AM-deriveddesigner drugs in different of matrix, including blood, hair, urine, medicaments or standard solutions, taking into considerationarticles published in the past 15 years. We consider chromatographic methods (e.g., gas, liquid, high-performance liquid, and thinlayer). We describe several types of chiral derivatization...
-
Biomolecular influenza virus detection based on the electrochemical impedance spectroscopy using the nanocrystalline boron-doped diamond electrodes with covalently bound antibodies
PublikacjaNew rapid pathogen detection methods with improved cost-effectiveness and efficiency are currently in the focus of the scientists from all over the world. Based on the experiences from the rapid spread of the influenza virus pandemic in 2009 it is clear that the development of the system for early diagnosis of this infection is essential. The crucial stage of the treatment is the detection of the viral infection during its initial...
-
Quantification of unconjugated and total ibuprofen and its metabolites in equine urine samples by gas chromatography–tandem mass spectrometry: Application to the excretion study
PublikacjaIbuprofen (IBU) is a widely used nonsteroidal anti-inflammatory drug (NSAID) in human and also veterinary medicine. NSAIDs are usually highly metabolized compounds in horses; they are often present in equine urine, mostly in their conjugated forms (glucuronides). Thus, hydrolysis to cleave the glucuronide linkage prior to anti-doping analysis is often necessary for improving detection. In this study, unconjugated and total IBU...
-
Dopants and gas modifiers in ion mobility spectrometry
PublikacjaThe ion mobility techniques, including the most commonly used drift-tube ion mobility spectrometry (IMS) and differential mobility spectrometry (DMS), are used successfully for the detection of a wide range of organic compounds in the gas phase. In order to improve detection quality, admixtures are added to gas streams flowing through the detector. Dopants mostly prevent the ionization of interfering chemicals however, better detection...
-
On extending open source IMS platform for integrated IPTV and VoIP services over IPv6
PublikacjaEven when IMS is the most popular platform for multimedia services, the open versions of IMS ecosystem are lacking in specified functionalities for IPTVv6 and VoIPv6 services. In this paper, we extend current client and server open source software in order to provide reliability and security to these multimedia services. As a part of our work the IMS architecture for conferencing system with proposed mechanisms to improve system...
-
Elimination of impulsive disturbances from archive audio files – comparison of three noise pulse detection schemes
PublikacjaThe problem of elimination of impulsive disturbances (such as clicks, pops, ticks, crackles, and record scratches) from archive audio recordings is considered and solved using autoregressive modeling. Three classical noise pulse detection schemes are examined and compared: the approach based on open-loop multi-step-ahead signal prediction, the approach based on decision-feedback signal prediction, and the double threshold approach,...
-
Open-Set Speaker Identification Using Closed-Set Pretrained Embeddings
PublikacjaThe paper proposes an approach for extending deep neural networks-based solutions to closed-set speaker identification toward the open-set problem. The idea is built on the characteristics of deep neural networks trained for the classification tasks, where there is a layer consisting of a set of deep features extracted from the analyzed inputs. By extracting this vector and performing anomaly detection against the set of known...
-
Oxide nanoparticle exsolution in Lu-doped (Ba,La)CoO3
PublikacjaThis study investigated Lu doping of Ba0.5La0.5CoO3 and its influence on the exsolution of oxide nanoparticles (NPs). As a result of Lu doping, we observed the phase segregation into the main Ba0.4La0.6Co0.85Lu0.15O3 (BLCO–Lu) phase and the secondary Ba0.85La0.15Co0.75Lu0.25O3 (BCO–Lu) phase. We noticed the exsolution of BCO–Lu nanoparticles on the main BLCO–Lu phase. Moreover, the BLCO–Lu phase exsolved in the form of nanoparticles...
-
Synthesis and Testing of BCZY/LNZ Mixed Proton–electron Conducting Composites for Fuel Cell Applications
PublikacjaA composite of BaCe0.6Zr0.2Y0.2O3–δ and Li2O:NiO:ZnO was investigated for fuel cell applications. The composite was successfully synthesized and its phase stability was confirmed at temperatures up to 900 °C. The influence of sintering and pressing aids on density was also investigated. Electrical properties were measured. DC electrical conductivity was about 8•10-4 S/m at 845 K. Open circuit voltage measurements in wet hydrogen...
-
Involvement of human glutathione S-transferase M1-1 in the glutathione conjugation of the antitumor unsymmetrical bisacridine derivative C-2028.
Dane BadawczeUnsymmetrical bisacridines (UAs) are a novel potent class of antitumor-active therapeutics. The aim of this study was to investigate the possible role of human glutathione S-transferase M1-1 (hGSTM1-1) in the glutathione (GSH) conjugation of a representative UA, C‑2028.
-
Detection and Direction-of-Arrival Estimation of Weak Spread Spectrum Signals Received with Antenna Array
PublikacjaThis paper presents a method for the joint detection and direction of arrival (DOA) estimation of low probability of detection (LPD) signals. The proposed approach is based on using the antenna array to receive spread-spectrum signals hidden below the noise floor. Array processing exploits the spatial correlation between phase-delayed copies of the signal and allows us to evaluate the parameter used to make the decision about the...