Search results for: electrodes
-
Evolution of electrohydrodynamic flow of sduspended particles in a needle-to-plate negative DC corona discharge in air
PublicationCorona discharges are used for collecting dust in electrostatic precipitators (ESPs). The dust collection is mainlyrealized by the electric forces which move the ionized dust particles to the collecting electrodes. However, the presence of coronadischarge in the space between the charging and collecting electrodes in ESPs causes also the so-called ionic wind which set the gasmolecules and dust...
-
Electrochemical studies of poly(lactic acid)-carbon black-nanodiamond composites
Open Research DataThis dataset contains electrochemical investigation on electrodes 3D printed using a new composite composed of poly-lactic acid (PLA), carbon black (CB) and nanodiamond fillers. Two types of nanodiamonds were studied: detonation nanodiamonds (DND) and boron-doped carbon nanowalls (BCNW). The presented results contain:1. electrochemical characterisation...
-
Effect of electrode resistance on admittance spectra of planar organic device carrying SCLC and on charge carrier mobility extracted from susceptance
PublicationThe work presents small signal admittance spectra of a sandwich system with thin organic layer carrying a space charge limited current. The effect of series resistance of electrodes on the spectra is discussed. Spectra of small signal capacitance are added to get more detailed insight. The analysis performed shows that the series resistance can affect both parts of small signal response within a whole range of frequency. Moreover,...
-
Hydrogen sulphide electrocatalytic gas sensor
PublicationIn this article measurement results of the electrocatalytic gas sensor in different concentrations of hydrogen sulphide are presented. Working principle of such sensor is based on electric current acquisition, while voltage ramp is applied to the sensor. During voltage sweep oxidation and reduction reactions occurs on the sensor electrodes. Obtained current-voltage plot has unique shape connected...
-
THE EFFECT OF WET UNDERWATER WELDING ON COLD CRACKING SUSCEPTIBILITY OF DUPLEX STAINLESS STEEL
PublicationABSTRACT The present work was conducted to assess the weldability of duplex stainless steel in underwater conditions. Metal manual arc welding (MMA) with the use of coated electrodes was used in the investigations. Tekken weldability tests were performed underwater at 0.5 m depth and in the air. Nondestructive tests, metallographic examinations of welds, ferrite content assessment in microstructure and hardness test were performed....
-
Electrochemical sensor for measurement of volatile organic compounds employing square wave perturbation voltage
PublicationThe paper presents the results of investigation on a prototype sensor for measurement of benzaldehyde in air. Sensitivity and limit of quantification of the sensor were determined for different internal electrolyte using the square wave voltammetry (SWV) as a detection technique. The working and counter electrodes were made of platinum. Ionic liquids 1-hexyl, 3-methylimidazolium chloride,1-hexyl, 3-methylimidazolium bis (trifluoromethanesulfonyl)...
-
Pathological brain network activity: memory impairment in epilepsy
PublicationOur thinking, memory and cognition in general, relies upon precisely timed interactions among neurons forming brain networks that support cognitive processes. The surgical evaluation of drug-resistant epilepsy using intracranial electrodes provides a unique opportunity to record directly from human brain and to investigate the coordinated activity of cognitive networks. In this issue of Neurology®, Kleen and colleagues1 implicate...
-
Model of noise sources in supercapacitors
PublicationThe paper presents detailed model of noise sources in supercapacitors. Noise phenomena observed in supercapacitors may be used as a diagnostic tool for assessment of supercapacitor quality or degradation mechanisms (e.g. corrosion of the electrodes or cloggin g up the pores) during ageing. Therefore, it is important to consider where noise is generated. The equivalent circuit of noise sources existing...
-
The set of 22 sessions of 14-channel eeg signals recorded during watching pictures
Open Research DataThe data were collected in order to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals collected from 10 persons within 22 sessions, during which 45 different random photos taken from the ImageNet...
-
Neural oscillations induced by IAPS pictures (session 10)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 1)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 9)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 5)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 2)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 11)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 3)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 6)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 4)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 8)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 7)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 14)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 13)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 16)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 19)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 17)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 22)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 15)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 21)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 20)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 12)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 18)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Hydrogenation process ofTiO2/BiVO4/PEDOT:PSS observed by XPS method
Open Research DataTitania nanotubes synthesis was based on a two-stage anodization process at water/ethylene glycol (5%/95%) electrolyte containing 0.27 M NH4F and 1 M H3PO4 described previously. Anodization process was performed in two-electrode cell compartment using platinum mesh as a cathode. The distance between electrodes was about 2 cm. The anodization voltage...
-
Neural oscillations induced by IAPS pictures (session 24)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 23)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 25)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Neural oscillations induced by IAPS pictures (session 26)
Open Research DataThe data were collected to perform research on the possibility of controlling the content displayed on the monitor screen using human emotional states extracted from EEG signals. The dataset contains recordings of 14-channel EEG signals gathered from seven persons aged 23 - 35 within 26 sessions, during which 45 different random photos, taken from the...
-
Non-enzymatic flexible glucose sensing platform based on nanostructured TiO2–Au composite
PublicationAll over the world the number of people suffering from diabetes and related complications is drastically growing. Therefore, the need for accurate, reliable and stable sensor for monitoring of glucose in human body fluids is becoming highly desirable. In this work we show that material composed of gold layers deposited onto TiO2 nanotubes (NTs) formed onto the flexible Ti foil exhibits great response toward glucose oxidation and...
-
Temperature distribution of supercapacitors prepared by various technologies
PublicationSupercapacitors, also known by different names such as electrostatic double-layer capacitors (EDLCs) or ultra-capacitors, are electrical storage devices still in development. These devices require fast and reliable methods of assessing their state-of-health. Thermographic imaging is a method which can be applied with this aim due to its popularity, and the high negative impact of overheating on a supercapacitor’s parameters. Moreover,...
-
Study of the formation of calcareous deposits on cathodically protected steel in Baltic sea water
PublicationPurpose – The purpose of this paper is to investigate whether the sedimentation of calcareous deposits occurs on cathodically protected steel in Baltic sea water. Design/methodology/approach – Steel electrodes were cathodically polarized in natural Baltic sea water at potential þ0.150 V vs Zn electrode in potentiostatic mode. During exposure chronoamperometric measurements were carried out. After the exposure, the electrode’s surface...
-
Chemical-Assisted Mechanical Lapping of Thin Boron-Doped Diamond Films: A Fast Route Toward High Electrochemical Performance for Sensing Devices
PublicationThere is an urgent need for an effective and economically viable increase in electrochemical performance of boron-doped diamond (BDD) electrodes that are used in sensing and electrocatalytic applications. Specifically, one must take into consideration the electrode heterogeneity due to nonhomogenous boron-dopant distribution and the removal of sp2 carbon impurities saturating the electrode, without interference in material integrity....
-
9 - Solid oxide fuel and electrolysis cells
PublicationIn this chapter, the fundamental reactions, the geometrical designs, the material requirements, and the status of SOFCs and SOECs are presented. In the following seven chapters, the most important components of an SOC are described and the chapter ends with a summary and outlook. The described components are: (i) oxygen-ion conductors (electrolyte), (ii) anode materials for SOFCs (cathode in SOEC mode), (iii) cathode materials...
-
Functionalized azobenzocrown ethers as sensor materials—The synthesis and ion binding properties
PublicationNew 13- and 16-membered azobenzocrown ethers with aromatic amino, amide, ether–ester or ether–amide residue in para position to an azo moiety were obtained. Acid–base properties and ion binding ability of the colored compounds were studied by spectroscopic methods: UV–vis, fluorimetry and 1H NMR spectroscopy. Selected azobenzocrowns were tested as ionophores in ion-selective membrane electrodes (ISEs) – classic and miniature all...
-
Zastosowanie techniki ściegu odpuszczającego do spawania mokrego
PublicationW artykule przedstawiono zastosowanie techniki ściegu odpuszczającego do poprawy właściwości złączy ze stali konstrukcyjnych wykonywanych w warunkach mokrego spawania pod wodą. Scharakteryzowano spawanie mokre elektrodami otulonymi zmiany struktury i właściwości złączy spawanych przez nakładanie ściegów odpuszczających. Przedstawiono metodykę oraz wyniki badań metalograficznych i twardości próbek ze stali konstrukcyjnej o podwyższonej...
-
Badania spawalności stali S460N w środowisku wodnym z wykorzystaniem próby Tekken
PublicationSpawanie w środowisku wodnym niesie ze sobą wiele problemów, wśród których najważniejszym jest skłonność stali do powstawania pęknięć zimnych. O ile w przypadku spawania na powietrzu istnieje wiele metod zapobiegania tym pęknięciom, o tyle pod wodą zastosowanie tych metod jest ograniczone. Z tego powodu konieczne jest określenie skłonności danego materiału do pękania zimnego. W pracy oceniono spawalność drobnoziarnistej...
-
Weldability of S500MC Steel in Underwater Conditions
PublicationWet welding with the use of covered electrodes is one of the methods of underwater welding. This method is the oldest, the most economic and the most versatile. The main difficulties during underwater wet welding are: high cooling rates of the joint, the presence of hydrogen in the arc area and formation of hard martensitic structure in the weld. These phenomena are often accompanied by porosity of welds and large number of spatters,...
-
Characterization of various drinking waters by new potentiometric taste sensor with lipid, lipid-like polymer membranes
PublicationA new sensing system comprising five all-solid-state electrodes with lipid, lipid like-polymer membranes was applied for rapid qualitative and quantitative analysis of various drinking waters. The results elaborated by chemometric methods revealed sensitivity to CO2 content in drinking water, suggesting that this sensing system could be used as a taste sensor. The ability of taste sensor to perform quantitative analysis of minerals...
-
Polypyrrole based gas sensor for ammonia detection
PublicationThe nature of polypyrrole response to toxic gases does not allow using the sensor in a conventional way. The main aim of this study is to acquire the information about the concentration using different approaches: a linear approximation, a non-linear approximation and a tangent method. In this paper a two-steps procedure for sensor response measurements has been utilized. Polypyrrole films were electrochemically synthesized on...
-
COLD CRACKING OF S460N STEEL WELDED IN WATER ENVIRONMENT
PublicationThis paper shows results of weldability testing of fine-grained high -strength low- alloy S460N steel welded in water environment by covered electrodes. The tests were carried out by using the CTS test specimens with fillet welds. Four specimens were welded under water and one specimen in air. Welded joints were subjected to non-destructive visual and penetration tests. The accepted joints were then subjected to macroscopic and...
-
Microbial fuel cell applications for removal of petroleum hydrocarbon pollutants: A review
PublicationBioelectrochemical systems (BESs) are considered as the potential approaches to remediate the environments contaminated by hydrocarbons. This review addresses the application of BESs particularly microbial fuel cells (MFCs) in degradation of petroleum hydrocarbons, including BTEXs, from soil, water, wastewater and sediments. Details on reactor design and critical issues are discussed. Aspects on electrodes, redox mediators and...
-
Determination of time delay between ventricles contraction using impedance measurements
PublicationThe paper presents a novel approach to assessment of ventricular dyssynchrony basing on multichannel electrical impedance measurements. Using a proper placement of electrodes, the sensitivity approach allows estimating time difference between chambers contraction from over determined nonlinear system of equations. The theoretical considerations which include Finite Element Method simulations were verified using measurements on...